PAVA—IP Audio Voice Alarm Router - Tyco Integrated …€¦ · · 2016-08-23tyco PAVA—IP...
Transcript of PAVA—IP Audio Voice Alarm Router - Tyco Integrated …€¦ · · 2016-08-23tyco PAVA—IP...
tyco
PAVA—IP Audio Voice
Alarm Router
tyco
PAVA Systems
The TYCO PAVA System provides
12 analogue audio inputs and 12
outputs, together with two Ethernet IP in
a 1U unit.
Up to four TYCO PAVA routers can be
ůŝŶŬĞĚƚŽƉƌŽǀ ŝĚĞƌŽƵƟŶŐĨƌŽŵĂŶLJŽƌĂůů
of their inputs to their outputs in a 48 by
ϰϴŵĂƚƌŝdžǁ ŚŝůĞĐŽŶŶĞĐƟŶŐƉĂŝƌƐŽĨ
TYCO PAVA systems enables dual
redundant ‘A’&‘B’ VA systems to be
constructed . The 20dBu output level
enables intelligent speaker systems to be
driven directly.
The audio inputs provide direct RJ45
ĐŽŶŶĞĐƟŽŶƐƚŽdzKD WĂŶĚD ^ŵŝĐƌŽͲ
phones, while two of the inputs provide
all-ĐĂůůŚĂƌĚǁ ĂƌĞďLJƉĂƐƐŽƉĞƌĂƟŽŶĞǀ ĞŶŝĨ
the DSP or CPU has failed.
Advanced energy management includes
the removal of power from paging
microphones during out of office periods
ĂŶĚĂƵƚŽŵĂƟĐĂůůLJƉŽǁ ĞƌŝŶŐĚŽǁ ŶƵŶƵƐĞĚ
ĨƵŶĐƟŽŶƐ
The full analogue and digital audio signal
path is of Pro-Sound quality with
ƉŽǁ ĞƌĨƵůĂƵĚŝŽĨƵŶĐƟŽŶƐ ŝŶĐůƵĚŝŶŐ
dynamic input processing and individually
adjustable digital output delay and para-
ŵĞƚƌŝĐĞƋƵĂůŝƐĂƟŽŶ
There are 12 selectable GPIO
digital / analogue contact inputs,
12 digital outputs, and two relay
outputs built in, while BMB01
Remote I/O units can be used to
ƉƌŽǀ ŝĚĞĂĚĚŝƟŽŶĂůŝŶƚĞƌĨĂĐĞƐ
TYCO Sample and Hold sensors
can be used on analogue contact
inputs, while the analogue audio
inputs provide Dynamic Ambient
E ŽŝƐĞ ĞŶƐŽƌ;E ^ͿĐŽŶŶĞĐƟŽŶƐ
for control of up to four outputs.
dŚĞŽƉƟŽŶĂůE dŵŽĚƵůĞĞŶĂďůĞƐ
ŵƵůƟ-channel Ethernet
ĐŽŶŶĞĐƟŽŶƐƚŽĂƐŝƚĞŶĞƚǁ ŽƌŬ
and/or to local V1000 Voice
Alarm Amplifier mainframes. The
module also enables the
ĐŽŶƐƚƌƵĐƟŽŶŽĨĂƌĞĚƵŶĚĂŶƚĮ ďƌĞ
loop VA network with remote
TYCO PAVA routers.
