PSK Controllers Ltd.psk.cc/wp-content/uploads/2017/06/CSKMR-OFF-new-eng.pdf · t1 t2 TOP 8 9 15 A1...

1
CSKMR-OFF Asymmetrical flasher cyclic pause first Controllers Ltd R sk Timing Relay Dimensions 32 47 72 45 SIDE CSKMR-OFF 230VAC 400VAC 10VAC 48VAC 12VAC 24VAC 110VDC 80VDC 60VDC 48VDC 12VDC 24VDC VAC VDC 15 S 16 18 ( + ) ~ (A1) 10A 250VAC cos =1 φ ~ ( - ) (A2) U R t1 t2 t1 t2 t1 t2 TOP 89 15 A1 18 16 A2 17.5 1 3 5 7 6 4 2 9 10 1s 10s 60s 10m 60m 10h 1 3 5 7 8 6 4 2 9 10 1s 10s 60s 10m 60m 10h Un R T1 T2 CSKMR-OFF Function U R t1 t2 t1 t2 t1 t2 Ordering information 230VAC 400VAC 110VAC 48VAC 12VAC 24VAC 110VDC 80VDC 60VDC 48VDC 12VDC 24VDC VAC VDC CSKMR-OFF Supply Voltage V Supply voltage: 240VAC Supply tolerance: ± 10% Incoming Supply terminals: A1 (+) – A2 refer to table below. Rated power consumption: 2 VA Rated frequency for as voltage: 48 to 63 Hz Duty cycle: 100% Reset time: 30 ms Drop off voltage: ≥ 20% of nominal voltage. Incoming supply circuit Power on: LED green (Un) Indicates of supply voltage Relay energized: LED red (R) indicates of relay energized. Display Base accuracy at min. and max scale: ±1% Adjusting accuracy: <5% of max scale value Repetition accuracy under constant condition: <0.5% (as % of full range) Voltage influence: No Temperature influence: < 0.01% / °C Accuracy Environmental conditions Permissible ambient temperature: -25°C….+55°C Storage temperature: -25°C….+70°C Transport temperature: -25°C….+70°C Relative humidity (acc. IEC 721-3-3 CLASS 3K3): 15% to 85% Vibration resistance (acc. IEC 68-2-6): 10 TO 55 H Output circuit Relay: 1 C/O Rated voltage: 250 Vac Switching capacity ac: 2000 VA (8A / 250V) COS = 1 Switching capacity dc: 3 A 30 Vdc Max switching capacity ac: 10 A Mechanical life: 1 x 10 6 operations Electrical life at 1000 VA COS =1: 200.000 operations Dimensions & weight Width: 18 mm Height: 89 mm Depth (excl. DIN-profile): 64 mm Weight: 56 gram When input voltage is applied (A1) (A2) the me (t1 = pause) begins to run relay remains at the off posion. On compleon of (t1) the output relay energize and remains in the on posion during me (t2=pulse) LED (R) turned on. The output relay (R) connues to operate in the set pulse-pause rao for as long as the input voltage is maintained. The mer will turned off and resets itself if power is disconnected. Connections 15 S 16 18 ( + ) ~ (A1) 10A 250VAC cos =1 φ ~ ( - ) (A2) Connections Timing T1/T2 Timing T1/T2 1s .... 10h General specifications Main Standards: IEC 61812-1, IEC 61000-6-2, EN 50178 Additional standards: IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5 Protection class open air: IP20 Protection class enclosed (accessible front): IP40 Self-extinguishing plastic housing UL V0 acc IEC 529 Mounting position: on DIN-rail TS 35 according to EN 50022 Mounting position: vertically Terminal : acc IEC 60947-7-1, IEC 60998-1 Terminal Capacity:1x4mm 2 without multicore cable end 1x0.5 to 2.5mm 2 with/without multicore cable end PSK Controllers Ltd.

Transcript of PSK Controllers Ltd.psk.cc/wp-content/uploads/2017/06/CSKMR-OFF-new-eng.pdf · t1 t2 TOP 8 9 15 A1...

  • CSKMR-OFFAsymmetrical flasher cyclic pause first

    Controllers Ltd

    R

    sk

    Tim

    ing

    Rel

    ayDimensions

    32

    47

    72

    45

    SIDE

    CSKMR-OFF

    230VAC400VAC10VAC48VAC

    12VAC24VAC

    110VDC80VDC60VDC48VDC

    12VDC24VDC

    VAC VDC

    15

    S

    16 18(

    +

    )~

    (A1)

    10A250VACcos =1φ

    ~(

    -

    )

    (A2)

    U

    Rt1 t2 t1 t2 t1 t2

    TOP

    89

    15

    A1

    18 16

    A2

    17.5

    13

    5

    7 86

    42

    910

    1s10s

    60s

    10m60m

    10h

    13

    5

    7 86

    42

    910

    1s10s

    60s

    10m60m

    10h

    Un

    R

    T1

    T2 CSK

    MR

    -OFF

    Function

    U

    Rt1 t2 t1 t2 t1 t2

    Ordering information

    230VAC400VAC110VAC

    48VAC

    12VAC24VAC

    110VDC80VDC60VDC48VDC

    12VDC24VDC

    VAC VDCCSKMR-OFFSupply Voltage

    V

    Supply voltage: 240VACSupply tolerance: ± 10%Incoming Supply terminals: A1 (+) – A2 refer to table below.Rated power consumption: 2 VARated frequency for as voltage: 48 to 63 HzDuty cycle: 100%Reset time: 30 msDrop off voltage: ≥ 20% of nominal voltage.

    Incoming supply circuit

    Power on: LED green (Un) Indicates of supply voltageRelay energized: LED red (R) indicates of relay energized.

    Display

    Base accuracy at min. and max scale: ±1%Adjusting accuracy: