Download - calculo brazo hidraulico

Transcript
Page 1: calculo brazo hidraulico

MOTORES BRAZO MECANICO

MOTOR GRIP0.07 A12 V320 RPM

P=ViP=12 V 0.07 AP=0.84 Watts1W=1.341x10-3hp= 0.001126 hp

MOTOR BANDA0.05 A20 V100 RPM

P=ViP=20 V 0.05 AP=1 Watts1W=1.341x10-3hp= 0.001341hp

Page 2: calculo brazo hidraulico

MOTOR GRANDE1.25 A5 V16.5 RPM

P=ViP=5 V 1.25 AP=6.25 Watts1W=1.341x10-3hp= 0.00838125 hp

MOTOR V1.00 A12 V42.85 RPM

P=ViP=12 V 1.00 AP=12 Watts1W=1.341x10-3hp= 0.016092 hp

MOTOR P0.3 A

Page 3: calculo brazo hidraulico

12 V42 RPM

P=ViP=12 V 0.3 AP=3.6 Watts1W=1.341x10-3hp= 0.0048276 hp

CABLE

Cable = T 0.84 lb

MOTOR DEL CABLE. (MOTOR V)

T =23.659 N·m 42.8 RPM 0.016092 Hp

Eje ¼”

0.0004023 Hp 42.8 RPM x 2 =268.92 rad/min

Page 4: calculo brazo hidraulico

W= 4.48 rad/segOp=0.25XP=1.57” 1.12in/seg0.0015in/s

0.001126 Hp0.03Hp11.88 RpmRelación 27=1

0.81 2.223

FUERZA GRIP

Page 5: calculo brazo hidraulico

T=7.24 N·m=0.00337432 HpV=wr w= rad seg 1 RPM = 2 rad Relación de Catarina

1.64 a 42 RPM Nota: La velocidad aumenta pero se disminuye el torque.

Page 6: calculo brazo hidraulico

PUNTO B0.036155 – 1= 0.036158 kg F F(d) 0.48X0.014472EstáticamenteFuerza Máxima a 0º o 180º

TORQUE DE LOS EJESEje motor P = T = 7.24 N·m

ESFUERZO DE CORTE DEL MOTOR P

Page 7: calculo brazo hidraulico

T motor = 32.00018RPM = 16.5 RPMHps = 0.005866875 HpHp = fv

TORQUE DEL PUNTO X

Motor T= 32.00018 Relación de CatarinasTR = 50.24 1.57 a 1

Page 8: calculo brazo hidraulico

FUERZAS DE CORTE DEL PUNTO X

Page 9: calculo brazo hidraulico

TORQUE CON REDUCCIONES DE LA BASE