at a Glance · MWI LWI I Gamma X-Ray UV Infrared Microwaves Radiowaves SWI nm nm nm nm nm m m m mm...

1
M e a s u r e m e n t P r i n c i p l e S p e c i a l A p p l i c at i o n s C a m e ra S e l e c t i o n C r it e ri a S t a n d a r d A p p l i c a t i o n s Infrared camera Measured radiation Φ M Output of Radiation Φ‘ o Emitted by the measurement path Φ P Input of radiation Φ o Path τ P , θ P Reflected radiation Φ P Emitted radiation Φ ε Transmitted radiation Φ τ Object θ o , ε, ρ, τ Ambient θ u Background radiation Φ BG Object Background θ BG Infrared Thermography at a Glance MWIR LWIR FIR X-Ray Gamma UV Infrared Microwaves Radiowaves SWIR 1 nm 10 nm 1 μm 10 μm 100 μm 10 mm 100 mm 10 m 100 m 0.1 nm 0.01 nm 100 nm 1 mm 1 m 1 km 100 nm Wavelength 1 μm 10 μm 100 μm 1 mm Visible Thermal infrared Terahertz Electronics Automotive and yours? InfraTec GmbH Infrarotsensorik und Messtechnik Gostritzer Straße 61 – 63 01217 Dresden / GERMANY Phone +49 351 871-8630 Fax +49 351 871-8627 E-mail [email protected] Internet www.InfraTec.eu Spectrum of Electromagnetic Radiation Thermographic Measurement Situation Defect IR-radiation IR-camera Internal Excitation Electrical Induction Ultrasound Optical External Excitation Thermal Optical Triggering Pulse phase Lock-In Test object Camera control Image data processing Supply Emission ε + Reflection ρ + Transmission τ = 1 Planck's Radiation Law and Wien's Displacement Law Bulb, on glass Measurement on a resistor Bulb, through glass Cooled photon detector camera Uncooled microbolometer detector camera Open Grey filters Spectral filters Aperture Use of spectral filters in flexible filter wheels inside the thermographic camera Precise radiometric calibration For best-certified measurement accuracy from (-40 … 3,000) °C, ± 1 °C or ± 1 % Optics Microscopic lenses, wide-angle lenses, telephoto lenses, zoom lenses Interfacing Industrial standards like GigE / 10 GigE, fast and ultra-precise triggering, analogue / digital data input Software Convenient camera control, real-time data acquisition and analysis Thermal resolution Thermal resolution as low as 0.015 K Spatial resolution Detector formats with up to (1,920 × 1,536) IR pixels Time resolution Analysis of high-speed dynamic temperature changes and processes 25,000 Hz Spectral Thermography – Provides Material-specific Precision Measurements Active Thermography – Find Anomalies with Thermal Resolution in Millikelvin Range Tool construction Internal trigger interface Camera control and output of control signals for external devices Represented by: Design and specification subject to change without prior notice. © InfraTec 2019 (All the stated product names and trademarks remain in property of their respective owners.) Picture credits: © iStock.com / voraorn, LianeM Aerospace Airborne Watch some videos illustrating what thermography is used for: Stress analytics Natural sciences With friendly support of: Passive thermography Visual image Lock-in Thermography

Transcript of at a Glance · MWI LWI I Gamma X-Ray UV Infrared Microwaves Radiowaves SWI nm nm nm nm nm m m m mm...

Page 1: at a Glance · MWI LWI I Gamma X-Ray UV Infrared Microwaves Radiowaves SWI nm nm nm nm nm m m m mm mm mm m m m m Wavelength nm m m m mm Vle Thermal nfrared Terahert Electronics Automotive

Mea

sure

ment P

rinciple Special Applications

Camera Selection Criteria Standard Applic

atio

ns

Infraredcamera

Measured radiation ΦM

Output of Radiation Φ‘o

Emitted by themeasurement path ΦP

Input of radiation Φo

PathτP, θP

Re�ected radiation ΦP

Emitted radiation Φε

Transmitted radiation Φτ

Objectθo, ε, ρ, τ

Ambient θu

Background radiation ΦBG

Object Background θBG

Infrared Thermographyat a Glance

MWIR LWIR FIR

X-RayGamma UV Infrared Microwaves Radiowaves

SWIR

1 nm 10 nm 1 μm 10 μm 100 μm 10 mm 100 mm 10 m 100 m0.1 nm0.01 nm 100 nm 1 mm 1 m 1 km

100 nmWavelength 1 μm 10 μm 100 μm 1 mm

Visible Thermalinfrared

Terahertz

Electronics

Automotive

… and yours?

InfraTec GmbHInfrarotsensorik und MesstechnikGostritzer Straße 61 – 6301217 Dresden / GERMANY

Phone +49 351 871-8630Fax +49 351 871-8627E-mail [email protected] www.InfraTec.eu

Spectrum of Electromagnetic Radiation

Thermographic Measurement Situation DefectIR-radiation IR-camera

Internal Excitation

Electrical

Induction

Ultrasound

Optical

External ExcitationThermal Optical

Triggering

Pulse phaseLock-In

Test object

Camera controlImage data processingSupply

Emission ε + Reflection ρ + Transmission τ = 1

Planck's Radiation Law and Wien's Displacement Law

Bulb, on glass

Measurement on a resistor

Bulb, through glass

Cooled photon detector camera

Uncooled microbolometer detector camera

Open

Grey filters

Spectral filters

Aperture

Use of spectral filters in flexible filter wheels inside the thermographic camera

Precise radiometric calibrationFor best-certified measurement accuracy from (-40 … 3,000) °C, ± 1 °C or ± 1 %

OpticsMicroscopic lenses, wide-angle lenses, telephoto lenses, zoom lenses

InterfacingIndustrial standards like GigE / 10 GigE, fast and ultra-precise triggering, analogue / digital data input

SoftwareConvenient camera control, real-time data acquisition and analysis

Thermal resolutionThermal resolution as low as 0.015 K

Spatial resolutionDetector formats with up to (1,920 × 1,536) IR pixels

Time resolutionAnalysis of high-speed dynamic temperature changes and processes

25,000Hz

Spectral Thermography – Provides Material-specific Precision Measurements

Active Thermography – Find Anomalies with Thermal Resolution in Millikelvin Range

Tool constructionInternal trigger interfaceCamera control and output of control signals for external devices

Represented by:

Des

ign

and

spec

ifica

tion

subj

ect t

o ch

ange

with

out p

rior n

otic

e. ©

Infr

aTec

201

9 (A

ll th

e st

ated

pro

duct

nam

es a

nd tr

adem

arks

rem

ain

in p

rope

rty

of th

eir r

espe

ctiv

e ow

ners

.) Pi

ctur

e cr

edits

: © iS

tock

.com

/ vo

raor

n, L

iane

M

Aerospace

Airborne

Watch some videosillustrating what

thermography is used for:

Stress analytics

Natural sciences

With friendly support of:

Passive thermographyVisual image Lock-in Thermography