Modularized Ultra-Filtration System Application conditions: Filtration type Inside-out Dead-end Suggested feed pressure 0.3MPa Suggested TMP 0.20.8bar Working temperature 40 0 C pH range 213 Feed-in turbidity 20NTU Voltage 220/380V, 50Hz Membrane performance: Membrane type Hollow fiber Fiber ID/OD 1.0/1.6mm Nominal pore size 0.01μm MWCO range 50,000Dalton Permeate turbidity 0.1NTU E-coli removal rate 99.999999% Virus removal rate 99.9999%

Transcript of Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D...

Page 1: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

Modularized Ultra-Filtration System

Application conditions: Filtration type Inside-out Dead-end Suggested feed pressure ≤0.3MPa Suggested TMP 0.2~0.8bar Working temperature ≤400C pH range 2~13 Feed-in turbidity ≤20NTU Voltage 220/380V, 50Hz

Membrane performance: Membrane type Hollow fiber Fiber ID/OD 1.0/1.6mm Nominal pore size 0.01μm MWCO range 50,000Dalton Permeate turbidity ≤0.1NTU E-coli removal rate ≥99.999999% Virus removal rate ≥99.9999%

Page 2: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

Overview of D series:

Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane module LH3-1060-V Litree UF system Configuration:

Item Specifications Qty Optional Membrane Module LH3-1060-V/LH3-0650-V PCS UF Skid Painted carbon steel 1SET SUS304/316 Automatic Valves Electrically operated 5PCS Pneumatic Flow meter Pipeline type 2PCS Electromagnetic Pressure gauge Oil filled gauge 4PCS Pressure sensor Control system PLC 1SET Pipeline UPVC 1SUIT CIP dosing system For maintenance cleaning 1SET

Notice: 1. Clean air source should be provided by user if pneumatic valves chosen. 2. The standard configuration of LG1060×24-D~LG1060×30-D is electromagnetic vavle and pressure sensor, not pipeline flowmeter and oil filled gauge.

Page 3: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

No. Model Design flux

(m3/h)

Backwash

flux (m3/h)

Dimension (mm)

L*W*H

Weight

Dry/Wet (KG)

1 LG0650×12-D 6-12 21 2570×1100×2000 550/780

2 LG0650×14-D 7-14 24.5 2800×1100×2000 600/830

3 LG0650×16-D 8-16 28 3120×1100×2000 650/950

4 LG0650×18-D 9-18 31.5 3350×1100×2000 700/1020

5 LG0650×20-D 10-20 35 3580×1100×2000 750/1100

6 LG1060×4-D 8-12 28 1850×1000×2180 380/680

7 LG1060×6-D 12-18 42 2160×1000×2200 520/1000

8 LG1060×8-D 16-24 56 2160×1000×2200 650/1250

9 LG1060×10-D 20-30 70 2895×1000×2225 820/1580

10 LG1060×12-D 24-36 84 3395×1000×2355 980/1880

11 LG1060×14-D 28-42 98 3705×1350×2355 1160/2200

12 LG1060×16-D 32-48 112 4115×1350×2400 1320/2320

13 LG1060×18-D 36-54 126 4365×1350×2400 1560/2900

14 LG1060×20-D 40-60 140 4675×1350×2400 1680/3200

15 LG1060×24-D 48-72 168 5895×1350×2440 1820/3650

16 LG1060×26-D 52-78 182 6205×1350×2440 1960/3900

17 LG1060×28-D 56-84 196 6515×1350×2440 2110/4200

18 LG1060×30-D 60-90 210 6825×1350×2440 2230/4500

Notice: Design flux depends on raw water quality.

Specifications on Page6~18.

Page 4: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

Overview of Economical series:

Model: LG 0650 × 8 - E E series standard system Module quantity Membrane module LH3-0650-V Litree UF system Configuration:

Item Specifications Qty Optional Membrane Module LH3-1060-V/LH3-0650-V PCS UF Skid SUS304 1SET Automatic Valves Electrically operated 5PCS Pneumatic Flow meter Pipeline type 2PCS Electromagnetic Pressure gauge Oil filled gauge 4PCS Pressure sensor Control system PLC + Touch screen 1SET Pipeline UPVC 1SUIT Backwash pump SUS304 1SET Backwash filter Bag filter 1PC Feed pump filter Bag filter 1PC

Notice: Clean air source should be provided by user if pneumatic valves chosen.

