SDS U1200-08 VORTEX FLOWMETER - WordPress.com · Reynolds Number (Re) Calculation: ... Low pressure...

4
1 bar = 0.1 MPa Meter Body / Sensor Transmitter Terminals Pressure/Temperature Operating Range Temperature (°C) Pressure (barg) Display Transmitter Re=——— Reynolds Number (Re) Calculation: ν d = pipe diameter V = velocity ν= viscosity d x V 1) Subject to the limitations of fluid freezing point 2) For superheated steam, air and other gasses, an external pressure sensor and flow computer may be required if inlet pressure fluctuates 3) Do not use for toxic, flammable or otherwise hazardous fluids 4) + 0.3% for remote version 12 34 + - + - Esc E + - 48.25 kg/h 3702.6 t I Connection Size Connection Compatibilities Operating Pressure Range (barg) Temperature Range (°C) Applicable Fluid Accuracy Repeatability Vibration Resistance Volume Flow Mass Flow 0 – 49.6 (See the table to the right for details) -200 1) – +400 (See the table to the right for details) Steam 2) , Air 2) , Water and others 2) 3) Gas/Steam: ± 1% of reading (Re > 20 000), ± 1% of full scale (Re: 4 000 – 20 000) Liquid: ± 0.75% of reading (Re > 20 000) ± 0.75% of full scale (Re: 4 000 – 20 000) Saturated ± 2% of reading 4) (Re > 20 000) Steam: ± 2% of full scale 4) (Re: 4 000 – 20 000) Within 0.25% of reading At least 1G in all directions (10 – 500 Hz) Flangeless Flanged DN 15, 25, 40, 50, 80, 100, 150 DN 15, 25, 40, 50, 80, 100, 150, 200, 250, 300 See details in the Dimensions section Model EF73 Mounting Position No restriction with regards to meter accuracy Explosion Class Ambient Temperature Ingress Resistance Output Power Source Power Consumption Power Line Connection Field Wiring Load Line Resistance Non-explosion proof Compact Type: -40 – +70 °C Remote Type: -40 – +80 °C IP 67 (NEMA 4X) Frequency (pulse) output: Open collector pulse (passive) Analog output: 4 – 20 mA DC 12 – 36 V DC (24 V DC recommended) 1.2 W DC (including sensor) G(PF)a/B 2-wire System (2-conductor, shielded, at least 1.25 mm 2 ) Maximum 550at 24 V B A C To avoid abnormal operation, accidents or serious injury, DO NOT use this product outside of the specification range. Local regulations may restrict the use of this product to below the conditions quoted. CAUTION Sample display A: Power supply/ current output B: Optional frequency output C: Ground terminal (for remote version) Specifications -200 -100 0 5 10 15 20 16 25 30 0 100 200 300 400 35 40 45 50 49.6 55 DIN PN 10, JIS 10K JIS 20K ASME 150 DIN PN 16 DIN PN 25 DIN PN 40 ASME 300 Maximum Operating Pressure High-performance vortex flowmeter with robust sensor for highly accurate volume or mass flow measurements of gasses, liquids, saturated and superheated steam. 1. DSC (Differential Switched Capacitance) sensor offers a wide measuring range, with a high resistance to thermal shock, vibration and water hammer. 2. Integrated flow computer calculates mass flow from measured volume flow and temperature variables. 3. Capable of simultaneous pulse (interval) and analog (instantaneous) output. 4. Requires no maintenance, has no moving parts, and experiences no zero point drift. 5. Low pressure drop through body. Features SDS U1200-08 VORTEX FLOWMETER MODEL EF73 STAINLESS STEEL RELIABLE FLOW MEASURING SYSTEM FOR GAS, STEAM AND LIQUIDS

Transcript of SDS U1200-08 VORTEX FLOWMETER - WordPress.com · Reynolds Number (Re) Calculation: ... Low pressure...

