Submersible Pump4” DMD-P Series

ΕΝ ISO 27001:2013No. : 0616364062745

A U S T R I AH E L L A S

Page 2: Submersible Pump 4” DMD-P Series - ALARKO CARRIER€¦ · Submersible Pump 4” DMD-P Series ... The intersection point (A) ... motor power as 1.1 kW. Order notation is determined

Alarko submersible pumpsare pumps that are always ready to use in usage and drinking water areas, problem-free, paying their investment

in a short time. THE ONLY UNINTERRUPTIBLE, PERSONAL WATER SOURCEWith its high efficiency and long life in industrial facility and establishments for providing

process and usage water A SUITABLE INVESTMENT.Especially in tourism season in touristic facilities

where water is needed more than ever, THE ONLY RELIABLE WATER SOURCE.

Superior thanks to their additional use as a waterbooster for storage of usage water of various purposed in all kinds of buildings from separate houses to skyscrapers, and thus they

are VERY FUNCTIONALFor gardening and agriculture; irrigating a small house garden or tens of thousands of acres of agricultural areas for gardeners and farmers makes Alarko submersible pumps A RELIABLE FRIEND.With its superior technology, economy, constant and quality service, fast spare part supply system, it is unrivaled.

Page 3: Submersible Pump 4” DMD-P Series - ALARKO CARRIER€¦ · Submersible Pump 4” DMD-P Series ... The intersection point (A) ... motor power as 1.1 kW. Order notation is determined

Submersible pump is your biggest helper

when present resources are inadequate and ground

waters should be extracted. It is unrivaled, problem-free and

economic in supplying drinking and usage waters. It is robust and long-lived

Especially in tourism season, in touristic facilities where water is needed more than ever, it helps the problem

of water be remedied in cases where city main is inadequate.

It is the most suitable solution for well water use in buildings, and car wash stations It is farmer and producer’s biggest friend in irrigation of

garden and agricultural areas. It overcomes water-problem and drought, and brings life to the soil and abundance to the produce. Alarko Diamond submersible pumps meet all your needs with 5 type, 43 models and high-reliability components

with a capacity interval of 0,5-18 m3/hour.

Suction Case:

Durability and pump life is extended against aggressive well waters by Cu ASTM280 material with high corrosion resistance.

Valve Table and Bearing:

Durability and pump life is extended against aggressive well waters by “Fiberglas Reinforces Thermoplastic” material with high corrosion resistance.

Impellers:

Pump life and efficiency is increased with “Acetal” material with low surface roughness, and durable against sand abrasion. It is designed with floating fan against sand jamming.

Diffuser and Impeller Cover:

The stainless bearing fitted over the diffuser and diffuser cap provides high abrasion strength. It is manufactured from polycarbonate material.

Page 4: Submersible Pump 4” DMD-P Series - ALARKO CARRIER€¦ · Submersible Pump 4” DMD-P Series ... The intersection point (A) ... motor power as 1.1 kW. Order notation is determined

GENERAL PUMP CURVES

ELECTRICAL FEATURES, DIMENSIONS AND WEIGHTS

96

B

A

Nominal Current Total Dimension (A) Approximate (mm)

220 V 380 V 220 V 380 V

Total Weight Approximate (Kg)

