Page 1: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

ATeaching plan

A1

Page 2: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

ACINV MAIN

M

DRIVEWAY

C S

TROOF MOUNTED CONDUIT (TYP.)

μ

RS

SHEET INDEX

PV0.0 COVER AND SITE PLAN

PV1.0 GENERAL NOTES

PV2.0 ARRAY LAYOUT

PV3.0 LINE DIAGRAM

PV4.0 LABELS

PHOTOVOLTAIC SYSTEM1 2 3 4 51

####

C

B

A

C

B

A

REV #:DESIGNED BY:

CUSTOMER INFORMATION:

DATE:

12/1/16

SYSTEM SIZE:

AC / DC kW STC: 2.687kW \ 3kW

EQUIPMENT:

PV MODULES: (10) LG LG300N1K-G4

INVERTER(S): (1) ABB PVI-3.0-OUTD-S-US-A

SCOPE OF WORK:

INSTALLATION OF A SAFE AND CODE-COMPLIANT GRID-TIED SOLAR PV SYSTEM ON AN EXISTING RESIDENTIAL ROOF TOP. APPLICABLE CODES:

CONTRACTOR INFORMATION:

JURISDICTIONAL INFORMATION:

NOTES TO INSTALLER:

2016 CEC (BASED ON 2014 NEC)2016 CBC2016 CRC2016 CPC2016 CMC2016 CFCLOCAL AMENDMENTS TO CA CODES

FOR INSTALLER USE ONLY

POST INSTALL SUNEYES REQUIRED?

I CERTIFY THAT NO CHANGES HAVEBEEN MADE TO THE ARRAY LAYOUT:

PV- 0.00

NO

N

STRUCTURAL UPGRADES

FENCE

SD

PV METERPVMROOF OBSTRUCTION

UTILITY METER

AC DISCONNECTAC

MONITORING UNIT

JUNCTION BOXMT

DRIVEWAY

RAPID SHUTDOWN ROOFBOX

RS

KEY:

CONDUIT RUNPROPERTY LINE

SUBPANEL

DC DISCONNECT

INVERTER

MAIN SERVICE PANELM

SUB

DC

INV

MAIN

SOLAR MODULE μ

FIRE CLEARANCE

JB

SCALE : SITE PLAN

N.T.S.

1. ALL WORK MUST COMPLY WITH THE REQUIREMENTSOF THE LATEST EDITION OF THE CALIFORNIA BUILDINGCODE AND THE CALIFORNIA ELECTRICAL CODE(ARTICLES 690 AND 705 FOR PV).2. ALL ROOF PENETRATIONS ARE REQUIRED TO BEFLASHED. ALL TILE ROOFS ARE REQUIRED TO BEDOUBLE-FLASHED.3. ROOF DECK FLASHING IS REQUIRED TO BEINSPECTED PRIOR TO PANEL INSTALLATION.4. CONTRACTOR IS REQUIRED TO HOLD A CURRENTAND VALID C-10 OR C-46 LICENSE.5. DESIGNED TO 110MPH 3-SECOND PEAK GUST.

ANYTOWN, CITY OF5555 C STREETANYTOWN, CA 99999

PV INSTALLER8888 B STREETANYTOWN, CA 99999

CUSTOMER NAME4444 C STREETANYTOWN, CA 99999

A2

Page 3: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

GENERAL NOTES:1 2 3 4 51

####

C

B

A

C

B

A

REV #:DESIGNED BY:

CUSTOMER INFORMATION:

DATE:

12/1/161.0PV-

0

GENERAL NOTES:

N1. DRAWINGS ARE DIAGRAMMATIC ONLY. THE LOCATION AND ROUTING OF RACEWAYS SHALL BE DETERMINED BY THE CONTRACTOR UNLESS OTHERWISE NOTED OR STANDARDIZED.

N2. IF A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT, WIRE, EQUIPMENT DEVICES, OVERCURRENT PROTECTION, GROUNDING SYSTEMS, ETC. (ALL EQUIPMENT AND MATERIALS) THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIALS AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO ENSURE COMPLETE COMPLIANCE WITH ALL CODES AND TO ENSURE THE LONGEVITY AND SAFETY OF THE OPERABLE SYSTEM.

N3. ALL OUTDOOR EQUIPMENT SHALL BE MIN. NEMA 3R RATED.

N4. METAL CONDUIT AND ENCLOSURES SHALL BE USED WHERE PV SOURCE OR OUTPUT CIRCUITS ARE RUN INSIDE A BUILDING.

N5. MODULES SHALL NOT BE PLACED OVER ANY PLUMBING VENTS AND AT LEAST 6" ABOVE FLUSH VENTS.

N6. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ANY AND ALL REQUIREMENTS GIVEN BY UTILITY COMPANIES.

N7. FOR ADDITIONAL EQUIPMENT SPECIFICATIONS, SEE PROVIDED CUT SHEETS.

N8. ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC REFERENCES.

N9. IT IS ILLEGAL FOR ANYONE UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFFESIONAL ENGINEER OR REGISTERED ARCHITECT TO ALTER ANY ITEMS ON THIS PLAN.

N10. THE ENGINEER HAS NOT BEEN RETAINED FOR JOB SUPERVISION.

N11. ALL OSHA REGULATIONS AND STANDARDS FOR SAFE AND HEALTHFUL WORKING CONDITIONS TO BE FOLLOWED.

N12. ALL CONTRACTORS WORKING ON ROOFS TO BE INSURED AS SUCH.

STRUCTURAL NOTES:

S1. MOUNTS ARE DIAGRAMMATIC AND EXACT LOCATION MAY CHANGE, BUT SHALL BE ACCURATELY SPACED.

S2. MOUNTS SHALL BE STAGGERED WHEN NECESSARY TO EVENLY DISTRIBUTE LOAD AMONGST RAFTERS.

S3. DO NOT SPLICE RAILS IN MIDDLE 50% OF SPAN BETWEEN TWO MOUNTS.

ELECTRICAL NOTES:

E1. MAXIMUM VOLTAGE DOES NOT EXCEED 600VDC, AND DC EQUIPMENT SHALL BE RATED FOR AT LEAST 600VDC.

E2. ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION SHALL BE NEW AND LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY.

E3. AN INVERTER IN AN INTERACTIVE SOLAR PV SYSTEM SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED.

E4. ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION BY INVERTER)(S), AND ARC FAULT PROTECTION IS INVERTER-INTEGRATED.

E5. ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT CALCULATED AT THAT COMPONENT.

E6. ALL MODULES AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL BE PROPERLY BONDED AND GROUNDED.

E7. ALL WIRE, VOLTAGES, AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION.

E8. ONLY COPPER (CU) CONDUCTORS SHALL BE USED FOR NEW WIRING. CONDUCTORS SHALL BE STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS.

E9. ALL MODULES AND RACKING SHALL BE GROUNDED VIA UL2703-LISTED RACKING SYSTEM'S INTEGRATED GROUNDING (PLEASE SEE DATA SHEET) OR WITH TIN PLATED DIRECT BURIAL RATED LAY IN LUGS USING STAINLESS STEEL HARDWARE, STAR WASHERS, AND THREAD FORMING BOLTS.

CUSTOMER NAME4444 C STREETANYTOWN, CA 99999

A3

Page 4: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

3'

16'-7"

3'10

'-10"

3'

2X8 NOMINAL, 24 O.C.

