ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic...

29
ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ ΑΥΤΟΜΑΤΩΝ ΠΟΡΤΩΝ ΟΡΟΦΟΥ ASSEMBLING & REGULATION INSTRUCTIONS FOR AUTOMATIC LANDING DOORS

Transcript of ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic...

Page 1: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣΑΥΤΟΜΑΤΩΝ ΠΟΡΤΩΝ ΟΡΟΦΟΥ

ASSEMBLING & REGULATION INSTRUCTIONSFOR AUTOMATIC LANDING DOORS

Page 2: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

LANDING DOORS

Page 3: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre
Page 4: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

PARTS DESCRIPTION 22 FRAMES ASSEMBLING 23 ASSEMBLING OF CENTRE PARTING MODERNIZATION LANDING DOORS WITHOUT FRAMES 24 ASSEMBLING TOOL OF LANDING DOORS WITHOUT FRAMES (centre opening) 25 ASSEMBLING OF SIDE PARTING MODERNIZATION LANDING DOORS WITHOUT FRAMES 26 ASSEMBLING TOOL OF LANDING DOORS WITHOUT FRAMES (side opening) 27 ASSEMBLING OF MECHANISM AND TREAD 28 FIXING FRAMES TO WALL 29 HANGERS AND GUIDE SHOES INSTALLATION 30 DOOR RELEASE LOCK ASSEMBLING 30 ADJUSTMENT OF PANELS 31 ADJUSTMENT OF WHEELS 32 LOCKING DEVICE 32/33/34 HOMOLOGATIONS 35 HINWEISE ZUR INSTALLATION 36/37/38/39

PREVENTIVE MAINTENANCE FOR LANDING DOORS 40

INDEX

Page 5: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

2222

PARTS DESCRIPTION

Central Cabin Door

Telescopic Cabin Door

1 Header2 Mechanism3 Plate4 Frames5 Panels6 Tread & tread support7 Fixing bracket

Page 6: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

23

FRAMES ASSEMBLING

When the frame is assembled, before completely tightening, check that the diagonal measurements (A and B) are equal.

Page 7: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

24

ASSEMBLING OF CENTRE PARTING MODERNIZATION LANDING DOORS WITHOUT FRAMES

Page 8: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

25

ASSEMBLING TOOL OF LANDING DOORS WITHOUT FRAMES

Page 9: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

26

ASSEMBLING OF SIDE PARTING MODERNIZATION LANDING DOORS WITHOUT FRAMES

Page 10: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

27

ASSEMBLING OF SIDE PARTING MODERNIZATION LANDING DOORS WITHOUT FRAMES

ASSEMBLING TOOL OF LANDING DOORS WITHOUT FRAMES

Page 11: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

28

ASSEMBLING OF MECHANISM AND TREAD

Page 12: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

29

ASSEMBLING OF MECHANISM AND TREAD FIXING FRAMES TO WALL

Page 13: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

30

HANGERS & GUIDE SHOES INSTALLATION

DOOR RELEASE LOOK ASSEMBLING

Assembling procedure of the door release lock for telescopic left and central opening 2 panels (figure 1), and telescopic right opening 2 panels and central opening 4, 6, 8 panels (figure 2).

Installation procedure of the upper hangers (figure 1) and lower guide shoes (figure 2) in the panel.

Page 14: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

31

HANGERS & GUIDE SHOES INSTALLATION

DOOR RELEASE LOOK ASSEMBLING

ADJUSTMENT OF PANELS

1. Place the panels centered to their plates leaving a gap of 15mm between the extreme of the panel and the plate. Tighten the nuts that join the plates with the suspensions (fig. 1).2. Slide the panels until they are raised with the frame and fix the air cord clamp (fig. 2).3. Slightly straighten the panels by the upper and lower suspension nuts until the panel is completely parallel to the post (fig. 2).4. Check that between tread, between panel and panel and between panel and frame exists a distance of 5mm. (fig. 3).

Once the panels are adjusted, there must be an overlap of 5 mm between a panel and the fire protectim angle of the other panel, as shown in the following drawing.

Page 15: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

32

ADJUSTMENT OF WHEELS

LOCKING DEVICE

Lock beak with electrical contact adjustment:

1. Using the two screws at A, adjust the lock beak until the centre of the pivot pin is 100mm from the leading edge of the hanger. When the hanged plate touches the rubber stop 1, adjust the contact support plate until there is 1mm between the lock beak and the contact support plate when the lock is fully engaged. (fig. 1, 2 and 3, page 32) 2. Fit the rubber stop A2 in the beak support and adjust so that the beak remains in the horizontal position (fig. 4, page 32)

3. Then adjust rubber stop B2 leaving sufficient clearance for the beak to unlock when the door is opening (fig. 4, page 32)

Roller mounting with skate adjustment:1. Place the centre line of the lock roller wheels to 145mm from the plate extreme by screws B as shown (fig. 6, page 33)2. Check that cabin skate is centered between the rollers of the lock beak (fig. 5 and 7, pages 32-33)

1. The adjustment will be made by the inferior (eccentric) wheels, by rotating the shaft you can adjust the gap that should be between the guide and wheel.2. Adjustment may be done with an allen and flat wrench. An excessive tightening could stop the door.3. The correct adjustment is when wheel touches the guide without braking on it.

