Performance of the LHCb calorimeters during the period 2010-2012

36
Performance of the LHCb calorimeters during the period 2010-2012 Xavier Vilasís-Cardona 20131125 V CPAN Days - Xvc 1

description

Performance of the LHCb calorimeters during the period 2010-2012. Xavier Vilasís -Cardona. LHCb Calorimeters. RICH 1 & 2 PID: K vs. π. Preshower (PS)/ Scintillator Pad Detector (SPD) Electromagnetic Calorimeter (ECAL) Hadronic Calorimeter (HCAL). 10-250 mrad. 10-300 mrad. MAGNET. - PowerPoint PPT Presentation

Transcript of Performance of the LHCb calorimeters during the period 2010-2012

Page 1: Performance of  the  LHCb calorimeters during the period 2010-2012

1

Performance of the LHCb calorimeters

during the period 2010-2012

Xavier Vilasís-Cardona

20131125 V CPAN Days - Xvc

Page 2: Performance of  the  LHCb calorimeters during the period 2010-2012

2

Y~7mX~8.5m

Z~2.7m

HC

AL

ECA

L

PS/SPD

LHCb Calorimeters

20131125 V CPAN Days - Xvc

10-250 mrad

10-300 mrad

VELOVertexing

MAGNET

Calorimeters

PID: e,, 0

Muon Stations

RICH 1 & 2PID: K vs.

π

Trackers TT+IT+OTMomentum resolution

• Preshower (PS)/Scintillator Pad Detector (SPD)

• Electromagnetic Calorimeter (ECAL)• Hadronic Calorimeter (HCAL)

Page 3: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 3

Purpose of LHCb calorimeters• Preshower (PS) and Scintillator Pad Detector (SPD):

• PID for L0 electron and photon trigger• electron, photon/pion separation by PS• photon/MIP separation by SPD• charged multiplicity veto by SPD

• Electromagnetic Calorimeter (ECAL):• Et of electrons, photons and π0 for L0 trigger (e.g. B → J/Ψ Ks,

B → K*γ)• reconstruction of π0 and prompt γ offline• particle ID

• Hadron Calorimeter (HCAL):• Et of hadrons for L0 trigger (e.g. B → π π , B → DsK)• particle ID

20131125

Page 4: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 4

PS and SPD

• Scintillator blocs with coiled WLS fiber• Geometry projective with ECAL: 3 zones• MAPMT Hamamatsu 5900 M64• 6000+6000 Cells

20131125

Side view of upper part

Inner + Middle + Outer Modules

e-

SPD Pb PS ECAL

JINST 3 S08005 (2008)

Page 5: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 5

ECAL• Shashlik• PMT readout Hamamatsu R7899-20• Energy resolution σ(E)/E = 0.085 ± 0.01/ E 0.008 0.003 x/E⊕ ⊕ ∗• 6000 cells

20131125

3312 shashlik modules with 25 X0 PbInne

r Module 9 cells: 4x4 mm2

Middle Module 4 cells: 6x6 mm2

OuterModule 1 cell: 12x12 mm2

Sc:Pb = 4:2 mm25 X0

12x12 mm2

Chariot

Electronicplatform

modules

Beam plugJINST 3 S08005 (2008)

Page 6: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 6

HCAL• Tile structure• PMT readout Hamamatsu R7899-20• Energy resolution√σ(E)/E = (0.69 ± 0.05)/ E (0.09 ± 0.02) ⊕• 1500 Cells (inner-outer)

20131125

particles

PMT

scintillators

WLSfiberslight-guide

Electronicsplatform

Chariot

modules

Beam plug

Weight : ~9.5 ton

JINST 3 S08005 (2008)

Page 7: Performance of  the  LHCb calorimeters during the period 2010-2012

Front End Electronics

20131125 V CPAN Days - Xvc 7

Page 8: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 8

Installation and Commissioning• Installation from 2004-2008• Commissioning 2005-2009• First cosmic seen January 2008• Commissioning using built in

monitoring tools, cosmics and splash events.

20131125

OT

Calo Muon

Page 9: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 9

Calibration and Monitoring

• Calibration strategies– PS / SPD

• Fit the MIP signal and look for efficiencies– ECAL

• Initial adjustment • Energy Flow• Fit Pi0 mass• E/p for electrons

–HCAL• Built in 137Cs source

• Detectors include built in LED system for monitoring detector stability

20131125

Page 10: Performance of  the  LHCb calorimeters during the period 2010-2012

LED monitoring system of XCAL

20131125 V CPAN Days - Xvc 10

LEDLEDLEDLEDLEDLEDLED

Driver

Splitter

PIN diod

eADC

LEDLEDLEDLEDLEDPMT…

• Control of time and temperature stability• Small pulse duration and dispersion of amplitude • Adjustable pulse rate and amount of light• Emulate e/m particles in full “physics” region • Gain control to better than 1% accuracy• Control only electronics chain supply LED light directly to the