COMPOSITE SHINGLE5" X 5/16" - LAG

2.5" MIN. EMBEDMENT PER SCREW

QMSE-LAG SHINGLE

L-FOOT

IRONRIDGE XR10

SOLAR MODULE

1 2 3 4 51##

##

C

B

A

C

B

A

REV #:DESIGNED BY:

CUSTOMER INFORMATION:

DATE:

12/1/162.0PV-

0

STRUCTURAL UPGRADES

FIRE CLEARANCE

ATTIC VENT

PLUMBING OR ATTIC VENT

CHIMNEY

SKYLIGHT

SOLAR MODULE

SYMBOL KEY:

ROOF

RAFTERS

RAIL

MOUNT

STRING CONFIG.# #

NOTE:MODULES SHALL NOT BE GREATER THAN 8 INCHES ABOVE ROOF COVERING

MODULE SPECIFICATIONS(10) LG LG300N1K-G4MODULE WEIGHT: 37.48MODULE LENGTH: 64.57MODULE WIDTH: 39.37

SCALE : 1 ARRAY LAYOUT3/16" = 1'-0"

SCALE : 2 MOUNTING DETAILNTS

RAFTER SIZE:RAFTER SPAN:RAFTER SPACING:ROOF MATERIAL:

2X8 NOMINAL10' - 7"

24"COMPOSITE SHINGLE

ROOF 1 SPECS

NUMBER OF MODULES:TOTAL MOD. WEIGHT (lbs):RACKING WEIGHT (lbs):ARRAY WEIGHT (lbs):ARRAY AREA (sqft):ARRAY DEAD LOAD (lbs/sqft):NUMBER OF MOUNTS:LOAD PER MOUNT(lbs):ARRAY AZIMUTH(°)ARRAY TILT(°)NUMBER OF FLOORS

10374.8

58432.8176.5

2.522

19.7

231

ARRAY 1 SPECS

180

CUSTOMER NAME4444 C STREETANYTOWN, CA 99999

A4

Page 5: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

- +10 MODULES1 STRING OF

(2) #10 PV-Wire(1) #10 EGCFREE AIR

DC ~ AC

INVERTER

__

MPPT 1

OUTPUTEGC

(N) INVERTER W/ INTEGRATED DC DISCONNECTS

PVI-3.0-OUTD-S-US-A

(3) #10 THWN-2(1) #10 EGC1/2" EMT

METERLOCUS

(3) #10 THWN-2(1) #10 EGC1/2" EMT

LINELOAD

AC DISCONNECT, 30AMP,

NON-FUSIBLE, C-H DG221URB

(3) #10 THWN-2(1) #10 EGC1/2" EMT

METER

(E) LOADS

240V 2P 3-W 1F

(E) LOADS

20A 2P

100A MAIN BREAKER

(E) 100A Cutler Hammer MSP(N) ABB RS2-2PN6RAPID SHUTDOWN BOX

PS

RAPID SHUTDOWN

(2) #10 THWN-2(1) #10 EGC1/2" EMT

1 2 3 4 51##

##

C

B

A

C

B

A

REV #:DESIGNED BY:

CUSTOMER INFORMATION:

DATE:

12/1/163.0PV-

DESIGN CONDITIONSHIGHEST 2% DB DESIGN TEMP (°C): 37MIN. MEAN EXTREME ANNUAL DB (°C): -3

0

BREAKERSWITCHSCREW TERMINALFUSE

ELECTRICAL KEY:

SPLICEEARTH GROUNDCHASSIS GROUNDGECEGC

MODULE ELECTRICAL SPECIFICATIONS(10) LG LG300N1K-G4SHORT CIRCUIT CURRENT (lsc): 9.7OPEN CIRCUIT VOLTAGE (Voc): 39.7OPERATING CURRENT (IMP): 9.26OPERATING VOLTAGE (VMP): 32.5MAX SERIES FUSE RATING: 20STC RATING: 300PTC RATING: 279.9

RATED WATTS (EACH):AC OPERATING VOLTAGE (V):AC OPERATING CURRENT (A):NUMBER OF MPPT CHANNELSINVERTER EFFICIENCY:

3300

14.5

0.96

240

ABB PVI-3.0-OUTD-S-US-AINVERTER 1 SPECIFICATIONS

2

INTEGRATED DC DISCONNECT

MAXPOWER POINT CURRENT (Imp):MAX POWER POINT VOLTAGE (Vmp):MAX SYSTEM VOLTAGE (Voc):SOURCE CIRCUIT CURRENT (Isc):MAX SHORT CIRCUIT CURRENT (Isc):

9.332542812.112.1

INVERTER 1 MPPT SPECIFICATIONS

MAX Voc = 10 x [39.7V + (39.7V x -0.0028 x (-3°C - 25°C))] = 428VDCImax = 9.7A x 1 STRING x 1.25 = 12.125A

100 x 1.2 = 120(120 - 100(MCB)) / 125% = 16AMAX ALLOWABLE INV. OUTPUT CURRENT RATING = 16A

CONTINUOUS USE = Imax * 1.25 = 15.16ACONDITIONS OF USE = Imax / Tcorr / Cfill

= 12.1A/0.71/1 = 17.04ACONDUCTOR SIZE FOR 17.04AINSTALLATION SHALL USE MIN. #10 AWG

CONDUIT ELEVATION: 1/2 TO 3-1/2" = 22 °CHIGH AMBIENT TEMPERATURE: 37 °CEXTREME LOW: -3°CROOFTOP AMBIENT TEMP (Tcorr): 59°C = 0.71CONDUIT FILL (Cfill): 1

10 MODULES TOTAL10 x 279.9(PTC WATTS) x 0.96 = 2687 CEC WATTS

PVI-3.0-OUTD-S-US-A MAX OUTPUT CURRENT = 14.5ABREAKER SIZE = 14.5A x 1.25 = 18.125A –» 20A

CUSTOMER NAME4444 C STREETANYTOWN, CA 99999

A5

Page 6: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS

TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN

POSITION

NEC 690.17(E)PLACE THIS LABEL ON ALL DISCONNECTING

MEANS WHERE ENERGIZED IN AN OPEN POSITION

WARNING

PHOTOVOLTAIC POWER SOURCE

NEC 690.31 (E) 3 & 4; 2012 IFC 605.11.1PLACE ON ALL JUNCTION BOXES, EXPOSED RACEWAYS EVERY 10' AND 1' FROM BENDS

AND PENETRATIONS, ADJACENT TO THE MAIN SERVICE DISCONNECT

WARNINGWARNING

NEC 690.5(c)PLACE THIS LABEL ON INVERTER(S) OR NEAR

GROUND-FAULT INDICATOR (ON INVERTER(S) U.O.N.)

ELECTRIC SHOCK HAZARDIF A GROUND FAULT IS INDICATED,

NORMALLY GROUNDED CONDUCTORSMAY BE UNGROUNDED AND ENERGIZED

1 2 3 4 51##

##

C

B

A

C

B

A

REV #:DESIGNED BY:

CUSTOMER INFORMATION:

DATE:

12/1/164.0PV-

INTERACTIVE PHOTOVOLTAIC POWER SOURCE

RATED AC OUTPUT CURRENT (A): 14.5

NOMINAL OPERATING AC VOLTAGE (V): 240

WARNING

NEC 690.35(F) PLACE THIS LABEL AT EACH JUNCTION BOX, COMBINER BOX,

DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE:

ELECTRIC SHOCK HAZARDTHE DC CONDUCTORS OF THIS

PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED

NEC 690.56(c)PLACE ON RAPID SHUT DOWN DISCONNECT WHEN RAPID SHUT

DOWN IS INSTALLED

PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN

0

NOTE:BACKGROUND AND LETTERING COLORS FOR SIGNAGE/LABELS SHALL COMPLY WITH (IN ORDER OF PRIORITY) AHJ & FIRE DEPARTMENT AMENDMENTS, STATE CODE, AND ANSI GUIDELINES. THIS PAGE IS INTENDED FOR SIGNAGE/LABEL VERBIAGE ONLY.

NEC 705.12(D)(2)(b)PLACE THIS LABEL AT P.O.C. TO SERVICE

DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL (AND SUBPANEL IF APPLICABLE))

INVERTER OUTPUT CONNECTIONDO NOT RELOCATE THIS OVERCURRENT DEVICE

WARNING

CONTAINS MULTIPLE POWER SOURCES

NEC 705.12(D)(3)PLACE LABEL ON ALL EQUIPMENT CONTAINING

OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE

SOURCES.

CAUTION

PHOTOVOLTAIC SYSTEM DISCONNECT

RATED MAX POWER POINT CURRENT (Imp):

RATED MAX POWER POINT VOLTAGE (Vmp):

MAX SYSTEM VOLTAGE (Voc):

MAX CIRCUIT CURRENT (Isc):

9.3

428

12.1

325

INVERTER 1 MPPT DC DISCONNECT

CUSTOMER NAME4444 C STREETANYTOWN, CA 99999

A6

Page 7: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

ACINV MAIN

M

μ

RS

N

LOCATION OFINVERTERS WITHINTEGRATED DCDISCONNECT

LOCATION OF MAINSERVICE ENTRANCEAND UTILITY METER

DRIVEWAY

POWER TO THIS BUILDING IS SUPPLIED FROM THE FOLLOWING SOURCES WITH

DISCONNECTS LOCATED AS SHOWN

DIRECTORY LABEL PER NEC 705.10

1 2 3 4 51##

##

C

B

A

C

B

A

REV #:DESIGNED BY:

CUSTOMER INFORMATION:

DATE:

12/1/165.0PV-

0

CUSTOMER NAME4444 C STREETANYTOWN, CA 99999

A7

Page 8: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

LG300N1K-G4

60 cellLG’s new module, LG NeON™ 2 Black, adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires to enhance power output and reliability. LG NeON™ 2 Black demonstrates LG’s efforts to increase

warranty, durability, performance under real environment, and aesthetic design suitable for roofs.

