MIXING EQUIPMENT Co., Inc.
Transcript of MIXING EQUIPMENT Co., Inc.
TWO CHAMBER SIZES 4" χ 3%" χ AW - 4" χ 33Λ" χ 9"
OPERATING TEMPERATURE 2150°F (1177°C)
120, 208 and 240 VOLT MODELS
EMBEDDED HEATING ELEMENTS ~» WELDED STEEl CONSTRUCTION HEAT-RESISTANT ENAMEL FINISH
COMPACT - CONVENIENT for general lab work and process control.
TYPE 2000 w i t h automat ic electronic temperature cont ro l . Prices - $247.50 to $257.50.
TYPE 1500
with stepless input temperature control.
Prices — $145 to $165.
Write, wire, or phone for complete information and name of nearest dealer.
THERMOLYNE CORPORATION 2555 KERPER BLVD.
Dubuque, Iowa, U. S. A. Dept. 4 7 8
Circle No. 80 on Readers' Service Card
Product Capsules
Gases. Custom blended radioactive mixtures. 190
Gases. Lung diffusion mixtures for single breath and continuous tests.
158
Gases. For x-ray fluorescence spectroscopy and nuclear counters. 75
Gases. Zero gases for use with flame ionization instruments. 204
Gases. To calibrate oxygen analyzers from 1 p.p.m. to 99.5% oxygen. 201
Gases. Mixtures for use with halogen and helium leak detectors. 193
Gases. Doping gas. Mixtures with phosphine, arsine, or diborane. 179
Gases. Carrier gas is 5% methane and 95% argon. 154
Gases. Hydrocarbon mixtures for calibration of flame ionization. 177
Gases. Mixtures for controlling environment for culture studies. 166
Grease. Has low vapor pressure for high vacuum work. 35
Hoods. 6-page folder describes stock fume hoods. 184
Hoods. Stone models are non-absorbent, liquid tight. 5
Hoods. Fiberglass models can be easily installed. 14
Hot Plates. Top plate reaches maximum temp. (950° F.) in 7 minutes. 42
Impactors. For measuring particle size distribution of aerosols. 141
Instruments. For chromatography, zone and gel electrophoresis. 116
Integrators. Disc model installs on standard strip chart. 45
Integrators. Data on fully automated digital model. 216
Ion-exchangers. Literature on cellulose paper. 28
Ion-exchangers. For chromatography of labile compounds. 79
Lamps. High-intensity mercury vapor arc models for photochemistry. 51
Materials. For use in quantitative spectrochemical analysis. 121
Microscopes. Stereo model has easily interchangeable eyepieces. 134
Microscopes. Electron models have 10 angstron resolution or better. 149
Mixers. Model has variable d.c. speeds from a.c. lines. 62
HOW VERSATILE CAN A MIXER BE? If you had to standardize on just one kind of mixer in your laboratory, this gear drive unit would be a good choice.
You can mix almost anything* from molasses to methanol wi th the LIGHTISH Ν Mixer, Model V. It weighs only seven and a half pounds, but is so ruggedly built you can run it for weeks on end. It operates on AC or DC.
You can set it to give just the action you want; a separate rheostat varies speed from half to full.
And you can purchase it in a gear ratio that matches the kinds of mixing you do most; 1800 rpm for general service, 1000 or 600 rpm for viscous fluids. Fully guaranteed. Supplied with removable 12-inch shaft and 2-inch propeller in 316 stainless steel or Monel, tank clamp or ring-stand clamp in bronze. Order from your supply house, or write us. Specify LIGHTNIN Model V Mixer:
With semi-enclosed motor, AC-DC $72.00
Rheostat, 150-watt, 150-ohm $15.90
•If you're mixing volatile liquids, you'd be better off with our Model 10X with explosion-proof motor, or with compressed-air-driven Model ARL To get a bulletin describing these and other heavy-duty LIGHTNIN Mixers for the laboratory, write us or check the reader service card.
THERMOLYNE
Lightnin® Mixers MIXING EQUIPMENT Co., Inc. 160-g Mt. Read Blvd., Rochester 3, Ν. Υ. In Canada: Greey Mixing Equipment, Ltd.,
100 Miranda Ave., Toronto 19, Ont. In Europe: Lightnin Mixers, Ltd.
Poynton, Cheshire, England Circle No. 61 on Readers' Service Card
VOL. 36, NO. 8, JULY 1964 • 127 A