COMPORTAMENTO DELLE STRUTTURE PREFABBRICATE IN … · 450 mm 3 0 0 8φ16 12.00 m 6.00 25 getto in...
Transcript of COMPORTAMENTO DELLE STRUTTURE PREFABBRICATE IN … · 450 mm 3 0 0 8φ16 12.00 m 6.00 25 getto in...
1
1
ASSOBETONASSOCIAZZIONE NAZIONALE
INDUSTRIE MANUFATTI CEMENTIZI
L’AQUILA – 14.07.2009…
COMPORTAMENTODELLE STRUTTURE PREFABBRICATE
IN ZONA SISMICA
Giandomenico Toniolo2
POSIZIONE DI AVANGUARDIAPER QUALITA’ E PRESTAZIONI
….
ANCHE IN CAMPO SISMICOGRAZIE ALL’IMPEGNO NELLA RICERCA
3
15 ANNI DI RICERCHE SU PREFABBRICATI
1A FASE – PROVE PILASTRI ASSOBETON
2A FASE – ANALISI NUMERICHE STRUTTURE
3A FASE – PROVE “ECOLEADER” SU STRUTTURE
4A FASE – GROWTH “PRECAST STRUCTURES EC8”
5A FASE – RELUIS VULNERABILITA’ EDIFICI ESISTENTI
6A FASE – “SAFECAST” CONNESSIONI SISMICHE
4
PREMESSA
TERREMOTO FRIULI 1976
RILIEVO ASSOBETONSU ≈60 EDIFICI INDUSTRIALI
UN CROLLO DI TRAVE USCITA DALL’APPOGGIO
(PIU’ SEGNI DI GRANDI SPOSTAMENTI)
NO APPOGGI AD ATTRITO IN ZONA SISMICA
5
1° FASE: 1992-1996 (ENV 1998)
TASSIOS: CONVEGNO UNI-ASSOBETON 1993
ENV EC8 1994/1995: PRIME NORME SPECIFICHE
IMPEGNO DI PROVE SU PILASTRI
PROVE ASSOBETON 1994/96 A ISPRA
CALIBRAZIONE MODELLI DI CALCOLO
6
PROVE ASSOBETON 1994/96LABORATORIO
ELSA JRC - ISPRA
20 PROVE CICLICHE+ 8 PSEUDODINAMICHE
COORDINAMENTOPOLITECNICO DI MILANO
2
7
CICLI F-d (1° ORDINE)
ν = Na/Nr = 0,16-300 -200 -100 0 100 200 300
displacement d (mm)
-60
-50
-40
-30
-20
-10
0
10
20
30
40
50
60
forc
e H
(kN
)
PROVA B3 N=327 kN23.6.95 ν=0.16
-300 -200 -100 0 100 200 300
displacement d (mm)
-60
-50
-40
-30
-20
-10
0
10
20
30
40
50
60
forc
e V
(kN
)
PROVA B3 N=327 kN23.6.95 ν=0.16
CICLI V-d (2° ORDINE)
8
ENERGIA DISSIPATA
ENERGIA RELATIVA
-4 -3 -2 -1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16semicicli
0
2000
4000
6000
8000
10000
ener
gia
diss
ipat
a (k
N m
m)
PROVA B3 N=327 kN23.6.95 ν=0.16
1 2 3 4 5 6 7 8 9 1011 12 13 14 15 16semicicli
0.0
0.5
1.0
valo
ri ad
imen
sion
ali
0.0
0.5
1.0
9
RISULTATI
- OTTIMO COMPORTAMENTO (DISSIPAZIONE u = 0,4)
- SIMILI A GETTATI IN OPERA (SENZA RIPRESE: CON STAFFE STABILI)
- IMPORTANZA DELLA SPAZIATURAFITTA DELLE STAFFE
