Installation examplesM
odular
sys
tems
for energ
y ma
nage
ment
HW60/125-04 DN 25
M2 MIX3DN 25
M2DN 25
HV60/125 SG-2 DN 25
SG 50
30 kWΔt 20 K
1.290 L/h
20 kWΔt 20 K860 L/h
Attention: the representations are to be considered just as an indication and they have no completeness pretension.
Heat source: gas boiler.Supply from heat source:unmixed pump unit M2 DN25; Δt 20 K.Distribution:- Hydraulic switcher HW 60/125-04 DN25;- Heating distributor HV 60/125-SG2 DN25 for 2 pump units with security unit SG 50 and expansion vessel.Heating users:- Medium power radiator line, Δt 20 K:unmixed pump unit M2 DN25;- High power radiator line, Δt 20 K:mixed pump unit M2 MIX3 DN25.
647P
Fixing bracketSet 648
SET F
LEX 5
0
629SET
50 kWΔt 20 K
2.150 L/h
Wall fixing setDAOA25SET
0266/M
128525(28 mm)
Optional connections:- Copper pipe connections (18, 22 and 28 mm)- Isolating valves 0266/M
Supportbracket
DAOA25SET
- 2 - http://www.brv.it email: [email protected]
Installation examples
M2DN 25
M2 MIX3DN 25
M2 FIX3DN 25
10 kWΔt 20 K430 L/h
10 kWΔt 20 K430 L/h
10 kWΔt 8 K
1.080 L/h
Heat source: solid fuel boiler.Buffer tank loading from the boiler:Version 1:employment of anti-condensing pump unitMCCS DN25; Δt 20 K;Version 2:employment of anti-condensing recycling pump unitM2 FIX3 CS DN25; Δt 20 K;Distribution:Heating distributor HV 60/125 DN25 for 3 pump units.Heating users:- Low power radiator line, Δt 20 K:unmixed pump unit M2 DN25;- Low power radiator line, Δt 20 K:mixed pump unit M2 MIX3 DN25;- Low power under floor heating line, Δt 8 K:fixed temperature pump unit M2 FIX3 DN25.
HV60/125-3 DN 25
Attention: the representations are to be considered just as an indication and they have no completeness pretension.
M2 FI
X3 CS
DN 2530 kW
Δt 20 K1.290 L/h
Version 1 Version 2
30 kWΔt 20 K
1.290 L/h
MCCS
DN 25
Wall fi
xing s
etDA
OA25
SET
- 3 - http://www.brv.it email: [email protected]
Installation examples
M2DN 25
M2 MIX3DN 25
M2 FIX3DN 25
M2 MIX33DN 25
HV70/125-4 DN 25
10 kWΔt 20 K430 L/h
10 kWΔt 20 K430 L/h
10 kWΔt 8 K
1.080 L/h
20 kWΔt 15 K
1.150 L/h
Heat source: solid fuel boiler.Buffer tank loading from the boiler: anti-condensing pump unit M2 MIX3 CS DN25; Δt 20 K.Distribution: heating distributor HV 70/125 DN25 for 4 pump units.Heating users:- Low power radiator line, Δt 20 K: unmixed pump unit M2 DN25;- Low power radiator line, Δt 20 K: mixed pump unit M2 MIX3 DN25;- Low power under floor heating line, Δt 8 K: fixed temperature pump unit M2 FIX3 DN25;- Medium power under floor heating line, Δt 15 K: mixed pump unit M2 MIX33 DN25.
Attention: the representations are to be considered just as an indication and they have no completeness pretension.
M2 M
IX3 CS
DN 25
50 kWΔt 20 K
2.150 L/h
Wall fi
xing s
etDA
OA25
SET
- 4 - http://www.brv.it email: [email protected]
Installation examples
Heat source: gas boiler.Supply from heat source:unmixed pump unit M2 DN32; Δt 20 K.Distribution:- Hydraulic switcher HW 60/125-05 DN25;- Heating distributor HV 70/125 DN25 for 5 pump units.HDW tank loading: unmixed pump unit M2 DN25; Δt 20 K.Heating users:- Low power radiator line, Δt 20 K:mixed pump unit M2 MIX3 DN25;- Low power under floor heating line, Δt 8 K:fixed temperature pump unit M2 FIX3 DN25;- Low power under floor heating line, Δt 15 K:mixed pump unit M2 MIX33 DN25;- High power radiator line, Δt 20 K:mixed pump unit with electronic control for constanttemperature M2 MIX3 FIX DN32.
Attention: the representations are to be considered just as an indication and they have no completeness pretension.