Wheels are adjusted in factory, only should be regulated in case of bad functioning.

Page 16: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

33

ADJUSTMENT OF WHEELS

LOCKING DEVICE

LANDING DOOR LOCKER

Page 17: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

34

LANDING DOOR LOCKER

MAINTENANCE1. Check that the landing doors are fully closed and can only be opened using the emergency key2. Check to ensure that the spring closer fully closes the doors3. Check the information on the identity label (corresponds to the certificate organism for security components and CE label for security components), which must be visible from the back site of the door4. Check that the electrical contact operates and is correctly installed5. Check that the male contact at the electric bridge enters to electrical contact correctly.

Doors 4 panels between CO 600 until CO 915 the measure is 80mm.

If any fault is detected in the lock or electrical contacts, the defective components or complete unit must be replaced.

Page 18: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

35

LANDING DOOR LOCKER LANDING DOORS HOMOLOGATIONS

FIRE HOMOLOGATIONS

• LNE of ParisAll type of 210/10/40 automatic landing doors model 0071/0199/02

• TÜV Sud Industrie Service GmbHPRC2 2 Panel centre parting landing door, 40/10 model D-97......ATV699PRC2 2 Panel centre parting landing door, 50/11 mode D-97......ATV702PRC4 4 Panel centre parting landing door, 40/10 model D-97......ATV701PRC4 4 Panel centre parting landing door, 50/11 model D-97......ATV704PRC6 6 Panel centre parting landing door, 50/10 model D-97......ATV705PRT2 2 Panel side opening landing door, 40/10 model D-97......ATV700PRT2 2 Panel side opening landing door, 50/11 model D-97......ATV703

BELGIUM• PRC2 2 Panel centre parting landing door: PF 120min. 2001-L-16• PRC4 4 Panel centre parting landing door: PF 120min. 2001-L-16• PRC6 6 Panel centre parting landing door: PF 120min. 2001-L-16• PRT2 2 Panel side opening landing door: PF 90min. 2001-L-15• Hinged semi-automatic «Global» door with vision panel: PF 30min. 4/EF/57.299/GF/695A

SPAIN•PRC2 2 Panel centre parting landing door: PF 60min. 96.010.714•PRC2 2 Panel centre parting landing door: RF 60min. 97.002.388•PRC2 2 Panel centre parting landing door «Big Vision»: PF 60min. 4001076•PRC4 4 Panel centre parting landing door: PF 120min. 96.000.459•PRC6 6 Panel centre parting landing door: PF 120min. 21.000.655•PRC8 8 Panel centre parting landing door: PF 120min. 152048•PRT1 1 Panel side opening landing door: PF 120min. 95.007.708•PRT2 2 Panel side opening landing door: PF 120min. 96.010.713•PRT2 2 Panel side opening landing door: RF 60min. 22.032.049•PRT2 2 Panel side opening landing door «Big Vision»: RF 30min. 21.015.512•PRT3 3 Panel side opening landing door: PF 120min. 96.009.477•PRT4 4 Panel side opening landing door: PF 120min. 21.021.975•Hinged semi-automatic «Global» door with vision panel: PF 30min. 20.016.336•Hinged semi-automatic«Global» door without vision panel: PF 60min. 20.016.336•Hinged semi-automatic «Fermator» door with vision panel: PF 120min. 4023118•Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118

FRANCE•PRC2 2 Panel centre parting landing door: PF 120min. 95-V-135•PRC4 4 Panel centre parting landing door: PF 90min. 04-G-050•PRC6 6 Panel centre parting landing door: PF 60min. 95-G-213

•PRT2 2 Panel side opening landing door: RF 90min. 01-V-138•PRT3 3 Panel side opening landing door: RF 30min. 01-A-267•Hinged semi-automatic «Fermator» door with vision panel: PF 30min. 93.36117•Hinged semi-automatic «Fermator» door without vision panel: PF 30min. 93.36117

UNITED KINGDOM•PRC2 2 Panel centre parting landing door: PF 120min. 11.751•PRC2 2 Panel centre parting landing door «Stainless Steel»: PF 180min. 113248•PRC2 2 Panel centre parting landing door: RF 60min. 137699•PRC2 2 Panel centre parting landing door «Big Vision»: PF 60min. 142007•PRC4 4 Panel centre parting landing door: PF 120min. 133233•PRC6 6 Panel centre parting landing door: PF 120min. 136481•PRT1 1 Panel side opening landing door: PF 120min. 136471•PRT2 2 Panel side opening landing door: PF 120min. 117003•PRT2 2 Panel side opening landing door: RF 60min. 137082•PRT3 3 Panel side opening landing door: PF 120min. 11752

ITALY•PRT2 2 Panel centre parting landing door: REI 120min. CSI 1092 RF

SINGAPUR•PRC2 2 Panel centre parting landing door: PF 60min. G41947/CLT•PRT2 2 Panel side opening landing door: PF 60min. G45721/KKC

U.S.A.•PRC6 6 Panel centre parting landing door: PF 90min. 651-0486.01•Hinged semi-automatic «Fermator» door without vision panel: PF 90min. 651-0486.02

HONG KONG•PRC2 2 Panel centre parting landing door «Stainless Steel»: PF 180min. 108.107

Page 19: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

36

HINWEISE ZUR INSTALLATION

*)Die Maße b1 und h1 sind identisch mit den lichten Durchgangs-maßen, weil die Zargenseitenteile und die Zargenoberteile nicht breiter bzw höher als 150 mm sein können. Bilder 1, 2, 3.

