TAE926 3-pole Contactors - ABB Group...ABB CONTROL – FRCTL PRODUCT MARKETING JULY 2002 1/4 Low...

9
TAE 12-30-00 SB8033C3 ! TAE9...26 3-pole Contactors d.c. operated with double-winding coil Rated operational Auxiliary contacts Type Order code Weight current fitted kg AC-3 AC-1 400 V θ < 40 °C state coil voltage state coil voltage code Pack ing A A (see opposite table) (see opposite table) 1 piece 9 25 TAE 9-30-00 1SBL 14 9061 R 00 0.340 12 27 TAE 12-30-00 1SBL 16 9061 R 00 0.340 16 30 TAE 16-30-00 1SBL 18 9061 R 00 0.340 26 45 TAE 26-30-00 1SBL 24 9061 R Voltage - U c Code V d.c. 17 ... 32 51 25 ... 45 52 36 ... 65 54 42 ... 78 58 50 ... 90 55 77 ... 143 62 90 ... 150 66 Replacement Coils For contactor Type Order code Weight kg state coil voltage state coil voltage code Pack ing (see opposite table) (see opposite table) 1 piece TAE9...TAE16 ZAE16 1SBN 15 1490 R 06 0.093 TAE26 ZAE40 1SBN 15 2490 R 06 0.148 00 0.600 1/1 Low Voltage Products 1SBC101001D0201 Ordering Details: TAE... Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges in accordance with the requirements of railway applications. They are also suitable for control from a battery supply. The complimentary technical information not included in these pages can be found in the Main Technical Catalogue for Contactors 1SBC100122C0201. 152 ... 264 68 Other voltages: please consult us. Voltage tolerances (-15 % and +10 %) included in the Uc min. and Uc max. values for the TAE... contactors. Coil voltages and codes: TAE ABB CONTROL – FRCTL PRODUCT MARKETING JULY 2002

Transcript of TAE926 3-pole Contactors - ABB Group...ABB CONTROL – FRCTL PRODUCT MARKETING JULY 2002 1/4 Low...

Page 1: TAE926 3-pole Contactors - ABB Group...ABB CONTROL – FRCTL PRODUCT MARKETING JULY 2002 1/4 Low Voltage Products 1SBC101001D0201 Position 1 Position 3 Position 4 Position 2 Position

TAE 12-30-00

SB

8033

C3

!

TAE9...26 3-pole Contactorsd.c. operated with double-winding coil

Rated operational Auxiliary contacts Type Order code Weightcurrent fitted kg

AC-3 AC-1400 V θ < 40 °C state coil voltage state coil voltage code Packing

A A (see opposite table) (see opposite table) 1 piece

9 25 – – TAE 9-30-00 1SBL 14 9061 R 00 0.340

12 27 – – TAE 12-30-00 1SBL 16 9061 R 00 0.340

16 30 – – TAE 16-30-00 1SBL 18 9061 R 00 0.340

26 45 – – TAE 26-30-00 1SBL 24 9061 R

Voltage - Uc Code V d.c.

17 ... 32 5 125 ... 45 5 236 ... 65 5 442 ... 78 5 850 ... 90 5 577 ... 143 6 290 ... 150 6 6

Replacement CoilsFor contactor Type Order code Weight

kg

state coil voltage state coil voltage code Packing

(see opposite table) (see opposite table) 1 piece

TAE9...TAE16 ZAE16 1SBN 15 1490 R 06 0.093

TAE26 ZAE40 1SBN 15 2490 R 06 0.148

00 0.600

1/1 Low Voltage Products1SBC101001D0201

Ordering Details: TAE...

Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have largevoltage ranges in accordance with the requirements of railway applications. They are also suitable forcontrol from a battery supply. The complimentary technical information not included in these pages canbe found in the Main Technical Catalogue for Contactors 1SBC100122C0201.

152 ... 264 6 8

Other voltages: please consult us.

Voltage tolerances (-15 % and+10 %) included in the Uc min.and Uc max. values for theTAE... contactors.