Enhanced Performance WarrantyLG NeON™ 2 Black has an enhanced performance warranty. The annual degradation has fallen from -0.7%/yr to -0.6%/yr. Even after 25 years, the cell guarantees 2.4%p more output than the previous LG NeON™ modules.

High Power OutputCompared with previous models, the LG NeON™ 2 Black

Aesthetic RoofLG NeON™ 2 Black has been designed with aesthetics in mind; thinner wires that appear all black at a distance. The product may increase the value of a property with its modern design.

Double-Sided Cell StructureThe rear of the cell used in LG NeON™ 2 Black will contribute

from the rear of the module is reabsorbed to generate a great amount of additional power.

Better Performance on a Sunny DayLG NeON™ 2 Black now performs better on sunny days

Outstanding DurabilityWith its newly reinforced frame design, LG has extended the warranty of the LG NeON™ 2 Black for an additional 2 years. Additionally, LG NeON™ 2 Black can endure a front load up to 6000 Pa, and a rear load up to 5400 Pa.

About LG Electronics

Innovation fora Better Life

LG Electronics is a global player who has been committed to expanding its capacity, based on solar energy business as its future growth engine. We embarked on a solar energy source research program in 1985,supported by LG Group’s rich experience in semi-conductor, LCD, st Mono X® series to the market in 2010, which were exported to 32 countries inthe following 2 years, thereafter. In 2013, NeON™ (previously known as Mono X® NeON) & 2015 NeON2 with CELLO technology won “Intersolar Award”, which proved LG is the leader of innovation in theindustry.

Dimensions (mm/in)

North America Solar Business TeamLG Electronics U.S.A. Inc1000 Sylvan Ave, Englewood Cliffs, NJ 07632

Contact: [email protected]

DS-N2-60-K-G-F-EN-50427

Copyright © 2016 LG Electronics. All rights reserved.01/01/2016

* The distance between the center of the mounting/grounding holes.

Electrical Properties (NOCT*)

Module TypeMaximum Power (Pmax)MPP Voltage (Vmpp)MPP Current (Impp)Open Circuit Voltage (Voc)Short Circuit Current (Isc)

300 W222

30.1

7.38

36.9

7.81* NOCT (Nominal Operating Cell Temperature): Irradiance 800 W/m2, ambient temperature 20 °C, wind speed 1 m/s

Electrical Properties (STC *)

Module TypeMPP Voltage (Vmpp)MPP Current (Impp)Open Circuit Voltage (Voc)Short Circuit Current (Isc)

Operating Temperature (°C)Maximum System Voltage (V) Maximum Series Fuse Rating (A)Power Tolerance (%)

-40 ~ +90

1000 (IEC/UL)

20

0 ~ +3

300 W32.5

9.26

39.7

9.70

18.3

* STC (Standard Test Condition): Irradiance 1000 W/m², Module Temperature 25 °C, AM 1.5* The nameplate power output is measured and determined by LG Electronics at its sole and absolute discretion.

LG300N1K-G4

Innovation for a Better Life

Detail X Detail Y Detail Z Long side frame

7.5

/ 0.3

0

4.0

/ 0.1

6

5.5 / 0.22

R1.5 / R0.06

4.0 / 0.16Ø8.2 / Ø0.32

10.0 / 0.39

29.0 / 1.14

40.0

/ 1.

57

10.0 / 0.39

29.0 / 1.14

40.0

/ 1.

57

Short side frame

40 / 1.57

270

/ 0.6

3

170

/ 6.6

9

105

/ 4.1

3

(Z view)Ø8.2 / Ø0.32Mounting holes(8ea)

(X view)5.5 x 4.0 / 0.22 x 0.16

Drain holes(4ea)

Ø4.3 / Ø0.17

Grounding holes(12ea)

1000 / 39.37

(Distance between mounting holes)

(Size of short side)

1640

/ 64

.57

(Siz

e of

long

sid

e)

960 / 37.80

1100

/ 4

3.31

Junction box

1000 / 39.37Cable length

(Dis

tanc

e be

twee

n m

ount

ing

hole

s)

1300

/ 52

.18

(Dis

tanc

e be

twee

n m

ount

ing

hole

s)

Drain holes(4ea)

(Y view)4.0 x 7.5 / 0.16 x 0.30Characteristic Curves

Mechanical Properties

CellsCell Vendor Cell Type Cell Dimensions # of BusbarDimensions (L x W x H)

Front LoadRear LoadWeightConnector TypeJunction BoxLength of Cables Glass Frame

6 x 10

LG

Monocrystalline / N-type

156.75 x 156.75 mm / 6 inches

12 (Multi Wire Busbar)

1640 x 1000 x 40 mm64.57 x 39.37 x 1.57 inch

6000 Pa / 125 psf

5400 Pa / 113 psf

17.0 ± 0.5 kg / 37.48 ± 1.1 lbs

MC4, MC4 Compatible, IP67

IP67 with 3 Bypass Diodes

2 x 1000 mm / 2 x 39.37 inch

High Transmission Tempered Glass

Anodized Aluminum

Temperature Characteristics

NOCTPmppVocIsc

45 ± 3 °C

-0.38 %/°C

-0.28 %/°C

0.03 %/°C

Module Fire Performance (USA)Fire Rating (for CANADA)Product WarrantyOutput Warranty of Pmax

IEC 61215, IEC 61730-1/-2

IEC 62716 (Ammonia Test)

IEC 61701 (Salt Mist Corrosion Test)

ISO 9001

UL 1703

Type 2 (UL 1703)

Class C (ULC/ORD C1703)

12 years

Linear warranty** 1) 1st year: 98%, 2) After 2nd year: 0.6%p annual degradation, 3) 83.6% for 25 years

Curr

ent

(A)

Isc,

Voc

, Pm

ax (%

)

Voltage (V)

Temperature (°C)

10.001000W

600W

200W

800W

400W

6.00

2.00

8.00

4.00

0.00 10.00 30.0020.00 40.0015.00 35.0025.00 45.005.00

Isc

Voc

Pmax

140

60

100

20

120

40

80

0-40 900 25-25 50 75

A8

Page 9: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

7

Mechanical Installation

Module Mounting

solar modules is contingent upon modules being mounted in accordance with the requirements described in this section.

considered to comply with the requirements of UL 1703 unless the module with hardware that has been tested and evaluated with the module under this standard or by a field inspection certifying that the installed module complies with the requirements of UL 1703.

Site ConsiderationLGE solar modules should be mounted in a location that meets the following requirements.Operating Temperature

Design Strength

75lb/ft2. (Mounting by using frame bolts holes)

Excluded Operating Environments

operated in a location where they could come in direct contact with salt water or ammonia.

Mounting MethodsGeneral Information

sunlight exposure.

that the front/top glass faces downward in order to prevent water from entering the junction box, which could cause a safety hazard.

Clearance between the solar module frames and structures such as roofs or ground is required to prevent wiring damage and to allow air to circulate behind the solar module. The recommended standoff height is a minimum of 100mm.

mounted over a fire-resistant roof covering rated for the application. The fire resistance of the solar module is class C after ANSI/UL790.

class rating.

its factory frame is fully intact.

authorized and qualified individual

the solar module and reduce the strength of the frame.

frames to avoid tension from thermal expansion.

mounted in the manner specified in the mechanical mounting instructions.

The module is considered to be in compliance with UL1703 only when the module in mounted in the manner specified by the mounting instructions below.

mounted with racking and mounting products certified and listed for system fire class rating in accordance with UL1703 edition 2014 and UL2703 edition 2014.

for fire safety guidelines and requirements for any building or structure on to which the panels will be installed.

recommended to be taken an appropriate countermeasure to prevent possible damages to the lower side frame by slipping snow. (A snow guard should be installed in accordance with the manufacturer’s instructions.)

