Time performance of the large dynamic range SiPM Sen QIAN ( )On Behalf of the PMT Lab Institute of High Energy Physics, Chinese Academy of Science [email protected] 26th. Nov. 2019

Transcript of Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is...

Page 1: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

Time performance of the large dynamic range SiPM

Sen QIAN ( 钱森 ),On Behalf of the PMT Lab

Institute of High Energy Physics, Chinese Academy of Science

[email protected] 26th. Nov. 2019

Page 2: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

Outline

➢ I. The Motivation;

➢ II. The Performance of the SiPM Prototypes;

➢ III. How to improve the timing characterisitc of SiPM;

➢ IV. Summary;

2

Page 3: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

K/π discrimination at 10GeV/c needs at least 35ps time resolution.

To achieve positive identification of the Kaons up to p~10Gev/c, need to aim for

10-15 ps time resolution per track;

The time resolution of the TOF detector should be a precision of 70ps ~ 30

detected photons.

The Photon Senser? from Hamamastu?BINP? Photek?

MCP-PMT? FPMT? SiPM?…

1.1 Motivation----LHCb - TORCH 3

—The TORCH (Time Of internally Reflected CHerenkov light)

—R&D project –to develop a large-area time-of-flight system for the LHCb Upgrade II.

“The Status of the TORCH time of flight project” @Neville Harnew @ RICH 2018

Page 4: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ

measurements.

Combining the dE/dx and ToF (~50 ps for each particle) measurements leads to an

efficient distinguish between different hadrons.

K/p discrimination efficiency can be improved by 10% with a 50ps time resolution

TOF detector.

The Photon Senser? from Hamamastu?BINP? Photek?

MCP-PMT? FPMT? SiPM?…

1.2 Motivation----CEPC - TOF 4

—The CEPC Circular Electron Positron Collider

— R&D project of the ECAL, HCAL and other detector.

Page 5: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

SiPM Multi-MCP-PMT LAPPD

Product SenSL J30035 Photek MAPMT253 ANL+InCOM

QE@400nmPDE: 47%

~20% 20%

CE >90% 100%

Pixel size 35*35μm2 0.48*0.48 mm2 Position resolution <1mm

Operating voltage 26.7V 3500V < 2500V

Gain E6 E6 E7

Dark counts ~50KHz/mm2 <3Hz/mm2 1 Hz/mm2

Rise time@SPE < 1ns --> ~200ps ~200ps ~400ps

TTS@SPE(σ) <1ns --> ~60ps ~40ps ~50ps

Magnetic field Good normal normal

Cost Cheap Expensive Expensive

1.3 The Fast Timing Detectors 5

Page 6: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

Outline

➢ I. The Motivation;

➢ II. The Performance of the SiPM Prototypes;

➢ III. How to improve the timing characterisitc of SiPM;

➢ IV. Summary;

6

Page 7: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

S12571-010C C30035 11-3030C-E

Company Hamamatsu SenSL NDL

Effective Active Area 1mm*1mm 3mm*3mm 3mm*3mm

Effective Pitch 10μm 35μm 10μm

Pixel Number 10 K 5 K 90 K

Recommended

Temperature25℃ 21℃ 20℃

Operation Voltage 69.5V -27V 32.5V

Gain 5E5 3E6 2E5

PDE@420nm 10%(+4.5V) 41%(+5V) 31%(+5V)

2.1 The SiPM Prototypes for Test 7

Page 8: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

TDC: 35ps@ LSB

The ps leaser: 45ps jet

The sigma of facility :25ps

HDO9000 / HDO9000-MS High Definition OscilloscopesSigma@Osc=23.4 ps

2.2 The TTS test Facility in the PMT-Lab 8

Page 9: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

2.3 The performance of SiPM(1)--S12571-010C

[email protected]. : 242.3±1.3 ps@σ

3p.e.

MPE spectrum Waveform

RT@72mV=1.4ns

1.35ns 25ps

The rise time is about 1.35 ns when the number of p.e is more than 60.

The Limitation TTS is about 25ps when this SiPM generating big signals.

9

Page 10: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

2.3 The performance of SiPM(2)—SenSL C30035

F out waveform S out waveformBiasing and readout circuit D

[email protected]

=600psRT@34mV

=178ps

Rise Time TTS

170ps 11ps

There is no amplifier when measuring the C30035, thus p.e is represented by amplitude.

As the amplitude increases, the rise time and TTS become smaller. The Limitation TTS is about

11ps when the RT of the signal is about 170ps.

10

Page 11: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

Ref: D. Han, Y. Peng, K. Liang, R. Yang. NDL SiPMs and its potential applications, 2019.

2.3 The performance of SiPM(3)—NDL 11-3030C-E

• Small micro cell, high micro cell density --> large dynamic range( >20K p.e.)• The time resolution of the SiPM changes with overvoltage.

AmplifierReadout board

N D L

(Novel Device Laboratory,Beijing)

Tel: +86-10-62207419

Email: [email protected],

http://www.ndl-sipm.net/device.html

11

Page 12: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

Amp=2.2mV(10p.e),RT=3.4nsTTS(Sigma)[email protected]

NDL SiPM was tested without using its own amplifier.

Amp=102mV(500p.e),RT=1.46nsTTS(Sigma)=14.6ps@102mV

Amplitude/mV RT/ns TTS/ps

2.2 3.4 273.5

6.8 1.8 57.3

24.8 1.54 30.2

48.6 1.44 18.3

80.5 1.47 16.9

102 1.46 14.6

150.8 1.45 15.6

The rise time is 1.45 ns,TTS is 14.6 ps when SiPM with larger signals. As the amplitude increases, the trend of rise time and TTS is consistent.