Coil voltages and codes: TAE

ABB CONTROL – FRCTLPRODUCT MARKETINGJULY 2002

Page 2: TAE926 3-pole Contactors - ABB Group...ABB CONTROL – FRCTL PRODUCT MARKETING JULY 2002 1/4 Low Voltage Products 1SBC101001D0201 Position 1 Position 3 Position 4 Position 2 Position

1/2 Low Voltage Products1SBC101001D0201

B2A A B1

C2

C1

E02

02D

1

ABB

General Technical Data

Contactor types: TAE... 9 12 16 26

Rated insulation voltage Ui

according to IEC 60947-4-1 V 1000according to UL/CSA V 600

Rated impulse withstand voltage Uimp. kV 8

Standards Devices comply with international standards IEC 60947-1 / 60947-4-1and European standards EN 60947-1 / 60947-4-1

Certifications - Approvals ☞ see Technical Catalogue 1SBC100122C0201

Air temperature close to contactor ☞ "Conditions for use" page 1/4, for control voltage limits and authorized mounting positions– fitted with thermal O/L relay °C -25 to +55– without thermal O/L relay °C -40 to +55– for storage °C -60 to +80

Climatic withstand acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II

Operating altitude m < 3000

Shock withstandacc. IEC 60068-2-27 and EN 60068-2-27Mounting position 1 (☞ page 1/4 ) 1/2 sinusoidal shock for 11 ms: no change in contact position

Shock direction Making position Breaking positionA 20 g 20 gB1 10 g 5 g B2 15 g 15 g C1 20 g 20 gC2 20 g 20 g

TAE9...26 ContactorsTechnical Data

Magnet System Characteristics for TAE... Contactors

Contactor types: TAE... 9 12 16 26

Rated control circuit voltage Uc

V d.c. 17 ... 264

Coil operating limits θ < 55 °CUc min. ... Uc max.

Drop-out voltage in % of Uc max. 10 ... 30 %

Coil consumptionvalues for Uc min. ... Uc max.– pull-in value W 65 ... 140 – holding value W 1.0 ... 3.5

Coil time constant– open L/R ms 2 3– closed L/R ms 9 16

Operating timebetween coil energization and:– N.O. contact closing ms 10 ... 16 13...21– N.C. contact opening ms 8 ... 12 11...16 between coil de-energization and– N.O. contact opening ms 5 ... 14 (1) 6 ... 12 (1)

– N.C. contact closing ms 11 ... 17 (1) 8...16(1)

(1) The use of surge suppressors increases the opening time on a scale of 1.1 to 1.5 for a varistor suppressor and on a scale of 4 to 8 for a diode suppressor.

ABB CONTROL – FRCTLPRODUCT MARKETINGJULY 2002

Page 3: TAE926 3-pole Contactors - ABB Group...ABB CONTROL – FRCTL PRODUCT MARKETING JULY 2002 1/4 Low Voltage Products 1SBC101001D0201 Position 1 Position 3 Position 4 Position 2 Position

1/3 Low Voltage Products1SBC101001D0201

M3

M3

Main Pole - Utilization CharacteristicsContactor types: TAE... 9 12 16 26

Rated operational voltage Ue max. V 690

Rated frequency limits Hz 25 ... 400

Conventional free-air thermal current Ith

acc. to IEC 60947-4-1,open contactors θ ≤ 40 °C A 26 28 30 45 with conductor cross-sectional area mm2 4 4 4 6

Rated operational current Ie / AC-1for air temperature close to contactor

θ ≤ 40 °C A 25 27 30 45 Ue max. 690 V θ ≤ 55 °C A 22 25 27 40

θ ≤ 70 °C (1) A – – – – with conductor cross-sectional area mm2 2.5 4 4 6

Utilization categorie AC-3for air temperature close to contactor < 55 °C

Rated operational current Ie AC-3 220-230-240 V A 9 12 17 26

3-phase motors 380-400 V A 9 12 17 26415 V A 9 12 17 26440 V A 9 12 16 26500 V A 9 12 14 22690 V A 7 9 10 17

1000 V A – – – –

Rated operational power AC-3

1500 r.p.m. 50 Hz220-230-240 V kW 2.2 3 4 6.5

1800 r.p.m. 60 Hz 380-400 V kW 4 5.5 7.5 11 3-phase motors 415 V kW 4 5.5 9 11

440 V kW 4 5.5 9 15 500 V kW 5.5 7.5 9 15 690 V kW 5.5 7.5 9 15

1000 V kW – – – –

Rated making capacity AC-3according to IEC 60947-4-1 10 x Ie AC-3

Rated breaking capacity AC-3according to IEC 60947-4-1 8 x Ie AC-3

Short-circuit protection for contactorswithout thermal O/L relay - Motor protection excluded