Features :
// Pro-Sound quality
// Two RJ45 Ethernet IP ports
// 12 analogue audio inputs
// 12 dual A&B analogue audio outputs
// 20dBu output for intelligent speakers
// Advanced energy management
// 10 minutes of monitored messages
// Hardware bypass microphone ports
// GPIO : 12 inputs and 12 outputs
// Link up to four TYCO PAVA systems to
ƉƌŽǀ ŝĚĞĂϰϴďLJϰϴƌŽƵƟŶŐŵĂƚƌŝdž
// ƵĂůƌĞĚƵŶĚĂŶƚƌŽƵƟŶŐĐĂƉĂďŝůŝƚLJ
// EN54-16 compliant
KƉƟŽŶĂůD ŽĚƵůĞƐ
// TYCO-NET = 16 input and output au-
dio channels over IP with two RJ45 Ether-
net ports and two SFP Ethernet ports
Tel : +44(0) 115 904 04 04
Fax : +44(0) 115 9 77 03 70
ĞŵĂŝůƞŝƐ ǀ ŽŝĐĞƵŬΛ ƚLJĐŽŝŶƚ ĐŽŵDabell Avenue, Blenheim Industrial Estate,
Ƶůǁ ĞůůE Žƫ ŶŐŚĂŵ E ' ϲϴt
tyco
PAVA Systems
ŶĂůŽŐƵĞƵĚŝŽZŽƵƟŶŐKƵƚƉƵƚƐ
Use of the standard analogue audio
ŽƵƚƉƵƚƐĞŶĂďůĞƐŝŶƚĞŐƌĂƟŽŶŽĨƚŚĞ
TYCO PAVA with TYCO V400, X400, or
V1000 100V Amplifier Mainframes, or
with any other analogue audio
ĂŵƉůŝĮ ĐĂƟŽŶĞƋƵŝƉŵĞŶƚŝŶĐůƵĚŝŶŐůŽǁ
impedance Pro-Sound amplifiers.
Direct Digital IP Amplifier Wiring
RACK-IP - Direct Digital Amplifier
ŽŶŶĞĐƟŽŶ
The RJ45 Ethernet IP interfaces of
ƚŚĞŽƉƟŽŶĂůdLJĐŽ-NET
modules enable direct digital
drive of the TYCO PAVA
Amplifier Mainframes..
This enables a TYCO IP Audio
Router to be connected via a
single RJ45 patch lead loop
ĐŽŶŶĞĐƟŽŶƚŽƵƉƚŽƚŚŝƌƚLJ-two
Voice Alarm mainframes, with up
to three hundred and twenty
amplifiers, and providing up to
sixteen simultaneous broadcasts.
The daisy-required chain loop
ƌĂĐŬǁ ŝƌŝŶŐĐŽŶŶĞĐƟŽŶ
// Simplifies the system wiring
// Reduces rack wiring cost
// Reduces the number of audio
routers required
// Provides wiring redundancy
// ' ŝǀ ĞƐƚŚĞŽƉƟŽŶŽĨĚƵĂů
redundant routers
/ŵƉůĞŵĞŶƚĂƟŽŶKƉƟŽŶƐ
Distributed IP Networking
As well as local rack IP wiring, the
TYCO PAVA can be IP networked to
provide a large audio matrix across a
site, or across a region or country.
dŚŝƐĨƵŶĐƟŽŶĂůŝƚLJŝƐĂǀ ĂŝůĂďůĞŝŶƚŚĞ
standard unit, with two channels of
TYCO PMC IP Audio I/O which is
intended for use with a single
control centre, or in long line PA
ĂƉƉůŝĐĂƟŽŶƐ ĚĚŝŶŐĂdzK -NET
module provides sixteen global
network channels expand the system
ĨƵŶĐƟŽŶĂůŝƚLJƚŽĞŶĂďůĞůĂƌŐĞƐŝƚĞ
matrices to be constructed over IP,
as well as providing for IP
ĂŵƉůŝĮ ĞƌĐŽŶŶĞĐƟŽŶůŽĐĂůůLJdŚĞ
dzKWs /WĐŽŶŶĞĐƟŽŶƐĐĂŶďĞ
used to connect to third party IP
infrastructure, or the fibre interfaces
can be connected as a stand- alone
EN54 Voice Alarm fibre ring network
(TYCO-IP).
IP networked systems can be used
either with or without an overall
supervisory control system.
Tel : +44(0) 115 904 04 04
Fax : +44(0) 115 9 77 03 70
ĞŵĂŝůƞŝƐ ǀ ŽŝĐĞƵŬΛ ƚLJĐŽŝŶƚ ĐŽŵDabell Avenue, Blenheim Industrial Estate,
Ƶůǁ ĞůůE Žƫ ŶŐŚĂŵ E ' ϲϴt
tycoPAVA— EN54-16 COMPLIANT
PAVA AMPLIFIER FRAME AND
MODULES
tyco
PAVA Systems
The Tyco PAVA Amplifier frame provides
the housing, signal and data
ŝŶƚĞƌĐŽŶŶĞĐƟŽŶ ŵŽŶŝƚŽƌŝŶŐĂŶĚƉŽǁ Ğƌ
supplies for the Tyco PAVA range of
power amplifier modules and their
interface cards.
