Powder Transfer Diaphragm Pumps · 2018. 4. 7. · Talc Toners And many more... The performance...

2
www.yamadacorp.co.jp/global Powder Transfer Diaphragm Pumps The Yamada Powder Transfer Pumps were specifically designed to move bulk solids more effectively throughout your process. They are a cost effective replacement for Augers and Conveyors and eliminate unsafe and labor intensive means of moving bulk powders. These heavy duty pumps consistently transfer fine-grained (100μm or finer), low bulk density (5 to 10 lbs. / cubit foot or 0.07 to 0.16kg/litter), dry powders in a dust-free operation. Yamada offers a base unit specifically for light powders, which include the following standard features. Conveying distance depends upon the micron size and the bulk density of the powder. For example fumed silica can be conveyed 150 feet(4.5M) while flour a maximum of 40 feet(12M). Refer to the Yamada “Pumpable Powders” data sheet for specific materials. Powder must be 150 mesh(106 micron)or smaller size particle / powder and dry. The Pump will not pump crystals or flakes and the bulk density should be less than 50lbs/cubic feet, The higher the bulk density, the shorter the conveying distance and the lower the flow rate. The Pump can be located a maximum of 15feet(4.5M) above powder source. PTFE check balls are recommend for sticky powders. - Apparent specific gravity is 0.5 or less - Repose angle is 30 degree or less - Powder must be completely dry - Powder must have large fluidity Yamada recommends regulating compressed air to 70PSI(0.5MPa) M a x i m u m . Yamada recommends aeration / fluidization of the powder a minimum of 10 to 15 seconds prior to starting the pump- premature diaphragm, center shaft, and center disk failure can be avoided. Applications Activated Carbon Acrylic Resins Aluminum Oxide Bentonite Carbon Black Cereal Flours Clay Powder Diatomaceous Earth Expanded Mica Fire - extinguishing Powder Fumed Silica Ground Limestone Kaolin Micro Dolomite Filter Dust Pearlite Pesticides Pharmaceuticals Pigments Powder Coatings Powdered Plastics Powdered Rock Quartz Powder Salicylic Acid Silicones Starch Talc Toners And many more... The performance data for powder transfer is highly dependent upon the material being pumped and the application. A trial of the pump in the actual use environment is recommended to verify the actual performance capabilities for any given material. REMARK Condition of powder

Transcript of Powder Transfer Diaphragm Pumps · 2018. 4. 7. · Talc Toners And many more... The performance...

Page 1: Powder Transfer Diaphragm Pumps · 2018. 4. 7. · Talc Toners And many more... The performance data for powder transfer is highly dependent upon the material being pumped and the

www.yamadacorp.co.jp/global

Powder Transfer Diaphragm PumpsThe Yamada Powder Transfer Pumps were speci�cally designed to move bulk solids more e�ectively throughout your process.They are a cost e�ective replacement for Augers and Conveyors and eliminate unsafe and labor intensive means of moving bulk powders.These heavy duty pumps consistently transfer�ne-grained (100μm or �ner), low bulk density(5 to 10 lbs. / cubit foot or 0.07 to 0.16kg/litter),dry powders in a dust-free operation.Yamada o�ers a base unit speci�cally for lightpowders, which include the followingstandard features.

● Conveying distance depends upon the micron size and the bulk density of the powder. For example fumed silica can be conveyed 150 feet(4.5M) while �our a maximum of 40 feet(12M). Refer to the Yamada “Pumpable Powders” data sheet for speci�c materials.● Powder must be 150 mesh(106 micron)or smaller size particle / powder and dry. The Pump will not pump crystals or �akes and the bulk density should be less than 50lbs/cubic feet, The higher the bulk density, the shorter the conveying distance and the lower the �ow rate.● The Pump can be located a maximum of 15feet(4.5M) above powder source.

● PTFE check balls are recommend for sticky powders.

- Apparent speci�c gravity is 0.5 or less

- Repose angle is 30 degree or less

- Powder must be completely dry

- Powder must have large �uidity

● Yamada recommends regulating compressed air to 70PSI(0.5MPa) M a x i m u m .

● Yamada recommends aeration / �uidization of the powder a minimum of 10 to 15 seconds prior to starting the pump- premature diaphragm, center shaft, and center disk failure can be avoided.