- DUTTILITA’ TRA 3,5 E 4,5(SECONDO PREVISIONI NORMATIVE TELAI)
10
2° FASE: 1996-2000: ( ENV → EN )
ENV 1998: PREFABBRICATO PENALIZZATORISPETTO A GETTATO-IN-OPERA
RICERCA ASSOBETON – POLIMI
ANALISI NUMERICHE COMPARATIVESU BASI PROBABILISTICHE
PREFABBRICATO = GETTATO IN OPERA
11
CASO DEI PREFABRICATI
M = F h2 ZONE CRITICHE GRANDI
12
TELAIO GETTATO IN OPERA
m= F h / 2 = M / 24 ZONE CRITICHE PICCOLE
h
u
u
u
u
m m
m m
FF
3
13
VOLUME DISSIPATIVO EGUALE
2 U ≈ 4 u
EGUALE DISSIPAZIONE ……………….. EGUALE FORZA SISMICA
DA DIMOSTRARE
14
STATISTICA CON MOLTE ANALISIANALISI DINAMICA NON LINEARE
INTENSITA’ INCREMENTATO A COLLASSO
CONFRONTO CON NORMATIVA (EC8)
“SPERIMENTAZIONE” NUMERICA
15
MOLTE ANALISI
CON DIVERSI ACCELEROGRAMMI
SCELTA:
- ACCELEROGRAMMI REGISTRATI
- ACCELEROGRAMMI ARTIFICIALI
16
REGISTRATI
(a)
(b)
(c)
17
ARTIFICIALI
-1.0-0.8-0.6-0.4-0.20.00.20.40.60.81.0
0 5 10 15 20 25 30 35 40 45 50
Time [sec]
Acc
eler
atio
n a
(t)/P
GA
-1.0-0.8-0.6-0.4-0.20.0
0.20.40.60.81.0
0 5 10 15 20 25 30 35 40 45 50
Time [sec]
Acc
eler
atio
n a
(t)/P
GA
-1.0-0.8-0.6-0.4-0.20.0
0.20.40.60.81.0
0 5 10 15 20 25 30 35 40 45 50
Time [sec]
Acc
eler
atio
n a
(t)/P
GA
0.0
0.5
1.0
1.5
2.0
2.5
3.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
Period [sec]
Acc
eler
atio
n a m
ax/P
GA
0.0
0.5
1.0
1.5
2.0
2.5
3.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
Period [sec]
Acc
eler
atio
n a
max
/PG
A
0.0
0.5
1.0
1.5
2.0
2.5
3.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
Period [sec]
Acc
eler
atio
n a m
ax/P
GA
18
ANALISI DINAMICA NON LINEARE
INTEGRAZIONE DELL’EQUAZIONE DEL MOTO
CON MODELLO CICLICO DI DANNEGGIAMENTO
DELLE SEZIONI CRITICHE IN CEMENTO ARMATO
A SIMULAZIONE DEL COMPORTAMENTO VIBRATORIO
4
19
PROCESSO INCREMENTALE
αg = 0,30 - 0,35 - 0,40 - αgmax
-300
-200
-100
0
100
200
300
400
500
600
700
0 5 10 15 20 25 30 35 40 45 50
Time t [sec]
Dis
plac
emen
t d [m
m]
α g max=1.25 (κ =1.54)
20
ESEMPIO
300 mm
300
8φ14
12.00 m
6.00
25
450 mm
300
8φ16
12.00 m
6.00
25
GETTO IN OPERA PREFABBRICATO
21
65 ACCELEROGRAMMI REGISTRATI(CON fk E q=4,5)
MONOLITICO INCERNIERATO
BUONA CONCORDANZA CON NORMATIVA