This amplifier frame can house a range of
ĐŽŵďŝŶĂƟŽŶƐŽĨĂŵƉůŝĮ ĞƌŵŽĚƵůĞƐŝŶƚŚĞ
following format :
4 x 100 W, 2 x 200 W, 1 x 400 W, or 2 x
100 W + 1 x 200 W.
Amplifier modules are inserted from the
front of the frame and are protected by a
front panel chosen to suit the
ĐŽŶĮ ŐƵƌĂƟŽŶŽĨĂŵƉůŝĮ ĞƌƚLJƉĞƐƵƐĞĚ
Interface cards (which may also serve line
surveillance and standby amplifier
Ɛǁ ŝƚĐŚŽǀ ĞƌĨƵŶĐƟŽŶƐͿĂƌĞŝŶƐĞƌƚĞĚĨƌŽŵ
the rear of the mainframe to connect to
the amplifier modules.
The mainframe is designed to operate
with dual power supplies: 230 V AC mains
ƐƵƉƉůLJĂŶĚϮϰs ďĂƩ ĞƌLJƐƵƉƉůLJ
The full 400 W power is available
ƌŝŐŚƚĚŽǁ ŶƚŽϮϭs ďĂƩ ĞƌLJƐƵƉƉůLJ
voltage.
The frame, its amplifiers and
interface cards are monitored
and controlled by the Tyco PAVA
Controller.
Any faults occurring in the
amplifier Any faults occurring in
the amplifier system will be
reported, recorded, and
displayed by the Controller.
Features :
// Class D Rated Amplifiers provides
80% efficiency.
// The unique design negates the need
to ‘sleep’ the amplifiers when in
quiescent state.
// ŝī ĞƌĞŶƚWŽǁ ĞƌKƉƟŽŶƐϭϬϬϮϬϬ
ŽƌϰϬϬǁ ĂƩ ǀ ĂƌŝĂŶƚƐ
// Improved efficiency and reduced
ŚĞĂƚĚŝƐƐŝƉĂƟŽŶ
// 100 Hz − 18 kHz (±3 dB) Frequency Response.
// The Amplifier Mainframe can carry
various amplifier types, and carries
interface cards which contain the
amplifier’s monitoring electronics
Tel : +44(0) 115 904 04 04
Fax : +44(0) 115 9 77 03 70
ĞŵĂŝůƞŝƐ ǀ ŽŝĐĞƵŬΛ ƚLJĐŽŝŶƚ ĐŽŵDabell Avenue, Blenheim Industrial Estate,
Ƶůǁ ĞůůE Žƫ ŶŐŚĂŵ E ' ϲϴt
tyco
PAVA Systems
ŵƉůŝĮ ĞƌKƉƟŽŶƐ
Tel : +44(0) 115 904 04 04
Fax : +44(0) 115 9 77 03 70
ĞŵĂŝůƞŝƐ ǀ ŽŝĐĞƵŬΛ ƚLJĐŽŝŶƚ ĐŽŵDabell Avenue, Blenheim Industrial Estate,
Ƶůǁ ĞůůE Žƫ ŶŐŚĂŵ E ' ϲϴt
T100
100 WATT
KƵƚƉƵƚWŽǁ ĞƌϭϬϬt ;Λ ϭϬϬs ZD ^ĚŽǁ ŶƚŽϮϭs ďĂƩ ĞƌLJƐƵƉƉůLJͿ
KƵƚƉƵƚs ŽůƚĂŐĞĂŶĚ/ŶƉƵƚƐĞŶƐŝƟǀ ŝƚLJϭϬϬs ZD ^
Efficiency : 80%
Frequency Response : 100 Hz − 18 kHz (±3 dB)
dŽƚĂů, ĂƌŵŽŶŝĐŝƐƚŽƌƟŽŶ- <0.5%
T200
200 WATT
KƵƚƉƵƚWŽǁ ĞƌϮϬϬt ;Λ ϭϬϬs ZD ^ĚŽǁ ŶƚŽϮϭs ďĂƩ ĞƌLJƐƵƉƉůLJͿ
KƵƚƉƵƚs ŽůƚĂŐĞĂŶĚ/ŶƉƵƚƐĞŶƐŝƟǀ ŝƚLJϭϬϬs ZD ^