Solar module

Roof

Supporting part

A9

Page 10: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

Solar inverters

ABB string invertersPVI-3.0/3.6/3.8/4.2-TL-OUTD 3.0kW to 4.2kW

This family of single-phase string

inverters complements the typical

number of rooftop solar panels

enabling homeowners to get the most

efficient energy harvesting for the size

of the property.

This inverter offers a dual input

section that processes two strings

with independent Multiple Power Point

Tracking (MPPT).

This is especially useful for rooftop

installations with two different

orientations from two sub-arrays

oriented in different directions, or

unbalanced strings (for example: East

and West).

The dual-input sections with

independent MPPT enable a more

optimal energy harvesting condition.

The high-speed MPPT offers real-

time power tracking and improved

energy harvesting.

The flat efficiency curve ensures high-

efficiency at all output levels allowing

a consistent and stable performance

across the entire input voltage and

output power range.

The transformerless operation gives the

highest efficiency of up to 97.0 percent.

The wide input voltage range makes

the inverter suitable to low-power

installations with reduced string size.

This rugged, outdoor inverter has

been designed to be a completely

sealed unit, to withstand the harshest

environmental conditions.

Highlights:

Single-phase and three-phase output

grid connection

Wide input-voltage range for

increased stringing flexibility and

energy harvesting

The high-speed and precise MPPT

algorithm offers real-time power

tracking and improved energy

harvesting

Outdoor NEMA 4X rated enclosure

for unrestricted use under any

environmental conditions

Integrated DC disconnect switch

in compliance with international

Standards (-S Version)

2 ABB solar inverters | Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD

Technical data and typesType code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US

General specifications

Nominal output power 3000W 3600W3300

W3800W 4200W

Maximum output power wattage3000

W 33001

W33001

W3600

W40001

W40001

W3300

W42001

W42001

W4200

W46001

W46001

WRated grid AC voltage 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277VInput side (DC)Number of independent MPPT channels 2 2 2 2Maximum usable power for each channel 2000W 3000W 3000W 3000WAbsolute maximum voltage (Vmax) 600VStart-up voltage (Vstart) 200V (adj. 120-350V)Full power MPPT voltage range 160-530V 120-530V 140-530V 140-530VOperating MPPT voltage range Maximum current (Idcmax) for both MPPT in parallel

20A 32A 32A 32A

Maximum usable current per channel 10A 16A 16A 16AMaximum short circuit current limit per channel

12.5A 20.0A 20.0A 20.0A

Number of wire landing terminals per channel 2 pairsArray wiring termination Terminal block, pressure clamp, AWG20-AWG6Output side (AC)

Grid connection type1Ø/ 2W

Split- Ø/3W

1Ø/ 2W

1Ø/ 2W

Split- Ø/3W

1Ø/ 2W

1Ø/ 2W

Split- Ø/3W

1Ø/ 2W

1Ø/ 2W

Split- Ø/3W

1Ø/ 2W

Adjustable voltage range (Vmin-Vmax) (V)183- 228V

211- 264V

244- 304V

183- 228V

211- 264V

244- 304V

183- 228V

211- 264V

244- 304V

183-228V

211- 264V

244- 304V

Grid frequency 60HzAdjustable grid frequency range 57-60.5Hz

Maximum current (Iac,max) 14.5A 14.5A 12.0A 17.2A 16.0A 16.0A 16.0A 16.0A 16.0A 20.0A 20.0A 20.0A

Power factor > 0.995 (adjustable to ±0.8)Total harmonic distortion at rated power < 2%Grid wiring termination type Terminal block, Pressure clamp, AWG20-AWG6Input protection devicesReverse polarity protection YesOver-voltage protection type Varistor, 2 for each channelPV array ground fault detection Pre start-up R

ISO and dynamic GFDI (requires floating arrays)

Output protection devicesAnti-islanding protection Meets UL1741 / IEEE1547 requirementsOver-voltage protection type Varistor, 2 (L1 - L2 / L1 - G)Maximum AC OCPD rating 20A 20A 15A 25A 20A 20A 20A 20A 20A 25A 25A 25AEfficiencyMaximum efficiency 96.9% 97% 97% 97%CEC efficiency 96%Operating performanceNighttime consumption < 0.6W

RMS

Stand-by consumption < 8WRMS

CommunicationUser-interface 16 characters x 2 lines LCD displayRemote monitoring (1xRS485 incl.) VSN700 Data Logger (opt.), VSN300 Wifi Logger Card (opt.)EnvironmentalAmbient air operating temperature range -13°F to +140°F (-25°C to 60°C) with derating above 122°F (50°C)Ambient air storage temperature range -40°F to +176°F (-40°C to +80°C)Relative humidity 0-100% RH condensingAcoustic noise emission level < 50 db (A) @1mMaximum operating altitude without derating 6560ft (2000m)1. Capability enabled at nominal AC voltage and with sufficient DC power available.

Additional highlights- RS-485 communication interface

(for connection to laptop or datalogger)

- Available with the optional VSN300i ogger ard for ea and

a ordable wirele monitoring- ompliant with N 0 when

u ed with A Rapid Shutdowndevice

- ome tandard with Arc aultircuit nterruptor (A ) to compl

with N 0

A10

Page 11: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD | ABB solar inverters 3

Block diagram of PVI-3.0/3.6/3.8/4.2-TL-OUTD

Technical data and typesType code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US

Mechanical specificationsEnclosure rating NEMA 4XCooling Natural convectionDimensions H x W x D 33.8 x 12.8 x 8.7in (859 x 325 x 222mm)2

Weight <47.3lb (21.3kg)2

Shipping weight < 60lb (27.0kg)2

Mounting system Wall bracket

Conduit connections2

Trade size KOs (2ea x 1/2”) and (2ea x 1-1/4”, 3 places side, front, rear) Side: (2) plugged 3/4” openings, (2) Concentric KOs 3/4”, 1”

Back: (4) Concentric EKOs 3/4”, 1”DC switch rating (per contact) (A/V) 25/600Safety and ComplianceIsolation level Transformerless (floating array)

Safety and EMC standardUL1741, IEEE1547, IEEE1547.1, CSA-C22.2 N. 107.1-01, UL1998 UL 1699B, FCC Part

15 Class BSafety approval cCSAus

Regional Compliance Rule 21, HECO, NEC 2014 690.11, NEC 690.12 with ABB Rapid Shutdown deviceAvailable modelsWith DC switch, wiring box, arc fault detector and interrupter

PVI-3.0-OUTD-S-US-A

PVI-3.6-OUTD-S-US-A

PVI-3.8-OUTD-S-US-A

PVI-4.2-OUTD-S-US-A

2. When equipped with optional DC switch and wiring box.All data is subject to change without notice

IN1

IN2

+

-

+

-

-S VERSION

IN1

+

-

IN2

+

-

MPPT 2(DC/DC)

MPPT 1(DC/DC) BULK CAPS

INVERTER(DC/AC) LINE

FILTERGRID PARALLEL

RELAY

L1

L2

PE

RESIDUAL CURRENTDETECTION

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

μP

CONTROL CIRCUIT

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL*

+ R

- R

ALARM

N.C

N.O

C

GROUNDFAULT

DETECTION

N

* Remote control function not available on -A version

IN1

IN2

+

-

+

-

DCAFDI

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN1

IN2

+

-

+

-

IN2.1(+)

IN2.2(+)

IN2.1(-)

IN2.2(-)

STANDARD VERSION

IN1

IN2

+

-

+

-

-A VERSION

IN1

IN2

+

-

+

-

5,00%

10,00%

15,00%

20,00%

25,00%

30,00%

35,00%

40,00%

45,00%

50,00%

55,00%

60,00%

65,00%

70,00%

75,00%

80,00%

85,00%

90,00%

95,00%

100,00%

215 250 300 345 400 480

[%]

of

Ra

ted

Po

we

r

MPPT Voltage [V]

97,0

96,6

96

94,8

94,4

95,2

94

93,6

93,2

92,8

92,4

92

91,6

95,6

97,0

96,4

96,4

96

95,2

96

95,2

96,2

96

94 94

92 92

92

91

92

93

94

95

96

97

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

y, %

200 Vdc

340 Vdc

480 Vdc

PVI-4.2-OUTD-US PVI-4.2-OUTD-US

FF0 002

DQD 507 Rev. 2012-05-22 Page 1

Certificate of Compliance Certificate: 2708406 Master Contract: 259813

Project: 2722409 Date Issued: April 24, 2014

Issued to: ABB, Inc. 16250 W. Glendale Drive New Berlin, WI 53151 USA

The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent

indicator 'US' for US only or without either indicator for Canada only.