220 V 380 V

811162228385062

579

131724324050

579

121521283644

57

1014182228

57

11151923

0,50,75

11,5234

5,5

0,50,75

11,5234

5,57,5

0,50,75

11,5234

5,57,5

11,5234

5,57,5

1,5234

5,57,5

3,54,668

10,515--

3,54,668

10,515---

3,54,668

10,515---

68

10,515---

810,515---

1,62

2,73,44,36,38,5

10,3

1,62

2,73,44,36,38,5

10,312,3

1,62

2,73,44,36,38,5

10,312,3

2,73,44,36,38,5

10,312,3

3,44,36,38,5

10,312,3

741831985

117514061749

682754840993

11561479

726807903

104211901513

797913

10781323

88910371324

741831970

1.1551.3711.7092.0582.454

682754825973

1.1211.4391.7152.0062.416

726807888

102211551473175320822473

691893

10431283151717352060

86910021284156018202111

10,411,914,417,721,328,3

10,211,413,316,119,425,8

10,411,713,616,219,325,5

12,715,118,123,8

15,418,424,4

10,111,513,416,519,426,131,637,7

9,911

12,314,917,523,628,333,740,4

10,111,312,615

17,423,327,833,239,5

11,713,916,221,625,329,735,5

14,216,522,226,230,936,4

4002DMD-P

4004DMD-P

4006DMD-P

4010DMD-P

4012DMD-P

Pipe Thread ISO

228-G1 ¼

Pipe Thread ISO

228-G1 ¼

Pipe Thread ISO

228-G1 ½

Pipe Thread ISO

228-G2

Pipe Thread ISO

228-G2

Numberof Stages

Pump Exit Diameter

Motor Power(HP)

PumpType

“General Selection Chart” is used to determine the pump type zone that the intersection of the desired flow rate and manometric height (A) remains in. If the well diameter is 4”, flow rate (Q) is 3 m³ /hour and manometric height (H) is 75 mWc; on “Pump General Curves” the 3 m³ / hour on the horizontal axis and 75 mWc points on the vertical axis are intersected. The intersection point (A) remains inside the 4 SD / SDM 4 type pump zone. From here, the 4 SD / SDM 4 type pump “Independent Characteristic Curve” is consulted. 3 m³ /hour and 75 mWc point intersection point is on the 13th stage curve. Pump stage is selected as 13. “Electrical Characteristics, Dimensions and Weights Table” shows the pump motor power as 1.1 kW. Order notation is determined as 4 SD / SDM 4/13 DMD-P+1.1 kW.

4 S

D /

SD

M 4

DM

D-P

H (m

Wc)

500

450

400

350

300

250

200

150

100

50

0Eta (%)

60

40

20

00

0 1 2 3 4 5 6

10 20 30 40 50 60 70 80 90 100

1500

feet

1350

1200

1050

900

750

600

450

300

150

0

I/min

m3/h

US g.p.m

Imp g.p.m0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25

0 2.5 5 7.5 10 12.5 15 17.5 20

4004 / 45

4004 / 40

4004 / 32

4004 / 24

4004 / 17

4004 / 13

4004 / 94004 / 74004 / 5

A

Pump TypeNumber

of StagesMotor Power

(HP)

Nominal Current(A)

Total Dimension Approximate (mm)

Total Weight Approximate (Kg)

Pump Exit

Diameter

B220 V 380 V 220 V 380 V 220 V 380 V

4 SD / SDM 2DMD-P

8 0.5 3.5 1.6 741 741 10.4 10.1

Pipe Thread ISO 228-G1 ¼

11 0z 75 4.6 2 831 831 11.9 11.516 1 6 2.7 985 970 14.4 13.422 1.5 8 3.4 1175 1.155 17.7 16.528 2 10.5 4.3 1406 1.371 21.3 19.438 3 15 6.3 1749 1.709 28.3 26.150 4 - 8.5 2.058 31.662 5.5 - 10.3 2.454 37.7

4 SD /SDM 4DMD-P

5 0.5 3.5 1.6 682 682 10.2 9.9

Pipe Thread ISO 228-G1 ¼

7 0.75 4.6 2 754 754 11.4 119 1 6 2.7 840 825 13.3 12.313 1.5 8 3.4 993 973 16.1 14.917 2 10.5 4.3 1156 1.121 19.4 17.524 3 15 6.3 1479 1.439 25.8 23.632 4 - 8.5 1.715 28.340 5.5 - 10.3 2.006 33.745 7.5 - 12.3 2.203 37