Page 5: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

No. Model Design flux

(m3/h) Backwash flux (m3/h)

Dimension (mm)

L*W*H

Weight

Dry/Wet (KG)

1 LG0650×2-E 1.0-2.0 3.5 975×880×1750 260/300

2 LG0650×3-E 1.5-3.0 5.25 1220×880×1750 280/340

3 LG0650×4-E 2.0-4.0 7 1465×880×1750 300/380

4 LG0650×6-E 3.0-6.0 10.5 1875×850×1850 350/470

5 LG0650×8-E 4.0-8.0 14 2350×910×1900 390/550

6 LG1060×10-E 5-10 17.5 2580×910×1900 430/630

Notice: Design flux depends on raw water quality.

Page 6: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

Specifications of D series system

LG1060×4-D

Connector size: Feed inlet DN50 CIP inlet DN50 Permeate outlet DN50 CIP outlet DN50 Backwash inlet DN80 Air test inlet DN15 Discharge DN80

Page 7: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

LG1060×6-D

Connector size: Feed inlet DN50 CIP inlet DN50 Permeate outlet DN50 CIP outlet DN50 Backwash inlet DN100 Air test inlet DN15 Discharge DN100

Page 8: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

LG1060×8-D

Connector size: Feed inlet DN65 CIP inlet DN65 Permeate outlet DN65 CIP outlet DN65 Backwash inlet DN125 Air test inlet DN15 Discharge DN125

Page 9: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

LG1060×10-D

Connector size: Feed inlet DN80 CIP inlet DN80 Permeate outlet DN80 CIP outlet DN80 Backwash inlet DN125 Air test inlet DN15 Discharge DN125

Page 10: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

LG1060×12-D

Connector size: Feed inlet DN80 CIP inlet DN80 Permeate outlet DN80 CIP outlet DN80 Backwash inlet DN125 Air test inlet DN15 Discharge DN125

Page 11: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

LG1060×14-D

Connector size: Feed inlet DN80 CIP inlet DN80 Permeate outlet DN80 CIP outlet DN80 Backwash inlet DN150 Air test inlet DN15 Discharge DN150

Page 12: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

LG1060×16-D

Connector size: Feed inlet DN100 CIP inlet DN100 Permeate outlet DN100 CIP outlet DN100 Backwash inlet DN150 Air test inlet DN15 Discharge DN150

Page 13: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

LG1060×18-D

Connector size: Feed inlet DN100 CIP inlet DN100 Permeate outlet DN100 CIP outlet DN100 Backwash inlet DN150 Air test inlet DN15 Discharge DN150

Page 14: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

LG1060×20-D

Connector size: Feed inlet DN100 CIP inlet DN100 Permeate outlet DN100 CIP outlet DN100 Backwash inlet DN150 Air test inlet DN15 Discharge DN150

Page 15: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

LG1060×24-D

Connector size: Feed inlet DN125 CIP inlet DN125 Permeate outlet DN125 CIP outlet DN125 Backwash inlet DN200 Air test inlet DN15 Discharge DN200

Page 16: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

LG1060×26-D

Connector size: Feed inlet DN125 CIP inlet DN125 Permeate outlet DN125 CIP outlet DN125 Backwash inlet DN200 Air test inlet DN15 Discharge DN200

Page 17: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

LG1060×28-D

Connector size: Feed inlet DN125 CIP inlet DN125 Permeate outlet DN125 CIP outlet DN125 Backwash inlet DN200 Air test inlet DN15 Discharge DN200

Page 18: Modularized Ultra-Filtration Systemlaval.in.ua/_files/doc/litree_uf_system_d_series.pdfOverview of D series: Model: LG 1060 × 1 8 - D D series standard system Module quantity Membrane

LG1060×30-D

Connector size: Feed inlet DN125 CIP inlet DN125 Permeate outlet DN125 CIP outlet DN125 Backwash inlet DN200 Air test inlet DN15 Discharge DN200