Ue < 500 V a.c. - gG type fuse A 25 32 32 50

Rated short-time withstand current Icw

at 40 °C ambient temp., in free air,from a cold state 1 s A 250 280 300 400

10 s A 100 120 140 210 30 s A 60 70 80 110

1 min A 50 55 60 90 15 min A 26 28 30 45

Maximum breaking capacitycos ϕ = 0.45 (cos ϕ = 0.35 for Ie > 100 A)

at 440 V A 250 250 250 420 at 690 V A 100 100 100 170

Heat dissipation per pole Ie / AC-1 W 0.8 1 1.2 1.8 Ie / AC-3 W 0.1 0.2 0.35 0.6

Max. electrical switching frequency– for AC-1 cycles/h 600 – for AC-3 cycles/h 600 – for AC-2, AC-4 cycles/h 300

Electrical durability ☞ See A Contactor curves in Technical Catalogue 1SBC100122C0201

Mechanical durability– millions of operating cycles 5– max. mechanical switching frequency cycles/h 3600

(1) Unauthorized for TAE... contactors.

TAE9...26 ContactorsTechnical Data

{

frequency cycles/h 3600

(1) For the corresponding kW/hp/A values of 1500 r.p.m., 50Hz, 3-phase motors, ☞ page 0/0. (2) For the protection of motor starters against short circuits, ☞ page 7/16. (4) Unauthorized for TAE... contactors.

TAE9...26 ContactorsTechnical Data

ABB CONTROL – FRCTLPRODUCT MARKETINGJULY 2002

Page 4: TAE926 3-pole Contactors - ABB Group...ABB CONTROL – FRCTL PRODUCT MARKETING JULY 2002 1/4 Low Voltage Products 1SBC101001D0201 Position 1 Position 3 Position 4 Position 2 Position

1/4 Low Voltage Products1SBC101001D0201

Position 1

Position 3

Position 4

Position 2

Position 5

Position 1 ± 30°

-30° +30°

ABB

ABB

AB

B

AB

B

Mounting Characteristics

Contactor types: TAE... 9 12 16 26

Mounting positions ☞ Shown below

Mounting distances The contactors can be assembled side by side

Fixingon DIN rail 35 x 7.5 mm according to IEC 715 and EN 50022 / EN 50023 35 x 15 mm

by screws (not supplied) 2 x M4

Conditions for UseThe contactor utilisation conditions relating to the Mounting position, Ambient temperature and Control voltage operating limits are summarizedin the table below.

Contactors Mounting position Ambient temperature Control voltage

1,1 + 30°, 2, 3, 4, 5 < 55 °C Uc min. ... Uc max.TAE 9 ... TAE 26

.

.

Mounting Positions (see the above table for authorized positions)

A..., AF..., AE... and TAE... ContactorsTechnical Data

TAE9...26 Contactorsd.c. Operated with Double-Winding Coil

ABB CONTROL – FRCTLPRODUCT MARKETINGJULY 2002

TAE9 to TAE26 accessory compatibilityContactor configuration Front-mounted accessories (1) Side-mounted accessories

Main Availablepoles auxiliary

contacts

Contactor Auxiliary contact Auxiliary contact Pneumatic timer Auxiliary contact Interlock unittypes 1-pole CA 5-.. 4-pole CA 5-.. (2) TP .. A 2-pole CAL 5-11 VM 5-.. or VE 5-..

TAE 9 ... TAE 26 3 0 0 0 1 to 4 x CA 5-.. or 1 x CA 5-.. (4-pole) or 1 x TP .. A + 1 to 2 x CAL 5-11 or1 x VM 5-1 or VE 5-1

+ 1 x CAL 5-11

Page 5: TAE926 3-pole Contactors - ABB Group...ABB CONTROL – FRCTL PRODUCT MARKETING JULY 2002 1/4 Low Voltage Products 1SBC101001D0201 Position 1 Position 3 Position 4 Position 2 Position

1/5 Low Voltage Products1SBC101001D0201

}

Ll

Ll

TAE9...26 ContactorsTechnical Data

Connecting Characteristics

Contactor types: TAE... 9 12 16 26

Main terminals

with cable clamp

Connecting capacity (min. ... max.)

