Download - CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Transcript
Page 1: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/3/2012

CDMA BC1 (Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.382 mho/m; εr = 39.345; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.51, 7.51, 7.51); Calibrated: 2/16/2012 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629

LHS/Touch_RC3 SO55_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.835 mW/g

LHS/Touch_RC3 SO55_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 24.729 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 1.0330 SAR(1 g) = 0.714 mW/g; SAR(10 g) = 0.465 mW/g Maximum value of SAR (measured) = 0.850 mW/g

0 dB = 0.850mW/g = -1.41 dB mW/g

Page 2: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/3/2012

CDMA BC1 (Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.382 mho/m; εr = 39.345; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.51, 7.51, 7.51); Calibrated: 2/16/2012 - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629

LHS/Tilt_RC3 SO55_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.541 mW/g

LHS/Tilt_RC3 SO55_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 19.889 V/m; Power Drift = 0.09 dB Peak SAR (extrapolated) = 0.6890 SAR(1 g) = 0.448 mW/g; SAR(10 g) = 0.274 mW/g Maximum value of SAR (measured) = 0.535 mW/g

0 dB = 0.540mW/g = -5.35 dB mW/g

Page 3: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/3/2012

CDMA BC1 (Primary Antenna)

Frequency: 1851.25 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1851.25 MHz; σ = 1.354 mho/m; εr = 39.427; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.51, 7.51, 7.51); Calibrated: 2/16/2012 - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629

RHS/Touch_RC3 SO55_ch 25/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.150 mW/g

RHS/Touch_RC3 SO55_ch 25/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 29.194 V/m; Power Drift = -0.0008 dB Peak SAR (extrapolated) = 1.6240 SAR(1 g) = 1.08 mW/g; SAR(10 g) = 0.671 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.308 mW/g

0 dB = 1.310mW/g = 2.35 dB mW/g

Page 4: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/2/2012

CDMA BC1 (Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.382 mho/m; εr = 39.345; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.51, 7.51, 7.51); Calibrated: 2/16/2012 - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629

RHS/Touch_RC3 SO55_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 1.283 mW/g

RHS/Touch_RC3 SO55_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 30.619 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 1.8010 SAR(1 g) = 1.18 mW/g; SAR(10 g) = 0.723 mW/g Maximum value of SAR (measured) = 1.444 mW/g

0 dB = 1.440mW/g = 3.17 dB mW/g

Page 5: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/2/2012

CDMA BC1 (Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1

RHS/Touch_RC3 SO55_ch 600/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm

Maximum value of SAR (measured) = 1.28 mW/g

Page 6: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/2/2012

CDMA BC1 (Primary Antenna)

Frequency: 1908.75 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1908.75 MHz; σ = 1.408 mho/m; εr = 39.207; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.51, 7.51, 7.51); Calibrated: 2/16/2012 - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629

RHS/Touch_RC3 SO55_ch 1175/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.276 mW/g

RHS/Touch_RC3 SO55_ch 1175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 30.433 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 1.8130 SAR(1 g) = 1.17 mW/g; SAR(10 g) = 0.714 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.438 mW/g

0 dB = 1.440mW/g = 3.17 dB mW/g

Page 7: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/2/2012

CDMA BC1 (Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.382 mho/m; εr = 39.345; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.51, 7.51, 7.51); Calibrated: 2/16/2012 - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629

RHS/Tilt_RC3 SO55_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.522 mW/g

RHS/Tilt_RC3 SO55_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 19.585 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 0.6500 SAR(1 g) = 0.429 mW/g; SAR(10 g) = 0.271 mW/g Maximum value of SAR (measured) = 0.512 mW/g

0 dB = 0.510mW/g = -5.85 dB mW/g

Page 8: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/3/2012

CDMA BC1 (Secondary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.382 mho/m; εr = 39.345; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.51, 7.51, 7.51); Calibrated: 2/16/2012 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629

LHS/Touch_RC3 SO55_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.503 mW/g

LHS/Touch_RC3 SO55_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 19.176 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 0.8280 SAR(1 g) = 0.428 mW/g; SAR(10 g) = 0.228 mW/g Maximum value of SAR (measured) = 0.571 mW/g

0 dB = 0.570mW/g = -4.88 dB mW/g

Page 9: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/3/2012

CDMA BC1 (Secondary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.382 mho/m; εr = 39.345; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.51, 7.51, 7.51); Calibrated: 2/16/2012 - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629