12

Page 13: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

S12571-010C C30035 11-3030C-E

Temperature in the Lab 27℃ 27℃ 27℃

Electronic Board

Waveform

Limitation Rise Time 1.35 ns 0.17 ns 1.45 ns

Operation Voltage 69.5V -27V 32.5V

TTS@SPE by Company 106ps - 85.1ps

TTS@Sigma

242 ps@3pe 118 [email protected] 273 ps@10pe

43 ps@30pe 51 [email protected] 30 ps@120pe

24 ps@200pe 11 [email protected] 15 ps@500pe

2.4 The Timing Characteristics of the SiPM Prototypes 13

Page 14: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

Outline

➢ I. The Motivation;

➢ II. The Performance of the SiPM Prototypes;

➢ III. How to improve the timing characterisitc of SiPM;

➢ IV. Summary;

14

Page 15: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

For the SiPM Prototype:

----the Low Voltage for Operation: Energy Resolution VS Time Resolution;

----the Threshold for DAQ: Noise? Trigger Mode? ……

----the Temperature: Gain/ Dark Noice VS Temperature? ……

----the Electromagnetic shielding: Noise? ……

----the Excitation source: Photon?Gamma?Electron?Neutron? ……

----the Others? ……

For the Electronic:

----the Low Voltage Power Supply: the Noise? the Ripple? ……

----the Amplifier : the Noise? the Impedance? ……

----Temperature compensation:How to keep the same gain in different temperature?

By adjusting the voltage or by the data correction?

----the DAQ system : TDC VS FADC? the Impedance? ……

3.0 How to Improve the Timing of the SiPM 15

Page 16: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

3.1 The R&D of a new Electronic Board in the PMT-Lab

Version 1 Version 2 Version 3

Version 1, in 2017: The Power module has been able to provide stable voltage from 20V to

90V for SIPM, Achieve Low Noise and good Energy Resolution.

Version 2, in 2018: Due to the interface selection of RS422-USB serial port, this type of

Board can be connected to Multiple-Modules together in parallel for unified control.

Version 3, in 2019: By improving the design and Electronic components, the quality of

the signal from the SiPM is good for better Enerngy Resolution and Time Resolution.

The Electronic Board: LV power supply + Amplifier +Temperature compensation module

16

Page 17: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

Modules △Mean 1 p.e. ER 2 p.e. ER 3 p.e. ER

Hamamatsu 37.76 13.32% 13.03% 15.17%

Self-developed 35.01 14.45% 14.32% 16.44%

17*ER= Energy resolution

3.2 The Performance of the Electronic Board for the same MPPC (1)

Hamamatsu EB.V3

17

Page 18: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

18

3.2 The Performance of the Electronic Board for the same MPPC (2)

3# EB.V2 in signle mode

3# EB.V2

Address △Mean1 △Mean2 △Mean3 1P.E 2P.E 3P.E

3# EB.V2Single-Board 43.50 45.40 45.30 15.70% 16.70% 16.82%

Multi-Boards 42.90 45.50 45.60 17.48% 18.22% 19.91%

3# EB.V2

3# EB.V2 in Multi- mode

18

Page 19: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

3.3 The Timing Characteristic of the same MPPC (1)

Hamamatsu

3# EB.V3

S12571-025C

19

Page 20: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

TTS: 65.62 ± 0.33 ps

TTS

@

11 p.e.

RT

@

11p.e.

The RT and TTS of EB.V3 module test is better than the one of Hamamatsu.

TTS: 313.9 ± 1.2 ps

RT: 1.59 ± 0.33ns RT 1.19 ± 0.06ns

3.3 The Timing Characteristic of the same MPPC (2)

Hamamatsu EB.V3

20

Page 21: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

3.4 The LV / Thr. of the MPPC for better Timing 21

Photoelectrons= 9p.e.

Temperature=27℃

S12571-010C

With the Electronic Board

by Hamamatsu

Operating voltage:70V;

Overvoltage: 5V;

Threshold: 10%-90% of the Amplitude

Best Threshold: 50%

Threshold: 50% of the Amplitude

Operating voltage 68V~74V;

Overvoltage 3V~9V;

Best Overvoltage: 5V ~ 65ps

Page 22: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

IV. Summary

1. Some SiPMs could have the better time resolution about 20ps with large

photons, as better as the FPMTs; but the TTS@SPE is really difficutly to test

for the large DR.

2. In our Lab, we have already designed a special Electrinic Board for the

SiPM, with LV power supply, Amplifier , Temperature Compensation

module together, and also could be connected to multiple modules together

in parallel for unified control.

3. With this special type of Electrinic Board, the time characteristics (RT, TTS)

of the same SiPM could be improved a lot.

4. The Over Voltage, the Threshold, et.al could also affected the Energy

Resloution and Time Resolution of the SiPM,

22

Page 23: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

Thanks for your attention!

Page 24: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps
Page 25: Time performance of the large dynamic range SiPM€¦ · SiPM dynamic range up to 10000 p.e. is needed for a ECAL for H → γγ measurements. Combining the dE/dx and ToF (~50 ps

The performance of SiPM—SenSL C30035

The microcell structure schematic has a capacitively coupled output. The fast output is

formed from the sum of all microcells.

Sout----standard output

Fout----fast output