RS6 Rackmount DMX Distribution Splitter RS6 DMX Distribution Splitter User Manual 4 01 - 6 x 5-Pin...

8
Order code: BOTE63 TERMINATE LINK OUT OFF ON 6 5 4 3 2 1 DMX OUTPUT DC DMX OUTPUT DC DMX OUTPUT DC DMX OUTPUT DC DMX OUTPUT DC DMX OUTPUT DC RS6 Rackmount DMX Distribution Splitter User Manual

Transcript of RS6 Rackmount DMX Distribution Splitter RS6 DMX Distribution Splitter User Manual 4 01 - 6 x 5-Pin...

Page 1: RS6 Rackmount DMX Distribution Splitter RS6 DMX Distribution Splitter User Manual 4 01 - 6 x 5-Pin XLR DMX outputs 02 - 6 x 3-Pin XLR DMX outputs 03 - 5-Pin XLR DMX input 04 - 3-Pin

Order code: BOTE63

DMX OUTPUT

TERM

120Ω

DMX OUTPUT

DMX OUTPUT DMX OUTPUT DMX OUTPUT DMX OUTPUT DMX OUTPUT

POWER INPUT:240V~50Hz

FUSE: 1A 250V

DMX INPUT1=Ground2=Data-3=Data+4=NC5=NC

2 43

1 5 1=Ground2=Data-3=Data+

3

1 2

DMX OUTPUT1=Ground2=Data-3=Data+4=NC5=NC

4 23

5 1 1=Ground2=Data-3=Data+

3

2 1

1 2 3 4 5 6TER

MIN

ATE

LIN

K O

UT

DMX INPUT

RS6 DMX Distribution Splitter

TERMINATE

LINK OUT

OFF

ON654321

POWER INPUT:240V~50Hz

FUSE: 1A 250V

DMX OUTPUTDMX INPUT

DMX INPUT1=Ground2=Data-3=Data+4=NC5=NC

2 43

1 5 1=Ground2=Data-3=Data+

3

1 2

DMX OUTPUT1=Ground2=Data-3=Data+4=NC5=NC

4 23

5 1 1=Ground2=Data-3=Data+

3

2 1

DMX OUTPUT

DC

DMX OUTPUT

DC

DMX OUTPUT

DC

DMX OUTPUT

DC

DMX OUTPUT

DC

DMX OUTPUT

DC

RS6 Rackmount DMX Distribution Splitter

User Manual

Page 2: RS6 Rackmount DMX Distribution Splitter RS6 DMX Distribution Splitter User Manual 4 01 - 6 x 5-Pin XLR DMX outputs 02 - 6 x 3-Pin XLR DMX outputs 03 - 5-Pin XLR DMX input 04 - 3-Pin

www.prolight.co.uk RS6 DMX Distribution Splitter User Manual 2

Safety advice

WARNINGFOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.

• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.

• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessaryfortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.

• Pleasenotethatdamagescausedbyusermodificationstothisequipmentarenotsubjecttowarranty.

IMPORTANT:The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONSIfthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageandthewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.

Donotendangeryourownsafetyandthesafetyofothers!

Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.

• Neverletthepowercablecomeintocontactwithothercables.Handlethepowercableandallmainsvoltageconnectionswithparticularcaution!

• Neverremovewarningorinformativelabelsfromtheunit.

• Donotopentheequipmentanddonotmodifytheunit.

• Donotswitchtheequipmentonandoffinshortintervals,asthiswillreducethesystem’slife.

• Onlyusetheequipmentindoors.

• Donotexposetoflammablesources,liquidsorgases.

• Alwaysdisconnectthepowerfromthemainswhenequipmentisnotinuseorbeforecleaning!Onlyhandlethepower-cablebytheplug.Neverpullouttheplugbypullingthepower-cable.

• Makesurethattheavailablemainssupplyvoltageis240VAC,50Hz.

• Makesurethatthepowercableisnevercrimpedordamaged.Checktheequipmentandthepowercableperiodically.

• Iftheequipmentisdroppedordamaged,disconnectthemainspowersupplyimmediatelyandhaveaqualifiedengineerinspecttheequipmentbeforeoperatingagain.

• Iftheequipmenthasbeenexposedtodrastictemperaturefluctuation(e.g.aftertransportation),donotconnectpowerorswitchitonimmediately.Thearisingcondensationmightdamagetheequipment.Leavetheequipmentswitchedoffuntilithasreachedroomtemperature.