Efficiency : 80%
Frequency Response : 100 Hz − 18 kHz (±3 dB)
dŽƚĂů, ĂƌŵŽŶŝĐŝƐƚŽƌƟŽŶ- <0.5%
T400
400 WATT
KƵƚƉƵƚWŽǁ ĞƌϰϬϬt ;Λ ϭϬϬs ZD ^ĚŽǁ ŶƚŽϮϭs ďĂƩ ĞƌLJƐƵƉƉůLJͿ
KƵƚƉƵƚs ŽůƚĂŐĞĂŶĚ/ŶƉƵƚƐĞŶƐŝƟǀ ŝƚLJϭϬϬs ZD ^
Efficiency : 80%
Frequency Response : 100 Hz − 18 kHz (±3 dB)
dŽƚĂů, ĂƌŵŽŶŝĐŝƐƚŽƌƟŽŶ- <0.5%
V400
MODULAR
AMPLIFIER
FRAME
dŚĞs ϰϬϬŵƉůŝĮ ĞƌD ĂŝŶĨƌĂŵĞƉƌŽǀ ŝĚĞƐƚŚĞŚŽƵƐŝŶŐƐŝŐŶĂůĂŶĚĚĂƚĂŝŶƚĞƌĐŽŶŶĞĐƟŽŶ
monitoring electronics, and power supplies for the Tyco range of power amplifier modules
and their interface cards.
dŚŝƐĨƌĂŵĞĐĂŶŚŽƵƐĞĂŶLJŽĨƚŚĞĨŽůůŽǁ ŝŶŐĨŽƵƌĐŽŵďŝŶĂƟŽŶƐŽĨĂŵƉůŝĮ ĞƌŵŽĚƵůĞƐ
4 x 100 W, 2 x 200 W, 1 x 400 W, or 2 x 100 W + 1 x 200 W.
tyco
tyco
PAVA Systems
MPS01 - MPS50
Zoneable Microphones
// The microphones will also operate in a hardware
bypass fall-back mode in the event of failure within
a PAVA Controller.
// All interconnect cabling and the microphone
ĐĂƉƐƵůĞŝƐĐŽŶƟŶƵŽƵƐůLJŵŽŶŝƚŽƌĞĚ
// As well as the main microphone gooseneck, there
ĂƌĞϯ ϱŵŵũĂĐŬƉůƵŐĐŽŶŶĞĐƟŽŶƐĨŽƌĂŶĂƵdžŝůŝĂƌLJ
audio input, such as for background music, and for
ĐŽŶŶĞĐƟŽŶŽĨĂŵŝĐƌŽƉŚŽŶĞŚĞĂĚƐĞƚ ŐĞŶĞƌĂů
purpose local contact input and output enables use
with PTT foot switches and external speak now
indicators.
// A local speaker is provided on the underside of
the console, and this enables preview of the locally
stored DVA messages, and also enables remote PA
zones to be listened to.
// ůůĐĂďůĞĞŶƚƌŝĞƐĂƌĞƵŶĚĞƌĂƉƌŽƚĞĐƟǀ ĞƐƚƌĂŝŶ
relieving cover on the underside of the microphone,
and all interconnect cables and the gooseneck
microphone are replaceable to simplify
maintenance.
Tel : +44(0) 115 904 04 04
Fax : +44(0) 115 9 77 03 70
ĞŵĂŝůƞŝƐ ǀ ŽŝĐĞƵŬΛ ƚLJĐŽŝŶƚ ĐŽŵDabell Avenue, Blenheim Industrial Estate,
Ƶůǁ ĞůůE Žƫ ŶŐŚĂŵ E ' ϲϴt
dŚĞdLJĐŽƌĂŶŐĞŽĨD ŝĐƌŽƉŚŽŶĞƐƚĂƟŽŶƐ
are powerful and flexible paging
microphones which can provide live,
store-and-forward, and recorded message
broadcast into user selected zones, and
also provide EN54 compliant emergency
ĨƵŶĐƟŽŶƐĂŶĚĂůůE ϱϰŵĂŶĚĂƚŽƌLJ
indicators and controls.
