DRY WASH - Eurosets - Medical Devices WITHOUT DRY WASH WITH DRY WASH Volume in the Reservoir =...

4
THE NEW FRONTIER IN THE ORTHOPAEDIC POST-OP AUTOTRANSFUSION DRY WASH

Transcript of DRY WASH - Eurosets - Medical Devices WITHOUT DRY WASH WITH DRY WASH Volume in the Reservoir =...

THE NEW FRONTIER IN THE ORTHOPAEDIC POST-OP

AUTOTRANSFUSION

DRY WASH

MACROFILTER

QUALITY SENSOR

REINFUSION BAG

VACUUM GENERATOR

SUPERNATANT SEPARATORThe lipidic particles are blocked in the reservoir

40μm MICROAGGREGATES FILTER

CONNECTION TO DRAINAGE

1 Holding system (hook)2 Open/close button3 RBC’s sensor + automatic clamp4 Hook for transfer bag5 Procedure key-pad

QUALITY SENSOR DESCRIPTION

THE NEW FRONTIER IN THE ORTHOPAEDIC POST-OP AUTOTRANSFUSIONTHE DRY WASH IS AN INNOVATIVE SYSTEM, ASSOCIATED WITH ORTHO P.A.S. DRY WASH, CAPABLE TO REMOVE AUTOMATICALLY THE ENTIRE SUPERNATANT LAYER, ELIMINATING THE MAjOR CONCENTRATION OF HARMFUL SUBSTANCES, THUS REDUCING THE LIkELIHOOD OF TRANSFUSION REACTION.

THE DRY WASH SYSTEM•Preventsthespreadofinfectiveandimmunological complications.•Makesthebloodimmediatelyavailableforreinfusion.•Preventsanyallergicreactioninthereceivingpatient.•Isapprovedbyallreligiousconfessions(closedcircuit).•Eliminatesthemajorconcentrationofharmfulsubstances.

MAIN CHARACTERISTICS•Fullsterilityoftherecoveredandsubsequently reinfused blood is maintained (no contact with non-sterile outside air).•Completeprotectionfortheoperatorandretention of blood sterility in the event of the device overturning or falling.•Safeguardingagainsttherecoveredblood contaminating the environment.•Possibilityofreinfusionalsoduringtherecoveryphase.•Highfiltrationefficacyofthebloodfiltersused.•Variablesupernatantlayerandfatautomaticallyblock in the reservoir.•Protectionofthemulti-usecomponents(suctionpump).•Easeofuse;Cost-effective.

DESCRIPTIONWhile transferring the blood collected from the reservoir to the reinfusion bag , most of the “no wash devices” allowtotransfereverything(Bloodshed,FPH,Fat,etc);othersdevicesareequippedwithsupernatantseparatorguaranteeingthatafixedvolume(i.e.50ml)remainsinthe reservoir, keeping:•theentirelipidslayer(inthereservoir);•partiallytheSupernatantlayer(inthereservoir).

The fixed volume might not guarantee a completeremoval of the entire Supernatant layer, due to Patients’ variable exudated volume.Thanks to the electronic sensor, placed between reservoir and reinfusion bag, the entire VARIABLE SUPERNATANT and lipids layer are not transferred to the reinfusion bag.Thebloodisreinfusedthroughthe40μmGOCCIAfilterinordertopreventanyrisktothepatient(forexample,pulmonary microembolism caused by circulating microaggregates).

DRY WASH

1

2 3

4

5

PRE-REINFUSION

WITHOUT DRY WASH

WITH DRY WASH

VolumeintheReservoir=550ml.500mltransferredinthereinfusionbag (including the supernatant). 50ml remaining in the reservoir, assurethat lipids are KEPT in the reservoir andNOTREINFUSED

VolumeintheReservoir=550mlThanks to the electronic sensor all supernatant layer is kept inside the reservoir (300ml)

VACUUM GENERATORSThevacuumsourceissettableandcontinuousandsafeguardsagainstexcessivebleedingandpossibleformationofhaematomas.The vacuum oscillation, i.e. the alternation of high and low vacuum, facilitates haemostasis of the wound without the risk of haematoma formation.Thecollectedbloodspontaneouslydefibrinatesuponcontactwiththetissuesbeforeflowingfromthedrainages,therefore,no anticoagulant solution needs to be used.

PROCEDURE DATA AREA

PROCEDURE DATA AREATAPVACUUM INDICATOR

The tap allows three operating modes: •Operationconnecteddirectlytothe vacuum generator (“suction” position)

•Operationbygravity (“vent” position)

•Redonoperation (“pause” position)

Thisisjustanexample,thesupernatantlayerdependsonPatient’sHCTandinflammatoryresponce.

550ml

50ml

500ml250ml

300ml

EASY VACUUMGENERATORRECHARGEABLERechargeable batteries only

EASY VACUUMGENERATORDisposablebatteries only

MANUALSUCTION PUMPWith graduated scale

VACUUMGENERATORRechargeable batteriesDisposablebatteriesMainpowersupply

CODE DESCRIPTION N°/PACk

EU3835 QualitysensorDryWash(reusable) 01

EU3885 OrthoP.A.S.DryWashcompleteset(single use) 05

EU3889 OrthoP.A.S.DryWashsetwithpre-connectedbag,without40μmGocciafilter 05

EU3079 40μmGocciafilterwithreinfusionline 50

EU3856 OrthoP.A.S.DryWashunit 05

EU3188 Reinfusionset(750mlbag+40μmGocciafilter) 10

EU3773 NewMicroVacuumGenerator“blue” (reusable) 01

EU3825 EasyVacuumGeneratorRechargeable“orange” (reusable) 01

EU3215 EasyMicroVacuumGenerator“green” (reusable) 01

EU3855 Manualsuctionpumpwithgraduatedscale(single use) 10

DistribuitodaDistributedbyDistribuèparVertriebDistribuidopor

Prodotto daManufacturedbyFabriquèparHerstellerFabricadopor

Eurosets s.r.l.Strada Statale 12, n°14341036 Medolla (MO) ItalyTel: +39 0535 660311Fax: +39 0535 51248E-mail: [email protected]

Rev.1/2018

©Copyright2018byEurosetsS.r.l.-Catalogue,products,picturesmaydifferentiatefromtheactualproductappearance.Specificationsaresubjecttochangewithoutpriornotice.