4
RPEK1-03 Size 03 Q max 20 l/min (5 GPM) p max 250 bar (3600 PSI) (1450) (2180) (725) (2900) (3630) 0 10 15 100 150 50 200 250 20 1 (.) 53 ( .3) 1 (.) 40 ( .6) 2 5 2 3 4 5 6 7 (145) (218) (7 ) 3 0 10 15 5 10 15 20 (.) 53 ( .3) 1 (.) 40 ( .6) 2 5 3 2 1 P T (B) (A) T 24(0.95) (15) ((0.59)) ((0.59)) 2x 8 (0.315) (15) 24(0.95) 30,5(1.20) 61(2.40) ((0.52)) 3x 6,4(0.25) 56(2.205) 41,2(1.62) 44,4(1.75) 5,8 (0.23) (13,2) (0.48) 12,2 Subject to change · RPEK1-03_4027_1en_02/2016 Page 1 www.argo-hytos.com 4/2 and 4/3 Directional Control Valve, Solenoid Operated, Bankable Technical Features Characteristics measured at ν = 32 mm 2 /s (156 SUS) Pressure drop related to flow rate Technical Data Operating pressure p [bar (PSI)] Flow Q [l/min (GPM)] Pressure drop Δp [bar (PSI)] Operating limits Valve size 03 Max. flow l/min (GPM) 20 (5.3) Max. operating pressure at port P, A, B bar (PSI) 250 (3630) Max. operating pressure at port T bar (PSI) 210 (3050) Fluid temperature range (NBR) °C (°F) -30 ... +80 (-22 ... +176) Fluid temperature range (FPM) °C (°F) -20 ... +80 (-4 ... +176) Ambient temperature range °C (°F) -30 ... +50 (-22 ... +122) Supply voltage tolerance % DC: ±10 Max. switching frequency 1/h 15 000 Enclosure type acc.to EN 60529 IP65 Switching time at ν=32 mm 2 /s (156 SUS) ON ms 30 ... 50 OFF ms 30 ... 50 Mass - valve with 1 solenoid - valve with 2 solenoids kg (lbs) 0.90 (1.98) 1.05 (2.32) Data Sheet Type General information GI_0060 Products and operating conditions Coil types / connectors C_8007 / K_8008 C14B*/ K* Mounting interface / tolerances SMT_0019 Size 03 Spare parts SP_8010 Direct acting, directional control valve with bankable mounting interface Designed to be assembled in series or parallel, mounting up to 8 body modules High transmitted hydraulic power up to 250 bar, optimized design to minimize the pressure drop Housing with three chambers for production cost savings The valve is available with interchangeable DC solenoids Wide range of solenoid electrical terminal versions available Wide range of interchangeable spools and manual overrides available Suitable for compact applications in the mobile and mini-power pack industries Space and cost saving! With optional end valves No need for bar manifold to construct complex circuit assemblies from stock In the standard version, the valve housing is phosphated and steel parts are zinc-coated for 240 h protection acc. to ISO 9227 Enhanced surface protection for mobile sector up to 520h salt spray acc to ISO 9227 available Operating limits for maximum hydraulic power at rated temperature and supplied with voltage equal to 90% of the nominal value Flow Q [l/min (GPM)] Spool symbol P-A P-B A-T B-T P-T Z11, Y11, P11 1 1 1 1 R11, R21, X11 2 2 2 2 Y51, Z51 1 1 C11 3 3 3 3 2 H11, H51 1 1 1 1 2 C51 3 3 2 A51 2 2 X11 2 2 2 2 Y82 2 2 1 3 Z81 1 2 Spool symbol Z11, Z51, R11, P11 1 C11, C51, X11 2 H11, Y11, H51 3 C11, Y11, Y51 4 R21 5 A51, Y82 6 Z81 7 For operating limits under conditions other than shown consult our technical department. Admissible operating limits may be considerably lower with only one direction of flow (A or B plugged or without flow).

Transcript of Technical Features - ARGO- · PDF fileTechnical Features Characteristics measured at ν = 32...