Main Features :
// The units each consist of a Main Desk
console with a flexible gooseneck paging
microphone, graphic LCD display, and silent
ŽƉĞƌĂƟŽŶdŽƵĐŚƚŽdĂůŬƚŽƵĐŚƉĂĚWdd
ďƵƩ ŽŶ ƚŽŐĞƚŚĞƌǁ ŝƚŚŽŶĞŽƌŵŽƌĞĂĚĚŝƟŽŶĂů
njŽŶĞƐĞůĞĐƟŽŶĂŶĚĐŽŶƚƌŽůďƵƩ ŽŶ
modules.
// dŚĞŶƵŵďĞƌŽĨĂĚĚŝƟŽŶĂůďƵƩ ŽŶƐĐĂŶďĞ
ĨƌŽŵϭϬƚŽϱϬĞdžƚƌĂ ĞůĞĐƚďƵƩ ŽŶƐ
// WnjŽŶĞƐĞůĞĐƟŽŶŝƐƉƌŽǀ ŝĚĞĚďLJƚŚĞ ĞůĞĐƚ
ďƵƩ ŽŶƐŽƌďLJƵƐŝŶŐƚŚĞƌŽƚĂƌLJƐĞůĞĐƚŽƌĂŶĚ
graphic LCD display.
There is also a VU bar graph which displays the
microphone signal level.
// dŚĞdLJĐŽƌĂŶŐĞŚĂƐŵƵůƟƉůĞƐLJƐƚĞŵ
interfaces, and can be connected directly to
either one or two Tyco PAVA Controllers.
// There is also an RJ45 Ethernet IP interface
ǁ ŝƚŚWŽǁ ĞƌŽǀ ĞƌƚŚĞƌŶĞƚĨŽƌĐŽŶŶĞĐƟŽŶƚŽ
the Tyco IP PA/VA system.
tyco
PAVA Systems
// RANGE OF STATION CONFIGURATIONS :
D ŝĐƌŽƉŚŽŶĞĂƐĞ ƚĂƟŽŶ
D ŝĐƌŽƉŚŽŶĞ ƚĂƟŽŶǁ ŝƚŚ
ϭϬďƵƩ ŽŶŵŽĚƵůĞ
D ŝĐƌŽƉŚŽŶĞ ƚĂƟŽŶǁ ŝƚŚ
ϯϬďƵƩ ŽŶŵŽĚƵůĞ
D ŝĐƌŽƉŚŽŶĞ ƚĂƟŽŶǁ ŝƚŚ&ŝƐƚ
D ŝĐƌŽƉŚŽŶĞKƉƟŽŶ
Tel : +44(0) 115 904 04 04
Fax : +44(0) 115 9 77 03 70
ĞŵĂŝůƞŝƐ ǀ ŽŝĐĞƵŬΛ ƚLJĐŽŝŶƚ ĐŽŵDabell Avenue, Blenheim Industrial Estate,
Ƶůǁ ĞůůE Žƫ ŶŐŚĂŵ E ' ϲϴt
tyco
tyco
PAVA Systems
EMS10 - EMS50
Zoneable Emergency
Microphones
The EMS10, EMS20 and EMS50
ŵĞƌŐĞŶĐLJD ŝĐƌŽƉŚŽŶĞ ƚĂƟŽŶƐĂƌĞ
E ϱϰĐŽŵƉĂƟďůĞĞŵĞƌŐĞŶĐLJ
microphones which provide live and
pre-recorded message broadcast into
user selected zones.
dŚĞD ^ϭϬƉƌŽǀ ŝĚĞƐϭϬďƵƩ ŽŶƐĞůĞĐƟŽŶ
capability whilst the EMS20 provides 20
ďƵƩ ŽŶƐ ĂŶĚƚŚĞD ^ϱϬŝƐĨŽƌŵĞĚĨƌŽŵ
ĂϮϬďƵƩ ŽŶD ^ϮϬƚŽŐĞƚŚĞƌǁ ŝƚŚĂŶ
ĂĚĚŝƟŽŶĂůϯϬďƵƩ ŽŶD yϯϬĞdžƉĂŶƐŝŽŶ
unit. All microphones also provide EN54
ĐŽŵƉůŝĂŶƚĞŵĞƌŐĞŶĐLJĨƵŶĐƟŽŶƐĂŶĚĂůů
EN54 mandatory indicators and con-
trols.
