Product Data Sheet 0μm

5
Kingspan KS1000/1100/1150/1200 NF Product Data Sheet Insulated Panels Denmark Wall panels with visible fix and IPN core

Transcript of Product Data Sheet 0μm

01/2021

KingspanKS1000/1100/1150/1200 NFProduct Data Sheet

Kingspan A/SMercurvej 12A9530 StøvringCVR-nr: 26065267Tel. +45 7021 7788E-mail: [email protected]

Insulated PanelsDenmark

Information about the product offer in otherscountries can be obtained from your localsales representative or on the websitewww.kingspan.com

Although Kingspan makes every efort to provide informationcontained in this publication were as accurate as possible,correct and complete, please note that its content should notbe the basis of the procedure in any particular case.Any advice, opinions, information or other content is publishedsolely based on the principle that neither the company, itsemployees or representatives, or people who contributedto the uprising of this publication, do not assume any liabilityfor its content or any damage caused in connection with this content.

Other colors from RAL and NCS palettes are also available on request, after prior consultation with Kingspan.

Wall panels with visible fix and IPN core

KINGSPAN STANDARD COLORS - EXTERIOR SIDE

Exte

rior c

oat t

ypes

(f

or g

alva

nize

d st

eel)

Poly

este

r (P

ES)

– 25μ

m

RAL 9002 RAL 7040

RAL 9006 RAL 9007 RAL 3009

RAL 7016The colors are only illustrative in nature and may differ from the actual ones.

Standard interior colors for KS1000/1100/1150/1200 NF panels are RAL9010 PES or RAL 9002 PES

Spec

trum

(PU

R) –

50μm

RAL 9010 RAL 9002 RAL 9006 RAL 9007

RAL 3009 RAL 7016 The colors are only illustrative in nature and may differ from the actual ones.

FI

FI

RAL 6020RAL 5010

CZCZ

RAL 7035RAL 1015 RAL 9010

CZ CZ

FI

FI - standard colour for panels produced in FinlandCZ - standard colour for panels produced in Czech Republic

2

Product Data SheetWall & Ceiling System

KS1000/1100/1150/1200 NF with IPN core

Cross sectionModule width - 1000/1100/1150/1200 mm

D

Prod

uct

Mod

ule

[mm

]

Insulationcore

thicknessD

[mm]

Weight[kg/m2]

Panellengths

[m] Numberof

panelsin

bundle[pcs]

Heattransfer

coefficientUd,s

[W/(m2K)]for

λ = 0,022[W/mK]

at temp. 10°C

Soundreduction

index[dB]

Fire parameters

Thic

knes

s of

stee

l fac

ings

ext.

/int

.0,

5 m

m /

0,5

m

m

Min

.(1)

Max

.

R W RA1

RA

2

Reac

tion

to fi

re

Fire

re

sist

ance

KS10

00/1

100/

1150

/120

0 N

F

1000

1150

2)

40(3) 10,23

2,0 18,0

27 0,60 24 22 21 B-s2, d0

-

1000

1100

1200 50(3) 10,49 23 0,44

25

22 21

B-s1, d0

1000

1150

2)

60 10,94 18 0,37

- - EI 15

1000

/110

0/11

502)/1

200

80 11,69 14 0,28

100 12,49 11 0,22

26

120 13,29 9 0,18

150 14,49 7 0,15

27170 15,29 7 0,13

200 16,49 5 0,11

Note:1) At the request of the ordering party (for an additional fee) it is possible to deliver shorter panels. In other cases, short sections are combined in length meeting the production requirements.2) Module 1150 mm available only for panels produced in Czech Reublic.3) NF panels in thicknesses 50 mm and 80 mm require min. quantity order 1,5 km per campaign.

Dsealing tape (waterproof)

sealing tape (airtightness)

module module

Joint detailApplication

The KS1000/1100/1150/1200 NF element is delivered with point seals in the lock. Designed for applications where you want to improve the airtightness of the panel joint.

