PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades...

36
1 Catalog 2017 www.isoroc.pl PRODUCT CATALOG 2017 ISOLAM-G bevelled, coated lamella λ≤0,037 W/(m·K) ISOFAS-C1 one-side coated slab λ≤0,036 W/(m·K) ISOFAS-C2  both-sides coated slab λ≤0,036 W/(m·K) New products:

Transcript of PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades...

Page 1: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

1

Catalog 2017

www.isoroc.pl

PRODUCT CATALOG

2017

ISOLAM-G bevelled, coated lamella λ≤0,037 W/(m·K)

ISOFAS-C1  one-side coated slab λ≤0,036 W/(m·K)

ISOFAS-C2  both-sides coated slab λ≤0,036 W/(m·K)

New products:

Page 2: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

2

Catalog 2017

Wroclaw, ISOFAS

Krogen, Norrköping, ISOFAS-SE

Warsaw, ISOACOUSTIC

The company Isoroc Polska S.A. was founded in 2004. It is a producer of the highest quality ecological products of mineral wool. The wool as a natural , nonorganic product is obtained by melting rocks – basalt and gabbro. It provides an excellent thermal and acoustic insulation, and high fire resistance. Isoroc Polska strengthens its young brand on the market through a wide range of top quality insulation products applied in the construction industry.

The headquarter of capital group Isoroc is located in Austria. The company takes pride in a long-standing experience of production and sale on the Russian market (where it also has a factory) as well as in sale on the demanding EU markets. Isoroc Polska S.A. is a producer of a wide range of mineral wool products which are applied in numerous construction elements in the building industry ensuring improved energetic and acoustic effectiveness, and fire protection.

Our products greatly contribute to energy saving thanks to their excellent thermal and acoustic insulation, and high fire resistance. They help to create a pleasant atmosphere indoors, ensure fire safety, and improve the comfort of living. Constant high quality of our products is ensured by current checks in our specialist quality laboratory, CE mark for all our products, and quality certificates in accordance with ISO 9001:2008.

MINERAL WOOL OF THE HIGHEST GRADE

Page 3: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

3

Catalog 2017

MINERAL WOOL OF THE HIGHEST GRADE

Low thermal conductivity

High fire resistance

Resistance against water absorption

Good sound proofing properties

Ecological safety

Page 4: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

4

Catalog 2017

MINERAL WOOL OF THE HIGHEST GRADE

Thermal insulation of attic

Acoustic insulation of partition walls

Thermal insulation of ceilingsThermal insulation of floors

Thermal insulation of external walls

Thermal insulation of flat roofs

PRODUCTS

RECOMMENDED APPLICATION

X POSSIBLE APPLICATION ISO

LIG

HT

ISO

ACO

UST

IC

ISO

VEN

T-M

ISO

VEN

T-M

W

ISO

VEN

T

ISO

PAN

EL-W

ISO

FAS/

ISO

FAS-

SE

ISO

FAS-

C1/I

SOFA

S-C2

N

EW

ISO

PAN

EL\I

SOPA

NEL

-SE

ISO

FAS-

P

ISO

FAS-

LM

ISO

FAS-

LM

beve

lled

ISO

LAM

-G

NEW

ISOFA

S-LM

G

ISO

PAN

EL-D

ISO

ROO

F-T

ISO

ROO

F-B

ISO

ROO

F-H

NEW

ISO

ROO

F

ISO

LOO

SE

Attics X X

Ceilings fixed on joists X

Ventilated flat roofs X

Suspended ceilings X

Frame construction X X

Partition walls X

Shell walls X X

Cavity walls X X

Ventilated facades X

External walls light-dry method X

External walls heavy-dry method X

External walls light-wet method (ETICS)

Concrete soffits X

Ventilated flat roofs and attics

Floating floors systems X

Flat roofs

Page 5: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

5

Catalog 2017

CONTENTS:GENERAL BUILDING CONSTRUCTION

ISOLIGHT ...................................................................................................................................................................................6 attics, ceilings fixed on joists, partition walls, suspended ceilings, shell walls, outside cavity walls, steel structures, ventilated flat roofs, in steel cassettes

ISOACOUSTIC .........................................................................................................................................................................7 external façades with panel façades insulated by light-dry method with cladding made of stone, glass, PVC, etc., ceilings cladded from bottom (suspended ceilings), in internal structures of partition walls, outside cavity walls with ventilated and non-ventilated air-gap, filling of wooden or steel frame structures, ventilated flat roofs, extrenal walls with glass or stone facing, in steel cassettes

VENTILATED FAÇADE

ISOVENT-M.................................................................................................................................................................................8 external façades with panel façades insulated by light-dry method with cladding made of stone, glass, PVC, etc., in internal structures of partition walls, outside cavity walls with ventilated and non-ventilated air-gap, filling of wooden or steel frame structures

ISOVENT-MW............................................................................................................................................................................9 external façades with panel façades insulated by light-dry method with cladding made of stone, glass, PVC, etc., in internal structures of partition walls, outside cavity walls with ventilated and non-ventilated air-gap, filling of wooden or steel frame structures, acoustic insulation in acoustic screens

ISOVENT ..................................................................................................................................................................................10 external façades with panel façades insulated by light-dry method with cladding made of stone, glass, PVC, etc., in internal structures of partition walls, outside cavity walls with ventilated and non-ventilated air-gap, filling of wooden or steel frame structures

ISOPANEL-W .........................................................................................................................................................................11 external façades with panel façades insulated by light-dry method with cladding made of stone, glass, PVC, etc., in internal structures of partition walls, outside cavity walls with ventilated and non-ventilated air-gap, filling of wooden or steel frame structures, acoustic insulation in acoustic screens

ETICS

ISOFAS / ISOFAS-SE / ISOFAS-C1 / ISOFAS-C2 / ISOPANEL / ISOPANEL-SE / ISOFAS-P.............12-15 external walls insulated by light-wet method in so called External Thermal Insulation Composite System (ETICS)

ISOFAS-LM ..............................................................................................................................................................................16 external walls insulated by light-wet method (ETICS) and ceilings over unheated rooms such as garage ceilings

GARAGE SYSTEM/SOFFIT PROTECTION

ISOFAS-LM (bevelled) ......................................................................................................................................................17 insulation of concrete soffit over unheated spaces like garages

ISOLAM-G............................................................................................................................................................................18 insulation of concrete soffit over unheated spaces like garages

ISOFAS-LMG.......................................................................................................................................................................19 insulation of concrete soffit over unheated spaces like garages

FLAT ROOF

ISOPANEL-D - SystemISODACH ..................................................................................................................................20 non-ventilated coverings in flat roofs for insulation in 2-layers ISODACH system (as a base coat layer)

ISOROOF-T - System ISODACH......................................................................................................................................21 non-ventilated coverings in flat roots for insulation in 2-layers ISODACH system (as a top layer)

ISOROOF-B - ISODACH MONO......................................................................................................................................22 non-ventilated coverings in flat roofs for insulation in 1-layer ISODACH MONO system, as well as for insulation of floors under floor base coat (normally loaded)

ISOROOF-H - ISODACH MONO......................................................................................................................................23 non-ventilated coverings in flat roofs for insulation in 1-layer ISODACH MONO system, as well as for insulation of floors under floor base coat (normally loaded)

ISOROOF - ISODACH MONO...........................................................................................................................................24 non-ventilated coverings in flat roots for insulation in 1-layer ISODACH MONO system, as well as for insulation of floors for concrete screed

VENTILATED FLAT ROOF

ISOLOOSE ................................................................................................................................................................................25 ventilated flat roofs, cavity walls, useless attic  on a concrete ceiling

Page 6: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

6

Catalog 2017

Product description:Slabs of mineral wool for thermal, acoustic and fire insulation:

9 of attics, between rafters, 9 floors between joists, 9 ceilings cladded from bottom (suspended ceilings), 9 in internal structures of partition walls, 9 in cavity walls with ventilated and non-ventilated air gap, 9 for filling out of wooden or steel frame structures, 9 in ventilated flat roofs 9 in steel cassettes.

Properties: 9 light, 9 elastic, easy adapting to insulated surface, 9 easy in assembly and processing, 9 non-flammable, excellent protection against fire, 9 hydrophobized (do not absorb moisture), 9 they tightly fill in insulated spaces, and therefore

formation of thermal bridges is effectively avoided during assembly,

9 they are produced from natural raw material, 9 ensure proper heat comfort and allow wall to breathe, 9 resistant to chemical and biological corrosion, 9 they are not subject to erosion, their durability

exceeds that of plastics.

Technical properties:

ISOLIGHTMW-EN 13162-T4-DS(70,90)-CS(10)0,5-WS-WL(P)-MU1

Declared properties of the product acc. toPN-EN13162+A1:2015-04

Test methodUnit of

measure-ment

Levels or tolerances

Classes of levels codes

Values

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2

Width (class of dimensional tolerance) [%] [-] ± 1,5

Thickness (class of thickness tolerance)

<100 mmPN-EN 823

[mm/%]T4

- 3mm / + 5%≥100 mm [%/mm] - 3% / + 5mm

Dimensional stability under specified temperature and relative humidity conditions

PN-EN 1604[%]

DS(70,90)± 1,0 (change of thickness,

length and width)[mm/m] ± 1 (change of flatness)

Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)0,5 ≥ 0,5

Short-term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0

Long term water absorption by partial immersion PN-EN 12087 [kg/m2] WL(P) ≤ 3,0

Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,037

Reaction to fire PN-EN 13501-1 A to F Euroclass A1

Apparent density PN-EN 1602 [kg/m3] [-] 35

Insulation of slanting roof

1- Plasterboard2- ISOLIGHT wool3 - Air gap4 - Battens5 - Roof covering

Thickness [mm]

50 75 100 150 200Thermal resistance RD [m2K/W]

1,35 2,00 2,70 4,05 5,40

Declared thermal resistance RD for respective thicknesses of the product

Dimensions and packaging

Slabs dimensionsNo. of slabs

in a packageSurface covered

by packagePackage volume

No. ofpackages on

a pallet

Surface covered by slabs on a pallet

Mineral wool volume on a

palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3] [pcs] [m2] [m3]50

1000 500

12 6,00

0,30 20

120

6,0075 8 4,00 80

100 6 3,00 60150 4 2,00 40200 3 1,50 30

On customer request there is a possibility of producing plates with other dimensions.

ISOLIGHT slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

ISOLIGHT Mineral wool slabs General building construction

Page 7: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

7

Catalog 2017

Product description:Slabs of mineral wool for thermal, acoustic and fire insulation:

9 external façades with panel façades insulated by light-dry method, with stone, glass or PVC cladding etc.,

9 attics, between rafters, 9 floors between joists, 9 ceilings cladded from bottom (suspended ceilings), 9 in internal structures of partition walls, 9 in cavity walls with ventilated and non-ventilated

air gap, fillings of wooden or steel frame structures, 9 in ventilated flat roofs, 9 external walls with glass or stone facing 9 in steel cassettes.

Properties: 9 light, 9 elastic, easy adapting to insulated surface, 9 easy in assembly and processing, 9 non-flammable, excellent protection against fire, 9 hydrophobized (do not absorb moisture), 9 they tightly fit in insulated spaces, and therefore

formation of thermal bridges is effectively avoided during assembly,

9 they are produced from natural raw materials, 9 ensure proper heat comfort and allow walls to breathe, 9 resistant to chemical and biological corrosion, 9 they are not subject to erosion, their durability

exceeds that of plastics.