Page 1: Technical Features - ARGO- · PDF fileTechnical Features Characteristics measured at ν = 32 mm2/s (156 SUS) ... › High transmitted hydraulic power up to 250 bar, optimized design

RPEK1-03 Size 03 Qmax 20 l/min (5 GPM) pmax 250 bar (3600 PSI)

(1450)

(2180)

(725)

(2900)

(3630)

0 10 15

100

150

50

200

250

20

1

( . )5 3( .3)1 ( . )4 0( .6)2

5

2

3

45

6 7

(145)

(218)

(7 )3

0 10 15

5

10

15

20

( . )5 3( .3)1 ( . )4 0( .6)2

5

3

21

P

T

(B)(A)

T

24(0.95)

(15)((0.59)) ((0.59))

2x 8(0.315)

(15)

24(0.95)30,5(1.20)

61(2.40)

((0.5

2))

3x 6,4(0.25)

56(2

.205

)

41,2

(1.6

2)

44,4

(1.7

5)5,

8 (0

.23)

(13,

2)

(0.4

8)12

,2

Subject to change · RPEK1-03_4027_1en_02/2016

Page 1 www.argo-hytos.com

4/2 and 4/3 Directional Control Valve, Solenoid Operated, Bankable

Technical Features

Characteristics measured at ν = 32 mm2/s (156 SUS)

Pressure drop related to flow rate

Technical Data

Ope

ratin

g pr

essu

re p

[bar

(PSI

)]

Flow Q [l/min (GPM)]

Pres

sure

dro

p Δ

p [b

ar (P

SI)]

Operating limits

Valve size 03Max. flow l/min (GPM) 20 (5.3)Max. operating pressure at port P, A, B bar (PSI) 250 (3630)Max. operating pressure at port T bar (PSI) 210 (3050)Fluid temperature range (NBR) °C (°F) -30 ... +80 (-22 ... +176)Fluid temperature range (FPM) °C (°F) -20 ... +80 (-4 ... +176)Ambient temperature range °C (°F) -30 ... +50 (-22 ... +122)Supply voltage tolerance % DC: ±10Max. switching frequency 1/h 15 000Enclosure type acc.to EN 60529 IP65

Switching time at ν=32 mm2/s (156 SUS) ON ms 30 ... 50OFF ms 30 ... 50

Mass - valve with 1 solenoid - valve with 2 solenoids kg (lbs) 0.90 (1.98)

1.05 (2.32)Data Sheet Type

General information GI_0060 Products and operating conditionsCoil types / connectors C_8007 / K_8008 C14B*/ K*Mounting interface / tolerances SMT_0019 Size 03Spare parts SP_8010

› Direct acting, directional control valve with bankable mounting interface › Designed to be assembled in series or parallel, mounting up to 8 body modules › High transmitted hydraulic power up to 250 bar, optimized design to minimize

the pressure drop › Housing with three chambers for production cost savings › The valve is available with interchangeable DC solenoids › Wide range of solenoid electrical terminal versions available › Wide range of interchangeable spools and manual overrides available › Suitable for compact applications in the mobile and mini-power pack industries › Space and cost saving! With optional end valves › No need for bar manifold to construct complex circuit assemblies from stock › In the standard version, the valve housing is phosphated and steel parts are zinc-coated for

240 h protection acc. to ISO 9227 › Enhanced surface protection for mobile sector up to 520h salt spray acc to ISO 9227 available

Operating limits for maximum hydraulic power at rated temperature and supplied with voltage equal to 90% of the nominal value

Flow Q [l/min (GPM)]

Spool symbol P-A P-B A-T B-T P-TZ11, Y11, P11 1 1 1 1R11, R21, X11 2 2 2 2Y51, Z51 1 1C11 3 3 3 3 2H11, H51 1 1 1 1 2C51 3 3 2A51 2 2X11 2 2 2 2Y82 2 2 1 3Z81 1 2

Spool symbolZ11, Z51, R11, P11 1C11, C51, X11 2H11, Y11, H51 3C11, Y11, Y51 4R21 5A51, Y82 6Z81 7

For operating limits under conditions other than shown consult our technical department. Admissible operating limits may be considerably lower with only one direction of flow (A or B plugged or without flow).

Page 2: Technical Features - ARGO- · PDF fileTechnical Features Characteristics measured at ν = 32 mm2/s (156 SUS) ... › High transmitted hydraulic power up to 250 bar, optimized design

41,3 (1.63)

20 (0

.79)

�13

,4 (0

.53)

�30

(1.1

8)

13,4

(0.5

3)

41,3(1.63)

30 (1

.18)

39,3

(1.5

5)

34,1

(1.3

54)

41,3 (1.63)

�13

,4 (0

.53)

�30

(1.1

8)

59(2.32) 71(2.80) 66 (2.60)

RPEK1-03 / -

23

0120002400

GSO

E1E2

E3AE4A

E12AE13A

Y82

Y11

P11

H11

C11

Z11 R11

R21

A51

Y51

C51

Z81

Z51

Z11

X11

C11

Y11

H51

Subject to change · RPEK1-03_4027_1en_02/2016

Page 2www.argo-hytos.com

Ordering Code

Spool Symbols

Type Symbol Interposition Type Symbol Interposition Type Symbol Interposition

Solenoid Coil in millimeters (inches)

The indicated IP protection level is only reached with a properly mounted connector.

