Ultrasonic level meter for Oil Tank.pdf

9
ͻͲ Ultrasonic Level Sensors US&UE Series Explore Proof & Standard Ultrasonic Level Sensors (mA, RS485, Relay/Alarm) Characters: High stability and reliability Precise linear and temperature compensation ZERO and SPAN calibrate available Explore structure and design Smaller blind zone All English menu and operate Safety, Aesthetics, High degree of protection Applicable for various liquids, powder and solid Low failure rate, easy to install, easy to maintain ùÐÃ Ž : Water tank level measurement Food tank level measurement Seal water level measurement Powder and Solid level application Sewage and industry wastewater treatment Oil and Fuel level measurement Hazardous zone level measurement Oil tanker, small fuel tank level measurement Other distance and level application And so on Pro les: explore proof ultrasonic level sensors have beautiful appearance, stability performance; explore proof design and good measurement function. Isolated power supply by industrial instruments, all of the output, input lines with lightning protection, overvoltage, over current protection circuit functions. Transmitter function of small, weak energy, high sensitivity, bearing small; a complete sensor system can accurately complete the objects in different environments continuous non-contact measurement; small blind, high accuracy, wide application, send and receive integrated, which can accurately receive weak echo signals to ensure the accuracy and reliability. proof Ultrasonic Level Sensor is a safe, clean, high precision, long life, stable and reliable, easy installation and maintenance ease of use easy to read and so on.

Transcript of Ultrasonic level meter for Oil Tank.pdf

  • Ultrasonic Level Sensors

    US&UE Series

    Explore Proof & Standard Ultrasonic Level Sensors (mA, RS485, Relay/Alarm)

    Characters:

    High stability and reliability

    Precise linear and temperature compensation

    ZERO and SPAN calibrate available

    Explore structure and design

    Smaller blind zone

    All English menu and operate

    Safety, Aesthetics, High degree of protection

    Applicable for various liquids, powder and solid

    Low failure rate, easy to install, easy to maintain

    :

    Water tank level measurementFood tank level measurement

    Seal water level measurement

    Powder and Solid level application

    Sewage and industry wastewater treatment

    Oil and Fuel level measurement

    Hazardous zone level measurement

    Oil tanker, small fuel tank level measurement

    Other distance and level applicationAnd so on

    Pro les:

    explore proof ultrasonic level sensors have beautiful appearance, stability performance; explore proof

    design and good measurement function. Isolated power supply by industrial instruments, all of the output, input lines

    with lightning protection, overvoltage, over current protection circuit functions. Transmitter function of small, weak

    energy, high sensitivity, bearing small; a complete sensor system can accurately complete the objects in different

    environments continuous non-contact measurement; small blind, high accuracy, wide application, send and receive

    integrated, which can accurately receive weak echo signals to ensure the accuracy and reliability.

    proof Ultrasonic Level Sensor is a safe, clean, high precision, long life, stable and reliable, easy installation and

    maintenance ease of use easy to read and so on.

  • Ultrasonic Level Sensors

    US&UE Series

    ^

    Model:Parameter:

    Explore Proof Type

    UE2000/UE8000/UE9000

    Standard Non-Explore Proof Type

    US8000/US8000-E/US9000

    Measuring Range: 0- Optional

    2 wires output: Max range is 15 meters

    4 wires output: Max range is 50 meters (Integrative Type)

    and 70 meters (Segregated Type)

    Accuracy:

    (Linearity Hysteresis

    Repeatability)

    5%F.S

    %F.S

    Including non-lin., rep. and hys.

    Optional

    Blind Zone: 15 cm to 60cm

    Working pressure: 5 Bar 2 Bar

    Working Temp: Sensor: -20 ~+80 ; Meter: - -20 ~+60

    Store Request:

    Temperature: -20~+80

    Pressure: atmospheric pressure

    Others Non-corrosive gases (optional corrosion probe) or steam, no vibration.