Technical properties:

Insulation of external three-layer wall

1 - Mineral render2 - Ceramic hollow-bricks3 -Ventilation gap4 - ISOACOUSTIC5 - Connector6 - Ceramic hollow bricks7 - Plaster

Dimensions and packagingSlabs dimensions

No. of slabs in a package

Surface covered by package

Package volume

No. ofpackages on

a pallet

Surface covered by slabs on a pallet

Mineral wool volume on a

palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3] [pcs] [m2] [m3]50

1000 600

12 7,00

0,36 16

115,2

5,7675 8 4,80 76,8

100 6 3,60 57,6150 4 2,40 38,4200 3 1,80 28,8

ISOACOUSTICMW-EN 13162-T4-DS(70,90)-CS(10)0,5-WS-WL(P)-MU1-AW0,80 d=50÷74 mm

MW-EN 13462-T4-DS(70,90)-CS(10)0,5-WS-WL(P)-MU1-AW0,90 d=75÷200 mm

Declared properties of the product acc. toPN-EN13162+A1:2015-04

Test methodUnit of

measure-ment

Levels or tolerances

Classes of levels codes

Values

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2

Width (class of dimensional tolerance) [%] [-] ± 1,5

Thickness (class of thickness tolerance)

<100 mmPN-EN 823

[mm/%]T4

-3 mm/ +5%≥100 mm [%/mm] -3%/ +5 mm

Dimensional stability under specified temperature and relative humidity conditions

PN-EN 1604[%]

DS(70,90)± 1,0 (change of thickness,

length and width)[mm/m] ± 1 (change of flatness)

Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)0,5 ≥ 0,5

Short-term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0

Long term water absorption by partial immersion PN-EN 12087 [kg/m2] WL(P) ≤ 3,0

Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1

Weighted sound absorption coefficient

<75 mmPN-EN ISO354 [-]

AW0,80 0,80

≥75 mm AW0,90 0,90

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,036

Reaction to fire PN-EN 13501-1 A to F Euroclass A1

Apparent density PN-EN 1602 [kg/m3] [-] 50

On customer request there is a possibility of producing plates with other dimensions.

ISOACOUSTIC slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

ISOACOUSTIC Mineral wool slabs General building construction

Thickness [mm]

50 75 100 150 200Thermal resistance RD [m2K/W]

1,35 2,05 2,75 4,15 5,55

Declared thermal resistance RD for respective thicknesses of the product

12

3

45

6

7

GEN

ERA

L BU

ILDIN

G

CON

STRU

CTIO

N

Page 8: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

8

Catalog 2017

Product description: Slabs of mineral wool for thermal, acoustic and fire insulation of:

9 external façade insulated by light-dry method (for instance made of sheet, board, siding),

9 three-layer walls, 9 external walls with stone or glass façade, 9 stud walls, 9 in internal structures of partition walls, 9 three-layer foundation walls, 9 acoustic screens.

Properties: 9 easy in assembly and processing, 9 non-flammable, excellent protection against fire, 9 hydrophobized (do not absorb moisture), 9 they tightly fit in insulated spaces, and therefore,

formation of thermal bridges is effectively avoided during assembly,

9 they are produced from natural raw materials, 9 ensure proper heat comfort and allow walls to breathe, 9 resistant to chemical and biological corrosion, 9 more durable than plastic, resistant to errosion.

Technical properties:

ISOVENT-MMW-EN 13162-T3-DS(70,90)-CS(10)10-TR5-WS-WL(P)-MU1-AW1,00

Declared properties of the product acc. toPN-EN13162+A1:2015-04

Test methodUnit of

measure-ment

Levels or tolerancesClasses of

levels codesValues

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2

Width (class of dimensional tolerance) [%] [-] ± 1,5

Thickness (class of thickness tolerance)

<100 mmPN-EN 823

[mm/%]T3

- 3mm / + 10%≥100 mm [%/mm] - 3% / + 10mm

Squareness Sb PN-EN 824 mm/m [-] ≤ 5

Flatness Smax PN-EN 825 mm [-] ≤ 6

Dimensional stability under specified temperature and relative humidity conditions

PN-EN 1604[%]

DS(70,90)± 1,0 (change of thickness,

length and width)[mm/m] ± 1 (change of flatness)

Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)10 ≥ 10

Tensile strength perpendicular to faces PN-EN 1607 [kPa] TR5 ≥ 5

Short-term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0

Long term water absorption by partial immersion PN-EN 12087 [kg/m2] WL(P) ≤ 3,0

Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1

Weighted sound absorption coefficient PN-EN ISO 3544 [-] AW1,00 1,00

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,035

Reaction to fire PN-EN 13501-1 A to F Euroclass A1

Insulation of external three-layer wall

1 - Mineral render2 - Ceramic hollow-bricks3 - Ventilation gap4 - ISOVENT-M5 - Connector6 - Ceramic hollow bricks7 - Plaster

Dimensions and packaging

Slabs dimensionsNo. of slabs in

a packageSurface covered by

packagePackage volume

No. ofpackages on a

pallet

Mineral wool volume on a

palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3] [pcs] [m3]80

1000 600

3 1,80 0,144 20

2,88100 3 1,80 0,180 16120 2 1,20 0,144 20150 2 1,20 0,180 16200 2 1,20 0,240 12

Apparent density PN-EN 1602 [kg/m3]

80 (for thickness <80mm)

75 (for thickness 80-100mm)

65 (for thickness >100mm)

Thickness [mm]

80 100 120 150 200Thermal resistance RD [m2K/W]

2,25 2,85 3,40 4,25 5,70

Declared thermal resistance RD for respective thicknesses of the product

On customer request there is a possibility of producing plates with other dimensions.

ISOVENT-M slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

ISOVENT-M Mineral wool slabs Façade

VEN

TILA

TED

FA

ÇA

DE

Page 9: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

9

Catalog 2017

Thickness [mm]

80 100 120 150 200Thermal resistance RD [m2K/W]

2,15 2,70 3,20 4,05 5,40

Declared thermal resistance RD for respective thicknesses of the product

Product description:Slabs of mineral wool for thermal, acoustic and fire insulation of:

9 external façade insulated by light-dry method (for instance made of sheet, board, siding),

9 three-layer walls, 9 external walls with stone or glass façade, 9 stud walls, 9 in internal structures of partition walls, 9 three-layer foundation walls, 9 acoustic screens.

Properties: 9 easy in assembly and processing, 9 non-flammable, excellent protection against fire, 9 hydrophobized (do not absorb moisture), 9 they tightly fit in insulated spaces, and therefore

formation of thermal bridges is effectively prevented, 9 during assembly, 9 they are produced from natural raw materials, 9 ensure proper heat comfort and allow walls to breathe, 9 resistant to chemical and biological corrosion, 9 they are not subject to erosion, their durability

exceeds that of plastics.

Technical properties:

Insulation of external wall with glasscladding

1- Glass cladding2- Ventilation gap3- ISOVENT-MW4- Concrete blocks5- Plaster

On customer request there is a possibility of producing plates with other dimensions.

ISOVENT-MW slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

Special features:Slabs are coated with glass veil, which ensures excellent wind insulation.

ISOVENT-MWMW-EN 13162-T3-DS(70,90)-CS(10)10-TR5-WS-WL(P)-MU1-AW1,00

Declared properties of the product acc. toPN-EN13162+A1:2015-04

Test methodUnit of

measure-ment

Levels or tolerancesClasses of

levels codesValues

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2

Width (class of dimensional tolerance) [%] [-] ± 1,5

Thickness (class of thickness tolerance)

<100 mmPN-EN 823

[mm/%]T3

- 3mm / + 10%≥100 mm [%/mm] - 3% / + 10mm

Squareness Sb PN-EN 824 mm/m [-] ≤ 5

Flatness Smax PN-EN 825 mm [-] ≤ 6

Dimensional stability under specified temperature and relative humidity conditions

PN-EN 1604[%]

DS(70,90)± 1,0 (change of thickness,

length and width)[mm/m] ± 1 (change of flatness)

Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)10 ≥ 10

Tensile strength perpendicular to faces PN-EN 1607 [kPa] TR5 ≥ 5

Short-term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0

Long term water absorption by partial immersion PN-EN 12087 [kg/m2] WL(P) ≤ 3,0

Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1

Weighted sound absorption coefficient PN-EN ISO354 [-] AW1,00 1,00

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,037

Reaction to fire PN-EN 13501-1 A to F Euroclass A1

ISOVENT-MW Mineral wool slabs with glass veil Façade

Dimensions and packaging

Slabs dimensionsNo. of slabs

in a packageSurface covered

by packagePackage volume

No. ofpackages on

a pallet

Surface covered by slabs on a

pallet

Mineral wool volume on a

palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3] [pcs] [m2] [m3]80

1000 600

3 1,80 0,144 20 36,00

2,88100 3 1,80 0,180 16 28,80120 2 1,20 0,144 20 24,00150 2 1,20 0,180 16 19,20200 2 1,20 0,240 12 14,40

Apparent density PN-EN 1602 [kg/m3]

80 (for thickness <80mm)

75 (for thickness 80-100mm)

65 (for thickness >100mm)

VEN

TILATED

FAÇ

AD

E

Page 10: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

10

Catalog 2017

Product description: Slabs of mineral wool for thermal, acoustic and fire insulation of:

9 external façade insulated by light-dry method (for instance made of sheet, board, siding),

9 as an acoustic insulation in acoustic screens, 9 external walls using façades panels (e.g. siding), 9 as a thermal insulation in chimney systems.

Properties: 9 light, 9 enhanced mechanical parameters which allows

them to be used in insulation of external walls insulated by light-dry method,

9 non-flammable, excellent protection against fire, 9 elastic, easy adapting to insulated surface, 9 hydrophobized (do not absorb moisture), 9 they are produced from natural raw materials, 9 resistant to chemical and biological corrosion, they are not

subject to errosion, 9 their durability exceeds that of plastics, 9 they ensure proper heat comfort.

Technical properties:

ISOVENTMW-EN 13162-T4-DS(70,90)-CS(10)15-WS-WL(P)-MU1-AW1,00

Declared properties of the product acc. toPN-EN13162+A1:2015-04

Test methodUnit of

measure-ment

Levels or tolerancesClasses of

levels codesValues

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2

Width (class of dimensional tolerance) [%] [-] ± 1,5

Thickness (class of thickness tolerance)

<100 mmPN-EN 823

[mm/%]T4

- 3mm / + 5%≥100 mm [%/mm] - 3% / + 5mm

Squareness Sb PN-EN 824 mm/m [-] ≤ 5

Flatness Smax PN-EN 825 mm [-] ≤ 6

Dimensional stability under specified temperature and relative humidity conditions

PN-EN 1604[%]

DS(70,90)± 1,0 (change of thickness,

length and width)[mm/m] ± 1 (change of flatness)

Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)15 ≥ 15

Short-term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0

Long term water absorption by partial immersion PN-EN 12087 [kg/m2] WL(P) ≤ 3,0

Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1

Weighted sound absorption coefficient PN-EN ISO354 [-] AW1,00 1,00

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,036

Reaction to fire PN-EN 13501-1 A to F Euroclass A1

Insulation of external three-layer wall

1 - Mineral render2 - Ceramic hollow-bricks3 - Ventilation gap4 - ISOVENT5 - Connector6 - Ceramic hollow bricks7 - Plaster

Dimensions and packaging

Slabs dimensionsNo. of slabs

in a packageSurface covered

by packagePackage volume

No. ofpackages

on a pallet

Surface covered by slabs on a pallet

Mineral wool volume on a

palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3] [pcs] [m2] [m3]80

1000 600

3 1,80 0,144 20 36,00

2,88100 3 1,80 0,180 16 28,80150 2 1,20 0,180 16 19,20200 2 1,20 0,240 12 14,40

Apparent density PN-EN 1602 [kg/m3] [-] 90

Thickness [mm]

80 100 150 200Thermal resistance RD [m2K/W]

2,20 2,75 4,15 5,55

Declared thermal resistance RD for respective thicknesses of the product

On customer request there is a possibility of producing plates with other dimensions.

