ISOLATING JOINT GENERAL DATA SHEET - Alfa … According To ASME IX - API 1104 > 200 M Ω @ 1000 Volt...
Click here to load reader
Transcript of ISOLATING JOINT GENERAL DATA SHEET - Alfa … According To ASME IX - API 1104 > 200 M Ω @ 1000 Volt...
ADDITIONAL DESIGN DETAIL
ALLOWABLE LOADS
ITEM
TYPE
DESIGN CODE
DESIGN PRESSURE (BarG)
DESIGN TEMPERATURE (°C)
RATING (ASME/ANSI #) Class
ENDS "BW"
DESIGN FACTOR
CONNECTION PIPE DN "D" (mm/in.)
CONNECTION PIPE THK "t" (mm/in.)JOINT OVERALL LENGTH
"OL"(mm) "T" PIPELINE ( ISO3183 - API 5L
)"S-L-G" BODY PARTS
"F" ISOLATING ELEMENTS
"OR" GASKET
"Si" BACK SEAL
"R" FILLER ISOLATOR
"P" CABLE LUGS M10
"DFT1" INTERNAL COATING
"DFT2" EXTERNAL COATING
INSTALLATION
HYDROSTATIC TEST
DIELECTRIC TEST
ELECTRIC INSULATION TEST
NDE TEST
WELDS
CERTIFICATION
INSPECTION & TEST/ACCEPTANCE
SOUR SERVICE
CORROSION ALLOWANCE
SERVICE
PIPING CLASSE
QUANTITY
NOTES :
6) Cables Lugs will be installed on Isolating Joint only if request from Cathodic Protection Requirements.
W1-W2-W3: MT & UT, Bevel Ends MT - According to ASME V
As per Customer Requirements
As per Customer Requirements
1) A Length of 50 mm at each end shall be left uncoated to allow welding
YES NO
As per Customer Requirements
3) All pressure containing steel parts shall be in strict accordance with NACE MR-0175/ISO 15156 (latest edition).
4) This information is approximate. The exact value shall be checked and specified during the PO Stage
Standard Application 0 to 90° - Special Application -173 to 180°C
Double “O” Ring ASTM D 2000 FPM
(Viton)
Silicon Neutral Low Module
Epoxy Resin Cold Cured
EN 10025 235JR (Carbon Steel)
W1-W2-W3: According To ASME IX - API 1104
> 200 MΩ @ 1000 Volt DC ( Special > 100 GΩ @ 5000 Volt DC )
2) All pressure containing materials including steel parts, insulating materials, seal gaskets and internal coating are suitable for resistance to H2S environments.
Gas, Hydrocarbons, Oil, Chemical Fluids, Water,Toxic, ETC
EN 10204 - 3.1 ( EN 10204 - 3.2 if request )
6
Manufacturer Standard / Customer Applicable Requirements
1.5 Times the Design Pressure ( Or as per Customer Requirements )
ABOVEGROUND / UNDERGROUND/SUBSEA
1.5 to 5 KV @ 1 minute AC 50÷60 Hz (Special 20 KV @ 1 minute AC
50÷60 Hz)
1, 2Amine Cure Epoxy Resin 200÷500
microns1, 5
2
5
5
150 to 12000 (OVER 3000 INSULATION JOINT + EXTENSION PIPE ) 1, 4
MATERIAL
All Grade + low Alloy & Alloy Steel 2, 3
ASTM / ASME / UNS / EN Materials 2, 3
NEMA G10 - ASTM D709 2
Amine Cure Epoxy Resin 200÷500
microns
Standard Application 0.5 (Special Project Requirements 0.2 to 0.72 )
15 to 3000 / 1/2" to 120"
2.7 to 152.4 / 0.154" to 6"
6 to 1034,5
150 to 2500 "ANSI/ASA" - 3000 to 15000 "API"
BUTT WELDED - API 5L / B16.25 / B16.5 / MSS SP75
5) Material not in contact to the fluid
DESCRIPTION NOTES
INSULATING JOINTS, Monolithic Type
ASME B 31.3 - ASME B 31.4 - ASME B 31.8 - ASME VIII Div.I Appx. 2
ISOLATING JOINT GENERAL DATA SHEET
Standard Total Design Load 50 % Pipe SMYS
(Special Total Design Load 75 % Pipe SMYS)
(Special Total Design Load 90 % Pipe SMYS)
(Special Total Design Load 95 % Pipe SMYS)
G S F P OR L R Si
W2
W3
ØA
±0
.5%
ØB
±1%
=
C ± 50
D ± 1% =
50 50
DF
T1
Deta
il 1
TS
W1
D
FT
2
S1
-12%
+15%
TL
S2
-12
% +
15
%
Iden
tification
Lable