22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS...

38
22 Years of Excellence! 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February, 2010

Transcript of 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS...

Page 1: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Introducing the Model 602 BetaPLUS Dual-Channel

Particulate Monitor

San Diego, California4 February, 2010

Page 2: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

What is the Model 602? • The Model 602 is a dual-channel, 14C Beta Gauge with

less than 100 μCi. • It uses cartridge filters as opposed to a filter tape.• The sample time is nominally 1 hour. But, it can be

modified for other averages (up to 72 hours).• The autonomy period is 15 days (worst case) and 48

days (nominal)• The system operates at ambient temperature and

humidity.• Virtually any operating parameter is available from

RS232 or using the optional internal modem. • Internal modem can dial telephone numbers if any

warning occurs.

Page 3: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

What is the Model 602?

• Really, the Model 602, in it’s typical configuration, is two instruments in one:

– A PM10 Beta Guage– A PM2.5 Beta Guage

Page 4: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

What is the Model 602?

• In the 24-48-72-hour mode, it is four instruments in one:

– A PM10 Beta Guage– A PM2.5 Beta Guage– A PM10 Sampler– A PM2.5 Sampler

Page 5: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

What is the Model 602?

• The analyzer has three pumps.– Two sample pumps– Compressor to operate the filter changer

Sample Pump Compressor

Page 6: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Certifications

• The instrument has “EuroNorm” certification under…– EN12341-1999 (PM10)– EN14907-2005 (PM2.5)– TAPI is conducting US EPA certification tests

(Summer 2010).

Page 7: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Philosophy

• The Model 602 is designed to isolate and counteract the known causes of uncertainty in a β attenuation measurement.

– Flow uncertainty– Detector performance– Humidity– Sample density– Semi-volatile deposition “boil-off”– Background radiation

Page 8: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Why is the Model 602 called a BetaPLUS ?

Because it is the best, most accurate dust monitor ever built.

Period.

Page 9: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Why is the Model 602 called a BetaPLUS ?

• Complete air density analysis.– Benefit: Eliminates the uncertainty related to the quantification

of “cubic meters” and flow errors.

• Complete detector performance analysis.– Benefit: Uncertainties in detector performance, leading to false

concentrations, are eliminated.

• “Spy” filter.– Benefit: Completely eliminated biases due to moisture in the

sample. Provides a zero reference.

• Simultaneous PM2.5 and PM10 measurements.– Benefit: “Two-for-one”

Page 10: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Complete flow and air density analysis

• The analyzer continuously controls and corrects for actual volumetric flow. It compares the measured flow (transfer standard) to the calculated flow and gives an accuracy figure continuously.– Benefit: The flow through the

filter does not change. • The analyzer uses the inlet

pressure and inlet temperature to correct for the flow through the inlet.– Benefit: PM10 and PM2.5

heads do not “over sample” or “under-sample”

Page 11: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Complete flow and air density analysis

• A direct flow measurement is also made using a ΔP across a flow meter. This is applied to a correction factor continuously. The flow is controlled to +1% of the set point.– Benefit: Active flow controller,

unlike “passive” critical orifices, which are dependent on atmospheric pressure.

Page 12: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Complete flow and air density analysis

• The unit performs an automatic leak check. – Benefit: Insures the filter seal is

intact.

• The analyzer compares the filter pressure drop, the pump pressure and the atmospheric pressure, so that Pa>Pf>Pp.

– Benefit: Insures that the pressure sensors themselves are working properly.

Page 13: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Complete flow and air density analysis

• The unit performs an automatic “Span Test” which compares a transfer flow standard with the instrument’s measured flow. – Benefit: Insures the calculated

flow rate is correct.

Page 14: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Quick Review

• The basic Beta Attenuation Equation (Lenard’s Law):

m =Фi

Фf

Vμ ln ( )

Where, m is the mass

V is the volume of air

μ is the beta coefficient

Φi is the “blank” count

Φf is the “collected” count

Page 15: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Complete detector performance analysis

• The instrument does the equivalent of an “auto-zero” before every measurement cycle. This is accomplished by doing a count with no filter present.

Φi (corr) = Фi - Фdark

Page 16: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Complete detector performance analysis

• After each sampling cycle, the analyzer corrects for ambient radiation (such as Radon) by inserting an aluminum shield between the 14C source and the filter.

Φf (corr) = Фf - Фnat

Page 17: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Complete detector performance analysis

• Detector stability is continuously measured. Should the detector count rate deviate from the theoretical decay rate, an alarm is given.

• Long-term detector stability is analyzed by comparing “air counts” (without flow) of sequential measurement cycles. If drift is excessive, an alarm is given.

• The detector HVPS is monitored for ripple and/or drift. If the HVPS deviates by more than 2%, the analyzer gives an alarm message.

• A dynamic span check is accomplished at the beginning of each cycle, using a thin sheet of aluminum to simulate a dust load.

Page 18: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

“Spy” filter

• A small filter, with no flow through it (hence, no dust load), at ambient conditions, is analyzed before and after a measurement cycle.