ISOVENT slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

ISOVENT Mineral wool slabs Façade

VEN

TILA

TED

FA

ÇA

DE

Page 11: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

11

Catalog 2017

ISOPANEL-WMW-EN 13162-T3-DS(70,90)-CS(10)15-TR5-WS-MU1

Declared properties of the product acc. toPN-EN13162+A1:2015-04

Test methodUnit of

measure-ment

Levels or tolerancesClasses of

levels codesValues

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2

Width (class of dimensional tolerance) [%] [-] ± 1,5

Thickness (class of thickness tolerance)

<100 mmPN-EN 823

[mm/%]T3

- 3mm / + 10%≥100 mm [%/mm] - 3% / + 10mm

Squareness Sb PN-EN 824 mm/m [-] ≤ 5

Flatness Smax PN-EN 825 mm [-] ≤ 6

Dimensional stability under specified temperature and relative humidity conditions

PN-EN 1604[%]

DS(70,90)± 1,0 (change of thickness,

length and width)[mm/m] ± 1 (change of flatness)

Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)15 ≥ 15

Tensile strength perpendicular to faces PN-EN 1607 [kPa] TR5 ≥ 5

Short-term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0

Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,036

Reaction to fire PN-EN 13501-1 A to F Euroclass A1

Thickness [mm]

50 80 100Thermal resistance RD [m2K/W]

1,35 2,20 2,75

Declared thermal resistance RD for respective thicknesses of the product

Product description:Slabs of mineral wool for thermal, acoustic and fire insulation of:

9 external façade insulated by light-dry method (for instance made of sheet, board, siding),

9 three-layer walls, 9 external walls with stone or glass façade, stud

walls, shell walls, 9 partition walls, 9 three-layer foundation walls, 9 as an acoustic insulation in acoustic screens.

Properties: 9 non-flammable, excellent protection against fire, 9 hydrophobized (do not absorb moisture), 9 easy in assembly and processing, 9 ensure proper acoustic comfort, 9 resistant to chemical and biological corrosion, 9 they are produced from natural raw materials.

Technical properties:

Insulation of external wallwith glass cladding

1 - Glass cladding2 - Ventilation gap3 - ISOPANEL-W4 - Concrete blocks5 - Plaster

Apparent density PN-EN 1602 [kg/m3] [-] 110

On customer request there is a possibility of producing plates with other dimensions.

ISOPANEL-W slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

Dimensions and packagingSlabs dimensions No. of

slabs in a package

Surface covered by package

Package volumeNo. of

packages on a pallet

Surface covered by slabs on a pallet

Mineral wool volume on a

palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3] [pcs] [m2] [m3]50

1000 6006 3,60 0,180 16 57,60

2,8880 3 1,80 0,144 20 36,00100 3 1,80 0,180 16 28,80

ISOPANEL-W Mineral wool slabs with glass veil Façade

Special features:Slabs are coated with glass veil, which ensures excellent wind insulation.

VEN

TILATED

FAÇ

AD

E

Page 12: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

12

Catalog 2017

ETIC

S

Product description: Slabs of mineral wool for thermal, acoustic and fire insulation of:

9 external walls insulated by light-wet method in so called External Insulation Composite System (ETICS).

Properties: 9 excellent mechanical parameters and enhanced

physical parameters, 9 non-flammable, excellent protection against fire, 9 hydrophobized (do not absorb moisture), 9 easy in assembly and processing, 9 excellent thermal conductivity, which provides a proper

comfort of insulated rooms.

Technical properties:

Insulation of external wall by light-wet method

1 - Adhesive mortar2 - ISOFAS/ISOFAS-SE3 - Fastener4 - Reinforcing mortar5 - Reinforcing fiberglass6 - Primer7 - Mineral render8 - Masonry paint9 - Starter track

ISOFASISOFAS-SE

ISOFAS 50÷99mm ISOFAS-SE 100÷200mmMW-EN 13162-T4-

DS(70,90)-CS(10)20-TR10-WS-WL(P)-MU1-

AW1,00

MW-EN 13162-T5-DS(70,90)-CS(10)30-

TR10-WS-WL(P)-MU1-AW1,00

Declared properties of the product acc. toPN-EN13162+A1:2015-04

Test methodUnit of

measurement

Levels or tolerancesClasses

of levels codes

ValuesClasses of

levels codesValues

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2 [-] ± 2

Width (class of dimensional tolerance) [%] [-] ± 1,5 [-] ± 1,5

Thickness (class of thickness tolerance)

<100 mmPN-EN 823

[mm/%]T4

- 3mm / + 5%T5

-≥100 mm [%/mm] -

- 1% / + 3mm

Squareness Sb PN-EN 824 mm/m [-] ≤ 5 [-] ≤ 5

Flatness Smax PN-EN 825 mm [-] ≤ 6 [-] ≤ 6

Dimensional stability under specified temperature and relative humidity conditions

PN-EN 1604[%]

DS(70,90)

± 1,0 (change of thickness, length and

width) DS(70,90)

± 1,0 (change of thickness, length and

width)

[mm/m]± 1 (change of

flatness)± 1 (change of flatness)

Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)20 ≥ 20 CS(10)30 ≥ 30

Tensile strength perpendicular to faces PN-EN 1607 [kPa] TR10 ≥ 10 TR10 ≥ 10

Short-term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0 WS ≤ 1,0

Long term water absorption by partial immersion PN-EN 12087 [kg/m2] WL(P) ≤ 3,0 WL(P) ≤ 3,0

Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1 MU1 ≤ 1

Weighted sound absorption coefficient PN-EN ISO354 [-] AW1,00 1,00 AW1,00 1,00

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,036 [-] ≤ 0,036

Reaction to fire PN-EN 13501-1 A to F Euroclass A1 Euroclass A1

Dimensions and packaging

Slabs dimensionsNo. of slabs

in a packageSurface covered

by packagePackage volume

No. ofpackages

on a pallet

Surface covered by slabs on a pallet

Mineral wool volume on a

palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3] [pcs] [m2] [m3]50

1000 600

6 3,60 0,180 16 57,60 2,88060 5 3,00 0,180 16 48,00 2,88080 3 1,80 0,144 20 36,00 2,880

100 3 1,80 0,180 16 28,80 2,880120 2 1,20 0,144 20 24,00 2,880140 2 1,20 0,168 16 19,20 2,688150 2 1,20 0,180 16 19,20 2,880160 2 1,20 0,192 12+16 33,60 5,376180 2 1,20 0,216 12 14,40 2,592200 2 1,20 0,240 12 14,40 2,880

Apparent density PN-EN 1602 [kg/m3] [-] 100

Thickness [mm]

50 60 80 100 120 140 150 160 180 200Thermal resistance RD [m2K/W]

1,35 1,65 2,20 2,75 3,30 3,85 4,15 4,40 5,00 5,55

Declared thermal resistance RD for respective thicknesses of the product

On customer request there is a possibility of producing plates with other dimensions.

ISOFAS / ISOFAS-SE slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

ISOFAS ISOFAS-SEMineral wool slabs Façade

Page 13: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

13

Catalog 2017

Product description: Slabs of mineral wool for thermal, acoustic and fire insulation of:

9 external walls insulated by light-wet method in so called External Insulation Composite System (ETICS).

Properties: 9 excellent mechanical parameters and enhanced

physical parameters, 9 non-flammable, excellent protection against fire, 9 hydrophobized (do not absorb moisture), 9 easy in assembly and processing, 9 excellent thermal conductivity, which provides a proper

comfort of insulated rooms.

Technical properties:

Insulation of external wall by light-wet method

1 - Adhesive mortar2 - ISOFAS-C1/ISOFAS-C23 - Fastener4 - Reinforcing mortar5 - Reinforcing fiberglass6 - Primer7 - Mineral render8 - Masonry paint9 - Starter track

Dimensions and packaging

Slabs dimensionsNo. of slabs

in a packageSurface covered

by packagePackage volume

No. ofpackages

on a pallet

Surface covered by slabs on a pallet

Mineral wool volume on a

palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3] [pcs] [m2] [m3]50

1000 600

6 3,60 0,180 16 57,60 2,88060 5 3,00 0,180 16 48,00 2,88080 3 1,80 0,144 20 36,00 2,880

100 3 1,80 0,180 16 28,80 2,880120 2 1,20 0,144 20 24,00 2,880140 2 1,20 0,168 16 19,20 2,688150 2 1,20 0,180 16 19,20 2,880160 2 1,20 0,192 12+16 33,60 5,376180 2 1,20 0,216 12 14,40 2,592200 2 1,20 0,240 12 14,40 2,880

Apparent density PN-EN 1602 [kg/m3] [-] 100

Thickness [mm]

50 60 80 100 120 140 150 160 180 200Thermal resistance RD [m2K/W]

1,35 1,65 2,20 2,75 3,30 3,85 4,15 4,40 5,00 5,55

Declared thermal resistance RD for respective thicknesses of the product

On customer request there is a possibility of producing plates with other dimensions.

ISOFAS-C1 / ISOFAS-C2 slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

ISOFAS-C1ISOFAS-C2Mineral wool slabs Façade

New

• Isofas-C1; coated on one side with primer• Isofas-C2; coated on both sides with primer

ISOFAS-C1ISOFAS-C2

50÷99mm 100÷200mmMW-EN 13162-T4-

DS(70,90)-CS(10)20-TR10-WS-WL(P)-MU1-

AW1,00

MW-EN 13162-T5-DS(70,90)-CS(10)30-

TR10-WS-WL(P)-MU1-AW1,00

Declared properties of the product acc. toPN-EN13162+A1:2015-04

Test methodUnit of

measurement

Levels or tolerancesClasses

of levels codes

ValuesClasses of

levels codesValues

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2 [-] ± 2

Width (class of dimensional tolerance) [%] [-] ± 1,5 [-] ± 1,5

Thickness (class of thickness tolerance)

<100 mmPN-EN 823

[mm/%]T4

- 3mm / + 5%T5

-≥100 mm [%/mm] -

- 1% / + 3mm

Squareness Sb PN-EN 824 mm/m [-] ≤ 5 [-] ≤ 5

Flatness Smax PN-EN 825 mm [-] ≤ 6 [-] ≤ 6

Dimensional stability under specified temperature and relative humidity conditions

PN-EN 1604[%]

DS(70,90)

± 1,0 (change of thickness, length and

width) DS(70,90)

± 1,0 (change of thickness, length and

width)

[mm/m]± 1 (change of

flatness)± 1 (change of flatness)

Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)20 ≥ 20 CS(10)30 ≥ 30

Tensile strength perpendicular to faces PN-EN 1607 [kPa] TR10 ≥ 10 TR10 ≥ 10

Short-term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0 WS ≤ 1,0

Long term water absorption by partial immersion PN-EN 12087 [kg/m2] WL(P) ≤ 3,0 WL(P) ≤ 3,0

Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1 MU1 ≤ 1

Weighted sound absorption coefficient PN-EN ISO354 [-] AW1,00 1,00 AW1,00 1,00

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,036 [-] ≤ 0,036

Reaction to fire PN-EN 13501-1 A to F Euroclass A1 Euroclass A1

ETICS

Page 14: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

14

Catalog 2017

Thickness [mm]

30 40 50 60 80 100 120 140 150 160Thermal resistance RD [m2K/W]

0,80 1,10 1,35 1,65 2,20 2,75 3,30 3,85 4,15 4,40

Declared thermal resistance RD for respective thicknesses of the product

Properties: 9 excellent mechanical parameters and enhanced

physical parameters, 9 non-flammable, excellent protection against fire, 9 hydrophobized (do not absorb moisture), 9 easy in assembly and processing, 9 ensure proper heat comfort.