PMT• Use empty bunches for running monitoring system

ECAL 512 LED drivers &

LEDs & splitters & fiber-bundles

64 PIN-diodesLED pulse50 GeV e-

Page 11: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 11

PS-SPD

20131125

• Tracks pointing to given PS/SPD cell are extrapolated• PS: MIP signal is fitted and fixed to a given number

of ADC counts• SPD: signal is checked for existing tracks

SPD Efficiencies (2011)PS MIP EnergyDistributionApril 2011

Page 12: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 12

ECAL – Initial calibration + Energy Flow

• Initial Calibration (relative width of π0 peak, 10%)

• Energy Flow– Equalize the energy flow over 3x3 cell blocks

20131125

10% miscalibration

Page 13: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 13

ECAL – Fine Calibration

• Currently absolute calibration based on the ‘Mass distribution fit’ method

(O.Igonkina et al. HERA-B 00-103)• Fit π0 mass from 2 photon signals in ECAL• Iterative procedure

– Select photons (3x3 clusters) and fix seed (central) cell.– For each cell– Compute di-photon invariant mass– Fit π0 mass distribution– Correct calibration of seed cells– Restart until stable

20131125

Page 14: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 14

π0 mass

20131125

Mass distribution fit algorithm 2011 data (june)

Initial calibration value

Final calibration value About 6% error

Page 15: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 15

E/p• Another method to monitor or correct the ECAL cell calibration is

through electron E/p• Electrons are identified by estimation of the momentum of the

extrapolated of tracks and energy of the matching clusters.• Used to monitor ageing.

20131125

E/p for electrons in ECALE/p for hadrons in ECAL2011 data

Page 16: Performance of  the  LHCb calorimeters during the period 2010-2012

Ageing on ECAL– 0 mass variation as a function of time (luminosity) observed:

V CPAN Days - Xvc20131125

– Optical fibres of ECAL LED monitoring system are also affected– The effect is cured by calibrating ECAL:

• Apply fine calibration of each ECAL cell using 0 and adjusting its mass on a short period of data taking

• On top of fine-calibrated data trending coefficients are applied:– 0 statistic not high enough to follow closely the changes– Make use of photon conversion and look at E/p

Page 17: Performance of  the  LHCb calorimeters during the period 2010-2012

17

HCAL Calibration• HCAL absolute Calibration

– Based on 137Cs source scans performed during technical stops

– LEDs used to monitor.

V CPAN Days - Xvc20131125

Page 18: Performance of  the  LHCb calorimeters during the period 2010-2012

The “PMT sensitivity variation” is the PMT gain variation reduced to the initial (March 2011) HV, calculated from the calibration coefficients.

Ageing on HCAL (both on detector and PMT)

V CPAN Days - Xvc 18

Can be corrected byModifying PMT gain

(HV)Calibration

Cs source runs + LED Scintillator rows in the tile get affected depending on their depth

20131125

PMT gainLoss expectedWith cumulated charge

Page 19: Performance of  the  LHCb calorimeters during the period 2010-2012

Photon Reconstruction

• Clusters : 3x3 cells– Barycenter, – Energy – Spread

• Match fitted tracks to discard charged particles

• Mass resolution :

20131125 V CPAN Days - Xvc

Page 20: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 20

π0 reconstruction

20131125

• Neutral π0 – Low energy : resolved pair of γ – mass resolution : 8 MeV/c2

– High energy : overlapped γ clusters – iterative algorithm to separate in two subclusters – mass resolution : 20 MeV/c2

Page 21: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 21

Photon identification and merged π0

• Photon Hypothesis uses– PS energy ,Ratio of energy, Χ2

2D • Separating merged π0 from γ

– Uses cluster shape– MLP– Trained on simulation– Checked on data B and D decays

20131125

pT>500MeV/c

pT>200MeV/c

Page 22: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 22

Converted Photon Reconstruction

• Converted photons produce a pair (ee) • Correct for e bremsstrahlung

– Bremsstrahlung candidate : neutral energy deposition with Χ2 < 300 from a charged track.

