ΧΡΟΝΙΕΣ ΟΛΙΚΕΣ ΑΠΟΦΡΑΞΕΙΣ...Scoring Systems for Predicting Technical Success...

Post on 24-Sep-2020

4 views 0 download

Transcript of ΧΡΟΝΙΕΣ ΟΛΙΚΕΣ ΑΠΟΦΡΑΞΕΙΣ...Scoring Systems for Predicting Technical Success...

ΧΡΟΝΙΕΣ ΟΛΙΚΕΣ ΑΠΟΦΡΑΞΕΙΣ:

ΥΛΙΚΑ ΚΑΙ ΤΕΧΝΙΚΕΣ

Άννα Δαγρέ,PhD,FESC,FSCAIΓεν. Νοσοκομείο Ελευσίνας ‘’ΘΡΙΑΣΙΟ’’

ΠΑΝΕΛΛΗΝΙΑ ΣΕΜΙΝΑΡΙΑ ΟΜΑΔΩΝ ΕΡΓΑΣΙΑΣ ΕΚΕΘΕΣΣΑΛΟΝΙΚΗ, 09/02/2018

Disclosures

❖None

Right tool for the right reason

Overkill Knife to gunfight

Brilakis ES. Manual of coronary CTO interventions. Elsevier 2013

ANATOMY DICTATES STRATEGY

Scoring Systems for Predicting Technical Success of CTO

J-CTO score PROGRESS CTO score

Morino Y et al J Am Coll Cardiol Intv 2011;4:213-21 Christopoulos G et al J Am Coll Cardiol Intv 2016;9:1-9

CTO basics

1. Approach: Femoral – consider 45 cm sheath

Radial

2. Guide: 7 or 8 French – support

3. Virtually always: dual injections

RCA:AL type / LCA: XB,EBU typeSide holes +/--

Asahi Sion Family

‘’One minute guidewire’’

Tip load=0.8

Tip load=1.0

Tip load=0.6

XT- R/A : Core technology is the

same as ASAHI SION Family

Asahi Miracle/Confianza wire family

Confianza = tapered tip

Pro = hydrophilic coatingFor delivering Stingray

balloon

RETROGRADE CTO PCI

VERY COMPLEX COLLATERALS

ConstructionSUOH 03

Sianos G ‘’The Experts Live’’Workshop 2017

Features• Tip Load 0.3 gr, Coreless• Combination of Flexibility and maneuverability• Enhanced Tip Durability• Can not predict to navigate at discretion

SENTAI Guidewires

Fighter™ Specialty Crossing Wire

NameCoil

Diameter(inch)

TipDiameter

Length(cm)

Coil length(cm)

Radiopaque

(cm)Tip Load

(gf)Core

MaterialTip

ShapeCoating

FIGHTER 0.014 0.009190300

18 3.5 1.5Stainless

SteelStraight

Clear Polymer

Jacket w/Hydrophilic

Key Features

Tapered tip

Clear polymer jacket

Hydrophilic coating

Ideal prolapse wire

Moderate rail support

Radiopaque (3.5 cm)

0.0

09

inch

Polymer (Coil) Length (18cm)

Clear Polymer Jacket &Hydrophilic Coating

Stainless Steel Core

0.014 inch

PTFE Coating

NameCoil

Diameter(inch)

TipDiameter

(inch)

TotalLength

(cm)

Coil Length

(cm)

Radiop-aque(cm)

Tip Load (gf)

Penetration Force

(gf/mm2)

Core Material

TipShape

Coating

Hornet 0.014 0.008190300

15 3.5 1 31Stainless

SteelStraight Hydrophilic

Hornet 10 0.014 0.008190300

15 3.5 10 308Stainless

SteelStraight Hydrophilic

Hornet 14 0.014 0.008190300

15 3.5 14 432Stainless

SteelStraight Hydrophilic

Radiopaque (3.5 cm)

Coil Length(15cm) / Hydrophilic Coating

0.0

08

inch

Hydrophilic CoatingStainless Steel Core

0.014 inch

PTFE Coating

Hornet wire family

Penetration Power Hornet 10 > Confianza Pro 12

Length :190cm

Hydrophilic coating length : 40cm

Coil length : 15cm

Radiopaque length : 15cm

SLIP-COAT® Hydrophilic coating: 40cm

ASAHI Gaia Next 1 0.36mm/0.27mm (0.014inch/0.011inch)

ASAHI Gaia Next 2 0.36mm/0.30mm (0.014inch/0.012inch)

ASAHI Gaia Next 3 0.36mm/0.30mm (0.014inch/0.012inch)

Line-up & Technical Specs

Asahi Gaia Next

Line-up

Tip Load

To increase the penetration ability in a complex occlusion, the ASAHI GAIA Next series have higher tip loads

*The above data was obtained by company standardized test, which may differ from industry standardized tests.