Technical properties:

Insulation of external wall by light-wetmethod

1 - Adhesive mortar2 - ISOPANEL/ISOPANEL-SE3 - Fastener4 - Reinforcing mortar5 - Reinforcing fiberglass6 - Primer7 - Mineral render8 - Masonry paint9 - Starter track

Apparent density PN-EN 1602 [kg/m3] [-] 110

On customer request there is a possibility of producing plates with other dimensions.ISOPANEL/ISOPANEL-SE slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

Dimensions and packaging

Slabs dimensionsNo. of slabs in a

package

Surface covered by package

Package volume

No. ofpackages on a

pallet

Surface covered by slabs on a pallet

Mineral wool volume on a

palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3] [pcs] [m2] [m3]30

1000 600

10 6,0 0,180 12+16 168,0 5,04040 6 3,6 0,144 16+20 129,6 5,18450 6 3,6 0,180 16 57,6 2,88060 5 3,0 0,180 16 48,0 2,88080 3 1,8 0,144 20 36,0 2,880

100 3 1,8 0,180 16 28,8 2,880120 2 1,2 0,144 20 24,0 2,880140 2 1,2 0,168 16 19,2 2,688150 2 1,2 0,180 16 19,2 2,880160 2 1,2 0,192 12+16 33,6 5,376

Product description: Slabs of mineral wool for thermal, acoustic and fire insulation of:

9 external walls insulated by light-wet method in so called External Insulation Composite System (ETICS),

9 as an acoustic insulation in acoustic screens, 9 as a thermal insulation in chimney systems.

ISOPANEL ISOPANEL-SE Mineral wool slabs Façade

ISOPANELISOPANEL-SE

ISOPANEL 30÷49 mm ISOPANEL-SE 50÷200 mm

MW-EN 13162-T3-DS(70,90)-CS(10)15-

TR7,5-WS-WL(P)-MU1

MW-EN 13162-T5-DS(70,90)-CS(10)30-TR10-PL(5)250-WS-

WL(P)-MU1

Declared properties of the product acc. toPN-EN13162+A1:2015-04

Test methodUnit of

measurement

Levels or tolerancesClasses

of levels codes

ValuesClasses of

levels codesValues

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2 [-] ± 2

Width (class of dimensional tolerance) [%] [-] ± 1,5 [-] ± 1,5

Thickness (class of thickness tolerance)

<100 mmPN-EN 823

[mm/%]T3

- 3mm / + 10%

T5-1mm/+3%

≥100 mm [%/mm] -- 1% /

+ 3mm

Squareness Sb PN-EN 824 mm/m [-] ≤ 5 [-] ≤ 5

Flatness Smax PN-EN 825 mm [-] ≤ 6 [-] ≤ 6

Dimensional stability under specified tempera-ture and relative humidity conditions

PN-EN 1604[%]

DS(70,90)

± 1,0 (change of thickness, length and

width) DS(70,90)

± 1,0 (change of thickness, length and

width)

[mm/m]± 1 (change of

flatness)± 1 (change of

flatness)

Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)15 ≥ 15 CS(10)30 ≥ 30

Tensile strength perpendicular to faces PN-EN 1607 [kPa] TR7,5 ≥ 7,5 TR10 ≥ 10

Point load for 5 mm deformation PN-EN 12430 [N] [-] PL(5)250 ≥ 250

Short-term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0 WS ≤ 1,0

Long term water absorption by partial immersion PN-EN 12087 [kg/m2] WL(P) ≤ 3,0 WL(P) ≤ 3,0

Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1 MU1 ≤ 1

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,036 [-] ≤ 0,036

Reaction to fire PN-EN 13501-1 A to F Euroclass A1 Euroclass A1

ETIC

S

Page 15: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

15

Catalog 2017

Product description: Lamella slabs of mineral wool for thermal, acoustic and fire insulation of:

9 external walls insulated by light-wet method in so called External Insulation Composite System (ETICS),

9 as an acoustic insulation in acoustic screens, 9 to expansion joint.

Properties: 9 high insulation properties, 9 high thermal comfort of insulated rooms, 9 high mechanical parameters, 9 effectiveness in avoiding formation of thermal, 9 bridges ensured by staggered assembly of plates, 9 non-flammable, (they increase fire resistance

class of the building), 9 low diffusion resistance ensuring

„free breathing” of partitions, preventing their dampness easy in assembly and cutting,

9 produced from natural raw materials, 9 resistant to chemical and biological corrosion.

Technical properties:

Insulation of external wall by light-wet method

1 - Adhesive mortar 2 - ISOFAS-P 3 - Fastener 4 - Reinforcing mortar 5 - Reinforcing fiberglass 6 - Primer 7 - Mineral render 8 - Masonry paint 9 - Starter track

Dimensions and packagingSlabs dimensions

No. of slabs in a package

Surface covered by package

Package volume

No. ofpackages

on a pallet

Surface covered by slabs on a pallet

Mineral wool volume on a palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3] [pcs] [m2] [m3]20

1000 600

15 9,00 0,180 16+12 252,00 5,04030 19 6,00 0,180 16+12 168,00 5,04040 6 3,60 0,144 20+16 129,60 5,18450 6 3,60 0,180 16 57,60 2,88080 3 1,80 0,144 20 36,00 2,880

100 3 1,80 0,180 16 28,80 2,880

Apparent density PN-EN 1602 [kg/m3] [-] 130

Thickness [mm]20 30 40 50 80 100

Thermal resistance RD [m2K/W]

0,50 0,75 1,05 1,30 2,10 2,60

Declared thermal resistance RD for respective thicknesses of the product

ISOFAS-P Mineral wool lamella slabs Façade

On customer request there is a possibility of producing plates with other dimensions.

ISOFAS-P slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

ISOFAS-P

20÷49 mm 50÷99 mm 100÷200 mm

MW-EN 13162-T3-DS(70,90)-CS(10)20-TR10-WS-WL(P)-MU1

MW-EN 13162-T4-DS(70,90)-CS(10)40-

TR15-WS-WL(P)-MU1

MW-EN 13162-T4-DS(70,90)-

CS(10)50-TR15-WS-WL(P)-MU1

Declared properties of the product acc. to

PN-EN13162+A1:2015-04Test method

Unit ofmeasure-

ment

Levels or tolerancesCodes ofclasses

or levelsValues

Codes ofclasses

or levelsValues

Codes ofclasses

or levelsValues

Length (class of dimensional tolerance) PN-EN 822

[%] [-] ± 2 [-] ± 2 [-] ± 2

Width (class of dimensional tolerance)

[%] [-] ± 1,5 [-] ± 1,5 [-] ± 1,5

Thickness (class of thick-ness tolerance)

<100 mmPN-EN 823

[mm/%]T3

-3 mm /+10 % T4

-3mm /+5%T4

[-]

≥100 mm [%/mm] [-] - -3% /+5 mm

Squareness Sb PN-EN 824 mm/m [-] ≤ 5 [-] ≤ 5 [-] ≤ 5Flatness Smax PN-EN 825 mm [-] ≤ 6 [-] ≤ 6 [-] ≤ 6

Dimensional stability under specified temperature and relative humidity conditions

PN-EN 1604[%]

DS(70,90)

± 1,0(zmianagrubości,długości

i szerokości)DS(70,90)

± 1,0(zmianagrubości,długości

i szerokości)DS(70,90)

± 1,0(zmianagrubości,długości

i szerokości)

[mm/m] ± 1(zmianapłaskości)

± 1(zmianapłaskości)

± 1(zmianapłaskości)

Compressive stress at 10% deformation

PN-EN 826 [kPa] CS(10)20 ≥ 20 CS(10)40 ≥ 40 CS(10)50 ≥ 50

Tensile strength perpendicular to faces

PN-EN 1607 [kPa] TR10 ≥ 10 TR15 ≥ 15 TR15 ≥ 15

Short-term water absorption

PN-EN 1609 [kg/m2] WS ≤ 1,0 WS ≤ 1,0 WS ≤ 1,0

Long term water absorption by partial immersion

PN-EN 12087 [-] WL(P) ≤ 3,0 WL(P) ≤ 3,0 WL(P) ≤ 3,0

Water vapour diffusion resistance factor

PN-EN 12086 [kg/m2] MU1 ≤ 1 MU1 ≤ 1 MU1 ≤ 1

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,038 [-] ≤ 0,038 [-] ≤ 0,038

Reaction to fire PN-EN 13501-1 A to F Euroclass A1 Euroclass A1 Euroclass A1

ETICS

Page 16: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

16

Catalog 2017

Thickness [mm]

50 80 100 120 150 200 250 300Thermal resistance RD [m2K/W]

1,20 1,95 2,40 2,90 3,65 4,85 6,05 7,30

Declared thermal resistance RD for respective thicknesses of the product

Product description: Lamella slabs of mineral wool as thermal, acoustic and fire insulation:

9 in light-wet method (ETICS) of external walls, 9 concrete soffits over unheated spaces like garages.

Properties: 9 high insulation properties, 9 high thermal comfort of insulated rooms, 9 high mechanical parameters, 9 non-flammable (they increase fire resistance class

of the building), 9 low diffusion resistance ensuring „free breathing”

of partitions, preventing their dampness, 9 easy to cut and assemble, 9 produced from natural raw materials, 9 versatile in use and easy to fit in even with

curved insulated surfaces.

Technical properties:

Insulation of external wall by light-wet method with the use of lamella

1 - Adhesive mortar2 - ISOFAS-LM3 - Fastener4 - Reinforcing mortar5 - Reinforcing fiberglass6 - Primer7 - Mineral render8 - Masonry paint9 - Starter track

Apparent densityPN-EN 1602

[kg/m3] [-] 90

Dimensions and packaging

Slabs dimensionsNo. of slabs in a

packageSurface covered by

packagePackage volume

No. ofpackages on

a pallet

Mineral wool volume on a palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3] [pcs] [m3]50

1200 200

8 1,92 0,0960 60 5,7680 6 1,44 0,1152 50 5,76

100 4 0,96 0,0960 60 5,76120 4 0,96 0,1152 50 5,76150 4 0,96 0,1440 40 5,76200 4 0,96 0,1920 30 5,76250 2 0,48 0,1200 50 6,00300 2 0,48 0,1440 40 5,76

ISOFAS-LM Mineral wool lamella slabs Façade

On customer request there is a possibility of producing plates with other dimensions.

