5V/200mA Isolated DC/DC converter -...

2
1/1 5V/200mA Output Isolated DC/DC converter BP5512A Data Sheet 2012.06 - Rev. A www.rohm.com © 2012 ROHM Co., Ltd. All rights reserved. Unit Conditions (Ta=25°C) V V mA V V mVp-p % Io=50 to 200mA DC Parameter Symbol Typ. Max. Min. Vi Vo Io Vr Vl Vp η 5.0 5.0 0.05 0.05 50 62 6.5 5.5 200 0.1 0.2 200 4.5 4.5 0 57 External Components Settings Use a fuse for safety. 220μF / 25V Low impedance type for power supply F1: Fuse C2: Output capacitor 220μF / 25V Low impedance type for power supply C2: Output capacitor Pin No. 1 2 3 4 5 6 7 Function Input terminal GND terminal Non pin Non pin Output common terminal Non pin Output terminal Pin Name Vi GND Non pin Non pin COM Non pin Vo Input voltage Operating temperature range Storage temperature range Allowable maximum surface temperature Maximum output current Withstand voltage Parameter Conditions Symbol Vi Topr Tstg Tcmax Iomax VI Limits 8 20 to +85 40 to +85 105 200 AC2300 Unit V °C °C °C mA V Ambient temperature + the module self-heatingTcmax Between input and output, 1 minute DC Vi=4.5 to 6.5V (Unless otherwise noted, Vi=5.0V, Io=200mA, Ta=25°C) C1 Vo (5V/200mA) + Vi C2 GND + COM BP5512A 1 2 5 7 0.75±0.1 1.3±0.2 P=2.54±0.2 2.54X6=15.24TYP. 1 2 5 7 9.13MAX. 21.4MAX 3.5 +0.5 1.0 0.5±0.05 11.05MAX. 6.15MAX. MARKING SIDE 28.2MAX 17.2MAX 0 50 100 150 200 250 300 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 Ambient temperature Ta(°C) (Vi=5V) Output current Io(mA) OPERATION RANGE 0 10 20 30 40 50 60 70 80 0 50 100 150 200 Conversion Efficiency η(%) Output Current Io(mA) (Vi=5.0V, Ta=25°C) Refer to derating curve 1 1 The load should be reduced according to the surrounding temperature, input voltage. Absolute Maximum Ratings Electrical Characteristics Input voltage Output voltage Output current Line regulation Load regulation Output ripple voltage Power conversion efficiency Test Circuit Use a fuse for safety. Dimensions (Unit : mm) Derating Curve Conversion Efficiency

Transcript of 5V/200mA Isolated DC/DC converter -...

Page 1: 5V/200mA Isolated DC/DC converter - Rohmrohmfs.rohm.com/en/products/databook/datasheet/module/...Please be sure to implement in your equipment using the Products safety measures to

1/1

5V/200mA Output

Isolated DC/DC converterBP5512A

Data Sheet

2012.06 - Rev. Awww.rohm.com© 2012 ROHM Co., Ltd. All rights reserved.

Unit Conditions

(Ta=25°C)

VV

mAVV

mVp-p%

Io=50 to 200mA

DC

Parameter Symbol Typ. Max.Min.ViVoIoVrVlVpη

5.05.0−

0.050.055062

6.55.52000.10.2200−

4.54.50−−−

57

External Components Settings

Use a fuse for safety.

220μF / 25V Low impedance type for power supply

F1: Fuse

C2: Output capacitor

220μF / 25V Low impedance type for power supplyC2: Output capacitor

Pin No.1234567

FunctionInput terminalGND terminalNon pinNon pinOutput common terminalNon pinOutput terminal

Pin NameVi

GNDNon pinNon pin

COMNon pin

Vo

Input voltageOperating temperature rangeStorage temperature range

Allowable maximumsurface temperature

Maximum output currentWithstand voltage

Parameter ConditionsSymbolVi

ToprTstg

Tcmax

IomaxVI

Limits8

−20 to +85−40 to +85

105

200AC2300

UnitV°C°C

°C

mAV

Ambient temperature +the module self-heating≤Tcmax

Between input and output, 1 minute

DC

Vi=4.5 to 6.5V

(Unless otherwise noted, Vi=5.0V, Io=200mA, Ta=25°C)

C1

BP5512

Vo(5V/200mA)

+

Vi

C2

GND

+

COM

1 2 5 7

BP5512A

1 2 5 7

0.75±0.11.3±0.2

P=2.54±0.2

2.54X6=15.24TYP.

1 2 5 7

9.13MAX.

21.4

MA

X3.

5+0

.5−1

.0

0.5±0.05

11.05MAX. 6.15MAX.

MA

RK

ING

SID

E

28.2MAX 17.2MAX

0

50

100

150

200

250

300

-30 -20 -10 0 10 20 30 40 50 60 70 80 90 100

Ambient temperature Ta(°C)

(Vi=5V)

Out

put c

urre

nt Io

(mA

)

OPERATION RANGE

0

10

20

30

40

50

60

70

80

0 50 100 150 200

Con

vers

ion

Effi

cien

cy η

(%)

Output Current Io(mA)

(Vi=5.0V, Ta=25°C)

Refer to derating curve

∗1

∗1 The load should be reduced according to the surrounding temperature, input voltage.

Absolute Maximum Ratings

Electrical Characteristics

Input voltageOutput voltageOutput currentLine regulationLoad regulationOutput ripple voltagePower conversion efficiency

Test Circuit

Use a fuse for safety.

Dimensions (Unit : mm)

Derating Curve

Conversion Efficiency

Page 2: 5V/200mA Isolated DC/DC converter - Rohmrohmfs.rohm.com/en/products/databook/datasheet/module/...Please be sure to implement in your equipment using the Products safety measures to

R1120Awww.rohm.com© 2012 ROHM Co., Ltd. All rights reserved.

Notice

ROHM Customer Support System http://www.rohm.com/contact/

Thank you for your accessing to ROHM product informations. More detail product informations and catalogs are available, please contact us.

N o t e s

No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into account when designing circuits for mass production. Great care was taken in ensuring the accuracy of the information specified in this document. However, should you incur any damage arising from any inaccuracy or misprint of such information, ROHM shall bear no responsibility for such damage. The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM and other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the use of such technical information. The Products specified in this document are intended to be used with general-use electronic equipment or devices (such as audio visual equipment, office-automation equipment, commu-nication devices, electronic appliances and amusement devices). The Products specified in this document are not designed to be radiation tolerant. While ROHM always makes efforts to enhance the quality and reliability of its Products, a Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to human life or create a risk of human injury (such as a medical instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuel-controller or other safety device). ROHM shall bear no responsibility in any way for use of any of the Products for the above special purposes. If a Product is intended to be used for any such special purpose, please contact a ROHM sales representative before purchasing. If you intend to export or ship overseas any Product or technology specified herein that may be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to obtain a license or permit under the Law.