• Benefit: Any water condensation that could affect the dust analysis is measured and subsequently subtracted off of the resulting mass concentration.

Page 19: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Model 602 Operation

• The Model 602 uses a carousel of filters.• There is also a movable arm which has the detector and β source.

Page 20: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Model 602 Operation

Carousel

The Carousel rotates to position the filters.

Page 21: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Model 602 Operation

Sample Tubes

Sample tubes bring the unheated sample from the

outdoors.

Page 22: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Model 602 Operation

Filters

47 mm Filters can be glass fiber, quartz, or

PTFE (24 hr. mode) or glass fiber (1 hour mode)

Page 23: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Model 602 Operation

Source/Detector Assembly

The source/detector assembly is on a swinging arm.

Page 24: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Model 602 Operation

Spy Filters

There are three spy filters on the carousel.

Page 25: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Model 602 Operation

• Filters are added/removed from the carousel by means of a “loader” and “unloader” respectively.

Page 26: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Model 602 Operation

• Filters are easily mounted in their cartridges.

Page 27: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Model 602 Operation

• Filters are easily mounted in their cartridges.

Page 28: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Model 602 Specifications

Item Hourly Mode Multi-Mode

Sampling Period 1 Hour 8-12-24-48-72 HoursFilter Cartridges 47 mm dia. 47 mm dia.Spot Size 1 to 1.8 cm² 2.54, 5.2, 7.07, 11.95 cm²Filter Media Quartz, Glass Quartz, Glass, PTFEFilter Capacity 96 CartridgesRange Up to 10 mg/m3

Flow Rate 16.7 LPM Flow Accuracy + 1%Flow Stability + 0.5% (Typical)Flow Control Servo-Controlled ValveWeight 64 kg. (141 lbs.)Power Consumption 1200 W

Page 29: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Performance

Page 30: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Performance

Page 31: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Performance

Model 602

Model 602

Model 602

Model 602

Page 32: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Performance

Page 33: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Performance

M602

Page 34: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

PerformanceHourly Averages (PM2.5)

-20

0

20

40

60

80

100

120

140

160

da

te &

tim

e

20

/11

/09

12

:00

21

/11

/09

01

:00

21

/11

/09

14

:00

22

/11

/09

03

:00

22

/11

/09

16

:00

23

/11

/09

05

:00

23

/11

/09

18

:00

24

/11

/09

07

:00

24

/11

/09

20

:00

25

/11

/09

09

:00

25

/11

/09

22

:00

26

/11

/09

11

:00

27

/11

/09

00

:00

27

/11

/09

13

:00

28

/11

/09

02

:00

28

/11

/09

15

:00

29

/11

/09

04

:00

29

/11

/09

17

:00

11

/30

/20

09

6:0

0

11

/30

/20

09

19

:00

12

/1/2

00

9 8

:00

12

/1/2

00

9 2

1:0

0

12

/2/2

00

9 1

0:0

0

12

/2/2

00

9 2

3:0

0

12

/3/2

00

9 1

2:0

0

12

/4/2

00

9 1

:00

12

/4/2

00

9 1

4:0

0

12

/5/2

00

9 3

:00

12

/5/2

00

9 1

6:0

0

12

/6/2

00

9 5

:00

12

/6/2

00

9 1

8:0

0

12

/7/2

00

9 7

:00

12

/7/2

00

9 2

0:0

0

12

/8/2

00

9 9

:00

12

/8/2

00

9 2

2:0

0

12

/9/2

00

9 1

1:0

0

12

/10

/20

09

0:0

0

ug

/m^

3 SN111A

SN111B

SN115A

Page 35: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Performance24 Hour Averages Vs. Reference

0

10

20

30

40

50

60

70

11/2

0/20

09

11/2

1/20

09

11/2

2/20

09

11/2

3/20

09

11/2

4/20

09

11/2

5/20

09

11/2

6/20

09

11/2

7/20

09

11/2

8/20

09

11/2

9/20

09

11/3

0/20

09

12/1

/200

9

12/2

/200

9

12/3

/200

9

12/4

/200

9

12/5

/200

9

12/6

/200

9

12/7

/200

9

12/8

/200

9

12/9

/200

9

ug

/m^

3

Reference

SN111A

SN111B

SN115A

Av. SN111A&B

Page 36: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Price

$55,000 …ready to sample

Page 37: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Target Market• We will continue to try to get the price down and

(of course) get US EPA certification. Until then, we are targeting– Universities– Reference Laboratories– Research Laboratories– Other Critical-Measurement Users– Situations where we can manage the specifications

– Situations where there is a spec for PM10 and PM2.5

Page 38: 22 Years of Excellence! © 2010 Teledyne Technologies Introducing the Model 602 Beta PLUS Dual-Channel Particulate Monitor San Diego, California 4 February,

22 Years of 22 Years of Excellence!Excellence!

© 2010 Teledyne Technologies

Availability

Now*

*meaning……..