ISOFAS-LM slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

ISOFAS-LM

50÷200 mm 210÷300 mm

MW-EN 13162-T5-DS(70,90)-CS(10)60-TR90-WS-WL(P)-MU1

MW-EN 13162-T5- DS(70,90)-CS(10)60- TR80-WS-WL(P)-MU1

Declared properties of the product acc. to PN-EN13162+A1:2015-04

Test method

Unit ofmeas-

urement

Levels or tolerances

Classes of levels codes

ValuesClasses of

levels codesValues

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2 [-] ± 2Width (class of dimensional tolerance) [%] [-] ± 1,5 [-] ± 1,5

Thickness (class of thickness tolerance)

<100 mmPN-EN 823

[mm/mm]T5

-1mm/+3mmT5

-

[%/mm] -1%/+3 mm -1%/+3mm≥100 mm

Squareness Sb PN-EN 824 mm/m [-] ≤ 5 [-] ≤ 5

Flatness Smax PN-EN 825 mm [-] ≤ 6 [-] ≤ 6

Dimensional stability under specified tempera-ture and relative humidity conditions

PN-EN 1604[%]

DS(70,90)

± 1,0 (change of thickness, length and

width)DS(70,90)

± 1,0 (change of thickness, length and

width)

[mm/m]± 1 (change of

flatness)± 1 (change of

flatness)

Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)60 ≥ 60 CS(10)60 ≥ 60

Tensile strength perpendicular to faces PN-EN 1607 [kPa] TR90 ≥ 90 TR80 ≥ 80

Short-term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0 WS ≤ 1,0

Long term water absorption by partial immersion

PN-EN 12087 [kg/m2] WL(P) ≤ 3,0 WL(P) ≤ 3,0

Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1 MU1 ≤ 1

Thermal conductivity λDPN-EN 12667 [W/mK] [-] ≤ 0,041 [-] ≤ 0,041

Reaction to fire PN-EN 13501-1 A to F Euroclass A1 Euroclass A1

ETIC

S

Page 17: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

17

Catalog 2017

Properties: 9 produced from natural raw materials, 9 high insulation properties, 9 high thermal comfort of insulated rooms, 9 high mechanical parameters, 9 non-flammable, (they increase fire resistance

class of the building), 9 easy in assembly and cutting.

Technical properties:

1 - Concrete soffit2 - Adhesive mortar3 - ISOFAS-LM bevelled4 - Primer5 - Spray layer

Dimensions and packaging

Apparent density PN-EN 1602 [kg/m3] [-] 90

ISOFAS-LM (bevelled) Mineral wool lamella slabs Garage sysytems / soffit protection

Thickness [mm]

50 80 100 120 150 200Thermal resistance RD [m2K/W]

1,20 1,95 2,40 2,90 3,65 4,85

Slabs dimensionsNo. of slabs on a pallet

Surface covered by slabs on a pallet

Mineral wool volume on a palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3]50

1200 200

240 57,60

2,88

80 150 36,00100 120 28,80120 100 24,00150 80 19,20200 60 14,40

Declared thermal resistance RD for respective thicknesses of the product

Dimensions and packaging1 2

4

5

3

Thermal insulation of concrete soffits

Product description:Bevelled slabs of mineral wool ISOFAS-LM designed for:

9 insulation of concrete soffit over unheated spaces like garages.

On customer request there is a possibility of producing plates with other dimensions.

ISOFAS-LM slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

ISOFAS-LM bevelledMW-EN 13162-T5-DS(70,90)-CS(10)60-TR90-WS-WL(P)-MU1

Declared properties of the product acc. to PN-EN13162+A1:2015-04 Test method

Unit ofmeasure-

ment

Levels or tolerances

Classes of levels codes

Values

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2

Width (class of dimensional tolerance) [%] [-] ± 1,5

Thickness (class of thickness tolerance)

<100 mmPN-EN 823

[mm/mm]T5

- 1mm/ + 3mm≥100 mm [%/mm] - 1%/ + 3mm

Squareness Sb PN-EN 824 [mm/m] [-] ≤ 5

Flatness Smax PN-EN 825 [mm] [-] ≤ 6

Dimensional stability under specified temperature and relative humidity conditions

PN-EN 1604[%]

DS(70,90)± 1,0 (change of thickness,

length and width)[mm/m] ± 1 (change of flatness)

Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)60 ≥ 60

Tensile strength perpendicular to faces PN-EN 1607 [kPa] TR90 ≥ 90

Short-term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0

Long term water absorption by partial immersion PN-EN 12087 [kg/m2] WL(P) ≤ 3,0

Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,041

Reaction to fire PN-EN 13501-1 A to F Euroclass A1

GA

RA

GE SY

STEMSO

FFIT PR

OTEC

TION

Page 18: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

18

Catalog 2017

Properties: 9 produced from natural raw materials, 9 high insulation properties, 9 high thermal comfort of insulated rooms, 9 high mechanical parameters, 9 non-flammable, (they increase fire resistance

class of the building), 9 easy in assembly and cutting.

Technical properties:

Dimensions and packaging

Declared thermal resistance RD for respective thicknesses of the product

ISOLAM-G Mineral wool lamella slabs Garage systems / soffit protection

Thickness [mm]

50 80 100 120 150 200Thermal resistance RD [m2K/W]

1,35 2,15 2,70 3,20 4,05 5,40

Slabs dimensionsNo. of slabs on a pallet

Surface covered by slabs on a pallet

Mineral wool volume on a palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3]50

1000 200

288 57,60

2,88

80 180 36,00100 144 28,80120 120 24,00150 96 19,20200 72 14,40

1 - Concrete soffit2 - Adhesive mortar3 - ISOLAM-G4 - Plaster

1

2

3

4

Thermal insulation of concrete soffits

Product description:Bevelled lamella slabs of mineral wool ISOFAS-LMG (one-site coated) designed for:

9 insulation of concrete soffit over unheated spaces like garages.

On customer request there is a possibility of producing plates with other dimensions.

ISOLAM-G slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

ISOLAM-G MW-EN 13162-T5-DS(70,90)-CS(10)15-TR7,5-WS-MU1

Declared properties of the product acc. to PN-EN13162+A1:2015-04 Test method

Unit ofmeasure-

ment

Levels or tolerancesClasses of levels

codesValues

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2

Width (class of dimensional tolerance) [%] [-] ± 1,5

Thickness (class of thickness tolerance)

PN-EN 823[mm/mm]

T5- 1mm/ + 3mm

[%/mm] - 1%/ + 3mm

Squareness Sb PN-EN 824 [mm/m] [-] ≤ 5

Flatness Smax PN-EN 825 [mm] [-] ≤ 6

Dimensional stability under specified temperature and relative humidity conditions

PN-EN 1604[%]

DS(70,90)± 1,0 (change of thickness,

length and width)[mm/m] ± 1 (change of flatness)

Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)15 ≥ 15

Tensile strength perpendicular to faces PN-EN 1607 [kPa] TR7,5 ≥ 7,5

Short-term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0

Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤0,037

Reaction to fire PN-EN 13501-1 A to F Euroclass A1

New

Apparent density PN-EN 1602 [kg/m3] [-] 80

GA

RA

GE

SYST

EMSO

FFIT

PR

OTE

CTI

ON

Page 19: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

19

Catalog 2017

Properties: 9 produced from natural raw materials, 9 high insulation properties, 9 high thermal comfort of insulated rooms, 9 high mechanical parameters, 9 non-flammable, (they increase fire resistance

class of the building), 9 easy in assembly and cutting.

Technical properties:

Dimensions and packaging

Declared thermal resistance RD for respective thicknesses of the product

ISOFAS-LMG Mineral wool lamella slabs Garage systems / soffit protection

Thickness [mm]

50 80 100 120 150 200Thermal resistance RD [m2K/W]

1,20 1,95 2,40 2,90 3,65 4,85

Slabs dimensionsNo. of slabs on a pallet

Surface covered by slabs on a pallet

Mineral wool volume on a palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3]50

1200 200

240 57,60

2,88

80 150 36,00100 120 28,80120 100 24,00150 80 19,20200 60 14,40

1 - Concrete soffit2 - Adhesive mortar3 - ISOFAS-LMG4 - Plaster

1

2

3

4

Thermal insulation of concrete soffits

Apparent density PN-EN 1602 [kg/m3] [-] 80

Product description:Bevelled lamella slabs of mineral wool ISOFAS-LMG (one-site coated) designed for:

9 insulation of concrete soffit over unheated spaces like garages.

On customer request there is a possibility of producing plates with other dimensions.

ISOFAS-LMG slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

ISOFAS-LMGMW-EN 13162-T5-CS(Y)30-TR60-WS-MU1

Declared properties of the product acc. to PN-EN13162+A1:2015-04

Test methodUnit of

measure-ment

Levels or tolerancesClasses

of levels codes

Values

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2

Width (class of dimensional tolerance) [%] [-] ± 1,5Thickness (class of thickness tolerance)

<100 mmPN-EN 823

[mm/mm]T5

-1mm/+3mm≥100 mm [%/mm] -1%/+3 mm

Squareness Sb PN-EN 824 mm/m [-] ≤ 5

Flatness Smax PN-EN 825 mm [-] ≤ 6

Compressive strength PN-EN 826 [kPa] CS(Y)30 ≥ 30

Tensile strength perpendicular to faces PN-EN 1607 [kPa] TR60 ≥ 60

Short-term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0

Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,041

Reaction to fire PN-EN 13501-1 A to F Euroclass A1

GA

RA

GE SY

STEMSO

FFIT PR

OTEC

TION

Page 20: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

20

Catalog 2017

FLA

T R

OO

F

Product description:Slabs of mineral wool for thermal, acoustic and fireinsulation of:

9 non-ventilated flat roofs with concerete or steel structure as base layer in two-layer ISODACH insulation system together with a top layer ISOROOF-T,

9 floor insulation under base coat (normally loaded).

Properties: 9 versatility of use with other top covering layers, 9 excellent mechanical parameters and enhanced

physical parameters, 9 non-flammable, excellent protection against fire, 9 hydrophobized (do not absorb moisture), 9 easy in assembly and processing, 9 using together with top slab allows to avoid

formation of thermal bridges, 9 ensure proper heat comfort.

Technical properties:

Apparent density PN-EN 1602 [kg/m3] [-] 110

Dimensions and packaging

Thickness [mm]

50 60 80 110 120 160Thermal resistance RD [m2K/W]

1,35 1,65 2,20 3,05 3,30 4,40

Declared thermal resistance RD for respective thicknesses of the product

On customer request there is a possibility of producing plates with other dimensions.