LHS/Tilt_RC3 SO55_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.545 mW/g

LHS/Tilt_RC3 SO55_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 19.880 V/m; Power Drift = -0.04 dB Peak SAR (extrapolated) = 0.9240 SAR(1 g) = 0.482 mW/g; SAR(10 g) = 0.256 mW/g Maximum value of SAR (measured) = 0.629 mW/g

0 dB = 0.630mW/g = -4.01 dB mW/g

Page 10: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/3/2012

CDMA BC1 (Secondary Antenna)

Frequency: 1851.25 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1851.25 MHz; σ = 1.354 mho/m; εr = 39.427; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.51, 7.51, 7.51); Calibrated: 2/16/2012 - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629

RHS/Touch_RC3 SO55_ch 25/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.867 mW/g

RHS/Touch_RC3 SO55_ch 25/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 25.499 V/m; Power Drift = -0.07 dB Peak SAR (extrapolated) = 1.3490 SAR(1 g) = 0.710 mW/g; SAR(10 g) = 0.366 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.984 mW/g

0 dB = 0.980mW/g = -0.18 dB mW/g

Page 11: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/3/2012

CDMA BC1 (Secondary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.382 mho/m; εr = 39.345; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.51, 7.51, 7.51); Calibrated: 2/16/2012 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629

RHS/Touch_RC3 SO55_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.889 mW/g

RHS/Touch_RC3 SO55_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 26.737 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 1.4670 SAR(1 g) = 0.761 mW/g; SAR(10 g) = 0.389 mW/g Maximum value of SAR (measured) = 1.059 mW/g

0 dB = 1.060mW/g = 0.51 dB mW/g

Page 12: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/3/2012

CDMA BC1 (Secondary Antenna)

Frequency: 1908.75 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1908.75 MHz; σ = 1.408 mho/m; εr = 39.207; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.51, 7.51, 7.51); Calibrated: 2/16/2012 - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629

RHS/Touch_RC3 SO55_ch 1175/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.190 mW/g

RHS/Touch_RC3 SO55_ch 1175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 29.033 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 1.7970 SAR(1 g) = 0.922 mW/g; SAR(10 g) = 0.468 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.234 mW/g

0 dB = 1.230mW/g = 1.80 dB mW/g

Page 13: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/3/2012

CDMA BC1 (Secondary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.382 mho/m; εr = 39.345; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.51, 7.51, 7.51); Calibrated: 2/16/2012 - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM; Type: QD000P40CD; Serial: 1629

RHS/Tilt_RC3 SO55_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.951 mW/g

RHS/Tilt_RC3 SO55_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 26.236 V/m; Power Drift = -0.09 dB Peak SAR (extrapolated) = 1.4620 SAR(1 g) = 0.722 mW/g; SAR(10 g) = 0.368 mW/g Maximum value of SAR (measured) = 0.942 mW/g

0 dB = 0.940mW/g = -0.54 dB mW/g

Page 14: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Primary Antenna)

Frequency: 1851.25 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1851.25 MHz; σ = 1.472 mho/m; εr = 52.372; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Rear/1xRTT_RC3_SO32_ch 25/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.28 mW/g

Rear/1xRTT_RC3_SO32_ch 25/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 30.174 V/m; Power Drift = -0.05 dB Peak SAR (extrapolated) = 2.015 mW/g SAR(1 g) = 1.11 mW/g; SAR(10 g) = 0.627 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.45 mW/g

0 dB = 1.45 mW/g = 3.23 dB mW/g

Page 15: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.505 mho/m; εr = 52.273; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Rear/1xRTT_RC3_SO32_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 1.31 mW/g

Rear/1xRTT_RC3_SO32_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 30.167 V/m; Power Drift = -0.06 dB Peak SAR (extrapolated) = 2.076 mW/g SAR(1 g) = 1.13 mW/g; SAR(10 g) = 0.642 mW/g Maximum value of SAR (measured) = 1.51 mW/g

0 dB = 1.51 mW/g = 3.58 dB mW/g

Page 16: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.505 mho/m; εr = 52.273; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Rear/1xRTT_RC3_SO32_ch 600 w/headset/Area Scan (7x11x1): Measurement grid: dx=15mm,

dy=15mm Maximum value of SAR (measured) = 1.37 mW/g

Rear/1xRTT_RC3_SO32_ch 600 w/headset/Zoom Scan (5x5x7)/Cube 0: Measurement grid:

dx=8mm, dy=8mm, dz=5mm Reference Value = 30.920 V/m; Power Drift = -0.04 dB Peak SAR (extrapolated) = 2.187 mW/g SAR(1 g) = 1.18 mW/g; SAR(10 g) = 0.646 mW/g Maximum value of SAR (measured) = 1.59 mW/g

0 dB = 1.59 mW/g = 4.03 dB mW/g

Page 17: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1

Rear/1xRTT_RC3_SO32_ch 600 w/headset/Z Scan (1x1x21): Measurement grid: dx=20mm,

dy=20mm, dz=5mm Maximum value of SAR (measured) = 1.39 mW/g

Page 18: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Primary Antenna)

Frequency: 1908.75 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1908.75 MHz; σ = 1.538 mho/m; εr = 52.192; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Rear/1xRTT_RC3_SO32_ch 1175/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.17 mW/g

Rear/1xRTT_RC3_SO32_ch 1175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 28.258 V/m; Power Drift = -0.13 dB Peak SAR (extrapolated) = 1.880 mW/g SAR(1 g) = 1.01 mW/g; SAR(10 g) = 0.582 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.32 mW/g

0 dB = 1.32 mW/g = 2.41 dB mW/g

Page 19: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Primary Antenna)

Frequency: 1851.25 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1851.25 MHz; σ = 1.472 mho/m; εr = 52.372; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Front/1xRTT_RC3_SO32_ch 25/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.01 mW/g

Front/1xRTT_RC3_SO32_ch 25/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 26.611 V/m; Power Drift = -0.08 dB Peak SAR (extrapolated) = 1.498 mW/g SAR(1 g) = 0.892 mW/g; SAR(10 g) = 0.523 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.15 mW/g

0 dB = 1.15 mW/g = 1.21 dB mW/g

Page 20: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.505 mho/m; εr = 52.273; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Front/1xRTT_RC3_SO32_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.912 mW/g

Front/1xRTT_RC3_SO32_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 25.010 V/m; Power Drift = -0.05 dB Peak SAR (extrapolated) = 1.416 mW/g SAR(1 g) = 0.825 mW/g; SAR(10 g) = 0.481 mW/g Maximum value of SAR (measured) = 1.08 mW/g

0 dB = 1.08 mW/g = 0.67 dB mW/g

Page 21: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Primary Antenna)

Frequency: 1908.75 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1908.75 MHz; σ = 1.538 mho/m; εr = 52.192; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Front/1xRTT_RC3_SO32_ch 1175/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.990 mW/g

Front/1xRTT_RC3_SO32_ch 1175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,

dy=8mm, dz=5mm Reference Value = 25.786 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 1.373 mW/g SAR(1 g) = 0.782 mW/g; SAR(10 g) = 0.447 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.992 mW/g

0 dB = 0.992 mW/g = -0.07 dB mW/g

Page 22: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Primary Antenna)

Frequency: 1851.25 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1851.25 MHz; σ = 1.472 mho/m; εr = 52.372; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 2/1xRTT_RC3_SO32_ch 25/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.874 mW/g

Edge 2/1xRTT_RC3_SO32_ch 25/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 24.931 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 1.154 mW/g SAR(1 g) = 0.700 mW/g; SAR(10 g) = 0.396 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.883 mW/g

Edge 2/1xRTT_RC3_SO32_ch 25/Zoom Scan 2 (5x5x7)/Cube 0: Measurement grid: dx=8mm,

dy=8mm, dz=5mm Reference Value = 24.931 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 0.961 mW/g SAR(1 g) = 0.593 mW/g; SAR(10 g) = 0.344 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.757 mW/g

0 dB = 0.757 mW/g = -2.42 dB mW/g

Page 23: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.505 mho/m; εr = 52.273; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 2/1xRTT_RC3_SO32_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 1.02 mW/g

Edge 2/1xRTT_RC3_SO32_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,

dy=8mm, dz=5mm Reference Value = 26.426 V/m; Power Drift = -0.04 dB Peak SAR (extrapolated) = 1.329 mW/g SAR(1 g) = 0.802 mW/g; SAR(10 g) = 0.454 mW/g Maximum value of SAR (measured) = 1.01 mW/g

