URO X EV LIGHTING FIXTURES Aydınlatma Armatürleri ... · Tehlikeli Sahalar, Bölge: 1/2 (Gazlar)...

3
TURKEY/Kocaeli 30 Conduit Mounted 60° Borulama 60° EV.BA EV series / serisi UYGULAMA EV.BA serisi akkor ya da kompakt floresan ampullü (tasarruflu) aydınlatma armatürleri Grup II tehlikeli açık ya da kapalı alanlarda kullanılmaktadır. APPLICATION EV.BA series incandescent or compact fluorescent lighting fixtures are used in Group II hazardous areas at indoor or outdoor services. LIGHTING FIXTURES Aydınlatma Armatürleri INSTALLATION / KULLANIM Hazardous Areas, Zone: 1/2 (Gases) - 21/22 (Dusts) Tehlikeli Sahalar, Bölge: 1/2 (Gazlar) - 21/22 (Toz) CLASSIFICATION/ SINIFLANDIRMA Group II - Category 2G/2D Grup II - Kategori 2G/2D EV Series Lightıng Fixtures ATEX 94/9/EC II 2 G Ex d IIB Gb II 2 D Ex t IIIC IP 67 Db Execution/Sertifika Kodu Zone 1/2 - Zone 21/22 Installation/Kullanım Sahası IP 67 Protection Degree/Koruma Sınıfı MP 11 ATEX 0077.X Certificate Ref./Sertifika No EN 60079-0:2012; EN 60079-1:2007; EN 60079-31:2009 Rules of compl./ Uyum Kuralları

Transcript of URO X EV LIGHTING FIXTURES Aydınlatma Armatürleri ... · Tehlikeli Sahalar, Bölge: 1/2 (Gazlar)...

Page 1: URO X EV LIGHTING FIXTURES Aydınlatma Armatürleri ... · Tehlikeli Sahalar, Bölge: 1/2 (Gazlar) - 21/22 (Toz) CLASSIFICATION/ SINIFLANDIRMA Group II - Category 2G/2D Grup II -

TURKEY/Kocaeli30

Conduit Mounted 60°

Borulama 60°

EV.BA

εε URO Exproof EquipmentX

Bireks

εUROεX

EVseries /ser is i

UYGULAMA

EV.BA serisi akkor ya da kompakt floresan ampullü

(tasarruflu) aydınlatma armatürleri Grup II tehlikeli

açık ya da kapalı alanlarda kullanılmaktadır.

APPLICATION

EV.BA series incandescent or compact fluorescent

lighting fixtures are used in Group II hazardous

areas at indoor or outdoor services.

LIGHTING FIXTURESAydınlatma Armatürleri

INSTALLATION / KULLANIM Hazardous Areas, Zone: 1/2 (Gases) - 21/22 (Dusts)Tehlikeli Sahalar, Bölge: 1/2 (Gazlar) - 21/22 (Toz)

CLASSIFICATION/ SINIFLANDIRMAGroup II - Category 2G/2DGrup II - Kategori 2G/2D

EV Series Lightıng Fixtures

ATEX 94/9/EC

II 2 G Ex d IIB Gb

II 2 D Ex t IIIC IP 67 DbExecution/Sertifika Kodu

Zone 1/2 - Zone 21/22Installation/Kullanım Sahası

IP 67Protection Degree/Koruma Sınıfı

MP 11 ATEX 0077.XCertificate Ref./Sertifika No

EN 60079-0:2012; EN 60079-1:2007; EN 60079-31:2009Rules of compl./ Uyum Kuralları

Page 2: URO X EV LIGHTING FIXTURES Aydınlatma Armatürleri ... · Tehlikeli Sahalar, Bölge: 1/2 (Gazlar) - 21/22 (Toz) CLASSIFICATION/ SINIFLANDIRMA Group II - Category 2G/2D Grup II -

Bireks Electric Co. 31

Figure 1

Assembly

εε URO Exproof EquipmentX

Bireks

εUROεX

INSTALLATION / KULLANIM Hazardous Areas, Zone: 1/2 (Gases) - 21/22 (Dusts)Tehlikeli Sahalar, Bölge: 1/2 (Gazlar) - 21/22 (Toz)

Electrical CharasteristicsMechanical Charasteristics

High Temperature Resistant Slicon Cableİnternal Wiring/KablolarNbr RubberGaskets/Kafes

Enternal Stainless SteelScrews/Civata4x1/2” - 4x3/4” ThreadedCable Entry/Kablo Girişi

EV.X.100

Photometric diagrams

EV.X.300

EV.X.200

Page 3: URO X EV LIGHTING FIXTURES Aydınlatma Armatürleri ... · Tehlikeli Sahalar, Bölge: 1/2 (Gazlar) - 21/22 (Toz) CLASSIFICATION/ SINIFLANDIRMA Group II - Category 2G/2D Grup II -

TURKEY/Kocaeli32

T E C H N I C A L DATA

CABLE ENTRY SIZE LAMPPHOLDER

SIZE

TEMP. CLASS

)DUST(

TEMP. CLASS

)GAS(LAMPCODE

EV SERIES LIGHTING FIXTURES TECHNICAL DATA

3/4”E 27T 80 °CT660W, 80W, 100WEV.BA.100

3/4”E 27T 80 °C T6160W, 200W, EV.BA.200

3/4”E 40T 80 °CT6250WEV.BA.250

3/4”E 40T 80 °CT6 300WEV.BA.300

DETAIL/DetayWEIGHT/Ağırlık)K.G(BACODE/Kodu

Figure 32.36 KG130 mm230 mmEV.BA.100

Figure 33.82 KG180 mm310 mmEV.BA.200

Figure 34.24 KG230 mm440 mmEV.BA.250

Figure 38.82 KG250 mm650 mmEV.BA.300

Figure 3

Assembly