IEC Antenna Connectors DIN 45325, 75Ω - · PDF fileIEC Antenna Connectors DIN 45325,...
Transcript of IEC Antenna Connectors DIN 45325, 75Ω - · PDF fileIEC Antenna Connectors DIN 45325,...
Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com378
IEC Antenna Connectors DIN 45325, 75Ω
51IEC Antenna Connectors DIN 45325, 75Ω
Interface Dimensions IEC Antenna ConnectorsDIN 45325, 75 Ω
Code 27
IEC Antenna Connectors DIN 45325, 75 Ω
REFERENCE PLANE
Referenzebene
REFERENCE PLANE
Referenzebene
MALE
SteckerFEMALEKuppler
BA BC A
E
DE
D
F
C
Male | Stecker Female | Kuppler
dimension [mm] min. max. min. max.
A 2.30 2.38 1)
B 8.50 1)
C 9.475 9.575 13.00 nom.
D 0.40 1.20 2.20 nom.
E 4.95 5.05 6.40 6.80
F 9.10
1) resilient, dimension to meet electrical and mechanical requirements
Snap-on coaxial connectors with excellent electrical and mechanical characteristics for applications up to 1 GHz, especially radio broadcasting, TV antenna connections or testand measuring instruments.
Koaxial-Steckverbinder mit Schnappverschluss und sehr guten elektrischen und mechanischen Eigenschaften für Anwendungen bis 1 GHz, insbesondere Anschluss von Rund-funk- oder TV-Antennen, Mess- und Prüfgeräten.
FeaturesInterface according to MIL-DTL-3643BFrequency range DC to 4 GHzWorking voltage 2500 V rmsImpedance 50 Ω Screw-on coupling
Connectors are available on request
379Rosenberger Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com
IEC Antenna Connectors DIN 45325, 75Ω
Oth
ers
Technology
Technical Data IEC Antenna Connectors DIN 45325, 75 Ω
Code 27
Applicable standards | Anwendbare Normen
Interface according to | Interface gemäß DIN 45325, IEC 61169-2
Quality tested according to | Qualitätsprüfung gemäß IEC 60169
Electrical data | Elektrische Daten
Impedance | Wellenwiderstand 75 Ω
Frequency range | Frequenzbereich DC to 1.75 GHz
Return loss (cable connector straight) | Rückflussdämpfung (Kabelsteckverbinder gerade) ≥ 16 dB (typ.)
Insertion loss | Dämpfung ≤ 0.1 x √f(GHz) dB
Insulation resistance | Isolationswiderstand ≥ 1 GΩ
Center contact resistance | Übergangswiderstand Innenleiter ≤ 10 mΩ
Outer contact resistance | Übergangswiderstand Außenleiter ≤ 5 mΩ
Test voltage | Prüfspannung 1000 V rms
RF-leakage | Schirmdämpfung ≥ 75 dB @ DC to 470 MHz≥ 65 dB @ 470 MHz to 1.75 GHz
Mechanical data | Mechanische Daten
Mating cycles | Steckzyklen ≥ 500
Environmental data | Umweltdaten
Temperature range | Temperaturbereich -25 °C to +70 °C
Dry heat | Trockene Wärme IEC 60169-1, Sub-clause 16.2.1
Damp heat | Feuchte Wärme IEC 60169-1, Sub-clause 16.2.2
Climatic sequence | Klimasequenz IEC 60169-1, Sub-clause 16.2, 25/70/21
Max. soldering temperature (PCB connectors) | Max. Löttemperatur (Leiterplattensteckverbinder) IEC 61760-1, +260 °C for 10 sec.
Materials | Materialien
Spring loaded contact parts | Federnde Kontaktteile CuBe, Ag plating
Center contact | Innenleiter CuZn, Ag plating
Outer contact | Außenleiter CuZn, Ni plating
Crimping ferrule | Crimphülse Copper alloy, Ni plating
Dielectric | Dielektrikum PTFE
Gasket | Dichtung Rubber
Rosenberger-connectors fulfill in principle the indicated data of the Technical Data.Individual values of connectors may deviate depending upon application, design,type of cable, assembly method and execution. Specific data sheets for particularproducts can be provided on request from your Rosenberger sales partner.
Rosenberger-Steckverbinder erfüllen grundsätzlich die in den Technischen Datenangegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -aus-führung können einzelne Werte von Steckverbindern hiervon abweichen. SpezifischeDatenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem Rosenber-ger-Ansprechpartner.
Connectors are available on request. Steckverbinder auf Anfrage erhältlich.