Page 1: SDS U1200-08 VORTEX FLOWMETER - WordPress.com · Reynolds Number (Re) Calculation: ... Low pressure drop through body. Features SDS U1200-08 ... concentric reducer upstream of meter

1 bar = 0.1 MPa

Meter Body / Sensor

Transmitter Terminals

Pressure/Temperature Operating Range

Temperature (°C)

Pre

ssu

re (b

arg)

Display

Transmitter

Re=———

Reynolds Number (Re) Calculation:

νd = pipe diameter V = velocity ν = viscosity

d x V1) Subject to the limitations of fluid freezing point 2) For superheated steam, air and other gasses, an

external pressure sensor and flow computer may be required if inlet pressure fluctuates3) Do not use for toxic, flammable or otherwise hazardous fluids 4) + 0.3% for remote version

1 2 3 4+ - + -

Esc

E+-

48.25 kg/h3702.6 tI

Connection

Size

Connection Compatibilities

Operating Pressure Range (barg)

Temperature Range (°C)

Applicable Fluid

Accuracy

Repeatability

Vibration Resistance

Volume Flow

Mass Flow

0 – 49.6 (See the table to the right for details)

-2001) – +400 (See the table to the right for details)

Steam2), Air2), Water and others2) 3)

Gas/Steam:± 1% of reading (Re > 20 000),± 1% of full scale (Re: 4 000 – 20 000)

Liquid: ± 0.75% of reading (Re > 20 000)± 0.75% of full scale (Re: 4 000 – 20 000)

Saturated ± 2% of reading4) (Re > 20 000)Steam: ± 2% of full scale4) (Re: 4 000 – 20 000)

Within 0.25% of reading

At least 1G in all directions (10 – 500 Hz)

Flangeless Flanged

DN 15, 25, 40, 50, 80, 100, 150

DN 15, 25, 40, 50, 80, 100, 150, 200, 250, 300

See details in the Dimensions section

Model EF73

Mounting Position No restriction with regards to meter accuracy

Explosion Class

Ambient Temperature

Ingress Resistance

Output

Power Source

Power Consumption

Power Line Connection

Field Wiring

Load Line Resistance

Non-explosion proof

Compact Type: -40 – +70 °CRemote Type: -40 – +80 °C

IP 67 (NEMA 4X)

Frequency (pulse) output: Open collector pulse (passive)Analog output: 4 – 20 mA DC

12 – 36 V DC (24 V DC recommended)

1.2 W DC (including sensor)

G(PF)a/B

2-wire System (2-conductor, shielded, at least 1.25 mm2)

Maximum 550Ω at 24 V

BA

C

To avoid abnormal operation, accidents or serious injury, DO NOT use this product outside of the specification range. Local regulations may restrict the use of this product to below the conditions quoted.

CAUTION

Sample display

A: Power supply/current output

B: Optional frequency output

C: Ground terminal (for remote version)

Specifications

-200 -1000

5

10

15

2016

25

30

0 100 200 300 400

35

40

45

5049.6

55

DIN PN 10, JIS 10K

JIS 20K

ASME 150

DIN PN 16

DIN PN 25

DIN PN 40

ASME 300

Maximum Operating Pressure

High-performance vortex flowmeter with robustsensor for highly accurate volume or mass flowmeasurements of gasses, liquids, saturated andsuperheated steam.

1. DSC (Differential Switched Capacitance) sensoroffers a wide measuring range, with a highresistance to thermal shock, vibration and waterhammer.

2. Integrated flow computer calculates mass flow frommeasured volume flow and temperature variables.

3. Capable of simultaneous pulse (interval) andanalog (instantaneous) output.

4. Requires no maintenance, has no moving parts,and experiences no zero point drift.

5. Low pressure drop through body.

Features

SDS U1200-08

VORTEXFLOWMETERMODEL EF73 STAINLESS STEEL

RELIABLE FLOW MEASURING SYSTEM FOR GAS, STEAM AND LIQUIDS

Page 2: SDS U1200-08 VORTEX FLOWMETER - WordPress.com · Reynolds Number (Re) Calculation: ... Low pressure drop through body. Features SDS U1200-08 ... concentric reducer upstream of meter

Esc

E- +

Reducer

ExpansionPipe

D = Nominal diameter of piping

Required Straight PipingPiping

ElementPiping Example and Required

Length of Straight Piping Remarks

Elbow

Control Valve,Globe Valve,

etc.

