18
L L und und Y Y ork ork C C ologne ologne Ca Ca lorimeter lorimeter • present status • test results • with AGATA@GSI Thanks to Andreas Wendt !!

Transcript of Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas...

Page 1: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

LLundund

YYorkork

CCologneologne

CaCalorimeterlorimeter

• present status• test results• with AGATA@GSI

Thanks to Andreas Wendt !!

Page 2: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

RIB vom FRS

Sekundary target

Diamond or Plastic

Time-of-Flight (ΔE, x, y)

CsIDSSD DSSD

(E)(x, y)

Reminder: Detection principle

AGATA @ GSI meetingMay 4th 2010, Is

University of CologneAndreas Wendt

LYCCA-0 ΔE-E-hardware:12 DSSDs12x9 CsI (long/short)

University of YorkMike Bentley

Page 3: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

Reminder: Detection principle

AGATA @ GSI meetingMay 4th 2010, Is

University of CologneAndreas Wendt

University of YorkMike Bentley

Double fragmentation reaction: 40Ca (420 MeV/u) + 9Be (4.0 g/cm2) → 37Ca (196 MeV/u ) + 9Be (0.7 g/cm2)

37Ca (85 %)2*103 p/sec

36K (10 %)

Selection by FRS Selection by CATE (Energy-loss/Energy)

Page 4: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

Reminder: Detection principle

AGATA @ GSI meetingMay 4th 2010, Is

University of CologneAndreas Wendt

University of YorkMike Bentley

Mass Selection by Time-of-Flight and EnergySimulation: M.J.Taylor et al

(assumes 3m flight path and 50ps FWHM))

Expected performance: Mass identification (if ~50ps FWHM timing achieved)

• Mass separation up to A~70• Some mass information at A~100• Depends on specific case (needs simulation)

Page 5: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

LYCCA chamber: • up to 72 KEL-Feethroughs• 32 SHV+Lemo-FT

Status: mechanics

Preparation and storage @ X7

Vacuum test @ cologne (5·10-5mbar)Feb. 2010

AGATA @ GSI meetingApril 30th 2010, GSI

Used as TKE-detector(for S272 @ S4)Mar./Apr. 2010

University of CologneAndreas Wendt

University of YorkMike Bentley

Page 6: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

ΔE-detector status:

• 10 DSSDs ready!

• 8 @ Lund, awaiting bonding

[2 ΔE-detectors tested in-beam]

- 32 x 32 strips - Active area 58 x 58 mm² - Interstrip distance : 75 μm - thickness: 300 μm

12 ΔE-detector needed for LYCCA-0

Status: Silicon detectors

Ordering status:

• 18 DSSDs delivered • all T-boards delivered • connectors on-hand

AGATA @ GSI meetingApril 30th 2010, GSI

University of CologneAndreas Wendt

University of YorkMike Bentley

Page 7: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

„short“ crystals (13+7mm)• 2 E-Blocks assembled, tested• crystals for another 4 blocks available• mechanics for 12 E-Blocks available

„long“ crystals (33+7mm)• crystals for 13 E-Blocks on hand• 4 E-Blocks (used for S272) ready

40

.0

short

long

Status: CsI-scintillators

AGATA @ GSI meetingApril 30th 2010, GSI

University of CologneAndreas Wendt

University of YorkMike Bentley

Page 8: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

Status: Time-of-flight PLASTIC

AGATA @ GSI meetingApril 30th 2010, GSI

University of CologneAndreas Wendt

University of YorkMike Bentley

Detector constructed for ToF-stop- New one being constructed for ToF-start• Stop-detector tested in-beam (GSI)• 300 MeV/u 58Ni

Robert Hoischen et al (Lund/GSI)

SC42 180ps FWHM

Plastic ToF 40ps FWHM

Page 9: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

Status: Time-of-flight DIAMOND

AGATA @ GSI meetingApril 30th 2010, GSI

University of CologneAndreas Wendt

University of YorkMike Bentley

Start-detector: 9 x PC 2x2cm wafers (4 strips)• 36 detector segments• Prototype wafers fabricated and tested• 5 wafers will be put in detector in June/July 2010• Fast DBAIV current pre-amps + V1290 TDC

First tests TEXAS A&M March/April 2010• ~35MeV/u 40Ar beam• ~20 MeV/u 20Ne beam

Page 10: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

Status: Time-of-flight DIAMOND

AGATA @ GSI meetingApril 30th 2010, GSI

University of CologneAndreas Wendt

University of YorkMike Bentley

Best achieved ~90ps FWHM

~20 MeV/u 20Ne beam

20Ne 16OBUT• …problems with detector reliability (HV breakdown, PCB?) • …and fabrication consistency.