Edge 2/1xRTT_RC3_SO32_ch 600/Zoom Scan 2 (5x5x7)/Cube 0: Measurement grid: dx=8mm,

dy=8mm, dz=5mm Reference Value = 26.426 V/m; Power Drift = -0.04 dB Peak SAR (extrapolated) = 1.028 mW/g SAR(1 g) = 0.635 mW/g; SAR(10 g) = 0.367 mW/g Maximum value of SAR (measured) = 0.814 mW/g

0 dB = 0.814 mW/g = -1.79 dB mW/g

Page 24: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Primary Antenna)

Frequency: 1908.75 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1908.75 MHz; σ = 1.538 mho/m; εr = 52.192; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 2/1xRTT_RC3_SO32_ch 1175/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.982 mW/g

Edge 2/1xRTT_RC3_SO32_ch 1175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,

dy=8mm, dz=5mm Reference Value = 25.755 V/m; Power Drift = -0.07 dB Peak SAR (extrapolated) = 1.325 mW/g SAR(1 g) = 0.789 mW/g; SAR(10 g) = 0.443 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.02 mW/g

Edge 2/1xRTT_RC3_SO32_ch 1175/Zoom Scan 2 (5x5x7)/Cube 0: Measurement grid: dx=8mm,

dy=8mm, dz=5mm Reference Value = 25.755 V/m; Power Drift = -0.07 dB Peak SAR (extrapolated) = 0.971 mW/g SAR(1 g) = 0.587 mW/g; SAR(10 g) = 0.337 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.750 mW/g

0 dB = 0.750 mW/g = -2.50 dB mW/g

Page 25: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Primary Antenna)

Frequency: 1851.25 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1851.25 MHz; σ = 1.472 mho/m; εr = 52.372; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 3/1xRTT_RC3_SO32_ch 25/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.18 mW/g

Edge 3/1xRTT_RC3_SO32_ch 25/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 28.783 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 1.818 mW/g SAR(1 g) = 0.870 mW/g; SAR(10 g) = 0.470 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.20 mW/g

0 dB = 1.20 mW/g = 1.58 dB mW/g

Page 26: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.505 mho/m; εr = 52.273; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 3/1xRTT_RC3_SO32_ch 600/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 1.03 mW/g

Edge 3/1xRTT_RC3_SO32_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,

dy=8mm, dz=5mm Reference Value = 26.526 V/m; Power Drift = 0.09 dB Peak SAR (extrapolated) = 1.504 mW/g SAR(1 g) = 0.876 mW/g; SAR(10 g) = 0.464 mW/g Maximum value of SAR (measured) = 1.13 mW/g

0 dB = 1.13 mW/g = 1.06 dB mW/g

Page 27: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Primary Antenna)

Frequency: 1908.75 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1908.75 MHz; σ = 1.538 mho/m; εr = 52.192; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 3/1xRTT_RC3_SO32_ch 1175/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.13 mW/g

Edge 3/1xRTT_RC3_SO32_ch 1175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,

dy=8mm, dz=5mm Reference Value = 27.355 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 1.530 mW/g SAR(1 g) = 0.889 mW/g; SAR(10 g) = 0.467 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.17 mW/g

0 dB = 1.17 mW/g = 1.36 dB mW/g

Page 28: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.505 mho/m; εr = 52.273; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 4/1xRTT_RC3_SO32_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.144 mW/g

Edge 4/1xRTT_RC3_SO32_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,

dy=8mm, dz=5mm Reference Value = 9.911 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 0.192 mW/g SAR(1 g) = 0.116 mW/g; SAR(10 g) = 0.067 mW/g Maximum value of SAR (measured) = 0.148 mW/g

Edge 4/1xRTT_RC3_SO32_ch 600/Zoom Scan 2 (5x5x7)/Cube 0: Measurement grid: dx=8mm,

dy=8mm, dz=5mm Reference Value = 9.911 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 0.113 mW/g SAR(1 g) = 0.064 mW/g; SAR(10 g) = 0.036 mW/g Maximum value of SAR (measured) = 0.0849 mW/g

0 dB = 0.0849 mW/g = -21.42 dB mW/g

Page 29: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Secondary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.505 mho/m; εr = 52.273; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Rear/1xRTT_RC3_SO32_ch 600/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.391 mW/g

Rear/1xRTT_RC3_SO32_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 16.265 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 0.536 mW/g SAR(1 g) = 0.318 mW/g; SAR(10 g) = 0.187 mW/g Maximum value of SAR (measured) = 0.393 mW/g