    Temperature Compensation: -20 ~60

    Medium compatible: Non-Contact application suitable for all kinds of medium

    Corrosive environment will using anti-corrosive type sensor

    Output: 4~

    4~ resistance (4 wire)

    1~5 V (3 wires)

    0~5 V (3 wires)

    0~10 V (3 wires)

    RS485 Relay/Alarm

    Power Supply: 12 ~ 24 V DC ( 120 mA)

    Resolution: 3 mm or 0.1%F.S.

    Zero Temp. Drift: Typical: 0.05%FS/ Max: 0.1%FS/

    FS Temp. Drift: Typical: 0.05%FS/ Max: 0.1%FS/

    Electronic connection: Terminal Box

    Display Units: LCD Screen for display data of measuring and programme.

    Relay /Alarm Output:

    Alarm for high and low level

    Or State programmable (optional for 4 wire)

    AC 250V/ 8A;

    DC 30V/ 5A;

    Certificate approving: Exia IICT6

    Water Proof: Sensor: IP68; Meter: IP65

    Weight: Net weight is about 5KG, Full Packing weight is about 6KG (Not Include Cable)

    Remarks: Special applications request by Customized

  • Ultrasonic Level Sensors

    US&UE Series

    Dimension Drawings:

    Probe TypeSize

    Probe A Probe BRange: 6m Range:6m-15m

    A M60.0 2.5 M72.0 2.5

    B 55 67

    C M60.0 2.5 M72.0 2.5

    D 120 120

    E 11 11

    F Circumference 104

    Uniform three-hole 9

    Circumference 104

    Uniform three-hole 9

    H1 50 65

    H2 30 30

    H3 36 36

  • Ultrasonic Level Sensors

    US&UE Series

    D ^ d

    Model Ultrasonic Level Sensors/MetersUE2000 Integrative Explore Proof Type (2 wires: max 15 meters, 4 wires: max 50 meters)UE8000 Integrative Explore Proof Type --- (2 wires: max 15 meters)

    UE9000 Segregated Explore Proof Type --- (max 70 meters)

    US8000-E Economic Type--- (Max 12 Meters Range)US8000 Integrative Standard Type --- (max 50 meters)US9000 Segregated Standard Type --- (max 70 meters)

    Range code Range (meters) Ref. Range code Range (meters) Ref.

    01 G/S 11 G/S

    02 G/S 12 G/S

    03 G/S 13 G/S

    04 G/S 14 G/S

    05 G/S 15 G/S

    06 G/S 16 G/S

    07 G/S 17 G/S

    08 G/S 18 G/S

    09 G/S 19 G/S

    10 G/S 20 By Customized G/S

    Code Probe Dimension (mm)

    A M60*2.5 male thread (Range 6 m)

    B M72*2.5 male thread (Range 6 m)

    C By Customized (probe type check datasheet)

    Code Working Pressure

    2 2 Bar (standard type)

    5 5 Bar (explore proof type)

    Code W

    1 M60x2.5 male 4

    2 M72*2.5 male 5 Flange

    3 6 By Customized

    Code Signal Output

    E5 4-20 mA (2 wires)

    E6 0-5V (4 wires)

    E50 4-20 mA (4 wires)

    E11 RS485

    Code Power Supply

    S3 24 V DC

    S5 12 V DC

    S13 220 VAC 15% 50Hz

    Code Accuracy

    1 5%F.S

    2 %F.S

    HPT621 17 B 0 2 E5 S8 1 Remarks

  • Ultrasonic Level Sensors

    UE3000 Series

    UE3000 Series Small-scale Ultrasonic Level Sensors

    UE3000-ES UE3000-DS BS Series CS Series

    Pro les:

    UE3000 Ultrasonic Level Transmitter is developed

    based on 30 years of experience in industrial

    measurement and control specifically for low-cost,

    small installation space. It combines ultrasonic sensors,

    temperature sensors, ultrasonic servo circuit,

    transmission circuit and uses SMD components

    and ASIC which is developed together with

    the United States partner. All these features realize

    a concise and smart level transmitter.

    All gold-plated circuit boards, internal electromagnetic

    shielding and software digital filter are tested for (industrial)

    48 hour under high and low temperature aging.

    It promises higher and long-term reliability.