~35MeV/u 40Ar beam

Best ~90ps FWHM

Page 11: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

Time-of-flight for AGATA

AGATA @ GSI meetingApril 30th 2010, GSI

University of CologneAndreas Wendt

University of YorkMike Bentley

Secondary target

Plastic

Time-of-Flight (ΔE, x, y)

CsIDSSD DSSD

(E)(x, y)

Diamond Plastic

Two options:• Diamond start AT TARGET (~70ps FWHM required) and Plastic stop (50ps ideal)OR.. • Plastic start UPSTREAM OF TARGET (~50ps FWHM required) and Plastic stop (50ps ideal)

THESE will be tested in June/July 2010

Page 12: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

200 MeV:• 18 available

4 GeV:• prototype tested• 22 available

LYCCA-0: DSSD 384ch + CsI 108ch

→ 12 + 4 PreAmps

16ch 9ch

9ch 9ch 9ch

9ch 9ch 9ch

9ch

9ch

9ch

9ch9ch

16ch

16ch16ch

16ch

16ch

16ch

16ch

64ch

64ch

64ch

64ch

Status: Electronics

9ch

9ch

64ch+9ch

9ch

LYCCA for S272: DSSD 64ch + CsI 36ch

→ 2 + 2 PreAmps

(x2 / x4 join-board)32ch - CSP

AGATA @ GSI meetingApril 30th 2010, GSI

University of CologneAndreas Wendt

University of YorkMike Bentley

Page 13: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

FWHM: 41 keV @ 5484 keV~ 0,75 % (241Am) 6 cm

Test results: DSSD off-beam

Test chamber

AGATA @ GSI meetingApril 30th 2010, GSI

University of CologneAndreas Wendt

University of YorkMike Bentley

Page 14: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

Test results: LYCCA @ S272

AGATA @ GSI meetingApril 30th 2010, GSI

LE 3 LE 4

LE 1LE 2

DSSD

Top-left: Hit pattern DSSDTop-right: HP of DSSD, if LE2(4) is hit Bottom-left: HP of DSSD, if LE2(5) is hitBottom-right: HP of CsI-crystals

total

6 7 8

3 4 5

0 1 2

Labeling of crystals

University of CologneAndreas Wendt

University of YorkMike Bentley

Page 15: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

Test results: LYCCA @ S272

AGATA @ GSI meetingApril 30th 2010, GSI

ΔE(Σ p-side)

TKE (Σ LE2)

Not calibrated yet

Gen.

ΔE (p2)

TKE (LE2(6))

University of CologneAndreas Wendt

University of YorkMike Bentley

Page 16: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

Jun./July 2010 Sep. 2010

Timeline

Mar./Apr. 2010

LYCCA-0Comissioning

Pre

Sp

ec I

@ F

RS

LYCCA-00@ S272

AGATA @ GSI meetingApril 30th 2010, GSI

Photomontage: view on LYCCA-0

University of CologneAndreas Wendt

University of YorkMike Bentley

Page 17: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

LYCCA Simulations

AGATA @ GSI meetingApril 30th 2010, GSI

University of CologneAndreas Wendt

University of YorkMike Bentley

NIM A 606 (2009) 589-597

LYCCA-0 Simulations• Full MOCADI event generator (realistic beam and reaction profile)• Full implementation of LYCCA-0 detectors• Time-of-flight options (both) now included• Variable parameters (resolutions, flight path etc)

VISIT:

LYCCA page at Lund University

(type “LYCCA” in Google) !!

Page 18: Lund Lund York Cologne Calorimeter present status test results with AGATA@GSI Thanks to Andreas Wendt !!

University of CologneAndreas Wendt

LYCCA-Collaboration

AGATA @ GSI meetingApril 30th 2010, GSI

P. Reiter, A. Wendt, C. Goergen, G. Pascovici, J. Taprogge, S. Thiel

University of Cologne

D. Rudolph, P. Golubev, R. Hoischen Lund University

M. A. Bentley, M. Taylor, B.S.Nara Singh, S.P. Fox

University of York

J. Gerl, GSI PreSpec Collaboration