E1, E2 - Protection degree IP65 E3A, E4A - Protection degree IP67 E12A, E13A - Protection degree IP67

Manual Override in millimeters (inches)

In case of solenoid malfunction or power failure, the spool of the valve can be shifted by manual override as long as the pressure in port T does not exceed 25 bar (363 PSI). For alternative manual overrides contact our technical support.

No designation - standard N2- protected with rubber boot N5 - socket head screw 3

Number of valve positions two positionsthree positions

Rated supply voltage of solenoids(at the coil terminal)12 V DC / 1.83 A24 V DC / 0.92 A

4/2 and 4/3 directional controlvalve, solenoid operated,bankable

Valve size

Type of connectionthread A, B - G1/4thread A, B SAE6 - 9/16-18UNFstackable

Spool symbolssee the table of “Spool Symbols“

ConnectorEN 175301-803-AE1 with quenching diodeAMP Junior Timer - axial direction (2 pins; male)E3A with quenchind diodeDeutsch DT04-2P - axial direction (2 pins; male)E12A with quenching diode

No designationV

No designationAB

No designationN2N5

SealsNBR

FPM (Viton)

Surface treatmentstandard

zinc-coated (ZnCr-3), ISO 9227 (240 h)zinc-coated (ZnNi), ISO 9227 (520 h)

Manual overridestandard

protected with rubber bootsocket head screw

Modelstandard, P, T through ports, without ports A1,B1

P, T through ports, A1, B1 side ports, all ports sealedP, T through ports, A1, B1 side ports inverted (not sealed)

end valve, one side P, T sealed portsend valve, one side P, T ports inverted (not sealed)

end valve, one side P, T ports, A1, B1 side ports, all ports not sealed end valve, one side P, T, A1, B1 side ports inverted, all ports not sealed

No designationP1P2Z1Z2Z3Z4

- For directional valves with two solenoids, one solenoid must be de-energized before the other solenoid can be energized.

- For other solenoid voltages see data sheet C_8007.- The solenoid operated valves are delivered without connectors. For connectors

version see data sheet K_8008.- The orifice to the P port can be ordered separately, see data sheet SP_8010.- Besides the shown, commonly used valve versions other special models are available.

Contact our technical support for their identification, feasibility and operating limits.

Page 3: Technical Features - ARGO- · PDF fileTechnical Features Characteristics measured at ν = 32 mm2/s (156 SUS) ... › High transmitted hydraulic power up to 250 bar, optimized design

13(0

.51)

10(0

.39)

33(1

.30)

A

26(0

.47)

12(0

.47)

12,2

THREAD

D

59(2.32)179(7.05)

(0.4

8)

30(1.18) 15,5(0.61)

15,5

(0.6

1)31

(1.2

2)

�12,4(0.49)

1,4(

0.06

)

( 5,3(0.21)�

( 10,8(0.43)�

�8(0.32)

30(1

.18)

�8,5 (0.3 )4

1x45

15(0

.59)

12(0

.47)

4xM5

15

1,4

(0.0

)6

30 (1.18)56,9 (2.24)

(0.3 )2(0.2 )1

15,5 (0.61)

10,8 (0.4 )912,4(0.4 )3

4,1 (1.16)

ba

5,3 8

B

P

(A)

T

B

P

(B)(A)(B)(B)

T TT

13(0

.51)

10(0

.39)

33(1

.30)

A

26(0

.47)

12(0

.47)

12,2

THREAD

D

59(2.32)179(7.05)

(0.4

8)

30(1.18) 15,5(0.61)

15,5

(0.6

1)31

(1.2

2)

�12,4(0.49)

1,4(

0.06

)

( 5,3(0.21)�

( 10,8(0.43)�

�8(0.32)

30(1

.18)

�8,5 (0.3 )4

1x45

15(0

.59)

12(0

.47)

4xM5

15

1,4

(0.0

)6

30 (1.18)56,9 (2.24)

(0.3 )2(0.2 )1

15,5 (0.61)

10,8 (0.4 )912,4(0.4 )3

4,1 (1.16)

ba

5,3 8

B

P

(A)

T

B

P

(B)(A)(B)(B)