4 SD /SDM 6DMD-P

5 0.5 3.5 1.6 726 726 10.4 10.1

Pipe Thread ISO 228-G1 ½

7 0.75 4.6 2 807 807 11.7 11.39 1 6 2.7 903 888 13.6 12.612 1.5 8 3.4 1042 1022 16.2 1515 2 10.5 4.3 1190 1155 19.3 17.421 3 15 6.3 1513 1473 25.5 23.328 4 - 8.5 1753 27.836 5.5 - 10.3 2082 33.244 7.5 - 12.3 2473 39.5

4 SD /SDM 10DMD-P

5 1 6 2.7 797 691 12.7 11.7

Pipe Thread ISO 228-G

2

7 1.5 8 3.4 913 893 15.1 13.910 2 10.5 4.3 1078 1043 18.1 16.214 3 15 6.3 1323 1283 23.8 21.618 4 - 8.5 1517 25.322 5.5 - 10.3 1735 29.728 7.5 - 12.3 2060 35.5

4 SD /SDM 12DMD-P

5 1.5 8 3.4 889 869 15.4 14.2

Pipe Thread ISO 228-G

2

7 2 10.5 4.3 1037 1002 18.4 16.511 3 15 6.3 1324 1284 24.4 22.215 4 - 8.5 1560 26.219 5.5 - 10.3 1820 30.923 7.5 - 12.3 2111 36.4

4 SD /SDM 16DMD-P

4 1.5 8 3.4 901 881 14.0 13.0

Pipe Thread ISO 228-G

2

6 2 10.5 4.3 1038 1053 17.2 15.59 3 15 6.3 1416 1378 23.4 21.212 4 - 8.5 - 1633 - 25.216 5.5 - 10.3 - 2008 - 30.220 7.5 - 12.3 - 2376 - 36.1

Page 5: Submersible Pump 4” DMD-P Series - ALARKO CARRIER€¦ · Submersible Pump 4” DMD-P Series ... The intersection point (A) ... motor power as 1.1 kW. Order notation is determined

4 SD / SDM 2 DMD-P

Q (m3/h)

H (m

Wc)

l/min

0

0

Eta(%)

0

0

20

40

60

50

100

150

200

250

300

350

400

450

500

10 20 30 40 50 60 70 80 90 100

1 2 3 4 5 6

4004/40

4004/45

4004/32

4004/24

4004/17

4004/13

4004/94004/74004/5

MODEL P2 n ≈2850 1/min

1 ~ 220V / 240V

3 ~ 220V / 240V

KW HP nm3 / h 0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3l / min 0 5 10 15 20 25 30 35 40 45 50 55

4SD / SDM 8 DMD-P 4SD / SDM 8 DMD-P 0.37 0.5

H (m)

58 58 57 56 54 52 50 46 42 36 30 25

4SD / SDM 11 DMD-P 4SD / SDM 11 DMD-P 0.55 0.75 80 79 78 77 75 72 68 63 57 50 42 34

4SD / SDM 16 DMD-P 4SD / SDM 16 DMD-P 0.75 1 116 116 114 112 109 105 99 92 83 73 61 50

4SD / SDM 22 DMD-P 4SD / SDM 22 DMD-P 1.1 1.5 160 159 157 154 150 144 136 126 114 100 84 68

4SD / SDM 28 DMD-P 4SD / SDM 28 DMD-P 1.5 2 204 202 200 196 191 183 173 161 145 127 107 87

4SD / SDM 38 DMD-P 4SD / SDM 38 DMD-P 2.2 3 276 275 271 266 259 249 235 218 197 173 145 118

- 4SD / SDM 50 DMD-P 3 4 364 361 356 350 340 327 310 287 260 227 190 155

- 4SD / SDM 62 DMD-P 4 5.5 451 448 442 434 422 406 384 356 322 282 236 192

PERFORMANCE TABLE (50Hz)

Page 6: Submersible Pump 4” DMD-P Series - ALARKO CARRIER€¦ · Submersible Pump 4” DMD-P Series ... The intersection point (A) ... motor power as 1.1 kW. Order notation is determined