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0
Overstrength κ
Prob
abili
ty D
ensi
ty f
()
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0
Overstrength κ
Prob
abili
ty D
ensi
ty f
()
22
400 ACCELEROGRAMMI ARTIFICIALI(CON fk E q=5,0)
MONOLITICO INCERNIERATO
BUONA CONCORDANZA CON NORMATIVA
0.00
0.50
1.00
1.50
2.00
2.50
0.60 0.90 1.20 1.50 1.80 2.10 2.40
Overstrength κ
Prob
abili
ty D
ensi
ty f
()
0.00
0.50
1.00
1.50
2.00
2.50
0.60 0.90 1.20 1.50 1.80 2.10 2.40
Overstrength κ
Prob
abili
ty D
ensi
ty f
()
23
1000 ACCELEROGRAMMI ARTIFICIALI(CON fc VARIABILE E q=5,0)
MONOLITICO INCERNIERATO
MARGINE DI SICUREZZA CON NORMATIVA
0.00
0.20
0.40
0.60
0.80
1.00
1.20
0.00 1.00 2.00 3.00 4.00 5.00
Overstrength κ
Prob
abili
ty D
ensi
ty f
()
0.00
0.20
0.40
0.60
0.80
1.00
1.20
0.00 1.00 2.00 3.00 4.00 5.00
Overstrength κ
Prob
abili
ty D
ensi
ty f
()
24
CORRELAZIONE GETTO IN OPERA-PREFABBRICATO
MONOLITICO = INCERNIERATO
0.0
1.0
2.0
3.0
4.0
5.0
0.0 1.0 2.0 3.0 4.0 5.0
Overstrength κ - Type 1a
Ove
rstr
engt
h -
Type
1b
5
25
3° FASE: 1998-2004 (EN 1998)
AGGIORNAMENTO EUROCODICE 8
FARDIS: CONVEGNO ULISSE/CTE 2001
IMPEGNO PROVE SU STRUTTURE
PROVE ECOLEADER 2002/2003 ISPRA
EN EC8 2004 NORME PEREQUATE
26
PROVE ECOLEADER 2002/03
PROVA PSEUDODINAMICA PREFABBRICATO
27PROVA PSEUDODINAMICA GETTO IN OPERA
LABORATORI ELSA JRC - ISPRA
28
SUPPORTATI DA
− PROGETTO ULISSE (AITEC+ATECAP+ASSOBETON)
− ANDECE (SPAGNA)
− ANIPC (PORTOGALLO)
− POLITECNICO DI MILANO
− UNIVERSITA’ DI LUBIANA
29
αg = 0,36
-240
-180
-120
-60
0
60
120
180
240
0 5 10 15 20 25 30
Time [sec]
Drif
t [m
m]
-400
-300
-200
-100
0
100
200
300
400
-240 -180 -120 -60 0 60 120 180 240
Drift [mm]
Shea
r For
ce [k
N]
-240
-180
-120
-60
0
60
120
180
240
0 5 10 15 20 25 30
Time [sec]
Drif
t [m
m]
-400
-300
-200
-100
0
100
200
300
400
-240 -180 -120 -60 0 60 120 180 240
Drift [mm]
Shea
r For
ce [k
N]
αg = 0,72
30
CALIBRAZIONE MODELLO ANALITICO
6
31
RISULTATI
PORTATI A CEN/TC250/SC8 CHE HA APPROVATO IL NUOVO EUROCODICE 8
CON
PREFABBRICATO = GETTATO IN OPERA(REQUISITI SU CONNESSIONI)
CONFERMA MODELLO ANALITICO == VALIDITA’ ANALISI NUMERICHE
32
4° FASE: 2003-2006 (GROWTH PR.)