• Ifyourproductfailstofunctioncorrectly,stopuseimmediately.Packtheunitsecurely(preferablyintheoriginalpackingmaterial),andreturnittoyourProLightdealerforservice.

• Onlyusefusesofsametypeandrating.

• Repairs,servicingandpowerconnectionmustonlybecarriedoutbyaqualifiedtechnician.THISUNITCONTAINSNOUSERSERVICEABLEPARTS.

• Thisfixtureisforprofessionaluseonly-itisnotdesignedfororsuitableforhouseholduse.Theproductmustbeinstalledbyaqualifiedtechnicianinaccordancewithlocalterritoryregulations.Thesafetyoftheinstallationistheresponsibilityoftheinstaller.Thefixturepresentsrisksofsevereinjuryordeathduetofirehazards,electricshockandfalls.

• WARRANTY:Oneyearfromdateofpurchase.

CAUTION!KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS

CAUTION! TAKE CARE USING THIS EQUIPMENT!HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!

Page 3: RS6 Rackmount DMX Distribution Splitter RS6 DMX Distribution Splitter User Manual 4 01 - 6 x 5-Pin XLR DMX outputs 02 - 6 x 3-Pin XLR DMX outputs 03 - 5-Pin XLR DMX input 04 - 3-Pin

www.prolight.co.uk RS6 DMX Distribution Splitter User Manual 3

Product overview & technical specifications

AsixwayDMXbooster/distributorfeaturingoneinput,linkoutputandsixoutputseachelectronicallyisolatedfrombotheachotherandfromtheinput.TheRS6canbeusedtosimplifyDMXcablingallowinglightingsystemstobecabledinastarformatwhileworkingtopreventdataerrors.EachofthesixoutputsfeaturesanindependentdrivercoupledwithDCandDMXindicatorLEDs.Housedwithina1U19”,rackmountchassistheRS6isideallysuitedtoprofessionalapplications.