4 SD / SDM 4 DMD-P

Q (m3/h)

H (m

Wc)

l/min

0

0

Eta(%)

0

0

20

40

60

50

100

150

200

250

300

350

400

450

500

10 20 30 40 50 60 70 80 90 100

1 2 3 4 5 6

4004/40

4004/45

4004/32

4004/24

4004/17

4004/13

4004/94004/74004/5

MODEL P2 n ≈2850 1/min

1 ~ 220V / 240V

3 ~ 380V / 415V

KW HP nm3 / h 0 0.6 1.2 1.8 2.4 3.0 3.6 4.2 4.8 5.4 6.0l / min 0 10 20 30 40 50 60 70 80 90 100

4SD / SDM 5 DMD-P 4SD / SDM 5 DMD-P 0.37 0.5

H (m)

39 37 36 35 34 32 29 26 23 18 144SD / SDM 7 DMD-P 4SD / SDM 7 DMD-P 0.55 0.75 54 52 51 49 48 45 41 37 32 26 194SD / SDM 9 DMD-P 4SD / SDM 9 DMD-P 0.75 1 70 67 65 63 61 57 53 48 41 33 25

4SD / SDM 13 DMD-P 4SD / SDM 13 DMD-P 1.1 1.5 101 97 94 91 88 83 76 69 59 48 364SD / SDM 17 DMD-P 4SD / SDM 17 DMD-P 1.5 2 131 126 123 120 116 109 100 90 77 62 464SD / SDM 24 DMD-P 4SD / SDM 24 DMD-P 2.2 3 186 178 174 169 163 153 141 127 109 88 66

- 4SD / SDM 32 DMD-P 3 4 247 238 231 225 218 204 188 170 145 117 87- 4SD / SDM 40 DMD-P 4 5.5 309 297 289 281 272 255 235 212 181 147 109

- 4SD / SDM 45 DMD-P 5.5 7.5 387 372 362 352 340 319 294 265 227 183 137

PERFORMANCE TABLE (50Hz)

Page 7: Submersible Pump 4” DMD-P Series - ALARKO CARRIER€¦ · Submersible Pump 4” DMD-P Series ... The intersection point (A) ... motor power as 1.1 kW. Order notation is determined

4 SD / SDM 6 DMD-P

MODEL P2 n ≈2850 1/min

1 ~ 220V / 240V

3 ~ 380V / 415V

KW HP nm3 / h 0 1.2 2.4 3.6 4.8 6.0 7.2 8.4l / min 0 20 40 60 80 100 120 140

4SD / SDM 5 DMD-P 4SD / SDM 5 DMD-P 0.37 0.5

H (m)

32 31 29 27 25 21 16 114SD / SDM 7 DMD-P 4SD / SDM 7 DMD-P 0.55 0.75 45 44 41 38 35 30 23 154SD / SDM 9 DMD-P 4SD / SDM 9 DMD-P 0.75 1 58 57 53 49 45 38 30 194SD / SDM 12 DMD-P 4SD / SDM 12 DMD-P 1.1 1.5 77 75 70 65 60 51 39 254SD / SDM 15 DMD-P 4SD / SDM 15 DMD-P 1.5 2 97 94 88 81 75 64 49 324SD / SDM 21 DMD-P 4SD / SDM 21 DMD-P 2.2 3 135 132 123 114 105 89 69 44

- 4SD / SDM 28 DMD-P 3 4 180 176 164 152 139 119 92 59- 4SD / SDM 36 DMD-P 4 5.5 232 226 210 195 179 153 118 76

- 4SD / SDM 44 DMD-P 5.5 7.5 283 277 257 239 219 187 145 93

PERFORMANCE TABLE (50Hz)

Q (m3/h)

H (m

Wc)

4006/36

4006/44

4006/28

4006/21

4006/15

4006/12

4006/94006/74006/5

Page 8: Submersible Pump 4” DMD-P Series - ALARKO CARRIER€¦ · Submersible Pump 4” DMD-P Series ... The intersection point (A) ... motor power as 1.1 kW. Order notation is determined