CONORMATIVE RESEARCH
PRECAST STRUCTURES EC8
SEISMIC BEHAVIOUR OFPRECAST CONCRETE STRUCTURES
WITH RESPECT TO EUROCODE 8
33
CONSORZIO
1. POLITECNICO DI MILANO (COORDINAMENTO)
2. MAGNETTI BUILDING – CARVICO
3. GECOFIN – VERONA
4. LAB. NATIONAL DE ENGNHARIA CIVIL – LISBONA
5. CIVIBRAL – SAO PEDRO FINS
6. NATIONAL TECHNICAL UNIVERSITY OF ATHENS
7. PROET – ATENE
8. UNIVERSITY OF LJUBLJANA
9. JOINT RESEARCH CENTRE – ISPRA
10. TONGJI UNIVERSITY - SHANGHAI
34
CAMPAGNA DI PROVE
− LNEC: TAVOLA VIBRANTE
− NTUA: TAVOLA VIBRANTE
− ELSA/JRC: PSEUDODINAMICHE
− TONGJI UNIV.: PSEUDODINAMICHE
35
PRECAST STRUCTURES EC8 2003/06
36
PRECAST STRUCTURES EC8 2003/06
7
37
LABORATORIO LNECPROVE SU TAVOLA VIBRANTE (1)
38
LABORATORIO NTUAPROVE SU TAVOLA VIBRANTE
39
LABORATORIO TONGJIPROVE CICLICHE SU NODI
40
RICERCA ESTESA A
− EFFETTO DIAFRAMMA
− CONTRIBUTO TAMPONAMENTI
− CONNESSIONI
41
…
CURVE VIBRATORIE SPERIMENTALI E NUMERICHE…
-200
-150
-100
-50
0
50
100
150
200
0 5 10 15 20 25 30 35
Force [kN]
ExperimentalNumerical
-200
-150
-100
-50
0
50
100
150
200
0 5 10 15 20 25 30 35
Force [kN]
ExperimentalNumerical
42
GRANDE MESSE DI RISULTATI
…
PROVE CICLICHE FINALI SUI DUE PROTOTIPI
-220
-165
-110
-55
0
55
110
165
220
-400 -300 -200 -100 0 100 200 300 400
Displacement [mm]
Forc
e [k
N]
-220
-165
-110
-55
0
55
110
165
220
-400 -300 -200 -100 0 100 200 300 400
Displacement [mm]
Forc
e [k
N]
8
43
RISULTATI
- PROBLEMI PROGETTUALI DELLE CONNESSIONI(ROTTURE LOCALI BORDI CALCESTRUZZO)
- GRANDE INFLUENZA DEI TAMPONAMENTI(PROVE PSEUDODINAMICHE A LIVELLO DI SLD)
- BUONA AZIONE DIAFRAMMA FINO A LIVELLI SUPERIORI(TEGOLI BINERVATI DISTANZIATI)
- CONFERMA DELLA GRANDE CAPACITA’ SISMICA(A LIVELLO DI 1 g ! )
44
5° FASE: 2005-2008
POGRAMMA RELUIS – DIP. PROTEZIONE CIVILE
VULNERABILITA’ SISMICA DEGLI EDIFICI ESISTENTI
RICERCA NAZIONALE AD AMPIO SPETTRO( 50 SEDI UNIVERSITARIE COINVOLTE)
45
LINEE DI RICERCA
1 – EDIFICI IN MURATURA2 – EDIFICI IN CALCESTRUZZO3 – PONTI ESISTENTI4 – PROGETTO AGLI SPOSTAMENTI5 – EDIFICI IN ACCIAIO E MISTI6 – OPERE DI SOSTEGNO7 – TECNICHE DI ISOLAMENTO8 – MATERIALI INNOVATIVI9 – MONITORAGGIO E ALLARME
10 – SVILUPPO DI DATABASE
46
LINEA 2 – EDIFICI IN CALCESTRUZZO
1 – METODI NON DISTRUTTIVI2 – FATTORI DI CONFIDENZA3 – EDIFICI NON REGOLARI4 – EDIFICI IBRIDI5 – INFLUENZA DEI TAMPONAMENTI6 – RUOLO DELLE SCALE7 – COMPORTAMENTO DEI NODI8 – AZIONI BIASSIALI9 – EDIFICI PREFABBRICATI
47
9 – EDIFICI PREFABBRICATI
POLITECNICO DI MILANO (COORD.) G. TONIOLO
UNIVERSITA’ DI BOLOGNA A. BENEDETTI
UNIVERSITA’ DEL MOLISE G. FABBROCINO