0 dB = 0.393 mW/g = -8.11 dB mW/g

Page 30: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Secondary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.505 mho/m; εr = 52.273; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Rear/1xRTT_RC3_SO32_ch 600 w/Headset/Area Scan (7x12x1): Measurement grid: dx=15mm,

dy=15mm Maximum value of SAR (measured) = 0.365 mW/g

Rear/1xRTT_RC3_SO32_ch 600 w/Headset/Zoom Scan (5x5x7)/Cube 0: Measurement grid:

dx=8mm, dy=8mm, dz=5mm Reference Value = 15.806 V/m; Power Drift = -0.00 dB Peak SAR (extrapolated) = 0.526 mW/g SAR(1 g) = 0.298 mW/g; SAR(10 g) = 0.171 mW/g Maximum value of SAR (measured) = 0.370 mW/g

0 dB = 0.370 mW/g = -8.64 dB mW/g

Page 31: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Secondary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.505 mho/m; εr = 52.273; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Front/1xRTT_RC3_SO32_ch 600/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.265 mW/g

Front/1xRTT_RC3_SO32_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 13.462 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 0.369 mW/g SAR(1 g) = 0.227 mW/g; SAR(10 g) = 0.137 mW/g Maximum value of SAR (measured) = 0.282 mW/g

0 dB = 0.282 mW/g = -11.00 dB mW/g

Page 32: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/5/2012

CDMA BC1 (Secondary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.505 mho/m; εr = 52.273; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 1/1xRTT_RC3_SO32_ch 600/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.198 mW/g

Edge 1/1xRTT_RC3_SO32_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,

dy=8mm, dz=5mm Reference Value = 11.703 V/m; Power Drift = -0.04 dB Peak SAR (extrapolated) = 0.279 mW/g SAR(1 g) = 0.153 mW/g; SAR(10 g) = 0.073 mW/g Maximum value of SAR (measured) = 0.206 mW/g

0 dB = 0.206 mW/g = -13.72 dB mW/g

Page 33: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1 (Secondary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.505 mho/m; εr = 52.273; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 2/1xRTT_RC3_SO32_ch 600/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.109 mW/g

Edge 2/1xRTT_RC3_SO32_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,

dy=8mm, dz=5mm Reference Value = 8.547 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 0.140 mW/g SAR(1 g) = 0.084 mW/g; SAR(10 g) = 0.047 mW/g Maximum value of SAR (measured) = 0.107 mW/g

Edge 2/1xRTT_RC3_SO32_ch 600/Zoom Scan 2 (5x5x7)/Cube 0: Measurement grid: dx=8mm,

dy=8mm, dz=5mm Reference Value = 8.547 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 0.141 mW/g SAR(1 g) = 0.083 mW/g; SAR(10 g) = 0.047 mW/g Maximum value of SAR (measured) = 0.108 mW/g

0 dB = 0.108 mW/g = -19.33 dB mW/g

Page 34: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1 (Secondary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.505 mho/m; εr = 52.273; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 4/1xRTT_RC3_SO32_ch 600/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.195 mW/g

Edge 4/1xRTT_RC3_SO32_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,

dy=8mm, dz=5mm Reference Value = 11.589 V/m; Power Drift = -0.14 dB Peak SAR (extrapolated) = 0.273 mW/g SAR(1 g) = 0.163 mW/g; SAR(10 g) = 0.092 mW/g Maximum value of SAR (measured) = 0.210 mW/g

Edge 4/1xRTT_RC3_SO32_ch 600/Zoom Scan 2 (5x5x7)/Cube 0: Measurement grid: dx=8mm,

dy=8mm, dz=5mm Reference Value = 11.589 V/m; Power Drift = -0.14 dB Peak SAR (extrapolated) = 0.182 mW/g SAR(1 g) = 0.109 mW/g; SAR(10 g) = 0.062 mW/g Maximum value of SAR (measured) = 0.139 mW/g

0 dB = 0.139 mW/g = -17.14 dB mW/g

Page 35: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Primary Antenna)

Frequency: 1851.25 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1851.25 MHz; σ = 1.487 mho/m; εr = 51.956; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Rear/1xEVDO_Rel.0_ch 25/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.31 mW/g

Rear/1xEVDO_Rel.0_ch 25/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 29.963 V/m; Power Drift = -0.09 dB Peak SAR (extrapolated) = 1.776 mW/g SAR(1 g) = 1.01 mW/g; SAR(10 g) = 0.569 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.33 mW/g