FlowConditioner(Rectifier)

PressureMeasurement

Points

Mounting Position

Pipeline Insulation

C

D

A

B

Ensuring Steam Quality

* Equivalent materials ** Flangeless model only, to ensure concentric installation; includes centering rings, threaded bolts, nuts,

washers and flange gaskets*** Remote version only, see next page

When there is a concentric reducer upstream of meter

When there is a concentric expansion pipe upstream of meter

When there is an elbow upstream of meter

When there are two elbows horizontally upstream of meter

When there are two elbows vertically (3-dimensional) upstream of meter

When there is a factor that suddenly disturbs flow upstream of meter

When a flow conditioner is installed upstream of meter

If used, a pressure measurement point is to be mounted downstream of the meter as shown

③②

EscEsc

E- +

EscEsc

E- +

EscEsc

E- +

There is no restriction for mounting position (A – D) in regards to meter accuracy. However, special care is recommended for the following flow mediums:

1. High-temperature FluidsFor high-temperature fluids (steam, condensate), positions A, B or C should be selected to protect the transmitter form heat.

2. LiquidsTo make sure the pipes are completely flooded with liquid, position C is recommended.

The pipe stand serves as a radiator and protects the electronics from overheating. Therefore, ensure that sufficient surface area remains exposed.Be sure not to insulate past the level marked “max.” on the pipe stand.

Wet steam has a higher density than saturated steam.Since the flowmeter mass flow calculations are based on saturated steam density, the actual mass flow of wet steam will be higher than shown by the flowmeter. The upstream installation of a separator (DC3S) is suggested to ensure steam quality and flowmeter accuracy.The proper separation and drainage of condensate is a recommended practice for all steam applications.

50D

SaturatedSteam

WetSteam

DC3S separator withbuilt-in steam trap

EscEsc

E- +

Specifications

Piping Installation

EscEsc

E- +15D 5DA B

EscEsc

E- +18D 5DA B

EscEsc

E- +20D 5DA B

EscEsc

E- +25D 5DA B

EscEsc

E- +40D 5DA B

EscEsc

E-- ++50D 5DA B

5D8DBA

2D EscEsc

E- +

PT

3 – 5DEsc

E- +

No.

Description

Meter Body

Bluff Body

DSC Sensor (wetted parts)

DSC Sensor (non-wetted parts)

Pipe Stand

Transmitter Housing

Gasket

Nameplate

Mounting Kit**

Remote Transmitter Mount***

Connecting Cable (30 m)***

Material*

Cast Stainless Steel SCS16A

Cast Stainless Steel SCS16A

Stainless Steel SUS316

Stainless Steel SUS304

Cast Stainless Steel SCS13A

Die-cast Aluminum

Graphite

Die-cast Aluminum

DIN*

1.4435

1.4435

1.4435

1.4301

1.4308

ASTM/AISI

A351 Gr. CF3M

A351 Gr. CF3M

AISI316*

AISI304*

A351 Gr. CF8

SDS U1200-08

Page 3: SDS U1200-08 VORTEX FLOWMETER - WordPress.com · Reynolds Number (Re) Calculation: ... Low pressure drop through body. Features SDS U1200-08 ... concentric reducer upstream of meter

寸法

DN L φDH1

φdWeight**

(kg)

* Compatible with DIN 2501 PN10/16, 25/40, ASME class 150, 300, and JIS 10K/20K flange standards

** Weight is for compact version

① Pipe Mounting Kit

Suitable for DN 20 – 80 pipe.

(Includes bracket, threaded bolts and nuts.)

② Sunshade for Transmitter

③ Flow Conditioner

Compact Version

Compact Version¡EF73 Flanged

149

149

DL

L

154141

154141

H1

d

H1

¡EF73 Remote Transmitter

Remote Version

Remote Version

* Requires optional parts

Piping Installation

¡EF73 Flangeless EF73 Flangeless* (mm)

Dimensions

Remote Transmitter to Sensor Wiring

Piping InstallationOptions

Compact Remote

Other standards available, but weight may vary* Weight is for compact version, PN 40( ) Remote version

DN

L

H1Weight*

(kg)

EF73 Flanged (mm)

