MINI AC LEAKAGE CURRENT TESTER · 2016-04-28 · DT-9810 Mini AC Leakage Current Tester Electrical...

2
CEM www.cem-india.com / www.cem-instruments.in DT-9810 MINI AC LEAKAGE CURRENT TESTER I High resolution to 100μA AC I 3-1/2 digit (1999count) LCD display I White LED backlight Display I Auto power off I 1.2” Jaw opening I Single Hand Operation I Max. and Data Hold

Transcript of MINI AC LEAKAGE CURRENT TESTER · 2016-04-28 · DT-9810 Mini AC Leakage Current Tester Electrical...

Page 1: MINI AC LEAKAGE CURRENT TESTER · 2016-04-28 · DT-9810 Mini AC Leakage Current Tester Electrical Specifications General Specifications Contact : CEM INSTRUMENTS (INDIA) PVT. LTD.

CEM

www.cem-india.com / www.cem-instruments.in

DT-9810MINI AC LEAKAGE CURRENT TESTER

I High resolution to 100μA AC

I 3-1/2 digit (1999count) LCD display

I White LED backlight Display

I Auto power off

I 1.2” Jaw opening

I Single Hand Operation

I Max. and Data Hold

Page 2: MINI AC LEAKAGE CURRENT TESTER · 2016-04-28 · DT-9810 Mini AC Leakage Current Tester Electrical Specifications General Specifications Contact : CEM INSTRUMENTS (INDIA) PVT. LTD.

DT-9810 Mini AC Leakage Current Tester

Electrical Specifications

General Specifications

Contact :

CEM INSTRUMENTS (INDIA) PVT. LTD.32A, Ganesh Chandra Avenue, 4th Floor, Kolkata-700013Tel: 033-22151376, 22159759Email: [email protected] / [email protected]: www.cem-instruments.in / www.cem-india.com

CEM INSTRUMENTS HEADQUATER & FACTORY19th Building, 5th Region, Baiwangxin Industry Park, Songbai Road, Baimang, Xili, Nanshan, Shenzhen, China, 518108 Tel: +86-755-27353188, Fax: +86-755-27653699

Function Range Resolution Accuracy AC Current (60Hz)

200mA 100μA ±(5.0% of reading + 8digits)

2A 1mA ±(5.0% of reading + 10digits)

200A 100mA ±(2.5% of reading + 10digits)

Display 3-1/2 (1999 count) Digit LCD with white LED backlight

Overload indication “OL” displayed on the LCD

Display rate 2 readings/second, nominal

Battery Two “1.5V” batteries

Low Battery indication “ “displayed on the LCD

Auto OFF approx. 15 minutes

Max. Record Maximum Values

Data Hold Freezes Displayed Data.

Operating conditions32ºF to 86ºF (0ºC to 30ºC) 90%RH; 86ºF to 104ºF (30ºC to 40ºC) 75%RH; 104ºF to 122ºF (40ºC to 50ºC) 45%RH

Storage conditions -14ºF to 140ºF (-25ºC to 60ºC); < 90% Relative Humidity

Altitude Operate at less than 3000 meters

Weight 225g (including batteries)

Dimensions 182 x 61 x 34mm (HXWXD)

Jaw opening 1.2”

Standards EN61010-1, EN61010-2-032 Category II 600V,

CEM

Battery, Instruction Manual, Carrying Case and Test Certificate.

Accessories