0 dB = 1.33 mW/g = 2.48 dB mW/g

Page 36: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.521 mho/m; εr = 51.862; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Rear/1xEVDO_Rel.0_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 1.38 mW/g

Rear/1xEVDO_Rel.0_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 30.756 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 1.995 mW/g SAR(1 g) = 1.1 mW/g; SAR(10 g) = 0.618 mW/g Maximum value of SAR (measured) = 1.48 mW/g

0 dB = 1.48 mW/g = 3.41 dB mW/g

Page 37: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.521 mho/m; εr = 51.862; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Rear/1xEVDO_Rel.0_ch 600 w/headset/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 1.47 mW/g

Rear/1xEVDO_Rel.0_ch 600 w/headset/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,

dy=8mm, dz=5mm Reference Value = 31.425 V/m; Power Drift = -0.07 dB Peak SAR (extrapolated) = 2.038 mW/g SAR(1 g) = 1.13 mW/g; SAR(10 g) = 0.614 mW/g Maximum value of SAR (measured) = 1.51 mW/g

0 dB = 1.51 mW/g = 3.58 dB mW/g

Page 38: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab A Date: 7/6/2012

CDMA BC1(Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1

Rear/1xEVDO_Rel.0_ch 600 w/headset/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm,

dz=5mm Maximum value of SAR (measured) = 1.447 mW/g

Page 39: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Primary Antenna)

Frequency: 1908.75 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1908.75 MHz; σ = 1.555 mho/m; εr = 51.774; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Rear/1xEVDO_Rel.0_ch 1175/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.30 mW/g

Rear/1xEVDO_Rel.0_ch 1175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 28.980 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 1.845 mW/g SAR(1 g) = 1.01 mW/g; SAR(10 g) = 0.571 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.37 mW/g

0 dB = 1.37 mW/g = 2.73 dB mW/g

Page 40: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Primary Antenna)

Frequency: 1851.25 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1851.25 MHz; σ = 1.487 mho/m; εr = 51.956; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Front/1xEVDO_Rel.0_ch 25/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.15 mW/g

Front/1xEVDO_Rel.0_ch 25/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 28.098 V/m; Power Drift = -0.04 dB Peak SAR (extrapolated) = 1.574 mW/g SAR(1 g) = 0.929 mW/g; SAR(10 g) = 0.535 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.21 mW/g

0 dB = 1.21 mW/g = 1.66 dB mW/g

Page 41: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.521 mho/m; εr = 51.862; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Front/1xEVDO_Rel.0_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 1.09 mW/g

Front/1xEVDO_Rel.0_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 27.525 V/m; Power Drift = -0.12 dB Peak SAR (extrapolated) = 1.519 mW/g SAR(1 g) = 0.895 mW/g; SAR(10 g) = 0.517 mW/g Maximum value of SAR (measured) = 1.16 mW/g

0 dB = 1.16 mW/g = 1.29 dB mW/g

Page 42: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Primary Antenna)

Frequency: 1908.75 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1908.75 MHz; σ = 1.555 mho/m; εr = 51.774; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Front/1xEVDO_Rel.0_ch 1175/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.08 mW/g

Front/1xEVDO_Rel.0_ch 1175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 26.523 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 1.505 mW/g SAR(1 g) = 0.860 mW/g; SAR(10 g) = 0.494 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.13 mW/g

0 dB = 1.13 mW/g = 1.06 dB mW/g

Page 43: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Primary Antenna)

Frequency: 1851.25 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1851.25 MHz; σ = 1.487 mho/m; εr = 51.956; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 2/1xEVDO_Rel.0_ch 25/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.786 mW/g

Edge 2/1xEVDO_Rel.0_ch 25/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 22.962 V/m; Power Drift = 0.10 dB Peak SAR (extrapolated) = 1.112 mW/g SAR(1 g) = 0.673 mW/g; SAR(10 g) = 0.383 mW/g Maximum value of SAR (measured) = 0.860 mW/g

Edge 2/1xEVDO_Rel.0_ch 25/Zoom Scan 2 (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 22.962 V/m; Power Drift = 0.10 dB Peak SAR (extrapolated) = 0.947 mW/g SAR(1 g) = 0.584 mW/g; SAR(10 g) = 0.342 mW/g Maximum value of SAR (measured) = 0.747 mW/g