4 SD / SDM 10 DMD-P

Q (m3/h)

H (m

Wc)

0

25

50

75

100

125

150

175

200

225

0

l/min0 30 60 90 120 150 180 210 2400

2 4 6 8 10 12 14

20

40

60Eta(%)

4010/28

4010/22

4010/18

4010/6

4010/10

4010/14

4010/4

PERFORMANCE TABLE (50Hz)

MODEL P2 n ≈2850 1/min

1 ~ 220V / 240V

3 ~ 380V / 415V

KW HP nm3 / h 0 1.8 3.6 5.4 7.2 9.0 10.8 12.6 14.4l / min 0 30 60 90 120 150 180 210 240

4SD / SDM 4 DMD-P 4SD / SDM 4 DMD-P 0.75 1

H (m)

25 24 23 21 20 18 14 10 64SD / SDM 7 DMD-P 4SD / SDM 7 DMD-P 1.1 1.5 43 42 40 37 35 31 25 18 104SD / SDM 10 DMD-P 4SD / SDM 10 DMD-P 1.5 2 62 59 56 54 50 44 36 26 144SD / SDM 14 DMD-P 4SD / SDM 14 DMD-P 2.2 3 86 83 79 75 70 62 51 36 20

- 4SD / SDM 18 DMD-P 3 4 111 107 102 96 90 79 65 47 26- 4SD / SDM 22 DMD-P 4 5.5 136 131 124 118 110 97 80 57 32

- 4SD / SDM 28 DMD-P 5.5 7.5 173 166 158 15 140 124 101 72 40

Page 9: Submersible Pump 4” DMD-P Series - ALARKO CARRIER€¦ · Submersible Pump 4” DMD-P Series ... The intersection point (A) ... motor power as 1.1 kW. Order notation is determined

4 SD / SDM 12 DMD-P

Q (m3/h)

H (m

Wc)

0

200

Eta(%)

25

50

75

100

125

150

175

0

l/min0 30 60 90 120 150 180 210 240 270

2 4 6 8 10 12 14 16

0

20

40

60

4012/19

4012/15

4012/11

4012/7

4012/5

4012/23

PERFORMANCE TABLE (50Hz)

MODEL P2 n ≈2850 1/min

1 ~ 220V / 240V

3 ~ 380V / 415V

KW HP nm3 / h 0 1.8 3.6 5.4 7.2 9.0 10.8 12.6 14.4 16.2l / min 0 30 60 90 120 150 180 210 240 270

4SD / SDM 5 DMD-P 4SD / SDM 5 DMD-P 1.1 1.5

H (m)

32 31 29 27 25 22 20 16 12 74SD / SDM 7 DMD-P 4SD / SDM 7 DMD-P 1.5 2 45 43 40 37 34 31 28 23 18 104SD / SDM 11 DMD-P 4SD / SDM 11 DMD-P 2.2 3 70 67 63 59 55 49 43 36 27 16

- 4SD / SDM 15 DMD-P 3 4 96 92 86 81 74 67 59 49 37 22- 4SD / SDM 19 DMD-P 4 5.5 121 116 109 102 94 85 75 62 47 28- 4SD / SDM 23 DMD-P 5.5 7.5 147 140 132 124 114 102 90 75 56 33

Page 10: Submersible Pump 4” DMD-P Series - ALARKO CARRIER€¦ · Submersible Pump 4” DMD-P Series ... The intersection point (A) ... motor power as 1.1 kW. Order notation is determined

4 SD / SDM 16 DMD-P

PERFORMANCE TABLE (50Hz)

MODEL P2 n ≈2850 1/min

1 ~ 220V / 240V

3 ~ 380V / 415V

KW HP nm3 / h 0 3 6 9 12 15 18 21l / min 0 50 100 150 200 250 300 350

4SD / SDM 4 DMD-P 4SD / SD 4 DMD-P 1.1 1.5

H (m)

