Lightning Rods, Accessories H M D SideView Mod.PDC6.3 TopView Mod.PDC6.3 Protection Areas According to NFC17-102: 2011, the standard protection radius (RP) of SI ESE is linked to ΔT (below), the protection levels I, II, III or IV (as calculated in Annex B of NFC17-102: 2011) and the height of the SI ESE above the structure to be protected (H, defined by NFC17-102: 2011 as a minimum 2 m). Weight t LEVEL I LEVEL II LEVEL III LEVEL IV 2.35kg 15 μs 35 m 43 m 54 m 63 m 45 m 54 m 65 m 75 m 54 m 63 m 74 m 85 m 63 m 72 m 84 m 95 m 74 m 83 m 95 m 106 m 3.20 kg 3.40kg 3.60kg 3.80kg 25 μs 34 μs 43 μs 54 μs Protection radii calculated according to: Norm UNE 21.186 & NFC 17.102. (These radii of protection have been calculated according to an altitude difference of 20 m. between the end of the lightning rods and the considered horizontal plane). Type PDC3.1 PDC 3.3 PDC 4.3 PDC 5.3 PDC 6.3 R P H Features • Manufactured in AISI 304L stainless steel . Does not need an external power supply. Guarantee of electrical continuity and operation after lightning strike, in any atmospheric conditions. • Lightning rod with non-electronic ESE (Early Streamer Emis- sion) system,standardized according norms UNE 21.186 and NFC 17.102. Adaptable to all types of buildings. Application standards: UNE 21.186 NFC 17.102 EN 50.164/1 EN 62.305 Catalogue valid as of January 1, 2018 www.LSP-international.com 1 A

Transcript of Lightning Rods, Accessories...Lightning Rods Lightning Rods, Accessories 6 Catalogue valid as of...

Page 1: Lightning Rods, Accessories...Lightning Rods Lightning Rods, Accessories 6 Catalogue valid as of January 1, 2018 Coverage radius (m) LSP PDC 3.1 according to protection level and height

Lightning Rods, Accessories

H

M

D

Side�ViewMod.�PDC�6.3

Top�ViewMod.�PDC�6.3

Protection AreasAccording to NFC17-102: 2011, the standard protection radius (RP) of SI ESE is linked to ΔT (below), the protection levels I, II, III or IV (as calculated in Annex B of NFC17-102: 2011) and the height of the SI ESE above the structure to be protected (H, defined by NFC17-102: 2011 as a minimum 2 m).

Weight△t

LEVEL ILEVEL IILEVEL IIILEVEL IV

2.35�kg

15 μs35 m43 m54 m63 m

45 m54 m65 m75 m

54 m63 m74 m85 m

63 m72 m84 m95 m

74 m83 m95 m

106 m

3.20 kg 3.40�kg 3.60�kg 3.80�kg

25 μs 34 μs 43 μs 54 μs

Protection radii calculated according to: Norm UNE 21.186 & NFC 17.102. (These radii of protection have been calculated according to an altitude difference of 20 m. between the end of the lightning rods and the considered horizontal plane).

Type PDC�3.1 PDC 3.3 PDC 4.3 PDC 5.3 PDC 6.3

RP

H

Features

• Manufactured in AISI 304L stainless steel .Does not need an external power supply.Guarantee of electrical continuity and operation after lightning strike, in any atmospheric conditions.

• Lightning rod with non-electronic ESE (Early Streamer Emis-sion) system,standardized according norms UNE 21.186 and NFC 17.102.Adaptable to all types of buildings.Application standards: UNE 21.186 NFC 17.102 EN 50.164/1 EN 62.305

Catalogue valid as of January 1, 2018www.LSP-international.com1

A

Page 2: Lightning Rods, Accessories...Lightning Rods Lightning Rods, Accessories 6 Catalogue valid as of January 1, 2018 Coverage radius (m) LSP PDC 3.1 according to protection level and height

Where h≥5 m, then R can be calculated fromP

R (h) = √2rh-h2+Δ (2r+Δ) for h≥5mP

Where 2 m ≤ h ≤ 5 m, then RP can be calculated from R = h x R (5) / 5P P

R (h) (m) is the protection radius at a given height hP

h (m) is the height of the PDC series tip over the horizontal plane through the furthest point of the object to be protectedr (m) 20 m for protection level I 30 m for protection level II 45 m for protection level III 60 m for protection level IVΔ (m) Δ = ΔT x 106