ISOPANEL-D slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

ISOPANEL-D Mineral wool slabsFlat roofing - ISODACH System

Slabs dimensions No. of slabs in a package

Surface covered by package

Package volume

No. ofpackages

on a pallet

No. of slabs on a pallet

Surface covered by by slabs on a

pallet

Mineral wool volume on a

palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3] [pcs] [pcs] [m2] [m3]

50 1000 600 6 3,6 0,18 16 57,62,8802000 1200 24

80 1000 600 3 1,8 0,144 20 362000 1200 15110 2000 1200 11 26,40 2,904120 2000 1200 10 24,00 2,880160 2000 1200 7 16,80 2,688

Insulation of flat roofin two-layers ISODACH system

1 - Concrete slab 2 - Vapour insulation3 - ISOPANEL-D4 - ISOROOF-T5 - Waterproof/bitumen membrane

12

45

3

ISOPANEL-DMW-EN 13162-T4-DS(70,90)-CS(10)30-TR10-PL(5)250-WS-WL(P)-MU1

Declared properties of the product acc. toPN-EN13162+A1:2015-04

Test methodUnit of

measure-ment

Levels or tolerancesClasses of

levels codesValues

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2

Width (class of dimensional tolerance) [%] [-] ± 1,5

Thickness (class of thickness tolerance)

<100 mmPN-EN 823

[mm/%]T4

- 3mm / + 5%

≥100 mm [%/mm] - 3% / + 5mm

Squareness Sb PN-EN 824 mm/m [-] ≤ 5

Flatness Smax PN-EN 825 mm [-] ≤ 6

Dimensional stability under specified temperature and relative humidity conditions

PN-EN 1604[%]

DS(70,90)± 1,0 (change of thickness,

length and width)[mm/m] ± 1 (change of flatness)

Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)30 ≥ 30

Tensile strength perpendicular to faces PN-EN 1607 [kPa] TR10 ≥ 10

Point load for 5 mm deformation PN-EN 12430 [N] PL(5)250 ≥ 250

Short-term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0

Long term water absorption by partial immersion PN-EN 12087 [kg/m2] WL(P) ≤ 3,0

Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,036

Reaction to fire PN-EN 13501-1 A to F Euroclass A1

Page 21: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

21

Catalog 2017

Product description:Slabs of mineral wool for thermal, acoustic and fireinsulation of:

9 non-ventilated flat roofs with concrete or steel structure as a top layer in two-layer ISODACH insulation system together with base coat layer ISOPANEL - D.

Properties: 9 versatility of use with other base coat insulation slabs, 9 excellent mechanical parameters and enhanced

physical parameters, 9 non-flammable, excellent protection against fire, 9 hydrophobized (do not absorb moisture), 9 easy in assembly and processing, 9 using together with base coat slab allows to

avoid formation of thermal bridges, 9 ensure proper heat comfort.

Technical properties:

Insulation of flat roofin two-layers ISODACH System

1 - Concrete slab 2 - Vapour insulation3 - ISOPANEL-D4 - ISOROOF-T5 - Waterproof/bitumen membrane

Dimensions and packaging

Slabs dimensionsNo. of slabs on a pallet

Surface covered by slabs on a pallet

Mineral wool volume on a palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3]40 2000 1200 28 67,20 2,688

Thickness [mm]

40Thermal resistance RD [m2K/W]

1,00

Declared thermal resistance RD for respective thicknesses of the product

On customer request there is a possibility of producing plates with other dimensions.

ISOROOF- T slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

ISOROOF-T Mineral wool slabsFlat roofing - ISODACH System

Apparent density PN-EN 1602 [kg/m3] [-] 175

12

45

3

ISOROOF -TMW-EN 13162-T3-DS(70,90)-CS(10)60-TR15-PL(5)700-WS-WL(P)-MU1

Declared properties of the product acc. toPN-EN13162+A1:2015-04

Test methodUnit of

measure-ment

Levels or tolerancesClasses of

levels codesValues

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2

Width (class of dimensional tolerance) [%] [-] ± 1,5

Thickness (class of thickness tolerance)

PN-EN 823 [mm/%] T3 - 3mm / + 10%

Squareness Sb PN-EN 824 mm/m [-] ≤ 5

Flatness Smax PN-EN 825 mm [-] ≤ 6

Dimensional stability under specified temperature and relative humidity conditions

PN-EN 1604[%]

DS(70,90)± 1,0 (change of thickness,

length and width)[mm/m] ± 1 (change of flatness)

Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)60 ≥ 60

Tensile strength perpendicular to faces PN-EN 1607 [kPa] TR15 ≥ 15

Point load for 5 mm deformation PN-EN 12430 [N] PL(5)700 ≥700

Poziom krótkotrwałej nasiąkliwości wodą PN-EN 1609 [kg/m2] WS ≤ 1,0

Long term water absorption by partial immersion PN-EN 12087 [kg/m2] WL(P) ≤ 3,0

Long term water absorption by partial immersion PN-EN 12086 [-] MU1 ≤ 1

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,039

Reaction to fire PN-EN 13501-1 A to F Euroclass A1

FLAT R

OO

F

Page 22: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

22

Catalog 2017

Product description:Slabs of mineral wool for thermal, acoustic and fireinsulation of:

9 non-ventilated flat roofs with concrete or steel structure in single-layer system ISODACH MONO,

9 floor insulation under floor base coat (normally loaded).

Properties: 9 hard, 9 enhanced mechanical parameters, 9 easy in assembly and processing, 9 non-flammable, excellent protection against fire, 9 hydrophobized (do not absorb moisture), 9 produced from natural raw materials, 9 ensure proper heat comfort and allow walls to breathe, 9 resistant to chemical and biological corrosion, 9 they are not subject to erosion, their durability

exceeds that of plastics.

Technical properties:

Insulation of flat roofin ISODACH MONO System

1 - Concrete slab 2 - Vapour insulation3 - ISOROOF-B4 - Waterproof/bitumen membrane

Apparent density PN-EN 1602 [kg/m3] [-] 130

Thickness [mm]

50 80 100Thermal resistance RD [m2K/W]

1,30 2,10 2,60

Declared thermal resistance RD for respective thicknesses of the product

Dimensions and packagingSlabs dimensions

No. of slabs in a package

Surface covered by package

Package volume

No. ofpackages

on a pallet

No. of slabs on a pallet

Surface covered by by slabs on a

pallet

Mineral wool volume on a

palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3] [pcs] [pcs] [m2] [m3]

501000 600 6 3,60 0,180 16

57,60

2,88

2000 1200 24

801000 600 3 1,80 0,144 20

36,002000 1200 15

1001000 600 3 1,80 0,180 16

28,802000 1200 12

On customer request there is a possibility of producing plates with other dimensions.

ISOROOF-B slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

ISOROOF-B Mineral wool slabsFlat roofing - ISODACH MONO

ISOROOF-BMW-EN 13162-T3-DS(70,90)-CS(10)40-TR7,5-PL(5)400-WS-WL(P)-MU1

Declared properties of the product acc. to PN-EN13162+A1:2015-04

Test methodUnit of

measure-ment

Levels or tolerancesClasses of

levels codesValues

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2

Width (class of dimensional tolerance) [%] [-] ±1,5

Thickness (class of thickness tolerance)

<100 mmPN-EN 823

[mm/%]T3

- 3mm / + 10%

≥100 mm [%/mm] - 3% / + 10mm

Squareness Sb PN-EN 824 mm/m [-] ≤ 5

Flatness Smax PN-EN 825 mm [-] ≤ 6

Dimensional stability under specified temperature and relative humidity conditions

PN-EN 1604[%]

DS(70,90)± 1,0 (change of thickness,

length and width)[mm/m] ± 1 (change of flatness)

Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)40 ≥ 40

Tensile strength perpendicular to faces PN-EN 1607 [kPa] TR7,5 ≥ 7,5

Point load for 5 mm deformation PN-EN 12430 [N] PL(5)400 ≥ 400

Short-term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0

Long term water absorption by partial immersion PN-EN 12087 [kg/m2] WL(P) ≤ 3,0

Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,038

Reaction to fire PN-EN 13501-1 A to F Euroclass A1

FLA

T R

OO

F

Page 23: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

23

Catalog 2017

On customer request there is a possibility of producing plates with other dimensions.

ISOROOF-H slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

Product description:Slabs of mineral wool for thermal, acoustic and fireinsulation of:

9 non-ventilated flat roofs with concrete or steel structure in single-layer system ISODACH MONO,

9 floor insulation under floor base coat (normally loaded).

Properties: 9 hard, 9 enhanced mechanical parameters, 9 easy in assembly and processing, 9 non-flammable, excellent protection against fire, 9 hydrophobized (do not absorb moisture), 9 produced from natural raw materials, 9 ensure proper heat comfort and allow walls to breathe, 9 resistant to chemical and biological corrosion, 9 they are not subject to erosion, their durability

exceeds that of plastics.

Insulation of flat roofin ISODACH MONO System

1 - Concrete slab 2 - Vapour insulation3 - ISOROOF-H4 - Waterproof/bitumen membrane

FLAT R

OO

F

Technical properties:

Šķietams blīvums PN-EN 1602 [kg/m3] [-] 140

Thickness [mm]

50 80 100Thermal resistance RD [m2K/W]

1,30 2,10 2,60

Declared thermal resistance RD for respective thicknesses of the product

Dimensions and packaging

Slabs dimensions No. of slabs in a package

Surface covered by package

Package volume

No. ofpackages

on a pallet

No. of slabs on a pallet

Surface covered by by slabs on a pallet

Mineral wool volume on a

palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3] [pcs] [pcs] [m2] [m3]

501000 600 6 3,60 0,180 16

57,60

2,88

2000 1200 24

801000 600 3 1,80 0,144 20

36,002000 1200 15

1001000 600 3 1,80 0,180 16

28,802000 1200 12

ISOROOF-H Mineral wool slabsFlat roofing - ISODACH MONO

ISOROOF-H MW-EN 13162-T3-DS(70,90)-CS(10)50-TR15-PL(5)500-WS-WL(P)-MU1

Declared properties of the product acc. to PN-EN13162+A1:2015-04

Test methodUnit of

measure-ment

Levels or tolerancesClasses of

levels codesValues

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2

Width (class of dimensional tolerance) [%] [-] ±1,5

Thickness (class of thickness tolerance)

<100 mmPN-EN 823

[mm/%]T3

- 3mm / + 10%

≥100 mm [%/mm] - 3% / + 10mm

Squareness Sb PN-EN 824 mm/m [-] ≤ 5

Flatness Smax PN-EN 825 mm [-] ≤ 6

Dimensional stability under specified temperature and relative humidity conditions

PN-EN 1604[%]

DS(70,90)± 1,0 (change of thickness,

length and width)[mm/m] ± 1 (change of flatness)

Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)50 ≥ 50

Tensile strength perpendicular to faces PN-EN 1607 [kPa] TR15 ≥ 15

Point load for 5 mm deformation PN-EN 12430 [N] PL(5)500 ≥ 500

Short-term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0

Long term water absorption by partial immersion PN-EN 12087 [kg/m2] WL(P) ≤ 3,0

Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,038

Reaction to fire PN-EN 13501-1 A to F Euroclass A1

Page 24: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

24

Catalog 2017

Thickness [mm]

50 80 100Thermal resistance RD [m2K/W]

1,28 2,05 2,56

Declared thermal resistance RD for respective thicknesses of the product

Product description:Slabs of mineral wool for thermal, acoustic and fire insulation of:

9 non-ventilated flat roofing in steel or concrete constructions in one-layer system ISODACH MONO,

9 floors under concrete, 9 as an acoustic insulation in acoustic screen.

Properties: 9 hard, 9 enhanced mechanical parameters, 9 easy in assembly and processing, 9 non-flammable, excellent protection against fire, 9 hydrophobized (do not absorb moisture), 9 produced from natural raw materials, 9 ensure proper heat comfort and allow walls to breathe, 9 resistant to chemical and biological corrosion, 9 they are not subject to erosion, their durability

exceeds that of plastics.