Issued by: Jocelyn Jens Product Group Coordinator

Authorized by: Lindsay Clark Operations Manager

PRODUCTS

CLASS 5311 09 - POWER SUPPLIES - Distributed Generation Power Systems Equipment CLASS 5311 89 - POWER SUPPLIES - Distributed Generation - Power Systems Equipment

- Certified to U.S. Standards

Utility Interactive Inverter, Models PVI-4.2-OUTD-US, PVI-3.8-OUTD-US, PVI-3.6-OUTD-US, PVI-3.0-OUTD-US, PVI-4.2-OUTD-S-US, PVI-3.8-OUTD-S-US, PVI-3.6-OUTD-S-US, PVI-3.0-OUTD-S-US, PVI-4.2-OUTD-S-US-A, PVI-3.8-OUTD-S-US-A, PVI-3.6-OUTD-S-US-A, PVI-3.0-OUTD-S-US-A, PVI-4.2-OUTD-US-W, PVI-3.8-OUTD-US-W, PVI-3.6-OUTD-US-W and PVI-3.0-OUTD-US-W; provided with two DC input channels, permanently connected, system ratings as follows:

Notes: 1. All above models in this series may include expansion board with wireless antennae option and will be

identified with model designation including “–Z” suffix.2. For details related to rating, size, configuration, etc. reference should be made to the CSA Certification

Record or the Certificate of Compliance Annex A.

A11

Page 12: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

2 ABB solar inverters | Product flyer for RSD

Type code 2-String pass-through 2-String combined 4-String combined

PV source conductor input

Max input current (per string) 11.25A

Max input voltage 600VNumber of input strings 2 2 4Conductor size 14-8 AWGPV output conductors outputNumber of output circuits 2 1 2Conductor size 12-6 AWGDC disconnect N/A Yes YesControl powerPower consumption <5W, 24V/0.2A <2.5W, 24V/0.1A <5W, 24V/0.2AMaximum power conductor size 12 AWGE-stop button OptionalEnvironmentalMounting angle 0-90°Dimensions H x W x D 10.54“x8.54“x5.32“ (without mounting bracket)Weight 6lb 5.8lb 6.2lbOperating temperature range -25°C to +70°CEnclosure rating NEMA 4XCertifications UL1741:2010, FCC Part 15 Class BWarrantyStandard warranty 10 YearsAvailable modelsRapid shutdown kit RS2-2PN6-kit RS2-1CN6-kit RS4-2CN6-kitRapid shutdown rooftop box for 2-box system N/A RS2-1CN6 N/AOptional emergency stop 1SFA611821R1026Information in this document is subject to change without notice

< 10 ft.

+24V RSD power PV systemdisconnect

Utilitygrid

~

Rooftop 1

Rooftop 2

PV String 1

PV String 2

PV String 3

PV String 4

ABB rapidshutdown

PV output MPPT1

PV output MPPT2

ABB rapidshutdown

Rapid shutdown wiring diagram: 2-RSD system

Technical data and types

Two RS2-1CN6 boxes may be powered by one power supply. For PV systems requiring two RSD boxes order the

RS2-1CN6- kit and one RS2-1CN6 box.

Product flyer for RSD | ABB solar inverters 3

InverterDC disconnect

PV outputpositive

Rapid shutdown box Inverter / inverter switch-box

PV outputnegative

Outputterminalblocks

Controlpowersupply

IN 1+and 2+

Dischargecircuit

Localdisconnecting

means

Customer ACdisconnect

AC grid

RS2-1CN6 two strings in, one PV output

IN 1-and 2-

Inverter

DC disconnectRapid shutdown box Inverter / inverter switch-box

Outputterminalblocks

Controlpowersupply

In 1+and 2+

Dischargecircuit

Localdisconnecting means

Customer ACdisconnect

AC grid

RS4-2CN6 four strings in, two PV outputs

PV output 1positive

PV output 1negative

PV output 2positive

PV output 2negative

Outputterminalblocks

In 1-and 2-

In 3-and 4-

In 3-and 4-

Inverter

DC disconnectRapid shutdown box Inverter / inverter switch-box

Outputterminalblocks

Controlpowersupply

In 1+

In 1-

In 1+Discharge

circuit Customer ACdisconnect

AC grid

RS2-2PN6 two strings in, two strings out

Outputterminalblocks

PV string1positive

PV string 1negative

PV string 2positive

PV string 2negative

In 1-

In 2+

In 2-

Block diagram for rapid shut down models

This 2-string model combines the strings to one PV output circuit. The RS2-1CN6 includes a disconnect switch on the

front cover to disconnect the PV output conductors from the equipment down stream. Auxillary terminals are provided for

connecting an emergency stop button, if desired.

This 4-string model combines 2-strings together in two separate PV output circuits. The RS4-2CN6 includes a disconnect

switch on the front cover to disconnect the PV output conductors from the equipment downstream. Auxillary terminals are

provided for connecting an emergency stop button, if desired.

The RS2-2PN6 is a 2-string pass-through with no string combining and no local disconnecting means included. Auxillary

terminals are provided for connecting an emergency stop button, if desired.

A12

Page 13: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

Certificate A .. ®

TUVRheinland

_ce_rt

_ifi

_,ca

_te

_n

_o_. -----11 CU 72150214 01 . \ · t--1---------------

License Holder: Power-One 3201 East Harbour Drive Phoenix AZ 85034 USA

Test report no.: USA-ZZ 31580190 001

Tested to: UL 1741:2010

Manufacturing Plant: ABB Inc. 16250 W Glendale Drive New Berlin WI 53151 USA

Client Reference: Bob White

CSA C22.2.107.l-01 (R2006)

Certified Product: Rapid Shut Down Device License Fee - Units

Model Designation: 1) RS4-2CN6, 2) RS2-2PN6, 3) RS2-1CN6 (trademark: ABB)

Rated Voltage: Rated Current: Protection Class: Max. Short-Circuit

DC 90-580V lOA max. (per channel) I Current (input/output): 1) ,3)

2) 11.25/22.5A 22. SA

contd. Special Remarks: To be installed according to the licensee's installation instructions. Also evaluated to NFPA 70: 2014, Article 690.12.

Appendix: 1, 1-6

Licensed Test mark:

I TUVRheinland

I

C - us

7

7

Date of Issue (day/mo/yr) 13/04/2015

TUV Rhelnland of Nonh America, Inc., 12 Commerce Road, Newtown, CT 06470, Tel (203) 426-0888 Fax (203) 426-4009

Certificate ---------i CU, 721502.14 02 Certificate no.

I

License Holder: Power-One 3201 East Harbour Drive Phoenix AZ 85034 USA

Manufacturing Plant: ABB Inc. 16250 W Glendale Drive New Berlin WI 53151 USA

Test report no.: USA-ZZ 31580190 001 Client Reference: Bob White

Tested to: UL 1741:2010 CSA C22.2.107.l-01 (R2006)

Certified Product: Rapid Shut Down Device

contd.

Output Current:

Rated Ambient Temperature: Enclosure Index:

Licensed Test mark:

1) 20A max. (per channel)2) 1 OA max. (per channe 1)

3) 20A max.-25 ° C to +7o 0 cType 4X

A.. ® TUVRheinland

License Fee - Units

Date of Issue (day/mo/yr) 13/04/2015

TUV Rhelnland of North America, Inc., 12 Commerce Road, Newtown, CT 06470, Tel (203) 426-0888 Fax (203) 426-4009

A13

Page 14: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

Tech Brief

The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge XR Rails. All system types that feature the UFO family—Flush Mount, Tilt Mount and Ground Mount—are fully listed to the UL 2703 standard.

UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations.

UFO Family of Components

The UFO securely bonds solar modules to XR Rails. It comes assembled and lubricated, and

he gore

The UFO securely bRails. It comes asse

The Stopper Sleeve snaps onto the UFO, converting it into a bonded end clamp.

Each Bonded Splice uses self-drilling screws to form a secure connection. No bonding strap needed.