0 dB = 0.747 mW/g = -2.53 dB mW/g

Page 44: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.521 mho/m; εr = 51.862; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 2/1xEVDO_Rel.0_ch 600/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.846 mW/g

Edge 2/1xEVDO_Rel.0_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 23.949 V/m; Power Drift = 0.10 dB Peak SAR (extrapolated) = 1.248 mW/g SAR(1 g) = 0.751 mW/g; SAR(10 g) = 0.425 mW/g Maximum value of SAR (measured) = 0.957 mW/g

Edge 2/1xEVDO_Rel.0_ch 600/Zoom Scan 2 (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 23.949 V/m; Power Drift = 0.10 dB Peak SAR (extrapolated) = 0.985 mW/g SAR(1 g) = 0.607 mW/g; SAR(10 g) = 0.353 mW/g Maximum value of SAR (measured) = 0.774 mW/g

0 dB = 0.774 mW/g = -2.23 dB mW/g

Page 45: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Primary Antenna)

Frequency: 1908.75 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1908.75 MHz; σ = 1.555 mho/m; εr = 51.774; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 2/1xEVDO_Rel.0_ch 1175/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.841 mW/g

Edge 2/1xEVDO_Rel.0_ch 1175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 23.257 V/m; Power Drift = -0.05 dB Peak SAR (extrapolated) = 1.223 mW/g SAR(1 g) = 0.730 mW/g; SAR(10 g) = 0.411 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.933 mW/g

Edge 2/1xEVDO_Rel.0_ch 1175/Zoom Scan 2 (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 23.257 V/m; Power Drift = -0.05 dB Peak SAR (extrapolated) = 0.940 mW/g SAR(1 g) = 0.572 mW/g; SAR(10 g) = 0.331 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.725 mW/g

0 dB = 0.725 mW/g = -2.79 dB mW/g

Page 46: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Primary Antenna)

Frequency: 1851.25 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1851.25 MHz; σ = 1.487 mho/m; εr = 51.956; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 3/1xEVDO_Rel.0_ch 25/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.06 mW/g

Edge 3/1xEVDO_Rel.0_ch 25/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 26.416 V/m; Power Drift = 0.14 dB Peak SAR (extrapolated) = 1.441 mW/g SAR(1 g) = 0.863 mW/g; SAR(10 g) = 0.464 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.12 mW/g

0 dB = 1.12 mW/g = 0.98 dB mW/g

Page 47: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.521 mho/m; εr = 51.862; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 3/1xEVDO_Rel.0_ch 600/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.919 mW/g

Edge 3/1xEVDO_Rel.0_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 25.028 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 1.357 mW/g SAR(1 g) = 0.799 mW/g; SAR(10 g) = 0.424 mW/g Maximum value of SAR (measured) = 1.04 mW/g

0 dB = 1.04 mW/g = 0.34 dB mW/g

Page 48: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Primary Antenna)

Frequency: 1908.75 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used (interpolated): f = 1908.75 MHz; σ = 1.555 mho/m; εr = 51.774; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 3/1xEVDO_Rel.0_ch 1175/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm

Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.969 mW/g

Edge 3/1xEVDO_Rel.0_ch 1175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 25.266 V/m; Power Drift = 0.10 dB Peak SAR (extrapolated) = 1.445 mW/g SAR(1 g) = 0.834 mW/g; SAR(10 g) = 0.439 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.10 mW/g

0 dB = 1.10 mW/g = 0.83 dB mW/g

Page 49: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/7/2012

CDMA BC1(Primary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.521 mho/m; εr = 51.862; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 4/1xEVDO_Rel.0_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.145 mW/g

Edge 4/1xEVDO_Rel.0_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 9.888 V/m; Power Drift = 0.14 dB Peak SAR (extrapolated) = 0.220 mW/g SAR(1 g) = 0.135 mW/g; SAR(10 g) = 0.079 mW/g Maximum value of SAR (measured) = 0.173 mW/g

Edge 4/1xEVDO_Rel.0_ch 600/Zoom Scan 2 (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 9.888 V/m; Power Drift = 0.14 dB Peak SAR (extrapolated) = 0.154 mW/g SAR(1 g) = 0.090 mW/g; SAR(10 g) = 0.052 mW/g Maximum value of SAR (measured) = 0.117 mW/g

0 dB = 0.117 mW/g = -18.64 dB mW/g

Page 50: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Secondary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.521 mho/m; εr = 51.862; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Rear/1xEVDO Rel.0_ch 600/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.384 mW/g