DIN 2501 ASME Class

PN10 PN16 PN25 PN40 150RF 300RF

115

115

154

141

φ85

φ85

65

L

221

H1

100

133

348

100123

H1

Wall Mounted

Remote transmitter weight: 3.5 kg

211

Pipe Mounted*

DN

20

– 80

pip

e

15

25

40

50

80

100

150

65

45

64

82

92

127

157

216

17

28

42

54

80

105

157

276

286

294

301

315

328

354

3.0

3.2

3.8

4.1

5.5

6.5

9.0

246

256

264

271

285

298

324

3

GN

GN

3

1

WT

WT

1

4

YL

YL

4

2

BN

BN

2

5

GY

GY

5

6

PK

PK

6

7

BU

BU

7

8

RD

RD

8

DIF

F +

DIF

F +

DIF

F –

DIF

F –

GR

OU

ND

GR

OU

ND

+ 5

VA

+ 5

VA

– 5

VA

– 5

VA

TE

MP

1T

EM

P 1

TE

MP

2T

EM

P 2

TE

MP

3T

EM

P 3

15

25

40

50

80

100

150

200

250

300

200

250

300

380

450

200

250

300

380

450

200

250

300

380

450

200

250

300

380

450

300

380

450

250

300

380

450

277 (247)

284 (254)

292 (262)

299 (269)

312 (282)

324 (294)

348 (318)

377 (347)

404 (374)

427 (397)

5.5

7.5

11

13

21

28

52

73

112

159

SDS U1200-08

Page 4: SDS U1200-08 VORTEX FLOWMETER - WordPress.com · Reynolds Number (Re) Calculation: ... Low pressure drop through body. Features SDS U1200-08 ... concentric reducer upstream of meter

¡EF73 Flangeless (Unit: kg/h)

¡EF73 Flanged (Unit: kg/h)

(Unit: m3/h)

1 bar = 0.1 MPa

Flow Rate for Saturated Steam

0.5123456789101215202530

3.13.54.34.95.45.96.36.77.17.57.88.59.4111213

21284154667991103116128140164201262323386

9,4111315171820212223242629333740

1081422072713343974595215836457068291012131916291942

2731374347525659636669748294104114

2673495106678239771130128214341585173620382489324440054774

4552627179869298104109114124137156173189

4465838501113137216291885213923922644289633984151541066787961

101115139159176192207220233245256277306350388424

1001130819092498308036574230480053685934649976269316121401498617864

174199240275305332357381403423443480530605672734

17352266330743285336633573288315929810279112571321116138210302596030945

396452546624693755812865915962100710911205137615291669

3947515675239846121401441216669189152115223383256093005336712478395905470394

75986710471198133014501559166117561846193220932313264129343203

75779897144421890123304276673200036311406054488749160576907047391835113363135132

1196136716511889209722852457261827682910304632993646416246255049

119451560322767297963673743614504455724164010707617749790944111095144769178705213023

1715196023682709300832773524375439704174436847325230597066337242

171332238032655427385269462558723568210391813101496111158130446159349207649256326305549

111.6120.4133.7143.7151.9158.9165.0170.5175.4179.9184.1191.6201.4214.9226.1235.7

0.5123456789101215202530

4.45.06.06.97.68.38.99.51011111214151719

3040587694112130147165182199234286373460549

13141720222425272830313437424751

14018326735043251259367375283291110691306170221012505

333845525863677276808390100114126137

325424620811100011871373155817431927211024763025394248665801

5361738493

101109116123129135146162184205224

527689

10061316162319272229252928283127342440184909639778979413

119136165188209228245261276290303328363414460502

118715512263296236524336501556916364703577059042

11046143941776821180

203232280320356387417444469493516559618706784856

20232643385650476223738885459697

1084311987131281540618820245253027436087

454519627717796867932993

10501104115612521384157917551916

453159198636

11303139361654519136217142428226843293983449942143549186779180810

111.6120.4133.7143.7151.9158.9165.0170.5175.4179.9184.1191.6201.4214.9226.1235.7

1525405080100150200250300

4.1123150113191428–––

35161374606136523265210

–––

0.190.411.111.804.046.8815.4

–––

6.9194472

163279625–––

2.98.9264395

164373715

11271617

24125307513

1151199545388712

1373519700

0.160.320.911.523.415.9013.525.840.658.3

4.9153661

138239544

104516482364

Flow Rate for Air and Water

EF73 Flangeless EF73 FlangedFluid Air (0 °C, atmospheric pressure) Water (20 °C) Air (0 °C, atmospheric pressure) Water (20 °C)DN

Model

Min. Max. Min. Max. Min. Max. Min. Max.

Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max.

DN 15 25 40 50 80 100 150Temp(°C)

Temp(°C)

Pressure(barg)

Pressure(barg) Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max.

DN 15 25 40 50 80 100 150 200 250 300

Min. Max.

Contact TLV for the flow rates of other fluids.

SDS U1200-08 Rev. 2/2006Specifications subject to change without notice.