Main conductors (poles)

Rigid:solid (≤ 4 mm2) 1 x mm2 1 ... 4 1.5 ... 6 stranded (≥ 6 mm2) 2 x mm2 1 ... 4 1.5 ... 6

Rigid with connectorsingle for Cu cable mm2 – – – –single for Al/Cu cable mm2 – – – –double for Al/Cu cable mm2 – – – –

Flexible with cable end 1 x mm2 0.75 ... 2.5 1.00 ... 4 2 x mm2 0.75 ... 2.5 1.00 ... 4

Bars or lugs L mm ≤ 8 10l mm > 3.7 4.2

Auxiliary conductors(coil terminals)

Rigid solid 1 x mm2 1 ... 4 2 x mm2 1 ... 4

Flexible with cable end 1 x mm2 0.75 ... 2.5 2 x mm2 0.75 ... 2.5

Lugs L mm ≤ 8

l mm > 3.7

Degree of protection acc. to IEC 60947-1 / Protection against direct contact acc. to VDE 0106 - Part. 100EN 60947-1 and IEC 60529 / EN 60529

– Main terminals IP 20 – Coil terminals IP 20

Screw terminals (delivered in open position, screws of unused terminals must be tightened)

Main terminals (+,-) pozidriv 2 screws M3.5 M4

Coil terminals M3.5 (+,-) pozidriv 2 screws with cable clamp

Tightening torqueMain pole terminals– recommended Nm / lb.in 1.00 / 9 1.7 / 15 – max. Nm 1.20 2.20

Coil terminals– recommended Nm / lb.in 1.00 / 9– max. Nm 1.20

Terminal marking and positioning ☞ See Section 8 of Technical Catalogue 1SBC100122C0201. Same as all AE range.

L < 8 and l > 3.7 for coil terminal - L < 10 and l > 4.2 for built-in auxiliary terminals.

ABB CONTROL – FRCTLPRODUCT MARKETINGJULY 2002

Page 6: TAE926 3-pole Contactors - ABB Group...ABB CONTROL – FRCTL PRODUCT MARKETING JULY 2002 1/4 Low Voltage Products 1SBC101001D0201 Position 1 Position 3 Position 4 Position 2 Position

1/6 Low Voltage Products1SBC101001D0201

Detailed dimension drawings available in DXF and PDF formats.

44

74 76

E13

05D

44

74

E13

07D

76

4412

74

E13

09D

76

44

74

E13

11D

76

44

74

E13

13D

76

44

74

E13

15D

76

4.5

ø 4.5

4.5

35

6050

E01

01D

(M4)

68

74

5.5

4

35 m

m E

N 5

0022

E13

06D

2

10

68

47

100.5

5.5

4

35 m

m E

N 5

0022

E13

08D

2

10

68

74

5.5

4

35 m

m E

N 5

0022

E13

10D

2

10

68

47

107

5.5

4

35 m

m E

N 5

0022

E13

12D

2

10

34

4

68

145

5.5

4

35 m

m E

N 5

0022

E13

16D

2

10 68

127

5.5

4

47

35 m

m E

N 5

0022

E13

14D

2

10

TAE 9, TAE 12 and TAE 16 3-pole Contactors

Dimensions (in mm)

TAE 9, TAE 12, TAE 16 TAE 9, TAE 12, TAE 16+ CA 5 front-mounted 1-pole auxiliary contact block

TAE 9, TAE 12, TAE 16 TAE 9, TAE 12, TAE 16+ CAL 5 side-mounted 2-pole auxiliary contact block + CA 5 front-mounted 4-pole auxiliary contact block

TAE 9, TAE 12, TAE 16 TAE 9, TAE 12, TAE 16+ TP pneumatic timer + WB 75-A on-position latch

TAE 9, TAE 12, TAE 16

ABB CONTROL – FRCTLPRODUCT MARKETINGJULY 2002

Page 7: TAE926 3-pole Contactors - ABB Group...ABB CONTROL – FRCTL PRODUCT MARKETING JULY 2002 1/4 Low Voltage Products 1SBC101001D0201 Position 1 Position 3 Position 4 Position 2 Position

9Detailed dimension drawings available in DXF and PDF formats.