20131125

DataMC

Page 23: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 23

Electron Identification

• Build reference histograms – use converted γ reconstructed from events triggered

by muon detector – Hadron background made of π and K from D0

decays– Use 340 pb-1 from 2011 data

• Histograms built for PS, ECAL and HCAL• Identification is based on E/p refined using

X22D and also EPS and EHCAL

20131125

EPS

E/p

EHCAL Χ22D

Page 24: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 24

Combined Performance of electron identification

20131125

Electron Efficiency

MisId rate

p

eh

Tag and probe method using e from

Probe e efficiency

Page 25: Performance of  the  LHCb calorimeters during the period 2010-2012

2525

LHCb Upgrade Architecture

24th April 2013 CHEF 2013

Ken Wyllie, CERN 25

HLT

Current

HLT++Upgrade

1MHzeventrate

40MHzeventrate

Readout Supervisor

L0 Hardware

Trigger

Readout Supervisor

Low-Level Trigger

50 Tb/s

Low-Level Trigger

1 to 40 MHz

LOW Level Trigger decision

from Front-End to Back-End

20130521 Xvc - ISCAS 2013

Page 26: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 26

Upgrade

• New features• PS and SPD shall be eliminated (they mainly

contribute to L0 trigger)• DAQ @ 40MHz

– Change in the readout electronics• Lower PMT gain

– Higher luminosity– Ageing

• New electronics under development• TDR under review

20131125

Page 27: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 27

Conclusions

• LHCb calorimeters fully functional• Ageing observed

– Frequent calibrations• Precise Physics Results• Upgrade

– Leave ECAL-HCAL– Software trigger– New DAQ electronics

20131125

Page 28: Performance of  the  LHCb calorimeters during the period 2010-2012

28

Performance of the LHCb calorimeters

during the period 2010-2012

Xavier Vilasís-Cardona

20131125 V CPAN Days - Xvc

Page 29: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 29

BACKUP

20131125

Page 30: Performance of  the  LHCb calorimeters during the period 2010-2012

Time Alignment

30

• DAQ feature: Time Alignment Events• Equalise an a-priori delay from theoretical values• Adjust BXID so that an event is mainly seen on Current• Adjust integration time t0

– Select the pair of BX with maximum signal• Prev1/Current vs. Current/Next1

– Compute the asymetry R• All XCAL channels adjust within 1ns

Nevt

iij

Nevt

iij

Nevt

iij

Nevt

iij

NextECurrentE

NextECurrentERj

)()(

)()(

tT0 Next1Prev1

25 ns

δTsamplingδTsamplingδTsampling

20131125 V CPAN Days - Xvc

Page 31: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 31

First π0 fit – Nov 2009• Initial calibration was performed by setting a uniform

ADC count value per transverse energy unit.• This calibration allowed to fit the π0 peak in

NOV2009

20131125

M=133 ± 3 MeV/c2, with σ = 11 ± 4

Page 32: Performance of  the  LHCb calorimeters during the period 2010-2012

20131125 V CPAN Days - Xvc 32

B production in LHCb b and b quarks are produced in pairs bb production is correlated and sharply peaked forward-backward LHCb single-arm forward spectrometer : θ~15-300 mrad (rapidity range: 4.9>η>1.9) Cross section of bb production in LHCb acceptance: σbb ~ 230 µb LHCb limits luminosity to few 1032cm-2s-1 instead of 1034cm-2s-1

by not focusing the beam as much as ATLAS and CMS Maximizes probability of a single interaction per crossing Design luminosity from start-up of LHC ~ 1012 bb pairs produced/year in LHCb acceptance

pp interactions/crossing

LHC

b

n=0

n=1

ATLA

S/C

MS

boostb

b

Page 33: Performance of  the  LHCb calorimeters during the period 2010-2012

LED monitoring system of HCAL

20131125 V CPAN Days - Xvc 33

blue LEDs (WU-14-750BC) two independent LEDs per

module adjustable LED pulse amplitude monitoring PIN photodiode at

each LED in order to account for LED instability

light distribution with clear fibers of same length

timing of the LED flashing pulse adjustable with 1 ns step

0.2%

Monitoring of LED with PIN diode

Page 34: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc

Radiative decays bq

• Radiative b(d, s), one-loop penguin transition, sensitive to NP.

• Theoretically clean FCNC transition & experimentally accessible. • Many observables: branching fractions (BR), CP asymmetries

(ACP), isospin asymmetry, helicity structure of the photon.

34

NP may introduce sizeable effects on the dynamics of the transitions, through contributions of new particles inside the loops

20131125

Page 35: Performance of  the  LHCb calorimeters during the period 2010-2012

V CPAN Days - Xvc 35

Time Alignment results-ECAL

• All XCAL channels adjusted within 1 ns.

20131125

Page 36: Performance of  the  LHCb calorimeters during the period 2010-2012

HCAL E/p offline calibration

V CPAN Days - Xvc 36

If the offline accounting for the HCAL ageing will be found necessary, one can use the E/p based calibration on hadron tracks (for the moment, available per fill, up to fill #2007, Aug-2011).

The E/p calibration gives absolute scale and calibrates the whole signal chain, accounting also for the spread of FEB sensitivities.

Here: correlation of ratio of E/p-based calibration coefficients for fill ranges 1883-1901 and 1997-2007 (~5 weeks in between) and LED amplitude change for the same period. This validates the use of the LED corrections at least for short time scale.

20131125