24 23 22 20 18 15 12 84SD / SDM 6 DMD-P 4SD / SD 6 DMD-P 1.5 2 36 35 33 30 26 23 18 124SD / SDM 9 DMD-P 4SD / SD 9 DMD-P 2.2 3 54 52 50 45 40 34 28 19

- 4SD / SD 12 DMD-P 3 4 71 70 66 60 53 45 37 25- 4SD / SD 16 DMD-P 4 5.5 95 93 89 80 71 61 49 33- 4SD / SD 20 DMD-P 5.5 7.5 119 117 111 100 88 76 62 42

H (m

Wc) 150

125

100

75

50

25

0

60

40

20

00 50 100 150 200 250 300 350 I/min

0 52.5 7.5 10 15 2012.5 17.5 22.5 m3/h

Eta (%)

4SD16/20

4SD16/16

4SD16/12

4SD16/9

4SD16/6

4SD16/4

Page 11: Submersible Pump 4” DMD-P Series - ALARKO CARRIER€¦ · Submersible Pump 4” DMD-P Series ... The intersection point (A) ... motor power as 1.1 kW. Order notation is determined

4

1

2

3

5

6

7

9

8

1011

12

MAIN PARTS / STANDARD CONSTRUCTION

STANDARD ELECTRICAL CONTROL PANEL PARTS

1- CASING: It is on the upper part of the pump. Pump exit connection is made here. It is manufactured from

Bronze material (Cu ASTM 280)

2- CHECK VALVE: It is inside the valve body. Prevents the return of the pumped water.

3- BODY PIPE: It holds together the pump stages that are stacked between

the suction mouth and valve body. It is manufactured from AISI 304 stainless steel material.

4- BEARING BODY: Centralizes the pump shaft through the bearings.

5- PUMP SHAFT: It is fixed to the motor shaft through special coupling. It is of hexagon type, made of

AISI 304 stainless steel material.

6- DIFFUSER: Enables the water to be transferred suitably between stages.

It is manufactured from polycarbonate material.

7- IMPELLER: There is one fan in every stage. It is designed with floating impeller against sand jamming. It is

manufactured from acetal material.

8- SUCTION STAINER: Prevents entrance of particles of size that can damage the pump.

9- SUCTION CASE: Enables the pump and motor to be connected to each other. Water enters the pump

through the suction opening. It has a suction filter that prevents large particles from entering. It is manufactured

from Bronze material (Cu ASTM 280)

10- COUPLING: Connects the pump and motor shaft, manufactured from AISI 304

or AISI 316 stainless steel material.

11- ELECTRICAL CABLE: Special underwater electrical cable. Has number of lines and cross section

suitable for the motor.

12- MOTOR: Manufactured suitably for operating underwater. The bearings that carry radial and axial loads are

lubricated and cooled with the special liquid filled inside the motor. Motor is started directly.

Energy Control Lamp: Displays whether there is power feed to the panel.

Main Switch: Turns on/off the power feed to the panel.

Control Switch: Powers the motor.

Water Level Automat: Controls the pump’s activation/deactivation automatically according to the well water level. Prevents the pump from operating without water. Water level servo is a set with level control electrodes and electrode cable assembly.

Phase (Motor) Control Relay and Warning Lamp: Prevents the three-phase motors from being left with two phases. It also provides protection by stopping the pump in phase instabilities in the power main.

Fuses: Protection against short circuit.

