Version 1.0 | 05.08.2009Page 1 of 3

Coaxials basing upon DIN 47264, EN 50117-1 and IEC 61196-1

ApplicationThe radio-frequency cables described in this chapter are used in transmitter and receiver installations in radiocommunications as well as in the entire field of commercial radio-frequency technology and electronics.

StandardsDIN 47264, EN50117-1, IEC 61196-1

Flame resistanceacc.to. IEC 60332-3-24

ConstructionInner conductor copper wire, bare, diameter 2.61 ± 0.02 mm

Insulation Foam-PE, diameter 7.3 ± 0.05

outsideConductor Al-PET-Al-foil + copper braid, tinned, 96% optical coverage + Al-PET-Al-foil

Sheath FRNC, flame retardant, non corrosive copolymer, diameter 10.3 ± 0.2

Farbe black, RAL 9005

Mechanical propertiesMinimum bending radius without load 5 x outer diameter

with load 10 x outer diameter

Temperature during operation -30° C to + 70° C

during installation -15° C to + 55° C

Corrosivity IEC 60754-2

Page 2: 02Y(St)C(St)H 2.6/7 - Prysmian Groupstaticres.prysmiangroup.com/ds/en/business_markets/... ·  · 2014-09-0402Y(St)C(St)H 2.6/7.3AF LINKING THE FUTURE hf36e ... Minimum bending radius

02Y(St)C(St)H 2.6/7.3AF

LINKING THE FUTURE www.prysmiangroup.comhf36e

Version 1.0 | 05.08.2009Page 2 of 3

Electrical properties at 20°C

DC resistance Inner conductor 3.2 Ω/l,

Outer conductor 3.9 Ω/km

Mutual capacitance 80 pF/m

Velocity ratio 80 %

Characteristic impedance 200 MHz 50 Ω ± 2 Ω

Transfer impedance 10 MHz ≤ 4 mΩ/m

100 MHz ≤ 2 mΩ/m

Operating voltage 1.2 kVrms

Test voltage Inner/Outer conductor 3.0 kVrms

Screening factor 100-1000 MHz 100 dB

Insulation resistance ≥ 10 GΩ*km

Electrical data at 20°C

Frequency(MHz)

Attenuation(dB/100m)

Max. power rating(Watts)(ambient temperature 40°Cand max. inner conductortemperature 100°C)

Return loss(dB)several peaks are allowed

nominal maximum

1 0.4 17325 Frequency

(MHz)

10 1.3 5480 50-450 26

100 4.2 1705 450-1000 23

200 6.0 1205

800 12.3 580

1000 13.7 520

1600 17.8 311

2000 19.9 348

3000 24.9 258

Technical dataProduct

code

Designation Type Brand

name

Outer

diamete

r

Weight Standar

d

delivery

length

Drum

size

Gross

weight

Coppe

r

conte

nt

Tensil

e

force

mm kg/km m *PWD kg N

100279802Y(St)C(St

)H

2.6/7.3

AF-FRNC

2.6/7.3AF

Low loss10.3 166.2 1000

760/360/4

20180 108.6 540

*PWD (Plywood drum)

[PRODUCT CODE TABLE]

Page 3: 02Y(St)C(St)H 2.6/7 - Prysmian Groupstaticres.prysmiangroup.com/ds/en/business_markets/... ·  · 2014-09-0402Y(St)C(St)H 2.6/7.3AF LINKING THE FUTURE hf36e ... Minimum bending radius

02Y(St)C(St)H 2.6/7.3AF

LINKING THE FUTURE www.prysmiangroup.comhf36e

Version 1.0 | 05.08.2009Page 3 of 3

© PRYSMIAN GROUP 2009, All Rights ReservedAll sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian Group: anymodification or alteration afterwards of product may give different result.The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, withoutthe written consent of Prysmian Group. The information is believed to be correct at the time of issue. Prysmian Group reserves the right toamend this specification without prior notice. This specification is not contractually valid unless specifically authorised by Prysmian Group.