UNIVERSITA’ DI NAPOLI G. MAGLIULO
48
INDAGINI E CLASSIFICAZIONE DI TIPOLOGIE STRUTTURALI
RACCOLTA DI PROGETTI DI COSTRUZIONIESEGUITE IN ITALIA IN VARIE EPOCHE
COINVOLTA ASSOBETON
SCELTI 10 PREFABBRICATORICHE HANNO FORNITO
PIU’ DI 130 PROGETTI DI DIVERSE EPOCHE
9
49
AZIENDE COINVOLTE
AREA PREFABBRICATI (RE)ADRIANO RIVOLI (BA)BARACLIT (AR)GECOFIN PREFABBRICATI (VR)PRECOMPRESSI (MI)MANINI PREFABBRICATI (PG)PREFABBRICATI PRETECNO (VR)SICEP (CT)SPAV PREFABBRICATI (UD)TRUZZI PREFABBRICATI (MN)
50
ESEMPIO DI SCHEDA RILEVATA
51
CATALOGHI RELUIS/ASSOBETON
…
…
…
…
52
EDIFICI CRITICI
- DISCRIMINANTI (appoggi, diaframma, stabilità, P-Δ, taglio)
- ASSETTI STRUTTURALI
- ZONAZIONE SISMICA ALL’EPOCA
- EVOLUZIONE DELLA NORMATIVA
- STATO DI CONSERVAZIONE
53
Izmit – Turchia: disfatta prefabbricazione
54
EDIFICI SENZA DIAFRAMMA
…
…
10
55
DIAFRAMMA INCERTO
…
……
…
56
INCERTA STABILITA’ LATERALE
57
VERIFICA EDIFICIO ESISTENTE DEL 1980
…
…
58
ANALISI DINAMICA MODALE CON NUOVE NORME
…
…
59
SENZA DIAFRAMMA CON DIAFRAMMA
… …
60
VERIFICA PILASTRI CON COPERTURA FLESSIBILE (<1,00)(SENZA INTERVENTI IN COPERTURA)
…
q=1,5 senza fasciatura pilastri – q=2,5 con fasciatura pilastri
11
61
VERIFICA PILASTRI CON COPERTURA IRRIGIDITA (>1,00)CON CONTROVENTI IN COPERTURA
…
q=1,5 senza fasciatura pilastri – q=2,5 con fasciatura pilastri62
6a FASE: 2006-2011PROGRAMMA ASSOBETON (2006-2008)
COMPORTAMENTO SISMICO DELLE CONNESSIONI
POLITECNICO DI MILANO
UNIVERSITA’ DI NAPOLI
UNIVERSITA’ DI FIRENZE
UNIVERSITA’ DI PISA
UNIVERSITA’ DI BOLOGNA
UNIVERSITA’ DI BERGAMO
63
CLASSIFICAZIONE IN 7 ORDINI DI CONNESSIONI
1 RECIPROCHE TRA ELEMENTI DI SOLAIO
2 TRA ELEMENTI DI SOLAIO E TRAVI
3 TRA TRAVI E PILASTRI
4 TRA PILASTRI E FONDAZIONI
5 TRA PANNELLI DI PARETE E STRUTTURA
6 TRA SEGMENTI DI PILASTRO
7 RECIPROCHE TRA PANNELLI DI PARETE
64
NECESSITA’
QUALIFICARE OGNI TIPO DI CONNESSIONECON I PARAMETRI DEL COMPORTAMENTO SISMICO
CON PROVE SPERIMENTALI CODIFICATE
RESISTENZA – massima forza trasmessaDUTTILITA’ – deformazione ultima su snervamentoDISSIPAZIONE – energia specifica dei cicliDEFORMAZIONE – deformazione ultimaDEGRADO – calo resistenza nei cicliDANNO – deformazione residua allo scarico
65
LIVELLI DI PROVE
PROVE PARTICOLARI – su singoli connettori BPROVE LOCALI – su connessione A+B+CPROVE SU SOTTOINSIEMI – su gruppi di connessioniPROVE SU INSIEMI – su prototipi di strutture
66
Pre
limin
ary
Test
GIMED
PRIMA PROVE PRELIMINARICONNESSIONE TRA ELEMENTO SOLAIO E TRAVE
12
67
ROTTURA CALCESTRUZZO BORDO TRAVE
68
CON ANGOLARE APPENA DISTORTOTROPPO RESISTENTE!