MANUFACTURED BY

LIGHTNING AND SURGE PROTECTION LTD

LIGHTNING STRIKE COUNTER

Type: LSC0 0 0 0 0

OR

ER2-2000-SS ER3-2000-SS

ER1-2000-SS

Lightning Rods, Accessories

Working PrinciplesDuring thunderstorm conditions when the lightning down-leader is approaching ground level, an upward leader may be created by any conductive surface. In the case of a passive lightning rod, the upward leader propagates only after a long period of charge reorganization. In the case of PDC series, the initiation time of an upward leader is greatly reduced. The PDC seriesgenerates controlled magnitude and frequency pulses at the tip of the terminal during high static fields characteristic prior to a lightning discharge. This enables the creation of an upward leader from the terminal that propagates towards the downward leader coming from the thundercloud.

System RequirementsThe design and installation of the terminals should be completed in compliance with the requirements of the French Standard NF C 17-102. In addition to terminal placement requirements, the standard requires a minimum of two paths to ground per terminal

2for non-isolated conductor systems. A down conductor cross-sectional area of ≥50 mm is specified. The down conductors are to be secured at three points per meter with equipotential bonding made to nearby metallic items.

Each down conductor requires a test clamp and dedicated earth system of 10 ohms or less. The lightning protection ground should be connected to the main building ground and any nearby buried metallic items. The NF C 17-102 and similar ESE standards requirements for inspection and testing range from each year to every four years dependent upon location and protection level selected.

MANUFACTURED BY

LIGHTNING AND SURGE PROTECTION LTD

LIGHTNING STRIKE COUNTER

Type: LSC0 0 0 0 0

PDC series of ERmasts and supporthardware provide awide range of mountingoptions for bothcantilevered andguyed installations.

ER-BASE-SS ER-BASE-SS

Catalogue valid as of January 1, 2018www.LSP-international.com2

Page 3: Lightning Rods, Accessories...Lightning Rods Lightning Rods, Accessories 6 Catalogue valid as of January 1, 2018 Coverage radius (m) LSP PDC 3.1 according to protection level and height

MANUFACTURED BY

LIGHTNING AND SURGE PROTECTION LTD

LIGHTNING STRIKE COUNTER

Type: LSC0 0 0 0 0

MANUFACTURED BY

LIGHTNING AND SURGE PROTECTION LTD

LIGHTNING STRIKE COUNTER

Type: LSC0 0 0 0 0

Typical MAST Installation Arrangement

PDC series

1 m

1 m1 m

For masts 2-3 mabove roof plane,1 m lower cantileversection with 2mounting brackets

For masts 4-6 mabove roof plane,2 m lower cantileversection with 3mounting brackets

DOWNCONDUCTORRefer to your local standard for downconductornumber and routing requirements.

CABTIE-SS

ALOF-1-GS

TMC-SS

Type: LSC0 0 0

LIGHTNING STRIKE COUNTER

0 0

LSC

Lightning Rods, Accessories

For Cantilevered Mast

MANUFACTURED BY

LIGHTNING AND SURGE PROTECTION LTD

Catalogue valid as of January 1, 2018www.LSP-international.com3

PDC series

Page 4: Lightning Rods, Accessories...Lightning Rods Lightning Rods, Accessories 6 Catalogue valid as of January 1, 2018 Coverage radius (m) LSP PDC 3.1 according to protection level and height

Typical MAST Installation Arrangement

LIGHTNING STRIKE COUNTER

Type: LSC0 0 0 0 0

CABTIE-SS

Type: LSC0 0 0

LIGHTNING STRIKE COUNTER

0 0

TMC-SS

TMC-SS

Lightning Rods, Accessories

For Cantilevered Mast

MANUFACTURED BY

LIGHTNING AND SURGE PROTECTION LTD

MANUFACTURED BY

LIGHTNING AND SURGE PROTECTION LTD

PDC series

Catalogue valid as of January 1, 2018www.LSP-international.com4

Page 5: Lightning Rods, Accessories...Lightning Rods Lightning Rods, Accessories 6 Catalogue valid as of January 1, 2018 Coverage radius (m) LSP PDC 3.1 according to protection level and height

Typical bill-of-materials for masts

Standard Mounting Method (2-6 m)

Cantilevered Masts

Guyed Masts:

ER1-2000-SSER2-2000-SSER3-2000-SS ER-BASE-SS TMC-SSTMC-SS

WIREROPE7MHANGCLAMP-M8

TURNBUCLE-M6DUPLEXCLIP-M6ANCHOR-M8

CABTIE-SS

MaterialMast height

GUY KITS

Notes• For masts of 2 to 3 meters above the roof plane, 1 m lower cantilever section with 2 mounting brackets are required.• For masts of 4 to 6 meters above the roof plane, 2 m lower cantilever section with 3 mounting brackets are required.• The downconductor should connect at the bottom of the upper mast section.• CABTIE-SS are installed 3 per meter to strap the downconductor to the remaining length of lower mast.• Other items required per standards, Downconductor(s), fixing(s), protective sleeve(s), earth test clamp(s), Lightning Strike Counter and grounding system.