The microphones are housed in a locka-
ble wall-ŵŽƵŶƟŶŐďŽdžĂŶĚĨĞĂƚƵƌĞĂ
graphic LCD display together with
indicators for ‘Power’, ‘Voice Alarm’,
‘System Fault’, ‘Fault’ and ‘Speak Now’.
The LCD display provides remote access
ƚŽƚŚĞůŝƐƚŽĨĂĐƟǀ ĞĨĂƵůƚƐŝŶƚŚĞW s
system, while the EN54 mandated
ĐŽŶƚƌŽůŬĞLJƐĞŶĂďůĞŶĂǀ ŝŐĂƟŽŶƚŚƌŽƵŐŚ
the fault list, and also provide remote
fault acceptance and clearance.
dŚĞŵŝĐƌŽƉŚŽŶĞƐŚĂǀ ĞŵƵůƟƉůĞW s
system interfaces and can be connected
directly to either one or two TYCO audio
ƌŽƵƚĞƌƐ ĞŶĂďůŝŶŐŵƵůƟƉůĞŽƉƟŽŶƐĨŽƌ
system redundancy.
The microphones will operate in an
All- Call hardware bypass fall back mode
even in the event of processor failure
within the host Voice Alarm Router .
dŚŝƐŚĂƌĚǁ ĂƌĞďLJƉĂƐƐĨƵŶĐƟŽŶĂůƐŽ
ŽƉĞƌĂƚĞƐĂĐƌŽƐƐǁ ŚŽůĞĨĂĐŝůŝƟĞƐǁ ŚĞŶƚŚĞ
ŵŝĐƌŽƉŚŽŶĞƐĂƌĞƵƐĞĚŝŶĐŽŶũƵŶĐƟŽŶǁ ŝƚŚ
TYCO’s safety audio network.
There is also a non-EN54 RJ45 Ethernet IP
interface with Power over Ethernet
ĐĂƉĂďŝůŝƚLJĨŽƌs Ž/WĐŽŶŶĞĐƟŽŶƐƚŽdzK/W
based PA/VA systems.
All interconnect cabling and the
ŵŝĐƌŽƉŚŽŶĞĐĂƉƐƵůĞŝƐĐŽŶƟŶƵŽƵƐůLJ
monitored for open and short circuits.
dŽƉ ďŽƩ ŽŵĂŶĚƌĞĂƌĐĂďůĞĞŶƚƌLJƉŽŝŶƚƐ
are provided by means of ‘knock-outs’ in
ƚŚĞĞŶĐůŽƐƵƌĞǁ ŚŝůĞƚŚĞĮ ĞůĚĐŽŶŶĞĐƟŽŶƐ
are provided by means of a set of
terminals on the inside rear panel of the
back box.
Features
// Wall Mount Fist Microphones
// ϭϬϮϬŽƌϱϬ ĞůĞĐƟŽŶƵƩ ŽŶƐ
// EN54 Compliant Indicators and Controls
// EN54 Fault List Display
// Speech Level ‘VU’ Bar graph
// Fully Monitored
// , ĂƌĚǁ ĂƌĞLJƉĂƐƐ&ĂůůďĂĐŬKƉĞƌĂƟŽŶ
// Dual Redundant Outputs for A & B Routers
// ĚĚŝƟŽŶĂůs ŽŝĐĞŽǀ Ğƌ/W/ŶƚĞƌĨĂĐĞǁ ŝƚŚ
PoE RJ45 Ethernet Port (With IP License)
i) Hardware bypass is provided on TYCO
Voice Alarm Router inputs 1 and 2. If
connected to any other router input ports
then the EMS10, EMS20, and EMS50 will
ŽƉĞƌĂƚĞŶŽƌŵĂůůLJďƵƚǁ ŝƚŚŽƵƚƚŚŝƐĨƵŶĐƟŽŶ
Ii) /W/ŶƚĞƌĨĂĐĞĨƵŶĐƟŽŶĂůŝƚLJŝƐĞŶĂďůĞĚĨŽƌƚŚĞ
EMSxx-/Wǀ ĂƌŝĂŶƚƐ ǁ ŝƚŚĂŶĂĚĚŝƟŽŶĂů/W
ůŝĐĞŶƐĞE ŽƚĞƚŚĂƚƚŚŝƐĨƵŶĐƟŽŶĂůŝƚLJŝƐŶŽƚ
EN54 compliant.