Thermal Relay: Protection against excessive load

Warning Lamps: “Malfunction”, ”Operation”, “Well Without Water” lamps. Enables easy monitoring of the pump operation

Amperometer and Voltmeter: Current and voltage values can be measured. (Optional)

4SD / SDM 2, 4, 6, 10, 12, 16 DMD-P Models

Electrical Cable Selection ChartNOMINALVOLTAGE

Motor Power Cable Section (mm2)

Max

imum

Cab

le L

engt

h (m

)

kW HP 1.5 2.5 4 6 10 16

MONOPHASE220 V

0.37 0.5 71 118 190 285 495 7760.55 0.75 55 92 149 223 386 6040.75 1 45 74 120 179 308 4791.1 1.5 30 50 81 121 209 3251.5 2 24 40 64 96 166 259

TRIPHASE380 V

0.37 0.5 479 796 - - - -0.55 0.75 352 586 940 - - -0.75 1 267 325 713 1064 - -1.1 1.5 196 244 522 779 - -1.5 2 147 173 392 585 1000 -2.2 3 104 126 277 413 707 10903 4.0 76 99 203 302 518 7984 5.5 59 87 159 237 406 626

4.4 6 21 104 139 207 355 5485.5 7.5 41 69 110 165 283 4377.5 10 - 50 81 121 207 320

Page 12: Submersible Pump 4” DMD-P Series - ALARKO CARRIER€¦ · Submersible Pump 4” DMD-P Series ... The intersection point (A) ... motor power as 1.1 kW. Order notation is determined

ALARKO CARRIERSANAYİ VE TİCARET A.Ș.

The right to amend specifications under technologic developments is reserved

GOSB-Gebze Organize Sanayi Bölgesi

Șahabettin Bilgisu Cad. 41480 Gebze-Kocaeli/TURKEY

Phone : (90)(262) 648 60 00 PBX

Telefax : (90)(262) 648 61 01

web : www.alarko-carrier.com.tr

e-mail : [email protected]

D.1.

1.14

i 091

216

MiN

ERAL

Application Methods Placing within a Wide Well Placing within a Normal Well Placing within a Large Well

Delivery Pipe

Electrical Cable

Cable Clamp

Suction Stainer

Check Valve

Pump

Motor

Cobblestone

A

Delivery Pipe

Manometer

Electrode

50 cm

H

Electrical Cable

Cable Clamp

Suction Stainer

Cobblestone

Check Valve

Pump

Motor

Manometer

Ventilation

PowerCord

Well Opening Flange

Protective Pipe

Delivery Pipe

Electrical Cable

Cable Clamp

Check Valve

Pump

Suction Stainer

Motor

Filter

Electrode

300

cmH

cm

PowerCord

Control panel

Valve Manometer Connection

Valve

Ventilation

Profile

Well Cover

Entry Cover

Cable Shall be Knotted

DETAIL-A

H= 0,3 m (if B+9>NPSH)H= NPSH-(B+9) (if B+9<NPSH)B: Pump height

FOR SECURE AND EFFICIENT USE

• The well water temperature and the amount of sand in the well water

must be analyzed in a laboratory. The maximum sand amount in the

well water must be 25 gr/m³, and maximum well water temperature

must be 40˚C.

• Pipes and pipe clamps must have enough strength to carry the pump

group, the water in the vertical pipe and its own weight.

• It is recommended that thee well diameter is at least 2” (inches) larger

than the pump diameter.

• The distance between the pump suction filter and well filter must have

maximum distance.

• The lower end of the motor and the well bottom must be at least 50 cm apart. The height of the pump descending into the well is

determined accordingly.

• The assembly depth of the pump is the Net Positive Suction Height which is the minimum depth that the pump can operate without sucking air.

Must be suitable to (NPSH) values.

ORDER NOTATION

4 SD / SDM 4 / 13 + 1.5HP - T. 30Electrical Cable Length (m)

T: There is an electrical control panel.

Y: There is no electrical control panel.

Motor Power

Number of Stages

Pump Type

TECHNICAL SPECIFICATIONS

Operation Voltage 3~380 V 1~220 V

Permissible Maximum Voltage Change -10.....+10 % + %5,-%10

Frequency 50 Hz

Pump Type 4SD / SDM 2,4,6,10,12,16

Motor RPM 2850 Rev / Min

Permissible Maximum Starts per Hour 30

Maximum Well Water Temperature 40ºC