The bonding bolt attaches and bonds the L-foot to the rail. It is installed with the same socket as the rest of the system.

A single Grounding Lug connects an entire row of PV modules to the grounding conductor.

Each Bonded Splice uses lf d illi f

The IronRidge Flush Mount, Tilt Mount, and Ground Mount Systems have been listed to UL 2703 by Intertek Group plc.

UL 2703 is the standard for evaluating solar mounting systems. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments.

Tech Brief

XR Rails XR1000 Only

UFO/Stopper

Bonded Splice N/A

Grounding Lugs 1 per Row 1 per Row 1 per Array

Microinverters & Power

Optimizers

Enphase - M250-72, M250-60, M215-60, C250-72Darfon - MIG240, MIG300, G320, G640

SolarEdge - P300, P320, P400, P405, P600, P700, P730

Fire Rating Class A Class A N/A

ModulesTested or Evaluated with over 400 Framed Modules

Refer to installation manuals for a detailed list.

Approved Enphase microinverters can provide equipment grounding of IronRidge systems, eliminating the need for

same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details.

A14

Page 15: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

FLUSH MOUNT INSTALLATION MANUAL - 2© 2016 IRONRIDGE, INC. VERSION 1.20

RATINGS

MARKINGS

#5003288

#5004376

#5003320

UL 2703 LISTED

••••

CLASS A SYSTEM FIRE RATING PER UL 1703

• Any module-to-roof gap is permitted, with no perimeter guarding required. This rating is applicable with any third-partyattachment.

STRUCTURAL CERTIFICATION

FLUSH MOUNT INSTALLATION MANUAL - 9© 2016 IRONRIDGE, INC. VERSION 1.20

MODULE COMPATIBILITY

MAKE MODELS

Astronergy Solar

Canadian Solar

ET Solar

GigaWatt Solar

Hanwha Solarcan be blank or B.

Hyundai

Itek

Panasonic

Phono Solar

Prism Solar

REC Solar

RenesolaAbv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, or Db-b.

Renogy

Silfab

SolarWorld

Stion

SunEdison

Suniva

Sunpower

Sunpreme

Suntech

Trina

Winaico

A15

Page 16: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

5224 South 39th Street, Phoenix, Arizona 85040 tel: (602) 438-2500 fax: (602) 438-2505 ROC#291316 www.smleng.com

Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers

IronRidge December 18, 2014 1495 Zephyr Ave Page 1 of 20 Hayward, CA 94544

Attn: Mr. David F. Taggart, Vice President Products

Subject: IronRidge XR10 Rail, Roof Flush Mounting System – Structural Analysis

Dear Sir:

We have analyzed the IronRidge XR10 Rail for the subject solar module support system and determined that, for the configurations and criteria described below, it is in compliance with the applicable sections of the following Reference Documents:

Codes: ASCE/SEI 7-10 Min. Design Loads for Buildings & Other Structures California Building Code 2012 Edition

Other: AC428, Acceptance Criteria for Modular Framing Systems Used to Support PV Modules, dated Effective November 1, 2012 by ICC-ES Aluminum Design Manual, 2010 Edition

The IronRidge XR10 Rail is an extruded aluminum section with an overall depth of 1.75 in. and a net area of 0.363 sq.in. The rails are used to support solar modules, typically, on the roof of a building. See Exhibit A – attached. The rails are clamped to aluminum angle brackets that are either attached directly to the roof framing or attached to a stand that is screwed to the roof framing. The rails are mounted across the slope with a small clearance (flush mounting) to the underlying roof structure. The installed solar modules are at the same slope as the underlying roof structure.

All loads are transferred to the roof framing through the angle brackets by simple bi-axial flexure of the rails. The maximum span of the rails is governed by either the mid-span flexural stresses or the deflection requirement that the rail not come into contact with the roof.

The effect of seismic loads (for all design categories A-F) have been determined to be less than the effect due to wind loads in all load conditions and combinations. Therefore, the maximum allowable spans for common load cases are shown in the tables below. Tables 1A-9A are for modules with a maximum long dimension of 67.5 inches and Tables 1B-9B are for modules with a maximum long dimension of 78.5 inches.

IronRidge December 18, 2014 Mr. David F. Taggart Page 5 of 20 IronRidge XR10 Rail, Roof Flush Mounting System – Structural Analysis

Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers

- 5 -

Table 4A MAXIMUM SPANS (in) Roof Slope 7° to 27° Wind Zone 1 (67.5" Max Module Length)XR10Rail

WindSpeed Ground Snow Load

Exposure mph 0 psf 10psf

20psf

30psf

40psf

50psf

60psf

70psf

80psf

90psf

Category B

100 75 65 55 49 43 39 35 33 31 29 105 75 65 55 49 43 39 35 33 31 29 110 75 65 55 49 43 39 35 33 31 29 120 75 65 55 49 43 39 35 33 31 29 130 75 65 55 49 43 39 35 33 31 29 140 71 65 55 49 43 39 35 33 31 29 150 66 65 55 49 43 39 35 33 31 29 160 62 62 54 48 43 39 35 33 31 29 170 59 59 53 47 43 39 35 33 31 29

Category C

100 75 65 55 49 43 39 35 33 31 29 105 75 65 55 49 43 39 35 33 31 29 110 75 65 55 49 43 39 35 33 31 29 120 70 65 55 49 43 39 35 33 31 29 130 65 64 54 48 43 39 35 33 31 29 140 60 60 53 48 43 39 35 33 31 29 150 56 56 52 47 43 39 35 33 31 29 160 53 53 51 46 42 39 35 33 31 29 170 50 50 50 45 41 38 35 33 31 29

Category D

100 75 65 55 49 43 39 35 33 31 29 105 73 65 55 49 43 39 35 33 31 29 110 70 65 55 49 43 39 35 33 31 29 120 64 64 54 48 43 39 35 33 31 29 130 60 60 53 47 43 39 35 33 31 29 140 55 55 52 46 42 39 35 33 31 29 150 52 52 50 46 42 39 35 33 31 29 160 49 49 49 45 41 38 35 33 31 29 170 46 46 46 44 40 37 35 33 31 29

Notes – see page 20

A16

Page 17: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

IronRidge December 18, 2014 Mr. David F. Taggart Page 6 of 20 IronRidge XR10 Rail, Roof Flush Mounting System – Structural Analysis

Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers

- 6 -

Table 5A MAXIMUM SPANS (in) Roof Slope 7° to 27° Wind Zone 2 (67.5" Max Module Length)

XR10Rail

WindSpeed Ground Snow Load

Exposure mph 0 psf 10psf

20psf

30psf

40psf

50psf

60psf

70psf

80psf

90psf

Category B

100 72 65 55 49 43 39 35 33 31 29 105 69 65 55 49 43 39 35 33 31 29 110 66 65 55 49 43 39 35 33 31 29 120 60 60 55 49 43 39 35 33 31 29 130 56 56 55 49 43 39 35 33 31 29 140 52 52 52 49 43 39 35 33 31 29 150 49 49 49 49 43 39 35 33 31 29 160 46 46 46 46 43 39 35 33 31 29 170 43 43 43 43 43 39 35 33 31 29

Category C

100 61 61 55 49 43 39 35 33 31 29 105 58 58 55 49 43 39 35 33 31 29 110 56 56 55 49 43 39 35 33 31 29 120 51 51 51 49 43 39 35 33 31 29 130 48 48 48 48 43 39 35 33 31 29 140 44 44 44 44 43 39 35 33 31 29 150 41 41 41 41 41 39 35 33 31 29 160 39 39 39 39 39 39 35 33 31 29 170 36 36 36 36 36 36 35 33 31 29

Category D

100 56 56 55 49 43 39 35 33 31 29 105 54 54 54 49 43 39 35 33 31 29 110 52 52 52 49 43 39 35 33 31 29 120 47 47 47 47 43 39 35 33 31 29 130 44 44 44 44 43 39 35 33 31 29 140 41 41 41 41 41 39 35 33 31 29 150 38 38 38 38 38 38 35 33 31 29 160 36 36 36 36 36 36 35 33 31 29 170 33 33 33 33 33 33 33 33 31 29

Notes – see page 20

IronRidge December 18, 2014 Mr. David F. Taggart Page 7 of 20 IronRidge XR10 Rail, Roof Flush Mounting System – Structural Analysis

Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers

- 7 -

Table 6A MAXIMUM SPANS (in) Roof Slope 7° to 27° Wind Zone 3 (67.5" Max Module Length)