The application of panel should be verified for each projectindividually, in order to meet the design requirements.

Technical details

3

Wall & Ceiling System

KS1000/1100/1150/1200 NF with IPN coreProduct Data Sheet

Technical dataProfilations Geometry - dimensions in [mm] Exterior Interior

M (Micro) 10 10 20

0,8

Q (Minibox)* 22

1

223

E(Euro)* 50 50

1,5

B (Mox)

1,3 50 14

6

P (plank)

1,2

6

1,2

6

200

W (wave) 50 50

2,5

D (deep) 22 222

3

F (flat)

* Profilation available only for panels produced in Czech Republic.

standard on request

Material• Exterior/Interior facings: - hot-dip zinc coated steel with a total of 275g/m2 of zinc, according EN14509; - austenitic stainless steel type 1.4301 according to EN 10 088;• Insulation core: - insulation core IPN closed-cell foam;

4

Product Data SheetWall & Ceiling System

KS1000/1100/1150/1200 NF with IPN core

Exterior Coating Options• Polyester - for the environment category up to C3; • Foodsafe (PVC) - for the environment category up to A3*; • INOX - for the environment category up to C5; • Spectrum (PU) - for the environment category up to C5;

Interior Coating Options• Polyester - for the environment category up to C2; • Foodsafe (PVC) - for the environment category up to C4; • INOX - for the environment category up to C5; • Spectrum (PU) - for the environment category up to C5;

*Exterior coating allowed only for partition walls of the building.

Reference documentsKS1000/1100/1150/1200 NF sandwich panels are manufactured in accordance with the EN 14 509 and CE marked.

QualityKingspan insulating sandwich panels are made from the highest quality materials, using the latest manufacturing technology,meet the stringent quality control requirements, meet ISO 9001:2015 standards and guarantee long service life and reliability.

Guarantees & WarrantiesThe Kingspan guarantees are individually assessed for each project, especially depending on the aggressiveness of the environmentand the type of surface treatment chosen.

Factory Applied Side Joint TapeKS1000/1100/1150/1200 NF panel side joints have factory applied anticondensation seals fitten into the groove to automaticly seal the joint between panels.

01/2021

KingspanKS1000/1100/1150/1200 NFProduct Data Sheet

Kingspan A/SMercurvej 12A9530 StøvringCVR-nr: 26065267Tel. +45 7021 7788E-mail: [email protected]

Insulated PanelsDenmark

Information about the product offer in otherscountries can be obtained from your localsales representative or on the websitewww.kingspan.com

Although Kingspan makes every efort to provide informationcontained in this publication were as accurate as possible,correct and complete, please note that its content should notbe the basis of the procedure in any particular case.Any advice, opinions, information or other content is publishedsolely based on the principle that neither the company, itsemployees or representatives, or people who contributedto the uprising of this publication, do not assume any liabilityfor its content or any damage caused in connection with this content.

Other colors from RAL and NCS palettes are also available on request, after prior consultation with Kingspan.

Wall panels with visible fix and IPN core

KINGSPAN STANDARD COLORS - EXTERIOR SIDEEx

terio

r coa

t typ

es

(for

gal

vani

zed

stee

l)

Poly

este

r (P

ES)

– 25μ

m

RAL 9002 RAL 7040

RAL 9006 RAL 9007 RAL 3009

RAL 7016The colors are only illustrative in nature and may differ from the actual ones.

Standard interior colors for KS1000/1100/1150/1200 NF panels are RAL9010 PES or RAL 9002 PES

Spec

trum

(PU

R) –

50μm

RAL 9010 RAL 9002 RAL 9006 RAL 9007

RAL 3009 RAL 7016 The colors are only illustrative in nature and may differ from the actual ones.

FI

FI

RAL 6020RAL 5010

CZCZ

RAL 7035RAL 1015 RAL 9010

CZ CZ

FI