69
NUOVO ANGOLARE PIU’ DEFORMABILEE MENO RESISTENTE PER SUCCESSIVE PROVE
70
DISTORSIONE PRECOCE ANGOLAREMAGGIORE DISPERSIONE DI ENERGIA
71
“VERE” PROVE SU CONCIO DI TEGOLO AL VERO
Scale 1:5
Scale 1:10
72
IMPIANTO DI PROVA (POLITECNICO DI MILANO)
…
…
13
73
PARTICOLARI CONNESSIONE TEGOLO-TRAVE
74
RISULTATO DI PROVA CICLICA
75
PROVE CONNESSIONI CONVOGLIATE IN PROGRAMMA EUROPEO2009-2011
SME POGRAMME – COMUNITA’ EUROPEA
“SAFECAST”
COMPORTAMENTO SISMICO DELLE CONNESSIONI
PROVE SU CONNESSIONI
REGOLE DI PROGETTAZIONE
INDICAZIONI NORMATIVE
76
CONSORZIO
1 – ASSOBETON ( I ) coord.2 – ANDECE ( E )3 – ANIPB ( P ) 10 – LNEC ( P )4 – SEVIPS ( GR ) 11 – ULJ ( SLO )5 – TPCA ( TR ) 12 – LABOR ( I )6 – EC DG JRC (Ispra) 13 – LUGEA ( I )7 – POLIMI ( I ) 14 – DLC ( I )8 – NTUA ( GR ) 15 – RIPHORSA ( E )9 – ITU ( TR ) 16 – HALFEN ( D )
77
IMPORTANZA DELLA RICERCA
…
L’AQUILA 6 APRILE 2009STRUTTURE BENE - CONNESSIONI PANNELLI MALE
78
PANNELLI CADUTI…
CONNESSIONI ROTTE
14
79
06.04.2009: TERREMOTO VIOLENTO
ACCELERAZIONI REGISTRATE 0.35g ÷ 0,40g
ZONA 1 PER STATO LIMITE ULTIMO (DANNI ATTESI)
PROGETTI CON VECCHIE NORME SENZA “CAPACITY DESIGN”
COMPORTAMENTO COSTRUZIONI PREFABBRICATEMOLTO POSITIVO
80
IMMAGINE SIMBOLO
…
CENTRO COMMERCIALE L’AQUILONENESSUN DANNO DI RILIEVO – SEMPRE OPERATIVO
81
DAI RILIEVI DOPO IL TERREMOTO
CENTINAIA DI EDIFICI PREFABBRICATI(Poggio Licenze, Monticchio, Ocre, Varranoni. Bazzano, Pile)
2 CROLLI DI ELEMENTI STRUTTURALI(1 TRAVE CON CAMPATE ADIACENTI, 1 COPPONE)
DIVERSI DISTACCHI DI PANNELLI DI TAMPONAMENTO(SIA VERTICALI CHE ORIZZONTALI)
DIVERSI DANNI LOCALI MINORI(SCHEGGIATURE SPIGOLI APPOGGI)
82
GRANDE MAGGIORANZA DI EDIFICI
…
OPERATIVI SENZA DANNI
83
ANCHE I PANNELLI DI TAMPONAMENTO
…
…84
ALCUNI DISTACCHI
…
PANNELLO ORIZZONTALE
15
85
…
PANNELLO VERTICALE
86
CONNESSIONI DELLA STRUTTURA
A SECCO CON CONNETTORI OK
(NON DUTTILI) SOVRADIMENSIONATECON “CAPACITY DESIGN”
SPERIMENTARE I MECCANISMI DI RESISTENZA
PROTEGGERE I BORDI
87
CONCLUSIONE
RUOLO TAMPONAMENTI / CONNESSIONINELLA RISPOSTA AL SISMA
CRITERI DI PROGETTODA APPLICARE SECONDO LE
NUOVE NORME TECNICHE DELLE COSTRUZIONI
88
…
GRAZIE PER L’ATTENZIONE