M2 MIX3DN 25
M2 FIX3DN 25
M2 MIX33DN 25
M2 MIX3 FIXDN 32
M2DN 25
M2DN 25
HW60/125-05 DN 25
HV70/125-5 DN 25
70 kWΔt 20 K
3.000 L/h
10 kWΔt 20 K430 L/h
10 kWΔt 8 K
1.080 L/h
10 kWΔt 15 K570 L/h
40 kWΔt 20 K
1.720 L/h
10 kWΔt 20 K430 L/h
629SET
Wall fixing setDAOA25SET
- 5 - http://www.brv.it email: [email protected]
Installation examples
20 kWΔt 20 K860 L/h
10 kWΔt 20 K430 L/h
10 kWΔt 8 K
1.080 L/h
CLIM
A3
DN 25
M2 M
IX3DN
25
M2 FI
X3DN
25
M2 M
IX33
DN 25
M2 M
IX3 FI
XDN
25
10 kWΔt 15 K570 L/h
10 kWΔt 20 K430 L/h
20 kWΔt 8 K
2.160 L/h
M2 M
IX3 CS
DN 32
M2 Ex
chan
ge D
N 25
M2 D
N 25
Modv
Fresh
3
Solo 2High Efficiency
S2 So
lar 30
S2 Ex
chan
geM2
DN 2
5
HV70/125-6 DN 25
Heat source: solid fuel boiler.Buffer tank loading from the boiler: anti-condensing pump unit M2 MIX3 CS DN32; Δt 20 K.Buffer tank loading from the solar system:Version 1: employment of a solar thermal pump unit S2 Solar 30 and of an unmixed pump unit M2 DN25, with the interposition of a heat exchange unit S2 Exchange.Version 2: employment of a solar thermal pump unit Solo 2 High Efficiency for stratified loading.HDW users: ModvFresh 3 pump unit with recycling line.Distribution: heating distributor HV 70/125 DN25 for 6 pump units.Heating users:- Medium power radiator line, Δt 20 K: mixed pump unit CLIMA 3 DN25;- Low power radiator line, Δt 20 K: mixed pump unit M2 MIX3 DN25;- Low power under floor heating line, Δt 8 K: fixed temperature pump unit M2 FIX3 DN25;- Low power under floor heating line, Δt 15 K: mixed pump unit M2 MIX33 DN25;- Low power radiator line, Δt 20 K: mixed pump unit with electronic control for constant temperature M2 MIX3 FIX DN25;- Medium power wall radiant heating line, Δt 8 K: employment of a heat exchange unit M2 Exchange to separate from the hydraulic point of view the users line (to keep the piping clean). Unmixed pump unit M2 DN25 on the primary line and mixed pump unit M2 MIX3 Energy G21 DN25 on the secondary line, to meter the produced energy.
Version 1 Version 2
Attention: the representations are to be considered just as an indication and they have no completeness pretension.
Modv
Sol e
xpan
sion v
esse
l
Modv
Sol e
xpan
sion v
esse
l
M2 M
IX3 En
ergy G
21 D
N 25
80 kWΔt 20 K
3.450 L/h
M2 M
IX3 CS
DN 32
Wall fi
xing s
etDA
OA32
SET
Fixing bracketSet 648
- 6 - http://www.brv.it email: [email protected]
Installation examples
Attention: the representations are to be considered just as an indication and they have no completeness pretension.
Heat source: gas boiler and heat pump.Supply from heat source: unmixed pump unit M2 DN32; Δt 20 K.Supply from heat pump: unmixed pump unit M2 DN25; Δt 20 K.Distribution:- Hydraulic switcher HW 80/125 DN32 with security unit SG 200;- Heating distributor: HV 80/125 DN32 for 4 pump units.HDW tank loading: unmixed pump unit M2 DN25; Δt 20 K.Heating users:- High power radiator line, Δt 20 K: mixed pump unit M2 MIX3 DN25;- High power under floor heating line, Δt 8 K: mixed pump unit M2 MIX33 DN32;- Medium power under floor heating line, Δt 15 K: mixed pump unit M2 MIX33 DN32.
M2DN 32
70 kWΔt 20 K
3.020 L/h
M2 M
IX33
DN 32
M2 M
IX33
DN 32
M2 M
IX3
DN 25
M2 DN 25
10 kWΔt 20 K430 L/h
30 kWΔt 20 K
1.290 L/h
30 kWΔt 8 K
3.230 L/h
20 kWΔt 15 K
1.720 L/h
HV80/125-4 DN 32
HW
80/12
5 DN
32
SG 200
629S
ET H
W80
HP
M2DN 25
10 kWΔt 20 K430 L/h
Wall fixing setDAOA32SET
Wall fixing setDAOA25SET
- 7 - http://www.brv.it email: [email protected]
Installation examples
Attention: the representations are to be considered just as an indication and they have no completeness pretension.
Heat source: solar and geothermic energy.Version 1: forced circulation solar thermal installation with the employment of a solar pump unit S1 Solar 10 to load a HDW tank.Version 2: natural circulation solar installation with the employment of solar collectors with HDW tank included.Distribution:Solar Kit 1, solar-boiler connection kit, to mix users’ HDW and anti scald-device Art. 790.Temperature increase: heat pump with HDW tank, fed by a geothermic system: GEO2 pump unit.
S1 So
lar 10
Modv
Sol e
xpan
sion v
esse
l
Version 1 Version 2GE
O2
Solar Kit 1
HP
790
- 8 - http://www.brv.it email: [email protected]
Installation examples
Attention: the representations are to be considered just as an indication and they have no completeness pretension.
Modv
Sol
expa
nsion
ve
ssel
S2 So
lar 2
High F
low
Modv
Fresh
3
VFS10-200
Modv
Maste
r VL
R24A
-LP/DW
CE
Modv
Slave
LR
Q24A-M
LP/E
Modv
Slave
Modv
Slave
Modv
Slave
Heat source: gas boiler.Buffer tank loading by boiler: unmixed pump unit M2 DN32; Δt 20 K.Buffer tank loading by solar thermal system: employment of a solar thermal pump unit S2 Solar 20 High Flow.HDW users:ModvFresh 3 HDW pump units, connected in a row with Kascata system;-1 pump unit without recycling with ModvMaster servomotor;-3 pump units without recycling with ModvSlave servomotor;-1 pump unit with recycling with ModvSlave servomotor.
80 kWΔt 20 K
3.450 L/h
M2 D
N 32
Wall fixing setDAOA32SET