Applications

Activated Carbon Acrylic Resins

Aluminum Oxide Bentonite

Carbon Black Cereal Flours Clay Powder

Diatomaceous Earth Expanded Mica

Fire - extinguishing Powder

Fumed Silica Ground Limestone

Kaolin Micro Dolomite Filter

Dust Pearlite

Pesticides Pharmaceuticals

Pigments Powder Coatings

Powdered Plastics Powdered Rock Quartz Powder

Salicylic Acid Silicones Starch

Talc Toners

And many more...

The performance data for powder transfer is highly dependent upon the material being pumped and the application. A trial of the pumpin the actual use environment is recommended to verify the actual performance capabilities forany given material.

REMARKCondition of powder

Page 2: Powder Transfer Diaphragm Pumps · 2018. 4. 7. · Talc Toners And many more... The performance data for powder transfer is highly dependent upon the material being pumped and the

Powder Transfer Diaphragm Pumps

International DepartmentNo.1-3, 1-Chome, Minami-Magome, Ohta-ku,Tokyo 143-8504, Japan

Phone +81-(0)3-3777-0241 Fax +81-(0)3-3777-0584

E-mail: [email protected]: www.yamadacorp.co.jp/global

Your Local Distributor:

Form no.:910-501E Revised: Mar.2015

Model BAC1”(25A)

BANNDP-25

Rc1

Rc3/8Rc3/4

ADC12

CR

SMS1025 SUS316SUS316

Approx 200kg/h1600L/min(ANR)3mm or smaller

97dB13kg 20kg

CRNBR NBR

ADC12

SCS14

BSC BSN BAC1-1/2”(25A)BANNDP-40

JIS 10K40A

Rc1/2Rc3/4

ADC12,AC4C-T6

CR

SUS316A5056

Approx 500kg/h4000L/min(ANR)7mm or smaller

95dB29kg 40kg

CRNBR NBR

CR CRNBR NBR

ADC12

SCS14

BSC BSN BAC2”(50A)

BANNDP-50

JIS 10K50A

Rc3/4Rc1

ADC12,AC4C-T6

CR

SUS316A50560.2-0.7 MPa

0.7 MPa

0.7 MPa

Approx 1000kg/h6000L/min(ANR)10mm or smaller

94dB37kg 60kg

CRNBR NBR

CR CRNBR NBR

ADC12

SCS14

BSC BAC3”(50A)

BANNDP-80

JIS 10K80A

Rc3/4Rc1

ADC12,AC4C-T6

CR

SUS316A5056

Approx 1000kg/h6000L/min(ANR)10mm or smaller

92dB65kg 102kg

CRNBR

CR CRNBR

NBR

NBR

ADC12

SCS14

BSCBSN BSN

Connection to liquid

Air connection

Material

Air supply pressure rangeMax discharge pressureMax discharge volumeMax air consumptionMax slurry diamaeterAmbient temp rangeNoise levelWeight

Inlet

InletOutlet

Outlet

Wetted body

Non wetted body

Diaphragm, Ball

Ball seatCenter disk

Nominal port size

NDP-25 NDP-40

NDP-50 NDP-80

642712

403

200250

96

108

(142)

108

(305)(147)

(570)266

4-Ø10

294

Rc 4/3

Rc 2/1

EXHAUST

JIS 10K 40ADN 40 PN 10

LIQUID INLETEQUIVALENT TO

LIQUID OUTLET

JIS 10K 40ADN 40 PN 10EQUIVALENT TO

AIR INLET

288

355

704782

433

250300

106

116

116168

6304-Ø10

324

DIN 50 PN 10ANSI 150 2″

JIS 10K 50A

EQUIVALENT TOOUTLET

AIR INLET

JIS 10K 50A DIN 50 PN 10 ANSI 150 2″EQUIVALENT TOINLET

EXHAUSTRc1

43/Rc

4-Ø10(704)

364

416

128

1001

906

300350

137

433

137(168) 363

DIN 80 PN 10 ANSI 150 3″ JIS 10K 80A

INLETEQUIVALENT TO

EXHAUSTRc1

AIR INLET

DIN 80 PN 10ANSI 150 3″JIS 10K 80A

OUTLETEQUIVALENT TO

43/Rc

Speci�cations

Dimensions

/3Rc 4

Rc /3 8

(252)

49343 382

(395)(143)

196

30

210170

186

30

(414)

287222

129

137

89279

4-Ø9EXHAUST

Rc1

LIQUID INLETRc1

LIQUID OUTLET

AIR INLET