XR10Rail

WindSpeed Ground Snow Load

Exposure mph 0 psf 10psf

20psf

30psf

40psf

50psf

60psf

70psf

80psf

90psf

Category B

100 59 59 55 49 43 39 35 33 31 29 105 56 56 55 49 43 39 35 33 31 29 110 54 54 54 49 43 39 35 33 31 29 120 49 49 49 49 43 39 35 33 31 29 130 46 46 46 46 43 39 35 33 31 29 140 42 42 42 42 42 39 35 33 31 29 150 40 40 40 40 40 39 35 33 31 29 160 37 37 37 37 37 37 35 33 31 29 170 35 35 35 35 35 35 35 33 31 29

Category C

100 50 50 50 49 43 39 35 33 31 29 105 48 48 48 48 43 39 35 33 31 29 110 45 45 45 45 43 39 35 33 31 29 120 42 42 42 42 42 39 35 33 31 29 130 39 39 39 39 39 39 35 33 31 29 140 36 36 36 36 36 36 35 33 31 29 150 33 33 33 33 33 33 33 33 31 29 160 31 31 31 31 31 31 31 31 31 29 170 29 29 29 29 29 29 29 29 29 29

Category D

100 46 46 46 46 43 39 35 33 31 29 105 44 44 44 44 43 39 35 33 31 29 110 42 42 42 42 42 39 35 33 31 29 120 38 38 38 38 38 38 35 33 31 29 130 35 35 35 35 35 35 35 33 31 29 140 33 33 33 33 33 33 33 33 31 29 150 31 31 31 31 31 31 31 31 31 29 160 29 29 29 29 29 29 29 29 29 29 170 27 27 27 27 27 27 27 27 27 27

Notes – see page 20

A17

Page 18: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

8431 Murphy Drive Middleton, WI 53562 USA

Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com

����������� �� �� � �����

����������� ��������� ��������������������� � ���������� ���������������������� � �� ���������� ��� ������� � �������� ������� ���� � ���������������� ������������� ��������� ��� �� ��� ������������� ������� ���������� ���� � ��������������������� �� �������� � �� ��� ���� �� �������� ���������������� �� ���������� ����������� �������������������������������� ��������� ���������� �����!���� �������� ������ ���"��� ������ �������������� ��� ������ ���������� ������#��������� ����� � ����������������� ��������� �������������� ������ ��� ��� �� ����� ���� ������ ������������� ��� ����������������� ��������� � ��������������� ��������� �� $������ �������� ������������� ���������� ������������� ������ �� ���������� �� ��$������ ���������������� �������� ����������� ������� �� � ����� ���� ������ �������������������������������������� � ����� ���� �����������

�GFT-OP-11a (24-MAR-2014)�

����������������� ���������� � ����� ������������������������ ��������������������� ˇˇ ˆˇ ˙ˆ ˝˛ ˇ˙ �������������

����������� �������������������������������� ���������������������������� ������������������������������������� ������� ������������ �������������������������������������������

������������� ������!� ° ������� ����!��ˇ˙ "#�$�%&' �() �!�* �' + � � �,( ��" ˙ #���-�(��

"�������#���������!� .��&�������'�����+��&�/�������!��

$���%� �"���������&����������!�

.���, ������������������������0.��&������1�'��������2!��,�����(�.���������3� �4�+����%���%%����������+&��������5'%��ˇ �˝�����6 ��������%&���)�������������!��,�����(�.���������3� �����%����%���%%����������+��&�5'%�ˇ �˝�����6 ��������%&���)�������������!��5������+ ��&���#7���%�1���������8��+�����&��8�������&��������3���������&����3���)����2 �%� ��&�����������&����'���������8�����������������'���%�����+���8'��&�����3���� �������������������������!�� ��%� ����� ����������� �9���!��5&��� ����������%%����8���+��&���'�° ��������� �6:��%� �'� ��3����&�!��

'����!� ° ��������.��&������+��&�/ ˜ �˜�����(�������!� ° ��������.��&������$�������)�����!� -4��;˛6 �1���������#!������ˇ# !62���������3����3��'����������'����� �����������) ���� �

,���%����������������) ���� �����< ����4���3� �-���+ ��&��.���0�������&���)������������������������ �.������������������=��!�˝> ��˛ ˇ #�$� �������%�-4ˇ;˛ 6�5&����������������� �)!�ˇ> �˝˛ ˇ ˙ �1��������6ˇ !̋ 2���������3����3��'�3��.���0�������&���)������������������������!�

*��� �����������%�+ ���!� ������?�5��������� ) ����� ( ����!�>˙ 6ˇ ��%&'���)����������� �@���#6#A��

#���� �,��!� ˛>ˆ ˝; ˆ˝˛ ˇ�����˛ 6ˆˇ ; ˆ˝˛ˇ #�,���$��������������!� ˇ ˛ˇ; A"6˙6 ���0��ˇ ˇ �ˇ˛ˇ ;A "6˙ 6�°̆ 0̨ ˛ˇ � ��˛ˇ" ˇ#" ;>���0˛˛ ��B �ˇ ˛ˇ" ""˙ "˝ ���0˛˛ˇ � ˇ 0� ˇ !�,������� �������������� ����� ���������������������������������������-�������������������,������������������������������������������������ ��������� � � � �

&�����������!� ,& ���$��8��&� $����������!� ,&��� �����,����!� 5��&�������°° �. ��������������� ,����!����������������� 5��&�������� �.���������������� � � �)�%�����!�������� � )�%�����!������ �#��!������������������� ˛#ˆ˝#ˆ ˝˛ˇA � #��!�� ˛#ˆ˝#ˆ ˝˛ˇA �

A18

Page 19: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

Sources: American Wood Council, NDS 2005, Table 11.2 A, 11.3.2 A

Notes: 1) Thread must be embedded in a rafter or other structural roof member. 2) See NDS Table 11.5.1C for required edge distances.

Lag pull-out (withdrawal) capacities (lbs) in typical lumber:

.50 798 266

.46 705

.46 705

212

.46 705

.55 921

.42 615 205

.50 798 266

E-Mount Lag QMSE - LAG

Sep-2014, Rev 1BI 7.2.3-31

1st course

3rd course

2nd course

You are now ready for the rack of your

choice. Follow all the directions of

the rack manufacturer as well as the

module manufacturer.

All roofi ng manufacturers’ written

instructions must also be followed

by anyone modifying a roof system.

Consult the roof manufacturer's specs

and instructions prior to touching

the roof.

Using drill with 7/32" bit, drill pilot hole into roof and rafter, taking care to drill square to the roof. Do not use mount as a drill guide. Drill should be ‘long style bit’, aka ‘aircraft extension bit’ to drill a 1¾ " deep hole into rafter.

Clean off any sawdust, and fi ll hole with sealant compatible with roofi ng materials.

Slide the fl ashing into position. Insert the rubber plug into the QBlock cavity.

Slide the washer and the L-foot (not included) onto the lag screw.

Sep-2014, Rev 1

E-Mount Lag Installation InstructionsInstallation Tools Required: tape measure, roofi ng bar, chalk line, stud fi nder, caulking gun, sealant compatible with roofi ng materials, drill with 7/32" long-style bit, drill or impact gun with 1/2" socket.

Locate, choose, and mark centers of rafters to be mounted. Select the courses of shingles where mounts will be placed.

Carefully lift composition roof shingle with roofi ng bar, just above placement of mount. Remove nails as required. See "Proper Flashing Placement" on next page.

Insert fl ashing between 1st and 2nd course. Slide up so top edge of fl ashing is at least 3/4" higher than the drip edge of the 3rd course and lower fl ashing edge is above the drip edge of 1st course. Mark center for drilling.

Using a 1/2 inch socket on an impact gun drive the lag screw until the QBlock stops rotating easily. DO NOT over-torque.

BI 7.2.3-31

WARNING: Quick Mount PV products are NOT designed for and should NOT be used to anchor fall protection equipment.

A19

Page 20: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

LGate 120 RESIDENTIAL SOLAR MONITORING SOLUTION

Product Datasheet

The LGate 120 is a single-phase electronic watt-hour meter for remote monitoring of solar photovoltaic systems. It features a smart communications module to automatically transmit meter data over cellular or Ethernet networks allowing system owners and operators to easily manage distributed solar assets.