103

74

E13

17D

76

103

74

E13

19D

76

44

74

133

E13

21D

134 35

mm

EN

500

22

E13

22D

95

14*

1

6

10

74

4

60

4.5 4.5

ø 4.5

35 59

50

(M4)

E01

10D

1

60

4.5 4.5

ø 4.5

35 59

50

(M4)

E01

10D

1

4.5

ø 4.5

4.5

35

6050

E01

01D

(M4)

68

74

5.5

4

35 m

m E

N 5

0022

E13

18D

2

10

68

74.5

5.5

4

35 m

m E

N 5

0022

E13

20D

2

10

TAE 9, TAE 12 and TAE 16 3-pole Contactors

Dimensions (in mm)

TAE 9, TAE 12, TAE 16+ VE 5-1 electrical and mechanical interlock unit

TAE 9, TAE 12, TAE 16+ VM 5-1 mechanical interlock unit

TAE 9, TAE 12, TAE 16+ TA 25 DU thermal O/L relay

* For TA 25 DU 32 only

1/7 Low Voltage Products1SBC101001D0201

ABB CONTROL – FRCTLPRODUCT MARKETINGJULY 2002

Page 8: TAE926 3-pole Contactors - ABB Group...ABB CONTROL – FRCTL PRODUCT MARKETING JULY 2002 1/4 Low Voltage Products 1SBC101001D0201 Position 1 Position 3 Position 4 Position 2 Position

1/8 Low Voltage Products1SBC101001D0201

Detailed dimension drawings available in DXF and PDF formats.

54

90

E13

23D

96

93.6

9 6.3

4 10

35 m

m E

N 5

0022

E13

24D

54

90

E13

25D

96 47

10

119.8

9

4

35 m

m E

N 5

0022

E13

26D

54

90

12

74

E13

27D

96

93.6

9 6.3

4 10

35 m

m E

N 5

0022

E13

28D

54

90

E13

29D

96 47

126.3

9 10

4

35 m

m E

N 5

0022

E13

30D

54

90

E13

31D

96 47

146.3

9 10

4

35 m

m E

N 5

0022

E13

32D

54

90

E13

33D

96

9

4 10

35 m

m E

N 5

0022

E13

34D

164.3

34

4

ø 4.2

4.54.5

45

70 80

E01

17D

(M4)

TAE 26 3-pole Contactors

Dimensions (in mm)

TAE 26 TAE 26+ CA 5 front-mounted 1-pole auxiliary contact block

TAE 26 TAE 26+ CAL 5 side-mounted 2-pole auxiliary contact block + CA 5 front-mounted 4-pole auxiliary contact block

TAE 26 TAE 26+ TP pneumatic timer + WB 75-A on-position latch

TAE 26 drilling plan

ABB CONTROL – FRCTLPRODUCT MARKETINGJULY 2002

Page 9: TAE926 3-pole Contactors - ABB Group...ABB CONTROL – FRCTL PRODUCT MARKETING JULY 2002 1/4 Low Voltage Products 1SBC101001D0201 Position 1 Position 3 Position 4 Position 2 Position

123

90

E13

35D

96

93.6

9 6.3

4 10

35 m

m E

N 5

0022

E13

36D

123

90

E13

37D

96

93.6

9 6.3

4 10

35 m

m E

N 5

0022

E13

38D

54

90

147

E13

39D

150

109.4

14*

15.4

93.6

9

6

10

4

E13

40D

3

5 m

m E

N 5

0022

4.5 45

70

ø 4.2

4.5

80

69

E01

26D

(M4)

4.5 45

70

ø 4.2

4.5

80

69

E01

26D

(M4)

ø 4.2

4.54.5

45

70 80

E01

17D

(M4)

TAE 26 3-pole Contactors

Dimensions (in mm)

TAE 26+ VE 5-1 electrical and mechanical interlock unit

TAE 26+ VM 5-1 mechanical interlock unit

TAE 26+ TA 25 DU thermal O/L relay

* For TA 25 DU 32 only

ABB CONTROL – FRCTLPRODUCT MARKETINGJULY 2002

1/9 Low Voltage Products1SBC101001D0201

Detailed dimension drawings available in DXF and PDF formats.