ÜberdeckungTürblätter müssen,mit Ausnahme an der Schließkante und an der Schwelle, die Türzarge überdecken. Wenn Türblätter übereinandergreifen, muß eine Überdeckung wie an der Türzarge vorhanden sein:Die Überdeckung muß betragen:a. bei horizontal bewegten Schacht- Schiebetüren seitlich und oben mindestens 15mm (Beispiele siehe Bilder 4 bis 7)b. bei horizontal bewegten Schacht- Schiebetüren alsTeleskoptüren an den Stellen, an denen Türblätter überein- andergreifen, mindestens 15mm (Beispiele siehe Bild 8).

Der Abstand zwischen Türblätter und Türzargen sowie bei Schacht-Schiebetüren als Teleskoptüren zwischen den Tür-blättern darf 6mm nicht überschreiten. Der Luftspalt darf an den schließkanten bis 5mm breit, am Fußteil (Schwelle) bis 8mm breit sein. Beispiele siehe Bilder 9 bis 10.

BefestigungsmittelDie Befestigung am Kopf-und Fußteil kann erfolgen mittels• Ankerschienen } mit Ankerschrauben

• Stahdübeln }

• Steinschrauben }

• verankerter } Anschweißplatten

• Mauerankern } aus Stahl

Bei Schraubenbefestigungen ist mindestens die Schraubengröße M 12 zu verwenden.

AnschlußfugeDie Anschlußfuge zwischen Türzarge und angrenzender Schachtwand ist nach der Befestigung der Türzarge vollfugig und dicht mit Baustoffen der Klasse A nach DIN 4102 Teil 1 zu verschließen.

Es dürfen nur Befes-tingungselemente nach allgemeiner bauaufsichtlicher Zulassung verwendet werden.

Dübel nach bauauf-sichtlicher Zulassung

nach DIN 529

Mindestdike 6mm

Mindestquerschnitt 160mm2 Mindest-dicke 4mm

Page 20: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

37

HINWEISE ZUR INSTALLATION

*)Die Maße b1 und h1 sind identisch mit den lichten Durchgangs-maßen, weil die Zargenseitenteile und die Zargenoberteile nicht breiter bzw höher als 150 mm sein können. Bilder 1, 2, 3.

A Baustoffe der Klasse A nach DIN 4102 Teil 1 (nicht- brennbar) z.B. Mörtel

Page 21: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

38

Page 22: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

39

Untere Führung einer horizontal bewegten Schacht-Schiebetür mit Notführung

Page 23: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

40

PREVENTIVE MAINTENANCE FOR LANDING DOORS

1. Check and replace the electric contact (as necessary after approximately each 5 million cycles)

2. Periodically check that the gap between the landing door beak and the support of the electric contact is in accordance with the instructions (page 32 fig. 1)

3. Periodically check that the lock’s beak operates correctly

4. Periodically check that the panels’s movement plate ends resting on rubber stop

5. Periodically check (and adjust if necessary) the “gap” between the fast panel and the closing column of the frame (side opening doors)

6. Replace the guide shoes, when they seem to be worn

7. Periodically check and adjust the tension of the air cords. Replace them when they have signs of breaks or wear (approximately after 5 million cycles)

8. The synchronization wheels (aircord pulleys), need no maintenanc. Replace them when they have signs of wear, cracks or noisy operation, (approx. 8 million cycles)

9. Concentric and eccentric wheels of hanger plates need no maintenance. Replace them when they have signs of wear, noisy operation, (approx. 10 million cycles)

10. To prolong the life of the hanger wheels, keep the top tracks clean. Never apply grease to them

11. Periodically check the tension of the door closing spring. It should have sufficient strength to close and lock the door regardless of its position

Page 24: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

41

PREVENTIVE MAINTENANCE FOR LANDING DOORS

Page 25: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

42

NOTES:

Page 26: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

43

NOTES:

Page 27: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre
Page 28: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre
Page 29: ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ · •Hinged semi-automatic «Fermator» door without vision panel: PF 120min. 4023118 FRANCE •PRC2 2 Panel centre

Βιομηχανική Περιοχή Κιλκίς, 61100 ΕλλάδαΤηλ: 23410 75 730Fax: 23410 75 733

Kilkis Industrial Area,61100 GreeceTel: +30 23410 75 730Fax: +30 23410 75 733

www.klefer.gr, [email protected]