iii) The EMS10, EMS20, and EMS50 EN54
compliant and EN54 fault display
ĨƵŶĐƟŽŶĂůŝƚLJŝƐƐƵƉƉŽƌƚĞĚďLJƚŚĞdzK
PAVA IP Audio Router,
Tel : +44(0) 115 904 04 04
Fax : +44(0) 115 9 77 03 70
ĞŵĂŝůƞŝƐ ǀ ŽŝĐĞƵŬΛ ƚLJĐŽŝŶƚ ĐŽŵDabell Avenue, Blenheim Industrial Estate,
Ƶůǁ ĞůůE Žƫ ŶŐŚĂŵ E ' ϲϴt
tyco
PAVA Systems
D ŝĐƌŽƉŚŽŶĞKƉƟŽŶƐ
The base product of the EMS
microphone range is the All-Call EMS 01.
This Product Overview describes the
extended variants in the range. These
ƵŶŝƚƐŚĂǀ ĞƵƉƚŽĮ ŌLJŐĞŶĞƌĂůƉƵƌƉŽƐĞ
ƉƌŽŐƌĂŵŵĂďůĞƐĞůĞĐƚďƵƩ ŽŶƐ ĞĂĐŚ
ŝĚĞŶƟĮ ĞĚďLJŵĞĂŶƐŽĨĂůĂďĞůǁ ŚŝĐŚŝƐ
protected under a clip-in cover.
EMS01 Emergency Microphone
EMS10 Emergency Microphone
EMS50 Emergency Microphone
-/WKƉƟŽŶǁ ŝƚŚ/W/ŶƚĞƌĨĂĐĞ>ŝĐĞŶƐĞ
The EMS Microphone’s built-in RJ45
Ethernet IP port is enabled with the
ĂĚĚŝƟŽŶŽĨƚŚĞ/WŝŶƚĞƌĨĂĐĞůŝĐĞŶƐĞ
Note that this interface is not EN54
compliant.
-KƉƟŽŶǁ ŝƚŚƵƌŽĐLJůŝŶĚĞƌ
Door Lock
The standard door lock can be re-
placed with a door which mounts a
ƵƌŽĐLJůŝŶĚĞƌůŽĐŬĨŽƌĂƉƉůŝĐĂƟŽŶƐ
where improved security is required
on the EMS door
/ŶƚĞƌĐŽŶŶĞĐƟŽŶKƉƟŽŶƐ
dŚĞD ^ŵŝĐƌŽƉŚŽŶĞƌĂŶŐĞŚĂƐŵƵůƟƉůĞ
PA/VA system interfaces, with the
physical interfaces formed of terminals
located in the inner rear face of the back
ďŽdždŚĞƐĞƉƌŽǀ ŝĚĞĐŽŶŶĞĐƟŽŶƐĂƐ
follows:
// Dual ‘Router Microphone Ports’
// Analogue Microphone Audio
// Z^ϰϴϱŽŵŵƵŶŝĐĂƟŽŶƐ
// DC Power Supply
// ‘Router Microphone Auxiliary Port’
// Hardware Bypass Emergency
D ŝĐƌŽƉŚŽŶĞŽŶŶĞĐƟŽŶƐĨŽƌďŽƚŚ
single and dual Routers
// USB Port
// ^ŽŌǁ ĂƌĞĂŶĚŽŶĮ ŐƵƌĂƟŽŶhƉĚĂƚĞ
// Ethernet Port
// RJ45 IP Network Port with PoE
// Built-In VoIP Interfacing (with license)
Tel : +44(0) 115 904 04 04
Fax : +44(0) 115 9 77 03 70
ĞŵĂŝůƞŝƐ ǀ ŽŝĐĞƵŬΛ ƚLJĐŽŝŶƚ ĐŽŵDabell Avenue, Blenheim Industrial Estate,
Ƶůǁ ĞůůE Žƫ ŶŐŚĂŵ E ' ϲϴt
EMS20 Emergency Microphone