• 6x3-Pin&5-PinXLRoutputs

• Linkoutputwithswitchableterminationfacility

• 1U,19”rackmountchassis

• IECpowerinput

RS6 Rackmount DMX Distribution Splitter

Specifications

Powersupply 240V,50Hz

Fuse 1A250V

Dimensions 44x483x145mm

Weight 2.8kg

Ordercode BOTE63

DMX OUTPUT

DMX OUTPUT

TERM

120Ω

DMX OUTPUT

DMX OUTPUT DMX OUTPUT DMX OUTPUT DMX OUTPUT DMX OUTPUT

TERMINATE

LINK OUT

DMX OUTPUT DMX OUTPUT DMX OUTPUT DMX OUTPUT DMX OUTPUT

POWER INPUT:240V~50Hz

FUSE: 1A 250V

DMX INPUT1=Ground2=Data-3=Data+4=NC5=NC

2 43

1 5 1=Ground2=Data-3=Data+

3

1 2

DMX OUTPUT1=Ground2=Data-3=Data+4=NC5=NC

4 23

5 1 1=Ground2=Data-3=Data+

3

2 1

OFF

ON

DC

654321

1 2 3 4 5 6TER

MIN

ATE

LIN

K O

UT

DMX INPUT

RS6 DMX Distribution Splitter

145mm

483mm

44mm

DMX OUTPUT

TERM

120Ω

DMX OUTPUT

DMX OUTPUT DMX OUTPUT DMX OUTPUT DMX OUTPUT DMX OUTPUT

POWER INPUT:240V~50Hz

FUSE: 1A 250V

DMX INPUT1=Ground2=Data-3=Data+4=NC5=NC

2 43

1 5 1=Ground2=Data-3=Data+

3

1 2

DMX OUTPUT1=Ground2=Data-3=Data+4=NC5=NC

4 23

5 1 1=Ground2=Data-3=Data+

3

2 1

1 2 3 4 5 6TER

MIN

ATE

LIN

K O

UT

DMX INPUT

RS6 DMX Distribution Splitter

TERMINATE

LINK OUT

OFF

ON654321

POWER INPUT:240V~50Hz

FUSE: 1A 250V

DMX OUTPUTDMX INPUT

DMX INPUT1=Ground2=Data-3=Data+4=NC5=NC

2 43

1 5 1=Ground2=Data-3=Data+

3

1 2

DMX OUTPUT1=Ground2=Data-3=Data+4=NC5=NC

4 23

5 1 1=Ground2=Data-3=Data+

3

2 1

DMX OUTPUT

DC

DMX OUTPUT

DC

DMX OUTPUT

DC

DMX OUTPUT

DC

DMX OUTPUT

DC

DMX OUTPUT

DC

Page 4: RS6 Rackmount DMX Distribution Splitter RS6 DMX Distribution Splitter User Manual 4 01 - 6 x 5-Pin XLR DMX outputs 02 - 6 x 3-Pin XLR DMX outputs 03 - 5-Pin XLR DMX input 04 - 3-Pin

www.prolight.co.uk RS6 DMX Distribution Splitter User Manual 4

01-6x5-PinXLRDMXoutputs

02-6x3-PinXLRDMXoutputs

03-5-PinXLRDMXinput

04-3-PinXLRDMXinput

05-5-PinXLRDMXoutputlink

06-3-PinXLRDMXoutputlink

07-DC/DMXoutputindicators

08-Terminate/Linkoutbutton

09-Poweron/offswitch

10-IECpowerinput

11-Fuse:1A250V

12-Earthpoint

Inthebox:1 x DMX distribution splitter, 1 x power cable & 1 x user manual

Technical specifications

DMX OUTPUT

TERM

120Ω

DMX OUTPUT

DMX OUTPUT DMX OUTPUT DMX OUTPUT DMX OUTPUT DMX OUTPUT

POWER INPUT:240V~50Hz

FUSE: 1A 250V

DMX INPUT1=Ground2=Data-3=Data+4=NC5=NC

2 43

1 5 1=Ground2=Data-3=Data+

3

1 2

DMX OUTPUT1=Ground2=Data-3=Data+4=NC5=NC

4 23

5 1 1=Ground2=Data-3=Data+

3

2 1

1 2 3 4 5 6TER

MIN

ATE

LIN

K O

UT

DMX INPUT

RS6 DMX Distribution Splitter

TERMINATE

LINK OUT

OFF

ON654321

POWER INPUT:240V~50Hz

FUSE: 1A 250V

DMX OUTPUTDMX INPUT

DMX INPUT1=Ground2=Data-3=Data+4=NC5=NC

2 43

1 5 1=Ground2=Data-3=Data+

3

1 2

DMX OUTPUT1=Ground2=Data-3=Data+4=NC5=NC

4 23

5 1 1=Ground2=Data-3=Data+

3

2 1

DMX OUTPUT

DC

DMX OUTPUT

DC

DMX OUTPUT

DC

DMX OUTPUT

DC

DMX OUTPUT

DC

DMX OUTPUT

DC

08

12

12

11 03 04 05 0610

0901 02

07

Page 5: RS6 Rackmount DMX Distribution Splitter RS6 DMX Distribution Splitter User Manual 4 01 - 6 x 5-Pin XLR DMX outputs 02 - 6 x 3-Pin XLR DMX outputs 03 - 5-Pin XLR DMX input 04 - 3-Pin

www.prolight.co.uk RS6 DMX Distribution Splitter User Manual 5

DMX OUTPUT

TERM

120Ω

DMX OUTPUT

DMX OUTPUT DMX OUTPUT DMX OUTPUT DMX OUTPUT DMX OUTPUT

DMX INPUT1=Ground2=Data-3=Data+4=NC5=NC

2 43

1 5 1=Ground2=Data-3=Data+

3

1 2

DMX OUTPUT1=Ground2=Data-3=Data+4=NC5=NC

4 23

5 1 1=Ground2=Data-3=Data+

3

2 1

1 2 3 4 5 6TER

MIN

ATE

LIN

K O

UT

DMX INPUT

DMX Controller

Operating instructions

Setup:ConnectaDMXsignalcablefromalightingconsoleorfixtureintotheDMXInputeitherviathe3-Pinor5-Pinmaleconnectorontherearpanel.TheRS6has6outputseachwithboth3-Pinand5-PinXLRconnectors,onlyoneofthetwoconnectionsshouldbeusedforeachDMXoutput.FromeachDMXoutputasignalcablemaybeconnectedwithupto32fixturespersignalline,andupto100mcablelength.ConnecttheRS6toasuitable240VAC~50HzmainssupplyviatheIECmainsinlet.

