Milliohm Meter FEATURES Microprocessor-controlled. Four terminal measurement. ● Measures down to 100μΩ. ● 5 Ranges from 200.0mΩ to 2000Ω. ● Maximum resolution of 100μΩ. Three test currents with over-temperature protection. Protection against inadvertent connection to over voltage. Large LCD. Potential lead resistance and current lead resistance checks. "Full-featured” EnerSave TM inside. EnerSave TM Auto hold. EnerSave TM Auto off. Lightweight, robust & compact. Indicators show if reading may be invalid (R P , R C , and temperature). "O-Ring” sealed case. SPECIFICATIONS Measuring ranges 0-200.0mΩ in steps of 100μΩ 0-2000mΩ in steps of 1mΩ 0-20.00Ω in steps of 10mΩ 0-200.0Ω in steps of 100mΩ 0-2000Ω in steps of 1Ω Accuracy ±0.5% of reading ±2 digits over the operating temperature range, -15ºC to +55ºC, with the supplied test leads Test current 1mA=>2000Ω range 10mA=>200 / 20Ω ranges 100mA=>2000m / 200mΩ ranges Test current accuracy ±0.1% Protection fuses Mains = 0.5A, HBC, 5 × 20mm, DIN Current = 0.5A, HBC, 5 × 20mm, DIN Voltage = 0.5A, HBC, 5 × 20mm, DIN Maximum output voltage (C1~C2) 20V Dimensions 250(L) × 190(W) × 110(D)mm Weight 4136 mO : 1530g 4137 mO : 1500g Safety standard EN 61010-1 CAT IV 20V EN 61326-1 Accessories Instruction manual Test leads Shoulder belt 1.5V (AA) × 8 (4137 mO) 4136 mO 4137 mO Power Source : 110V AC or 230V AC Power Source : 12V DC 4 Terminal Test 4-terminal = LED off 3-terminal = Led ON 4/3 T CPCPDIGITAL MILLIOHM METER LOCK 20.00 2000m 200.0m OFF ON 2000 200.0 EnerSave™ TESTRRC RP NO TEST Test Current Range 1mA 10mA 10mA 100mA 100mA 200.0 20.00 2000 2000m 200.0m C1 P1 C2 P2 MAX. DC20V C1 P1 C2 P2 MAX. DC20V kA DC AC ms mV Hz kM HOLD kA DC AC ms mV Hz kM MAX MIN RX RB RA Compression Joint Simplified Measurement 4-terminal = LED off 3-terminal = Led ON 4/3 T CPCPDIGITAL MILLIOHM METER LOCK 20.00 2000m 200.0m OFF ON 2000 200.0 AUTO-HOLD MICROPROCESSORCONTROLLED EnerSave™ TESTRRC RP NO TEST Test Current Range 1mA 10mA 10mA 100mA 100mA 200.0 20.00 2000 2000m 200.0m C1 P1 C2 P2 MAX. DC20V C1 P1 C2 P2 MAX. DC20V kA DC AC ms mV Hz kM HOLD kA DC AC ms mV Hz kM MAX MIN RX AL-34B TEL-4136C B (optional) 5F., NO.105, Jhongcheng Rd., Tucheng Dist., New Taipei City 23674, Taiwan (R.O.C.) TEL: 886-2-22681528 FAX: 886-2-22681529 e-mail: [email protected] www.sew.com.tw MEASURE WITH PRECISION

Transcript of Milliohm Meter - SEW · Milliohm Meter FEATURES ... 4136 mO : 1530g 4137 mO : 1500g Safety standard...

Page 1: Milliohm Meter - SEW · Milliohm Meter FEATURES ... 4136 mO : 1530g 4137 mO : 1500g Safety standard EN 61010-1 CAT IV 20V EN 61326-1 Accessories Instruction manual Test leads Shoulder

Milliohm Meter

FEATURES ● Microprocessor-controlled. ● Four terminal measurement. ● Measures down to 100μΩ. ● 5 Ranges from 200.0mΩ to 2000Ω. ● Maximum resolution of 100μΩ. ● Three test currents with over-temperature protection. ● Protection against inadvertent connection to over voltage. ● Large LCD. ● Potential lead resistance and current lead resistancechecks. ● "Full-featured” EnerSaveTM inside. ● EnerSaveTM Auto hold. ● EnerSaveTM Auto off. ● Lightweight, robust & compact. ● Indicators show if reading may be invalid (RP, RC, and temperature). ● "O-Ring” sealed case.

SPECIFICATIONS

Measuring ranges

0-200.0mΩ in steps of 100μΩ0-2000mΩ in steps of 1mΩ0-20.00Ω in steps of 10mΩ0-200.0Ω in steps of 100mΩ0-2000Ω in steps of 1Ω

Accuracy

±0.5% of reading ±2 digits over theoperating temperature range, -15ºC to +55ºC, with the supplied test leads

Test current1mA=>2000Ω range10mA=>200 / 20Ω ranges100mA=>2000m / 200mΩ ranges

Test current accuracy ±0.1%

Protection fusesMains = 0.5A, HBC, 5 × 20mm, DINCurrent = 0.5A, HBC, 5 × 20mm, DINVoltage = 0.5A, HBC, 5 × 20mm, DIN

Maximum outputvoltage (C1~C2) 20V

Dimensions 250(L) × 190(W) × 110(D)mm

Weight 4136 mO : 1530g4137 mO : 1500g

Safety standard EN 61010-1 CAT IV 20VEN 61326-1

Accessories Instruction manual Test leads Shoulder belt 1.5V (AA) × 8 (4137 mO)

4136 mO 4137 mOPower Source : 110V AC or 230V AC Power Source : 12V DC

4 Terminal Test

4-terminal = LED off

3-terminal = Led ON 4/3 T

C1 P1

C1 P1

DIGITAL MILLIOHM METER

LOCK

• Short Test duration if TESTis depressed for less than2Sec.

• Long Test Duration if TESTis depressed for more than3Sec.

20.002000m

200.0mOFF

ON

2000200.0

AUTO-HOLDMICROPROCESSOR CONTROLLED

EnerSave™TEST RP

RC

RP

NOTEST

Test Current Range1mA10mA10mA100mA100mA

200.020.00

2000

2000m200.0m

C1 P1 C2P2

MAX. DC20V

C1 P1 C2P2

MAX. DC20V

HOLD

kADC

AC

ms

mVHz

kM

M AX M INHOLD

kADC

AC

ms

mVHz

kM

MAX M IN

RX

RBRA

CompressionJoint

Simplified Measurement

4-terminal = LED off

3-terminal = Led ON 4/3 T

C1 P1

C1 P1

DIGITAL MILLIOHM METER

LOCK

• Short Test duration if TESTis depressed for less than2Sec.

• Long Test Duration if TESTis depressed for more than3Sec.

20.002000m

200.0mOFF

ON

2000200.0

AUTO-HOLDMICROPROCESSOR CONTROLLED

EnerSave™TEST RP

RC

RP

NOTEST

Test Current Range1mA10mA10mA100mA100mA

200.020.00

2000

2000m200.0m

C1 P1 C2P2

MAX. DC20V

C1 P1 C2P2

MAX. DC20V

HOLD

kADC

AC

ms

mVHz

kM

M AX M INHOLD

kADC

AC

ms

mVHz

kM

MAX M IN

RX

AL-34B TEL-4136C B(optional)

5F., NO.105, Jhongcheng Rd., Tucheng Dist., New Taipei City 23674, Taiwan (R.O.C.)

TEL: 886-2-22681528FAX: 886-2-22681529

e-mail: [email protected]

MEASURE WITH PRECISION