The LGate 120 combines a revenue-grade, solid-state power meter with an advanced communications gateway. These components work in conjunction to remotely monitor the performance of residential solar energy installation regardless of panel or inverter type. The LGate 120 is a one-piece completely under glass meter which installs easily using a standard socket base. Performance data is uploaded in near real-time to the Locus Energy SolarOS monitoring platform which provides a suite of tools and analytics for asset managers.

DATA COLLECTION

AC energy data is collected by the meter and passed to the communications module. Additional system performance data can be collected directly from meteorological sensors and supported inverters via available RS-485 or Zigbee connections. All data is stored in non-volatile memory and then automatically uploaded to the SolarOS and SolarNOC platforms.

NETWORK CONNECTIVITY

The communications gateway inside the LGate 120 supports plug and play connectivity through a cellular or available Ethernet network connection. Once the unit is installed and powered on, it will immediately begin transmitting data without any configuration. For maximum reliability, the communications gateway will automatically route uploads between the wireless and wired connections if either of the networks are unavailable.

FEATURES

• ANSI C12.20 power meter• RS-485 and Zigbee inputs• GSM cellular or Ethernet connectivity• Over the air firmware updates

• Easy, low cost installation• Doesn’t require entrance into the building• Plug and play activation• LCD display

DATALOGGER

Processor ARM9 embedded CPU

OS Custom version of Linux 2.6, OTA firmware updates

Memory 128 MB RAM

Display LCD screen

SPECIFICATIONS

PHYSICAL

Enclosure NEMA 3R Type

Weight 8 oz

Dimensions 6.95” x 6.5” x 7.3”

Environment -20 to 60C, all-weather

Warranty 5 year limited warranty

DIAGRAM – TYPICAL CONFIGURATION

DIMENSIONS

Shielded CAT5

LEGEND

6.95 in

6.31 in

5.46 in

6.00 in

7.30 in

SOCKET METER

COMPLIANCE

ANSI 12.20 class 0.2%

FCC Part 15B

PTCRB

AT&T Carrier Compliance

PV ARRAY

ELECTRICALSERVICE

INVERTER(S)

INTERNET

LGATE 120

METER BASE METER MODULELOCUS ENERGYCOMM MODULE

POWER

Accuracy ANSI 12.20 (Class 0.2%)

Voltage Inputs 120 - 480 VAC

Max. Current Input 200 A

Service Type Single phase , 60 Hz

Socket Type 2S

COMMUNICATION INTERFACE OPTIONS

Model Number LGate120-3Gx LGate120-3Gy LGate120-3Gz

Cellular - 3G GSM

RS-485 2 and 4 wire

Modbus

Zigbee

Ethernet RJ-45 10/100, DHCP/Static

A20

Page 21: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

125 & 200 Amp

011 (closed) U204 (open)

Single M

eter Sockets

Without B

ypass

Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.

Single Meter Sockets - Without Bypass

Meter Mounting Equipment5

Part/UPC Catalog Amp Service ConnectionsNumber Number Rating Jaws Type Access Line Load Neutral

78205142000 011 125 4 1Ø/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/078205142040 011 F 125 4 1Ø/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/078205142045 011 MS73 125 4 1Ø/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/078205142050 011 SF 125 4 1Ø/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/078205144030 927 100 7 3Ø/4W OH/UG #14 - 1/0 #14 - 1/0 #14 - 2/078205156000 204 200 4 1Ø/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM78205156020 204 F 200 4 1Ø/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM78205156030 204 F MS73 200 4 1Ø/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM78205156040 204 MS68 200 4 1Ø/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM78205156035 204 MS68A 200 4 1Ø/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM78205108490 204 MS73 200 4 1Ø/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM78205156005 U204 200 4 1Ø/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM78205156045 U204 F 200 4 1Ø/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM78205156060 U204 F MS73 200 4 1Ø/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM78205156070 U204 MS73 200 4 1Ø/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM78205156140 U207 200 7 3Ø/4W OH/UG #6 - 250MCM #6 - 250MCM #6 - 250MCM78205156170 U207 F 200 7 3Ø/4W UG #6 - 250MCM #6 - 250MCM #6 - 250MCM78205156180 U207 MS73 200 7 3Ø/4W OH/UG #6 - 250MCM #6 - 250MCM #6 - 250MCM

Part/UPC Catalog Overall Dimensions Top KnockoutNumber Number Height Width Depth Provision Layout

78205142000 011 12” 8” 45/8” AW Hub Fig. 178205142040 011 F 12” 8” 45/8” 2” max KO Fig. 178205142045 011 MS73 12” 8” 45/8” AW Hub Fig. 178205142050 011 SF 12” 8” 45/8” 2” max KO Fig. 178205144030 927 17” 8” 45/8” AW Hub Fig. 178205156000 204 15” 8” 45/8” AW Hub Fig. 278205156020 204 F 15” 8” 6” 2” max KO Fig. 278205156030 204 F MS73 15” 8” 6” 2” max KO Fig. 278205156040 204 MS68 15” 8” 45/8” AW / 2” Hub Fig. 278205156035 204 MS68A 15” 8” 45/8” AW / 2” Hub Fig. 278205108490 204 MS73 15” 8” 45/8” None Fig. 278205156005 U204 15” 12” 45/8” None Fig. 378205156045 U204 F 15” 12” 6” (2) 2” max KO Fig. 378205156060 U204 F MS73 15” 12” 6” None Fig. 378205156070 U204 MS73 15” 12” 45/8” None Fig. 378205156140 U207 18” 12” 5” AW Hub Fig. 478205156170 U207 F 18” 12” 5” 21/2” max KO Fig. 478205156180 U207 MS73 18” 12” 5” AW Hub Fig. 4

Application• Single meter position• Receive ANSI C12.10 watthour meters• Surface or flush mount (see chart)

Construction• Ring type• NEMA Type 3R• ANSI 61 gray E-coat finish• Aluminum snap ring included

Standards Accessories• UL 414 Listed • 5th Jaw Kit - 50365• ANSI C12.7 • 200A Triplex Ground - ETB200

• AW Hub

AIC Note:For short circuit currentratings see page 131.

Fig. 1

Fig. 3

Top Provision

Top Provision

Fig. 2

Fig. 4

Knockouts - Conduit Sizes

1W = 1⁄4"1A = 1⁄2"2A = 1⁄2" - 1⁄4"4F = 2” - 11⁄2" - 11⁄4" - 1"4G = 21⁄2" - 2” - 11⁄2" - 11⁄4"Top Provision = See Chart

Knockout Layouts

125 & 200 Amp

Sin

gle

Met

er S

ocke

ts

Wit

hout

Byp

ass

Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.

Single Meter Sockets - Without Bypass

6Meter Mounting Equipment

2A

Style # Suffixes

011 F - Flush Mount(U) 204 MS68 - 2” Conduit Hub(U) 207 MS68A - MS73 + MS68927 MS73 - AL Screw Type Ring

SF - Semi Flush MountSS - Stainless Steel

Top ProvisionTop Provision

1A

4F

4F 4Fbothsides

1W

4F

4G

4G

4G

4G

4G4G

4F4F

bothsides

4Gbothsides

1A

4F

4F

4Fbothsides

A21

Page 22: Teaching plan - irecusa.org … · nec 705.12(d)(2)(b) place this label at p.o.c. to service distribution equipment (i.e. main panel (and subpanel if applicable)) inverter output

Locus Energy, LLC www.locusenergy.com

October 22nd, 2013

This letter is to certify that the LGate 120 and LGate 320 are communication boards built into the Vision Meter 2S CL200 and 16S CL320 socket meters, respectively. Each of these meters was certified to the ANSI C12.20 (class 0.2%) standard by Underwriters Laboratory on June 7, 2013 as part of the Vision Meter Family (Project Number 12CA71134, Job Number 1001541515, and Report Number R12CA71134-ANSI).

ANSI C12.20 is currently recognized as the industry standard for electrical socket meters in both utility and PV monitoring applications. These tests cover both meter accuracy as well as several safety standards including electrical and environmental safety, as well as resistance to various types of mechanical shock. As electrical socket meters are generally installed and maintained by trained and certified professionals, rather than consumers, they do not fit the typical criteria for additional types of UL or IEC certification.

If you have any further questions regarding the product certification of any Locus Energy LGate-branded device, please contact us at [email protected].

The Locus Energy Team

A22