Download - ESLON DC ESD

Transcript
Page 1: ESLON DC ESD

ELECTRICAL Method Unit PMMA AC 405 AS clear ESD-StandardSurface resistivityElectrostatic dischargeDielectric constant

ESLON®-DC ESDPMMA AC 405 ASStatic dissipative (antistatic) plastic sheets

ESLON DC ESD

ASTM D-257 DIN 53482 IEC 60093 Ω/* 106 ~ 107

MIL B-81705B s < 0.1ASTM D-150 DIN 53483 IEC 60250 3

ASTM D-792 DIN 53479 ISO 1183 g/cm³ 1.19ASTM D-270 DIN 53495 ISO 62A % 0.3JIS K5400 2HJIS D0202 - 100/100

ASTM D-1003 ISO 13468 % 85ASTM D-1003 ISO 14782 % 2ASTM D-542 ISO 489 - 1.49JIS K7105 % 90

ASTM D-648 DIN 53461 ISO 75 °C 90ASTM D-696 ISO 11359 mm/mm °C 7 x 10-5

ASTM C-177 W/mK 0.21ASTM C-177 KJ/kgK 1.47JIS K6745 % -UL 94 -

ASTM D-638 DIN 53455 ISO 527 MPa 74.5ASTM D-638 DIN 53455 ISO 527 % 5ASTM D-790 DIN 53452 ISO 178 MPa 117.7ASTM D-790 ISO 178 2900ASTM D-695 ISO 604 MPa - ISO 179 kJ/m² 20.3ASTM D-256 ISO 180 J/m 2.0

TECHNICAL CHARACTERISTICS

OPTICALLight transmittanceHazeRefractive indexDistinctness of image (DOI)

MECHANICALTensile strengthTensile elongation at breakFlexural strengthFlexural modulusCompressive strengthCharpy impact strength (23°C)Notched impact strength (23°C)

PHYSICALDensityWater absorptionPencil hardnessGrid adhesiveness

THERMALHeat deflection temperatureCoefficient of linear thermal expansionThermal conductivitySpecific heatHeat shrinkageFlammability

SEKISUI Chemical GmbHKönigsallee 106 | 40215 Düsseldorf, Germany | Tel.: +49-(0)211 - 369770 | Fax.: +49-(0)211 - 3697732 | http://www.eslon-dc.de | [email protected] not otherwise mentioned all data refer to a sheet thickness of 3mm. All data show the typical values, no guaranteed values for specification purpose. Date of publication: 18.04.2016