  • LVA series of 2-/4-Quadrant Amplifiers

    AUTOMOTIVE SUPPLY SIMULATION AT IT’S BEST

    LVA 1000 Front panel

     Extremely low harmonic distortion - even under very non-linear load conditions

     Very fast slew rate > 20V/μs

     Operates from DC up to 50kHz large signal bandwidth (-3dB)

     Small signal bandwidth up to 300kHz

     High short-term overload characteristic (for 30s)

     Very high peak-load ability (up to 200ms)

     Very low internal resistance

     Sink operation mode included – real 4-quadrant operation mode

     Touch panel operation 7” 800x480

    The relating standards: ISO 7637-2 ISO 16750-2 ISO 21848 LV 124 LV 148 SAE J 1113-11 Audi BT-LAH XXX.915.181.XX BMW GS 95002 BMW GS 95003-2 BMW GS 95024-2-2 BMW GS 95026 DaimlerChrysler DO-10615 Fiat 9.90110 Ford EMC-CS-2009.1 Ford FMC 1278 General Motors GMW 3097 Mercedes-Benz MBN 10615 Mercedes-Benz LV 124-1 Mercedes-Benz LV 148 MIL-STD-461F MIL-STD-704F MIL-STD-1275E Mitsubishi ES-X82010 Mitsubishi ES-X82114 Mitsubishi ES-X82115 Nissan 28400NDS02_3 PSA B21 7110 Renault 36-00-808/--M VW 80000 VW 80101 VW 82148 VW TL 82066 VW TL 82366

    THE REFERENCE SOURCE FOR AUTOMOTIVE APPLICATIONS PERFECT FOR MANY AVIONIC AND MILITARY STANDARDS

    Distributed by: Reliant EMC LLC, +408­320­9644/+408­916­5750, www.reliantemc.com

  • AMPLIFIER RANGES – FRONT PANEL MENUS AND OPTIONS

    The LVA 4-Quadrant Amplifier offers four standard voltage ranges: 20VDC 36VDC 54VDC 70VDC With the built in oscillator unit the amplifier’s input signal can be: DC signal Sine wave Rectangular wave Triangular wave Ramp (amplitude sweep) User defined Alternatively an external signal generator can be used. For each voltage range the operating mode options can be selected. With the option “OPD” (over- voltage protection device) the EUT’s supply voltage is monitored and the EUT is protected against very fast rising high voltage. The LVA allows optionally specifying the amplifier’s internal resistance from 0 to 200mΩ in each mode of operation. Optionally the sink mode capability can be disabled.

    LVA range selection menu

    LVA oscillator signal selection menu

    LVA range options menu

    Distributed by: Reliant EMC LLC, +408­320­9644/+408­916­5750, www.reliantemc.com

  • AMPLIFIER CHARACTERISTIC – AMPLIFICATION AND PHASE RESPONSE

    Amplifier characteristic Large signal bandwidth 100Hz … 300kHz 20V Range, 12Vp output open loop

    Amplification

    Frequency

    Phase characteristic

    Frequency

    Amplifier characteristic Small signal bandwidth 100Hz … 300kHz 20V Range, 2Vp output open loop

    Amplification

    Frequency

    Phase characteristic

    Frequency

    Distributed by: Reliant EMC LLC, +408­320­9644/+408­916­5750, www.reliantemc.com

  • Amplifier characteristic Small signal bandwidth 100Hz … 300kHz 20V Range, 2Vp output Load 2

    Amplification

    Frequency

    Phase characteristic

    Frequency

    Amplifier characteristic Small signal bandwidth 100Hz … 300kHz 20V Range, 2Vp output Load 1

    Amplification

    Frequency

    Phase characteristic

    Frequency

    Distributed by: Reliant EMC LLC, +408­320­9644/+408­916­5750, www.reliantemc.com

  • Amplifier characteristic Large signal bandwidth 100Hz … 300kHz 70V Range, 70Vp output open loop

    Amplification

    Frequency

    Phase characteristic

    Frequency

    Amplifier characteristic Small signal bandwidth 100Hz … 300kHz 70V Range, 7Vp output open loop

    Amplification

    Frequency

    Phase characteristic

    Frequency

    Distributed by: Reliant EMC LLC, +408­320­9644/+408­916­5750, www.reliantemc.com

  • Amplifier characteristic Large signal bandwidth 100Hz … 300kHz 70V Range, 70Vp output Load 10

    Amplification

    Frequency

    Phase characteristic

    Frequency

    Amplifier characteristic Small signal bandwidth 100Hz … 300kHz 70V Range, 2Vp output Load 1

    Amplification

    Frequency

    Phase characteristic

    Frequency

    Distributed by: Reliant EMC LLC, +408­320­9644/+408­916­5750, www.reliantemc.com

  • AMPLIFIER CHARACTERISTIC – 4-QUADRANT OPERATION

    The LVA amplifier is a real 4-Quadrant Amplifier. Due to this advanced technology four different application scenarios are possible:

    -U/+I

    +U/+I

    II. Quadrant negative voltage, positive current LVA 2500 example values: Utest Isink cont Isink short -12V 33ADC 66ADC

    Typical application: The LVA simulates a voltage drop of the negative testing voltage and the EUT’s input has a capacitive stage feeding energy back into the LVA