T TT

G S

THREAD G1/4 SAE6-9/16-18UNF

∅ D [mm] 20,9H13 25+0.5

∅ D [in] 0.823 0.984+0.02

A [mm (in)] 1 (0.039) 0.5 (0.020)

P

T

7(0.28)123,5(4.86)

a

P

Tb

P, T

thr

ough

por

ts,

with

out

port

s A

1,B1

Standard body version

P, T

thr

ough

por

ts, A

1,B1

si

de p

orts

, all

port

s se

aled

P, T

thr

ough

por

ts, A

1, B

1 si

de p

orts

, A1,

B1

inve

rted

(n

ot s

eale

d)

End

valv

e, o

ne s

ide

P, T

se

aled

por

ts

End

valv

e, o

ne s

ide

P, T

po

rts

inve

rted

(not

se

aled

)

End

valv

e, o

ne s

ide

P, T

po

rts,

A1,

B1

side

por

ts,

all p

orts

sea

led

End

valv

e, o

ne s

ide

P, T

, A

1, B

1 si

de p

orts

in

vert

ed,

all p

orts

not

sea

led

A B

T

P

BA

TP

B1A1 TP

TP,

TP, B1A1

BA

TP

B1A1 TP

BA

TP,

TP, B1A1

BA

TP,

BA

BA

TP,

TP TP

BA

TP, B1A1

TP B1A1

BA

BA

TP, B1A1

TPA1 B1

P1 -

O

P2 -

O

BA

TP

TP,

BA

TP

BA

TP,

BA

TP B1A1

TP, B1A1

BA

TP B1A1

BA

TP, B1A1

BA

TP B1A1

TP

TP, B1

TP,

BA

TP B1A1

TP

BA

TP, B1

TP,

A1A1for vertical assembly 4xM5

BA

TP

TP

TP,

TP,

BA

TP

TP

BA

TP,

TP,

for vertical assembly 4xM5

Z1 -

O

Z2 -

O

Stan

dar

dP1

- G

(S)

Z1 -

G (

S)Z3

- G

(S)

Z3 -

O

P2 -

G (

S)Z2

- G

(S)

Z4 -

G (

S)

Z4 -

O

Subject to change · RPEK1-03_4027_1en_02/2016

Page 3www.argo-hytos.com

Design Forms G (S), O in millimeters (inches)

Dimensions in millimeters (inches)

Body version P1 - G (S)Valve with two solenoids

Body version P1 - OStackable version

Valve with one solenoid „a“Spool symbols R11, R21, Y51, C51, Z51

Valve with one solenoid „b“Spool symbols H11

Page 4: Technical Features - ARGO- · PDF fileTechnical Features Characteristics measured at ν = 32 mm2/s (156 SUS) ... › High transmitted hydraulic power up to 250 bar, optimized design

24 (0

.94)

2(0.08

)

2(0.08

)

14.5(

)2(0

.57

7,25(

)2(0

.29

48(1.89)

61(2.40)

6,4(0.25)

6,5(0.24)

A14

()

2(0.55

24(2

(0.9

4)42

(1.6

5)

B

19 (0

.75)

b

23 (0

.91)56

(2.2

1)

68(2

.68)

61(2.40)

24 (0

.94)

2(0.08

)

77(3.03)

48(1.89)

31,5

(1.2

4)50(1

.97)

15(0

.59)

68(2

.68)

33(1

.30)

35(1

.38)

Subject to change · RPEK1-03_4027_1en_02/2016

Page 4www.argo-hytos.com

Dimensions in millimeters (inches)

Dimensions mm (inches)

Number of sections 1 2 3 4 5 6 7 8

Dimension A 87 (3.43) 118 (4.65) 149 (5.87) 180 (7.09) 211 (8.31) 242 (9.53) 273 (10.75) 304 (11.97)

Dimension B 114 (4.49) 145 (5.71) 176 (6.93) 207 (8.15) 238 (9.37) 269 (10.59) 300 (11.81) 331 (13.03)

Dimension L 60 (2.36) 100 (3.94) 133 (5.24) 163 (6.42) 194 (7.64) 224 (8.82) 256 (10.08) 287 (11.30)

Block Assembly in millimeters (inches)

VERSION - valve with inlet block and pressure relief valve see datasheet 4057 - RPEK1-03/B

connection P and T - G3/8

HB03-RPEK-MP1

mounting angle

connectionA and B - G1/4

HB03-RPEK-08

mounting bolts M6 x L (see table) 12 Nm (8.85 Ibf.ft)

screw M6 x 12 12 Nm (8.85 ft-Ibf)

Pressure relief valve