Technical properties:

Insulation of flat roof in ISODACH MONO System

1 - Concrete slab2 - Vapour insulation3 - ISOROOF4 - Waterproof/bitumen membrane

Apparent density PN-EN 1602 [kg/m3] [-] 150

ISOROOF Mineral wool slabsFlat roofing - ISODACH MONO

Dimensions and packagingSlabs dimensions

No. of slabs in a package

Surface covered by package

Package volume

No. ofpackages

on a pallet

No. of slabs on a pallet

Surface covered by by slabs on a

pallet

Mineral wool volume on a

palletThickness Length Width

[mm] [mm] [mm] [pcs] [m2] [m3] [pcs] [pcs] [m2] [m3]

501000 600 6 3,60 0,180 16

57,60

2,88

2000 1200 24

801000 600 3 1,80 0,144 20

36,002000 1200 15

1001000 600 3 1,80 0,180 16

28,802000 1200 12

On customer request there is a possibility of producing plates with other dimensions.

ISOROOF slabs have high values of thermal resistance RD, and thus they effectively contribute to energy saving.

ISOROOF

50÷99 mm 100÷150 mm

MW-EN 13162-T3-DS(70,90)-CS(10)50-TR15-PL(5)400-WS-WL(P)-MU1

MW-EN 13162-T3-DS(70,90)-CS(10)60-TR15-PL(5)400-WS-

WL(P)-MU1

Declared properties of the product acc. to PN-EN13162+A1:2015-04

Test methodUnit of

measure-ment

Levels or tolerances

Classes of levels codes

ValuesClasses of

levels codesValues

Length (class of dimensional tolerance)PN-EN 822

[%] [-] ± 2 [-] ± 2

Width (class of dimensional tolerance) [%] [-] ±1,5 [-] ±1,5

Thickness (class of thickness tolerance)

<100 mm

PN-EN 823[mm/%]

T3

- 3mm / + 10%

T3-

≥100 mm

[%/mm] -- 3% /

+ 10mm

Squareness Sb PN-EN 824 mm/m [-] ≤ 5 [-] ≤ 5

Flatness Smax PN-EN 825 mm [-] ≤ 6 [-] ≤ 6

Dimensional stability under specified temper-ature and relative humidity conditions

PN-EN 1604[%]

DS(70,90)

± 1,0 (change of thickness, length and

width) DS(70,90)

± 1,0 (change of thickness, length and

width)

[mm/m]± 1 (change of

flatness)± 1 (change of

flatness)

Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)50 ≥ 50 CS(10)60 ≥ 60

Tensile strength perpendicular to faces PN-EN 1607 [kPa] TR15 ≥15 TR15 ≥15

Point load for 5 mm deformation PN-EN 12430 [N] PL(5)400 ≥ 400 PL(5)400 ≥ 400

Short-term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0 WS ≤ 1,0

Long term water absorption by partial immersion

PN-EN 12086 [kg/m2] WL(P) ≤ 3,0 WL(P) ≤ 3,0

Water vapour diffusion resistance factor PN-EN 12087 [-] MU1 ≤ 1 MU1 ≤ 1

Thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,039 [-] ≤ 0,039

Reaction to fire PN-EN 13501-1 A to F Euroclass A1 Euroclass A1

FLA

T R

OO

F

Page 25: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

25

Catalog 2017

Product description:Used as thermal, acoustic and fire insulation of:

9 ventilated flat roofs, 9 cavity walls, 9 unused attic  on a concrete ceiling.

Properties: 9 high insulation properties, 9 high thermal comfort of insulated rooms, 9 prevents formation of thermal bridges, 9 non-flammable (they increase fire resistance class of the

building), 9 low diffusion resistance ensuring „free breathing”

of partitions, preventing their dampness, 9 produced from natural raw materials, 9 resistant to chemical and biological corrosion.

Insulation of attic1 - Construction of external wall2 - Vent3 - Roof covering4 - ISOLOOSE5 - Concrete slab

Technical properties:

ISOLOOSEMW-EN 14064-1-S1-WS-MU1

Declared properties of the productUnit of

measurementValues

Coverage and density [kg/m3] 60-70 Thermal conductivity λD [W/mK] ≤0,039 Susceptibility to loose material sedimentation % ≤1 Thermal resistance of fibres [°C] 750 Absorption at partial immersion [kg/m2] ≤1 Fire classification A1 non-flammable Hydrophobized do not absorb moisture

ISOLOOSE Granulated mineral woolFlat roofs

Packaging

Use:For 10 cm thick of insulation is required 6 kg/m2 of wool.

Unit of measurement Values

Bulk of 1 bag kg 10(±10%)Quantity of the bags per pallet pc 70

Bulk of pallet kg 700Quantity of pallets on a car pc 13

Weight of a full load kg 9100

1 3

2

4

5

VEN

TILATED

FLAT

RO

OF

Page 26: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

26

Catalog 2017

LABEL MARKING

PRODUCT NAME

PRODUCT CODE

DIMENSIONS

DECLARATION OF PERFORMANCE NO.

CE MARKING

DECLARED THERMAL CONDUCTIVITY

DECLAREDTHERMALRESISTANCE

PRODUCTION SHIFT

REACTION TO FIRE CLASS

25

ISOLIGHT d=50-200mmWM-EN13162-T4-DS(70,90)-CS(10)0,5-WS-WL(P)-MU1

Page 27: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

27

Catalog 2017

Informacje ogólne:• produkt należy rozpakowywać bezpośrednio

przed aplikacją by uniknąć nadmiernego kontaktu z towarem przy przenoszeniu

• należy utrzymywać obszary robocze w czystości• pozostałości, skrawki materiału należy umieszczać

w odpowiednich pojemnikach

General information:• remove packaging just before using product to

avoid the unnecessary contact with product while handling it

• keep working area clean and ventilated if possible • put any remains or pieces of material in suitable

containers

Allgemeininformationen:• Produkt soll vor der Verwendung direkt ausgepackt

werden, um unnötigen Kontakt mit der Ware bei Übertragung zu vermeiden

• Arbeitsbereichesollensaubergehaltenwerden• Überreste, Materialstückesollen in

entsprechendeBehältereingebrachtwerden

ISOROC Polska S.A.ul. Leśna 30, 13-100 Nidzicatel.: + 48 89 625 03 00, fax.: + 48 89 625 03 02e-mail: [email protected], www.isoroc.pl

Zalecane stosowanie odzieży ochronnej oraz używanie masek ochronnych w pomieszczeniach zamkniętych.It is recommended to wear protective clothing as well as masks and gloves in confined spaces.Man empfehle, Arbeitskleidung zu tragen sowie Schutzmasken in geschlossenen Räumen anzuhaben.

PL

EN

DE

INSTRUKCJA BEZPIECZNEGO UŻYTKOWANIA PRODUKTUSAFE USE INSTRUCTION SHEETINSTRUKTION FÜR SICHERE PRODUKTHANDHABUNG

PL

EN

DE

PL

EN

DE

Zalecane użycie okularów ochronnych

Safety glasses are recommended when working overhead

Schutzbrillezugebrauchen

PL

EN

DE

Zalecane opłukanie rąk zimną wodą przed ostatecznym myciem

Rinse hands in cold water before washing

Hände vor dem Endwaschen mit Kaltwasser abzuwaschen

PL

EN

DE

Max. 2,7 m

PL

EN

DE

PL

EN

DE

Zabrania się poruszania bezpośrednio po płytach pokładowych (ISOPANEL-D)

It is forbidden to walk on the underlayment panels (ISOPANEL-D)

Man verbiete, auf Unterlagsplatten (ISOPANEL-D) direkt zu treten.

Zaleca się stosowanie utwardzonych ścieżek komunikacyjnych, zabezpieczających przed bezpośrednim oddziaływaniem obciążeń skupionych na wełnę mineralną.It is recommended to use special communication paths which save mineral wool from the direct influence of concentrated loads.Man empfehle, befestigte Kommunikationswege anzuwenden, die vor der direkten Auswirkung von Punktlast auf die Mineralwolle schützen würden

Przechowywać w oryginalnym opakowaniu aż do momentu aplikacji, w sposób zabezpieczający przed wilgocią i opadami atmosferycznymiStore pallets in original packaging to protect the product from humidity and precipitation until the application momentProdukt soll in der Originalverpackung bis zur Verwendung aufbewahrt werden, abgesichert vor Feuchte und Niederschlägen.

PL

EN

DE

PL

EN

DE

Maksymalna wysokość składowania do 2,7 m

The maximum storage height up to 2.7 m

Maximale Legerungshöhe bis zu 2,7 m

26

Page 28: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

28

Catalog 2017

Notebook

Page 29: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

29

Catalog 2017

Notebook

Page 30: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

30

Catalog 2017

Notebook

Page 31: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

31

Catalog 2017

Notebook

Page 32: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

32

Catalog 2017

Notebook

Page 33: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

33

Catalog 2017

Notebook

Page 34: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

34

Catalog 2017

General Terms of deliveryGENERAL TERMS OF DELIVERYIsoroc Polska S.A. Nidzica-based (hereinafter: “ISOROC”) sells its products to trading partners basing on the purchase order placed by the customer, and confirmed by ISOROC pursuant to the rules mentioned in the following document. Conclusion of a contact requires the written form of an order placed by the customer, as well as the written declaration of acceptance of the “General terms of delivery,” and the written acceptance of a purchase order by ISOROC. The customer is notified of the “General terms of delivery” with an attachment to the part-nership agreement, or at the latest with placing the order. The general terms of delivery can also be found on the official website www.isoroc.pl and in the product catalogue. If a customer remains in a regular economic relation with ISOROC, accepting the conditions once, will be binding for all further orders, until the conditions are modified. If the customer hasn’t made a statement about accepting the General terms of delivery, ISOROC may withhold order implementation until receiving the written statement , or until agreeing on different conditions of delivery. After setting a suitable date for accept-ance, or agreeing on different terms of delivery, ISOROC may retract from realizing the order. The ISOROC’s product catalogue is edited in a written form, as well as on the website www.isoroc.pl ISOROC may produce non-standard goods (not mentioned in the product catalogue). Placing an order for non-standard goods requires individual agreement with ISOROC each time goods are ordered, nevertheless ISOROC reserves the right to decline realizing the non-standard order. The orders must be in a written form and comprise the following information:

a) Selection, dimensions of ordered goods,b) Quantity c) Priced) Delivery date and delivery schedule e) Means of payment f) Destination g) Unloading manner (top / side ) h) Name and address of the customer i) Name, surname, and telephone number of the person who placed the orderj) Name, surname, and telephone number of the person who is entitled to accept the goods.