Rear/1xEVDO Rel.0_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 15.996 V/m; Power Drift = 0.07 dB Peak SAR (extrapolated) = 0.597 mW/g SAR(1 g) = 0.351 mW/g; SAR(10 g) = 0.206 mW/g Maximum value of SAR (measured) = 0.443 mW/g

0 dB = 0.443 mW/g = -7.07 dB mW/g

Page 51: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Secondary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.521 mho/m; εr = 51.862; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Rear/1xEVDO Rel.0_ch 600 w/Headset/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.343 mW/g

Rear/1xEVDO Rel.0_ch 600 w/Headset/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,

dy=8mm, dz=5mm Reference Value = 14.964 V/m; Power Drift = 0.11 dB Peak SAR (extrapolated) = 0.534 mW/g SAR(1 g) = 0.310 mW/g; SAR(10 g) = 0.179 mW/g Maximum value of SAR (measured) = 0.401 mW/g

0 dB = 0.401 mW/g = -7.94 dB mW/g

Page 52: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Secondary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.521 mho/m; εr = 51.862; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Front/1xEVDO Rel.0_ch 600/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.264 mW/g

Front/1xEVDO Rel.0_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 13.443 V/m; Power Drift = 0.07 dB Peak SAR (extrapolated) = 0.389 mW/g SAR(1 g) = 0.236 mW/g; SAR(10 g) = 0.138 mW/g Maximum value of SAR (measured) = 0.289 mW/g

0 dB = 0.289 mW/g = -10.78 dB mW/g

Page 53: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Secondary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.521 mho/m; εr = 51.862; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 1/1xEVDO Rel.0_ch 600/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.148 mW/g

Edge 1/1xEVDO Rel.0_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 9.834 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 0.256 mW/g SAR(1 g) = 0.145 mW/g; SAR(10 g) = 0.072 mW/g Maximum value of SAR (measured) = 0.187 mW/g

0 dB = 0.187 mW/g = -14.56 dB mW/g

Page 54: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Secondary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.521 mho/m; εr = 51.862; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 2/1xEVDO Rel.0_ch 600/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.0806 mW/g

Edge 2/1xEVDO Rel.0_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 7.420 V/m; Power Drift = 0.13 dB Peak SAR (extrapolated) = 0.115 mW/g SAR(1 g) = 0.070 mW/g; SAR(10 g) = 0.039 mW/g Maximum value of SAR (measured) = 0.0891 mW/g

Edge 2/1xEVDO Rel.0_ch 600/Zoom Scan 2 (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 7.420 V/m; Power Drift = 0.13 dB Peak SAR (extrapolated) = 0.106 mW/g SAR(1 g) = 0.064 mW/g; SAR(10 g) = 0.037 mW/g Maximum value of SAR (measured) = 0.0814 mW/g

0 dB = 0.0814 mW/g = -21.79 dB mW/g

Page 55: CDMA BC1 (Primary Antenna) - fccid.io€¦CDMA BC1 (Primary Antenna) Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0 C; Liquid Temperature: 23.0 C Medium parameters

Test Laboratory: UL CCS SAR Lab B Date: 7/6/2012

CDMA BC1(Secondary Antenna)

Frequency: 1880 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C

Medium parameters used: f = 1880 MHz; σ = 1.521 mho/m; εr = 51.862; ρ = 1000 kg/m3

DASY5 Configuration:

- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1259; Calibrated: 2/13/2012 - Probe: EX3DV4 - SN3686; ConvF(7.04, 7.04, 7.04); Calibrated: 2/16/2012; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1120

Edge 4/1xEVDO Rel.0_ch 600/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm

Maximum value of SAR (measured) = 0.209 mW/g

Edge 4/1xEVDO Rel.0_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 11.985 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 0.284 mW/g SAR(1 g) = 0.170 mW/g; SAR(10 g) = 0.096 mW/g Maximum value of SAR (measured) = 0.217 mW/g

Edge 4/1xEVDO Rel.0_ch 600/Zoom Scan 2 (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,

dz=5mm Reference Value = 11.985 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 0.216 mW/g SAR(1 g) = 0.132 mW/g; SAR(10 g) = 0.076 mW/g Maximum value of SAR (measured) = 0.169 mW/g

0 dB = 0.169 mW/g = -15.44 dB mW/g