    I. Quadrant positive voltage, positive current LVA 2500 example values: Utest Icont Ishort 12V 115ADC 200ADC 24V 85ADC 170ADC 48V 60ADC 120ADC

    Typical application: The LVA supplies positive testing voltage to the EUT

    III. Quadrant negative voltage, negative current LVA 2500 example values: Utest Icont Ishort -12V -33ADC -66ADC

    Typical application: The LVA supplies negative testing voltage to the EUT

    IV. Quadrant positive voltage, negative current LVA 2500 example values: Utest Isink cont Isink short 12V -57ADC -114ADC 24V -43ADC -86ADC 48V -30ADC -60ADC

    Typical application: The LVA simulates a voltage drop and the EUT’s input has a capacitive stage feeding energy back into the LVA

    -U/-I +U/-I

    Distributed by: Reliant EMC LLC, +408­320­9644/+408­916­5750, www.reliantemc.com

  • AMPLIFIER CHARACTERISTIC – OUTPUT CURRENT CAPABILITY (as a percentage of the nominal constant current, at nominal supply voltage 230V and 23°C environment temperature)

    20V Range: Short-time current (30s) Continuous current I: 4% / DIV U: 1V / DIV

    36V Range Short-time current (30s) Continuous current I: 5.9% / DIV U: 2V / DIV

    Distributed by: Reliant EMC LLC, +408­320­9644/+408­916­5750, www.reliantemc.com

  • 54V Range Short-time current (30s) Continuous current I: 16.6% / DIV U: 5V / DIV

    70V Range Short-time current (30s) Continuous current I: 10% / DIV U: 5V / DIV

    Distributed by: Reliant EMC LLC, +408­320­9644/+408­916­5750, www.reliantemc.com

  • AMPLIFIER CHARACTERISTIC – SINK MODE CAPABILITY (as a percentage of the max. sink current, at nominal supply voltage 230V and 23°C environment temperature)

    20V Range Short-time sink current (30s) Continuous sink current I: 6.25% / DIV U: 1V / DIV

    36V Range Short-time sink current (30s) Continuous sink current I: 6.25% / DIV U: 2V / DIV

    Distributed by: Reliant EMC LLC, +408­320­9644/+408­916­5750, www.reliantemc.com

  • 11/14 © Spitzenberger & Spies 2015 – all data are subject to change

    SPS-TD-LVA-e-0004.docx

    54V Range Short-time sink current (30s) Continuous sink current I: 16.6% / DIV U: 5V / DIV

    70V Range Short-time sink current (30s) Continuous sink current I: 10% / DIV U: 5V / DIV

    Distributed by: Reliant EMC LLC, +408­320­9644/+408­916­5750, www.reliantemc.com

  • 12/14 © Spitzenberger & Spies 2015 – all data are subject to change

    SPS-TD-LVA-e-0004.docx

    TECHNICAL DATA – TYPE SPECIFIC

    LVA 1000 LVA 2500 Continuous power (at 12/24/48V): 280W / 480W / 1400W 1380W / 2040W / 2400W

    Short-time power: (at 12/24/48V for max 30s, duty cycle 1:9)

    490W / 840W / 2450W 2400W / 4080W / 4800W

    Peak power: (at 12/24/48V for max 200ms)

    700W / 1200W / 3500W 3600W / 7200W / 14400W

    Max. peak current capability: (at 12/24/48V for up to 200ms)

    35A 300A

    Continuous sink current capability: (20V / 36V / 54V / 70V Range)

    On request 80A / 80A / 60A / 50A

    Nominal Voltages: Output current capability

    U1: 0VDC … 20VDC Icont:25ADC Ishort-time: 35ADC Icont: 125ADC Ishort-time: 200ADC

    U2: 0VDC … 36VDC Icont:20ADC Ishort-time: 35ADC Icont: 85ADC Ishort-time: 170ADC

    U3: 0VDC … 54VDC Icont:20ADC Ishort-time: 35ADC Icont: 60ADC Ishort-time: 120ADC

    U4: 0VDC … 70VDC Icont:20ADC Ishort-time: 35ADC Icont: 50ADC Ishort-time: 100ADC

    U1 … U4: -15VDC … 0VDC Icont:10ADC Ishort-time: 15ADC Icont: 33ADC Ishort-time: 66ADC

    Digital instrument:

    Voltage range: Autoranging (20/40/80V Ranges)

    Current range: 100A 300A

    Accuracy(1): Voltage (DC): 0.1% Current (DC): 0.5%

    Supply: Power Supply: 230V (±10%, 50Hz … 60Hz) 230V/400V (±10%, 50Hz … 60Hz)

    Protection: 6A 16A

    Connector type: Schuko CEE

    Housing: 19”-plug-in unit, colour light grey (RAL 7035)

    Dimensions (mm): Amplifier incl. Power supply (5U) 222x483x700

    Amplifier (5U): 222x483x700, Power supply (6U): 267x483x700

    Weight: approx. 60kg LVA: approx. 30kg, NT: approx. 90kg

    General:

    Voltage adjustment: depending on oscillator used

    Load regulation: 0 … nominal load max. 0.2