An exemplary order form is on website www.isoroc.plAn order for long-term deliveries should include a schedule of the planned deliveries.The ISOROC’s Customer Service Department is at customer’s disposal Monday to Friday, be-tween 7 a.m. and 3.30 p.m. Orders may be placed round the clock by fax: +48896250319 or by e-mails: a) Orders within the Polish territory: [email protected] ; [email protected];b) Foreign orders: [email protected] ; [email protected] .The Customer Service Department confirms the receipt of an order within 2 working days and informs the customer about the estimated delivery date which depends on the prod-uct’s availability. If the delivery of the ordered product is not possible as previously indicated by the Custom-er Service Department, ISOROC will immediately confirm the next closest date of order’s realization. Unless the customer objects within one working day, the new delivery date is binding. Isoroc Polska S.A. will not be liable for order mistakes.Date of order acceptance shall be the date of sending confirmation of order acceptance. Order placed without delivery schedule is valid for 30 days. Upon lack of the order fulfillment it is automatically cancelled. ISOROC shall not be held liable for order mistakes. ISOROC reserves the right to charge the customer with the production and transportation costs due to the mistake.Any modifications of the orders, their amendments and cancellations shall be made in writ-ing. In case of standard products – changes shall be made not later than 2 working days before the delivery date. Changes will not be taken into account, if the goods have already been sent out. In case of non-standard products – changes shall be made not later than 2 working days before the assortment production. Changes shall not be taken into account, if

§1

§2

§3

§4

§5

§6

§7

§8§9

§10

§11

§12 §13§14

§15

§16

the goods have already been sent out. In case of non-standard products – changes shall be made not later than 2 working days before the assortment production. Changes shall not be taken into account, if the goods have already been produced. Introducing changes to the order may delay the previously quoted date of delivery.ISOROC reserves the right to suspend accepting further purchase orders and realizing the already accepted ones if the customer is in arrears, of is customer’s trade credit has been exceeded.ISOROC reserves the right to change the confirmed orders and estimated dates of delivery as a result of force majeure. “Force majeure” means any situation that could not have been fore-seen, inter alia: natural catastrophes: earthquakes, hurricanes, floods, fire; general strike, roadblock, blockage of any other commonly used places of entry /exit, epidemic, as well as breakdowns, lack of water, energy and resources deliveries that preclude ISOROC from working for a period longer than 3 working days. In case ISOROC, due to the force majeure, cannot realize the confirmed order, customer will be immediately informed of the situation, and estimated date of delivery. ISOROC reserves the right to retract from realizing the order without being held responsible or bearing costs for unrealized orders. If the estimated date of delivery is 72 hours longer than the originally agreed one, the customer is entitled to resign from the ordered goods being delivered without bearing any additional costs.

DELIVERING ORDERED GOODS ISOROC delivers goods to an appointed place within Polish territory at its own expense, with-out bearing the costs of unloading and possible demurrage at the unloading place. The customer may collect the ordered goods form the ISOROC’s warehouse using their own means of transport, after having pre-concerted it with ISOROC. However: - ISOROC shall not be held liable for any damages caused during the transport, - ISOROC shall not be held liable for goods damaged due to inadequate means of transport,- Vehicle provided by the customer should guarantee loading the whole order,- Person collecting the goods must have an authorization issued by the customer,- Person collecting the goods must sign the goods dispatch note, providing the precise time and date of the collection..Truck unloading time should not exceed 2 hours.The railway deliveries are possible after prior notification about this fact to ISOROC, costs evaluation and acceptance by the customer.Minimum quantity of delivery is specified on the basis of individual arrangement between ISOROC and the customer, and depends on the possibility to organize joint deliv-eries to several unloading places. In such a case, the price of the product may be higher than the standard one, due to higher transport costs.ISOROC has the right to charge the customer with transport cost, if wrong delivery address was provided in the order form, which resulted in necessity to transport the goods to another location, or if the ordered goods were not collected from the delivery place at the appointed time.One order is for one unloading place. Delivery of a full truck of goods may be unloaded in more than one place, at additional transport and unloading charge.Deliveries to a place specified in the order shall be realized only if there is a physical possibil-ity of getting to the unloading place. However, driver may refuse to deliver the goods in case there is a possibility of damaging the goods, or a vehicle. If there’s no possibility of unloading the goods at the specified delivery place, the goods may be transported to another place appointed by the customer, at additional charge.In case the customer resigns from the order, or do not collect it from ISOROC’s warehouse within 60 days from placing the order, ISOROC is entitled to charge the customer with costs of production, transporting, and storing the goods for 60 days.In case of deliveries based on prepayment – the delivery date should be calculated from the date of crediting money to ISOROC Polska’s bank account.The delivery is considered completed once the goods are unloaded at the agreed unloading point and the consignment note is handed over to a person who placed the order, or a person authorized by the customer. In case the goods are picked up from the ISOROC’s warehouse, the delivery is considered executed once the goods are loaded on the provided vehicle.

§17

§18

§1

§2

§3 §4

§5

§6

§7

§8

§9

§10

§11

Page 35: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

35

Catalog 2017

Person accepting ordered goods on behalf of the customer must have an authorization is-sued by the customer. The customer, or the person authorized by him to goods receipt, is obliged to sign the goods dispatch note and to acknowledge the conformity of the delivery with the consignment note. ISOROC shall not bear costs for any damages to the goods during unloading.The invoice for the receipt of product is sent by post, or in case of a consent for receiving electronic invoices – by e-mail, the next working day after delivered shipment, or collection from the ISOROC’s warehouse.

COMPLAINTSISOROC declares that all products admitted to trading marked with CE sign, are manufac-tured in compliance with effective standards. Products admitted to trading have necessary documents which permit them to be sold accordingly to the application advised by the man-ufactures. Products have Certificate of Constancy of Performance common to them all, and Declaration of Performance for each product.Documents which allow products of ISOROC to be used in construction may be found on the ISOROC website: www.isoroc.pl. Documents are not handed to the customer with ordered goods.All complaints are handled in accordance with effective law within the Polish territory.The complaint must be filed specifically by (or via ) direct Customer (buyer).The complaint must be submitted in writing within the below mentioned time limit. The complaint must comprise: Customer’s name, surname, telephone number of the person fil-ing the complaint, the goods dispatch note number or the invoice number, detailed descrip-tion and quantity of the product (an exemplary complaint form is available online: www.isoroc.pl in downloads /commercial documents folder.The customer shall receive response to reported complaint within 14 day (21 days in case of export deliveries) from the date of receiving the complaint. ISOROC will make every effort to deal with the complaint as quickly as possible. In case the complaint is filed against the above mentioned conditions - points 4 and 5, ISOROC will notify the customer about the necessity to fill in the form within 3 days from receiving the notification. Unless the form is filled in properly, the complaint won’t be accepted. The period for settling the complaint is measured from the day the customer completes the complaint form.In cases when complaint settlement requires additional procedures to be put in place which may prolong its processing time, or in case of any other circumstances potentially prolong-ing the settlement – the customer shall receive a notification within 14 days from the date of complaint being reported, together with the estimated time of it handling.

Wrong delivery complaints Complaints due to the wrong delivery comprise quantity complaints, complaints of the damaged products, discrepancy between the order and received goods, state of the packag-ing, and the delivery term. The customer is obliged to confirm the delivery and check its condition immediately after receiving the goods. Any damages, shortages or delays to the delivery must be noted on each copy of the goods dispatch note, and the consignment note.Any reservations about the delivered goods must be officially confirmed by the signatures of the person responsible for the goods receipt and the driver/ carrier/ railway employee.Complaints due to the incorrect delivery should be placed immediately, i.e. at the latest the next working day after unloading.- ISOROC shall not be held liable for any damages caused during unloading, and faulty stocking of goods (i.e. not in compliance with the safe use instruction sheet placed on every pallet) and other circumstances for which the customer is responsible. ISOROC shall not be liable for any damages due to transport or quantity discrepancies in case when customer arranges the transport of goods on his own from ISOROC’s warehouse .In case when the complaint is filed contrary to the conditions or dates mentioned in this document, the delivery shall be assumed successful and the complaint will be rejected. Quality Complaints

§12

§13

§1

§2

§3§4§5

§6

§7

§1

§2

§3

§4

§5

QUALITY COMPLAINTS Quality complaints concern any doubts over technical parameters of delivered goods.The customer is obliged to secure faulty goods together with purchase documents and to store it in a manner preventing from any damages until the ISOROC’s representative comes to evaluate the product.Complaints must be filed in writing by the Customer who bought the goods from ISOROC.In case of complaints filed by the contractor, the complaint must be filed directly at the company which had supplied him with the ISOROC’s products, and this company must im-mediately hand the complaint over to ISOROC by fax or e-mail. The original of the complaint may be sent later by post, and the date of its receipt shall not be considered in the course of complaint handling.Immediately upon the receipt of the complaint by ISOROC, but the next working day at the latest, it shall be handed over to the respective technical advisor and the appropriate re-gional sale manager who will contact the customer in order to arrange a meeting leading to assessment of the claimed product.During the arranged meeting ISOROC’s representative together with customer will prepare a protocol note which should consider visual assessment of the claimed product, manner of its storage, warehousing, and transport adequacy , or possibly the correctness of its assembly and usage. If the ISOROC’s representative considers it applicable – he may take a sample of a claimed product from applied or non-applied products in order to pass it for laboratory tests.In case when a collective assessment of the claimed product is required, technical advisor will inform customer (by phone, mail or fax) of the planned visit of the c o m p l a i n t commission on the spot. The complaint commission is authorized to expose a chosen part of the applied product to take representative samples for independent laboratory examina-tion. Samples should be marked and stamped with company’s seal by both sides. The result of the examination shall be binding for both sides.If the purchased product raises doubts about its quality, and yet is applied, ISOROC is not liable for any resultant flaws or costs.Quality complaints should be filed at ISOROC immediately, but not later than in 3 days from noticing the defect, and not later than in 3 months from the date of receipt / pickup of goods.In case of latent defects, the quality complaints should be filed immediately after finding the default, but not later than in 7 days from finding it.If the complaint is filed contrary to the conditions or time limit indicated in the document, the goods shall be considered accepted without reservations, and the complaint shall be rejected.ISOROC shall not be liable for the mistakes of the customer, or any third party, i n c l u d i n g losses due to inadequate product application, and project / executive mistakes, as well as force majeure.

Final Provisions The General Terms of Delivery are an integral part of all concluded contracts.The General Terms of Delivery may be modified. In case any changes are introduced, the customer shall be informed of them in writing.The general Terms of Delivery shall be valid from 01.06.2014 and replace the former General Terms of Delivery and Realization of DeliveriesAny potential dispute which may directly or indirectly result from the contractual relation-ship based on the above mentioned terms, shall be settled in compliance with Polish law, whereas the competent court shall be in accordance with ISOROC’s actual headquarters.

§1§2

§3§4

§5

§6

§7

§8

§9

§10

§11

§12

§13

§1§2

§3

§4

Page 36: PRODUCT CATALOG - ISOROC · PRODUCT CATALOG 2017 ... external façades with panel façades insulated by light-dry method with cladding made of stone, glass ... Slabs of mineral wool

36

Catalog 2017

CUSTOMER SERVICE DEPARTMENT MARKETING

EXPORT AND OEM SALES DIRECTOR TECHNICAL ADVISOR

Małgorzata SobotkaManager of Sales Service DepartmentPhone: +48 89 625 03 08Fax: +48 89 625 03 02Mobile: +48 798 840 533E-mail: [email protected]

Tomasz ParysPhone: +48 89 625 03 13Fax: +48 89 625 03 19 Mobile: +48 504 220 177E-mail: [email protected]

Wioletta Korowaj Phone: +48 89 625 03 45 Fax: +48 89 625 03 02 Mobile: +48 516 059 835 E-mail: [email protected]

Marta PareckaCustomer Service ManagerPhone: +48 89 625 03 46 Fax: +48 89 625 03 19 Mobile: +48 515 278 369 E-mail: [email protected]

Kornelia KochanowskaExport SpecialistPhone:  +48 89 625 03 11 Fax: +48 89 625 03 19 Mobile: +48 517 589 763E-mail: [email protected]

Leśna 30 Street, 13-100 NidzicaPhone: +48 89 625 03 00Phone: +48 89 625 03 46Fax: +48 89 625 03 19E-mail: [email protected]

Isoroc Polska S.A.

Area Sales Managers

Other Countries

1

2

3

4

12

3

4

Erika KertészMobile: +36 309 048 111 E-mail: [email protected]

Paweł JasińskiMobile: +48 517 589 954E-mail: [email protected]

Western RegionE-mail: [email protected]

Tomasz ParysExport and OEM Sales Director

NIDZICA