LED indicators:TheRS6isfittedwithsignalandDCindicators.Undernormalconditions,withDMXsignalpassingthroughtheunitbothLEDswillbeilluminated.TheDMXLEDindicatesthepresenceofaDMXsignal.TheDCLEDindicatestheDMXdrivecircuitisfunctioningcorrectly.

Link out:TheRS6DMXdistributorhasalinkoutfacility.Whenthelinkoutfacilityisnotused,the“Terminate”switchshouldbeactivatedtoterminatetheDMXinputsignal.

Example connection diagrams:

Page 6: RS6 Rackmount DMX Distribution Splitter RS6 DMX Distribution Splitter User Manual 4 01 - 6 x 5-Pin XLR DMX outputs 02 - 6 x 3-Pin XLR DMX outputs 03 - 5-Pin XLR DMX input 04 - 3-Pin

www.prolight.co.uk RS6 DMX Distribution Splitter User Manual 6

DMX setup

FurtherDMXcablescanbepurchasedfromallgoodsoundandlightingsuppliersorProLightConceptsdealers.Pleasequote:

CABL10 – 2mCABL11 – 5mCABL12 – 10m

Setting the DMX address:

TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachfixturerequiresa“startaddress”from1-512.Afixturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannelindicatedbythestartaddress.Forexample,afixturethatoccupiesoruses7channelsofDMXandwasaddressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthechainstartsat107.

DMX 512:

DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligentfixturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothefixture.DMXdataissentasserialdatathattravelsfromfixturetofixtureviatheDATA“IN”andDATA“OUT”XLRterminalslocatedonallDMXfixtures(mostcontrollersonlyhaveadata“out”terminal).

DMX linking:

DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogetherandoperatefromasinglecontroller,aslongasallfixturesandthecontrollerareDMXcompliant.ToensureproperDMXdatatransmission,whenusingseveralDMXfixturestrytousetheshortestcablepathpossible.TheorderinwhichfixturesareconnectedinaDMXlinedoesnotinfluencetheDMXaddressing.Forexample;afixtureassignedtoaDMXaddressof1maybeplacedanywhereinaDMXline,atthebeginning,attheend,oranywhereinthemiddle.WhenafixtureisassignedaDMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,nomatterwhereitislocatedintheDMXchain.

DATA cable (DMX cable) requirements (for DMX operation):

ThisfixturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,seeimagebelow.

Also remember that DMX cable must be daisy chained and cannot be split.

Page 7: RS6 Rackmount DMX Distribution Splitter RS6 DMX Distribution Splitter User Manual 4 01 - 6 x 5-Pin XLR DMX outputs 02 - 6 x 3-Pin XLR DMX outputs 03 - 5-Pin XLR DMX input 04 - 3-Pin

www.prolight.co.uk RS6 DMX Distribution Splitter User Manual 7

Terminationreducessignaltransmissionproblemsandinterferance.itisalwaysadvisabletoconnectaDMXterminal,(resistance120Ohm1/4W)betweenpin2(DMX-)andpin3(DMX+)ofthelastfixture.

5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C

3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)

3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)

5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C

DMX setup

Notice:

Besuretofollowthediagramsbelowwhenmakingyourowncables.DonotconnectthecablesshieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRsoutercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.

Special note:

Line termination:

Whenlongerrunsofcableareused,youmayneedtouseaterminatoronthelastunittoavoiderraticbehaviour.

Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin - Order ref: CABL9O, 5-pin - Order ref: CABL89)

5-pin XLR DMX connectors:

Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRfixturesmaybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.

Page 8: RS6 Rackmount DMX Distribution Splitter RS6 DMX Distribution Splitter User Manual 4 01 - 6 x 5-Pin XLR DMX outputs 02 - 6 x 3-Pin XLR DMX outputs 03 - 5-Pin XLR DMX input 04 - 3-Pin

www.prolight.co.uk RS6 DMX Distribution Splitter User Manual 8

WEEE notice

Correct Disposal of this Product (Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries with separate collection systems)

Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedofwithotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtotheenvironmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromothertypesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.

Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheirlocalgovernmentoffice,fordetailsofwhereandhowtheycantakethisitemforenvironmentallysaferecycling.

Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthepurchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.