*The above data does not prove that all devices have exactly the same performance with the samples used for these tests.

Asahi Gaia Next

Anti trapping performance

Asahi Gaia Next

Collateral crossing: septals

Possible sequence‘’Collateral Crossing’’

SION

SION Black (FFC)

XTR ( FXT)

Collateral crossing: epicardial

Possible sequence‘’Epicardial

Collateral Crossing’’

SION

SUOH

MICROCATHETERS

CORSAIR

- CWR and CCWR- Avoid too much rotation

(>10)

Corsair Pro

• Optimization of catheter stiffness profile

• Removing of coil marker

• Spiral protector

Improved performance

Tracking ability

Kink resistance at proximal shaft

Stiffer than Corsair

• Antegrade approach• More of a support catheter• Better for septals than epicardial

❖High Torque Response 1:1❖ Firm and Flexible shaft❖ Antegrade approach

0.62mm

CaravelTM Dis.

0.43mm

CaravelTM Prox.

0.55mm 0.85mm

Hydrophilic coating: 70/85cm

Microcatheters for antegrade CTO approach

Good Guiding Back-up

Not very calcified CTO lesions

Pushable MC

Finecross

M Cath

Less Guiding Back-up

Ostial or very proximal lesions,

planned ADR

Rotatable MC

Corsair

Turnpike

Spiral

Microcatheters for retrograde CTO approach

Septal Crossing

Rotatable MC

Finecross

Turnpike LP

Caravel

Epicardial Crossing

Low profile MC

Corsair

Turnpike

>1.5mm <1.5mm

Dual Lumen Microcatheters

Dual Lumen Catheters Applications

Trapliner

• Guide extension with an integrated trapping balloon for maintaining guidewire position

• 6F, 7F & 8F.

Trapper

Trapping Technique

Crossing and Re-entry Devices

• CrossBoss catheter

• Stingray balloon

• Stingray re-entry wire ( 300cm)

2.5/10mm

Stiff, metallic, OTW

Intravascular imaging

2.5 mm

Standard

Tip

Short Tip

Complication management

Covered stents

VI

HQ

Rel

ease

Feb

r. 1

9, 2

014

1 .5 71 .1 9

Crossing profile [mm diameter]

Data on file at BIOTRONIK; * Ø 2.5-4.0 mm

6 F5 F

2 4 % reduct ion

Guide catheter

com pat ibility*

Jostent Graftm aster 3 .0 / 1 6

Sandwich design

PK Papyrus 3 .0 / 1 5

Covered single stent design

Covered single stent design allow s for low crossing profile

and 5 F guide catheter com pat ibility*

Coils

Complication management

• Bacterial collagenase obtained by fermentation of Clostridium histolyticumUnlike human collagenase, bacterial collagenase cleaves human collagen at multiple sites for more rapid and effective digestion

• Lyophilized and stored at -20C providing 3-yr shelf life

• Re-suspended in 0.9% saline prior to injection into CTO

Intra-lesional collagenase MZ-004 for CTOs

Animal: Circulation 2003;108:1259

FIM: Circulation 2012;125:522

Novel Approach to CTO Under Investigation

Total Occlusion - 5

Total Occlusion Studies in Coronary Arteries (TOSCA) -5

Clinically Eligible and Consent Provided

Angiographically Eligibleday 0

day 1

Occlusion Confirmed

placebo 900 μg 1200 μg 12 minutes via microcatheterdouble blind

Antegrade CTO PCI

Next-day Discharge

30-day Follow-up

*dual injectionstart with soft polymer-jacketed

No rescue with:dissection re-entry

retrograde

echocardiogram

echocardiogram

echocardiogram

Confirmation of Occlusion:

1. documented failed attempt2. tap test: 1 minute attempt to

wire

N=75

Single large amplitudeshock wave

Mechanical amplifier

ConnectorPiezo driver

Single large amplitudeshock wave

Console(adjustable amplitude and rate)

Wire platform

SoundBite crossing system

Novel Approach to CTO Under Investigation

Kanno D et al Catheter Cardiovasc Interv. 2017;00:1–7.

Novel Approach to CTO Under Investigation

➢ A novel bi-polar RF wire system

➢ Plasma-mediated plaque ablation creates a channel inside a CTO

• Right tool + right time + right way = Success

• Stock appropriate tools for your practice

• Know how to use them

• Prepare for emergencies