    Shell is made of solid texture and good

    NLEPF acoustic characteristics of synthetic material.

    The body is shape sophisticated aesthetics, waterproof,

    dustproof, and can adapt to the most of working

    conditions on site. On liquid cans, the walls,

    the BS ultrasonic transmitter.

    There is no need of such tools as gongs nails,

    D

    A very quick and easy installation, maintenance can be realized.

  • Ultrasonic Level Sensors

    UE3000 Series

    ^ Measuring Range 1m 2m 10m (custom, another exercise price please)

    Blind Area:Detection accuracy : 0.5 ~ 0.25% FS (at blind-fold drive away, 25 )

    Output: Voltage: 1 ~ 5V/ 0~5V

    current: 4 ~ 20mA/ 0 ~ 20mA

    serial port: RS485/ RS232

    Operating Temperature 0 ~ +50 (default); -10 ~ +80 (custom, another exercise price please)

    Protection class IP65 (default); IP68 (custom, another exercise price please)

    / D

    Wave beam Angle

    Measuring mode Value-added measurement E=0 Measured output correspond to D values

    D-value measurement E= Actual installation height

    Measured output correspond to H values.

    (According to user requirements, the factory Settings, as shown in the diagram)

    Double nut clamp on fixed installation

    E---The total face height of container to the sensor, that is the

    Blind Area actual installation height;

    D--- The height of the sensor to the surfaces of level.

    H---that is the actual level height

    LevelMax range

    ^ :1) Measuring range and Requirements of blind zone.

    2) Media type to be measured (Liquid or solid, such as: Water, sewage, mud, gasoline, diesel oil, toluene, sulfur

    dioxide, ore, coal, cement, soybeans, wheat, corn, flour,etc.)

    If it is liquid: Is there liquid steam, mist, foam, wave, stirring, floating objects;

    If it is solid: Is there a dust, granular or powder media is.

    3) The minimum ~ maximum temperature and pressure of media.

    4) Corrosion of media. If it is placed inside the jar, the jar needs to know the material, and if there is corrosion of the

    lining.

    5) The need for anti-corrosion, explosion-proof, to split or an integrated one.

    6) Working environment: exposure to the pond, cover the pond, lying tank, vertical tank, tank, pot is through

    atmospheric pressure and so on.

    7) Power Supply: 24VDC or 220VAC, 12VDC power supply can be customized.

    8) Output:4-20mA or RS485,or need to relay output?

  • Ultrasonic Level Sensors

    UE3000 Series

    h > d ^ '

    BS-------

  • Ultrasonic Level Sensors

    UE3000 Series

    Dimension Drawings:

    BS/CS

    UE3000-DS

    M20X1.25

    80

    UE3000-ES

    M66X20

  • / Holykell Trade Office

    Holykell Technology Company LimitedTel: +86-731-89873265/+86-731-89975645

    Fax: +86-731-89873646

    E-mail: [email protected]

    Website1:http://www.holykell.com

    Website2:http://holykell.en.alibaba.com

    Website3:http://www.globalsources.com/holykell.co

    Address: No. 8 Lu Tian Road, Lugu High-Tech Development Zone, Changsha City, China.

    HOLYKELL OVERSEA MARKETING CENTRE TEAM:

    Kenneth Huy (Ken)

    Kenneth Huy (General Manager)

    E-mail: [email protected] TEL: +86-731-89873265 FAX: +86-731-89873646

    Trade Manager ID: holykell MSN ID: [email protected]

    Skype ID: kenneth.huy Mobile Number: +8613875928016

    Jennifer Lee (Jennifer)

    Jennifer Lee (Sales Manager)E-mail: [email protected] TEL: +86-731-89975645

    Trade Manager ID: cn1000328227

    Vicky Fu (Vicky)

    Vicky Fu (Sales Engineer)E-mail: [email protected] TEL: +86-731-89975636

    Trade Manager ID: ali1000143006

    Barry Liu (Barry)

    Barry Liu (Sales Engineer)E-mail: [email protected] TEL: +86-731-89975636

    Trade Manager ID: cn1001059439