TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

24
TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD

Transcript of TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Page 1: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

TED Thermomechanical AnalysesEsposito Raffaele EN-STI-TCD

Page 2: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

TED core

Cu-BeInsert

(C17200)

Cu-OFEAl (6082 T6)Graphite (R7500)

Beam type: LHC-Standard (25 ns)Particle energy: 450 GeVProtons per bunch: 1.2e11Bunches per pulse: 288Protons per pulse: 3.456e13Bunch period: 25 nsPulse time: 7.2 μsPulse period: 21.6 sEnergy per pulse: 2.492 MJAverage power: 115.4 kW

Page 3: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Graphite – Steady State Thermal Analysis

Max. Temperature: 109.23 °C

Page 4: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Graphite – Transient Thermal Analysis

Max. Temp.: 631.19 °C

Page 5: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Graphite – Transient Structural AnalysisMax. Compressive Principal Stress: 38.11 MPa

Page 6: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Graphite – Transient Structural Analysis

Max. Tensile Principal Stress: 6.6671 MPa

Page 7: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Graphite – Transient Structural AnalysisMax. Von Mises Equivalent Stress: 21.235 MPa

Page 8: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Aluminum – Steady State Thermal Analysis

Max. Temperature: 87.596 °C

Page 9: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Aluminum – Transient Thermal Analysis

Max. Temperature: 131.29 °C

Page 10: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Aluminum – Transient Structural Analysis

Max. Compressive Principal Stress: 280.98 MPa

Page 11: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Aluminum – Transient Structural Analysis

Max. Tensile Principal Stress: 137.52 MPa

Page 12: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Aluminum – Transient Structural Analysis

Max. Von Mises Equivalent Stress: 134.09 MPa

Page 13: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Cu-Be – Steady State Thermal AnalysisMax. Temperature: 176.19 °C

Page 14: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Cu-Be – Transient Thermal AnalysisMax. Temperature: 147.96 °C

Page 15: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Cu-Be – Transient Structural Analysis

Max. CompressivePrincipal Stress:

505.89 MPa

Page 16: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Cu-Be – Transient Structural AnalysisMax. Tensile Principal Stress: 113.31 MPa

Page 17: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Cu-Be – Transient Structural AnalysisMax. Von Mises Equivalent Stress: 283.73 MPa

Page 18: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Copper – Steady State Thermal Analysis

Max. Temperature: 72.879 °C

Page 19: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Copper – Transient Thermal Analysis

Max. Temperature: 49.398 °C

Page 20: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Copper – Transient Structural AnalysisMax. Compressive Principal Stress: 179.12 MPa

Page 21: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Copper – Transient Structural AnalysisMax. Tensile Principal Stress: 103.68 MPa

Page 22: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Copper – Transient Structural AnalysisMax. Von Mises Equivalent Stress: 138.7 MPa

Page 23: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Summary

Material Graphite Aluminum Cu-Be Copper

Max. Temp. [°C] 631.19* 131.29 176.19 72.879

Min. Princ. [MPa] 38.11 280.98* 505.89* 179.12*

Compr. Strength 105.68 192 (Y) – 224 510 (Y) – 580 200 (Y) – 240

Max. Princ. [MPa] 6.6671 137.52 113.31 103.68

Max. V. M. [MPa] 21.235 134.09 283.73 138.7

Tensile Strength 26.4 192 (Y) – 224 510 (Y) – 580 200 (Y) – 240

*We shouldn’t have oxidation problems since the graphite stays beyond 400 °C for only 8 milliseconds per pulse

*Stresses with a strong hydrostatic component

Page 24: TED Thermomechanical Analyses Esposito Raffaele EN-STI-TCD.

Thank you for your attention