Notes• For masts of 2 to 3 meters above the roof plane, 1 m lower cantilever section with 2 mounting brackets are required.• For masts of 4 to 6 meters above the roof plane, 2 m lower cantilever section with 3 mounting brackets are required.• The downconductor should connect at the bottom of the upper mast section.• CABTIE-SS are installed 3 per meter to strap the downconductor to the remaining length of lower mast.• Other items required per standards, Downconductor(s), fixing(s), protec-tive sleeve(s), earth test clamp(s), Lightning Strike Counter and grounding system.

Height above roof plane

ER1-2000-SSER2-2000-SSER3-2000-SS

ALOF-1-GS

CABTIE-SSTMC-SS

3m 4m 4m 6m

2 3 16

19

••

•••

Lightning Rods, Accessories

SI Adaptor

SI Adaptor

6

••

11

4m

6

4 9

4

4

8

•••

4

11

6m

1

1

1

1

Total mast height

OR

ER1-2000-SS

ER2-2000-SS ER3-2000-SS

ER-BASE-SS ER-BASE-SS

Catalogue valid as of January 1, 2018www.LSP-international.com5

Page 6: Lightning Rods, Accessories...Lightning Rods Lightning Rods, Accessories 6 Catalogue valid as of January 1, 2018 Coverage radius (m) LSP PDC 3.1 according to protection level and height

Lightning Rods

Lightning Rods, Accessories

Catalogue valid as of January 1, 2018www.LSP-international.com6

Coverage radius (m) LSP PDC 3.1 according to protection level and height (UNE 21.186:2011, NFC 17.102:2011 and NP 4426:2013)

ModelPDC 3.1

MaterialSST

H (mm)387

D (mm)16

M (mm)M20

A (mm)95

Weight (g)2350

h (m)246

1020

LEVEL I1325323435

LEVEL II1530384043

LEVEL III1836464954

LEVEL IV2041525663

Δt : 15μsD: Streaming distanceL-I : D = 20 mL-II : D = 30 mL-III : D = 45 mL-IV : D = 60 m

H

M

A

LSP PDC 3.1LIGHTNING ROD

D

H

M

A

LSP PDC 3.3LIGHTNING RODCoverage radius (m) LSP PDC 3.3 according to protection level and height (UNE 21.186:2011, NFC 17.102:2011 and NP 4426:2013)

ModelPDC 3.3

MaterialSST

H (mm)598

D (mm)16

M (mm)M20

A (mm)156

Weight (g)3200

h (m) LEVEL I1734434445

LEVEL II2039495154

LEVEL III2346586165

LEVEL IV2652666975

Δt : 25μsD: Streaming distanceL-I : D = 20 mL-II : D = 30 mL-III : D = 45 mL-IV : D = 60 m

246

1020

D

H

M

A

D Coverage radius (m) LSP PDC 4.3 according to protection level and height (UNE 21.186:2011, NFC 17.102:2011 and NP 4426:2013)

LSP PDC 4.3LIGHTNING ROD

ModelPDC 4.3

MaterialSST

H (mm)598

D (mm)16

M (mm)M20

A (mm)156

Weight (g)3200

246

1020

2141525354

2447596163

2754697174

3061778085

Δt : 25μsD: Streaming distanceL-I : D = 20 mL-II : D = 30 mL-III : D = 45 mL-IV : D = 60 m

h (m) LEVEL I LEVEL II LEVEL III LEVEL IV

Page 7: Lightning Rods, Accessories...Lightning Rods Lightning Rods, Accessories 6 Catalogue valid as of January 1, 2018 Coverage radius (m) LSP PDC 3.1 according to protection level and height

D

Coverage radius (m) LSP PDC 6.3 according to protection level and height (UNE 21.186:2011, NFC 17.102:2011 and NP 4426:2013)

ModelPDC 5.3

MaterialSST

H (mm)598

D (mm)16

M (mm)M20

A (mm)156

Weight (g)3600

h (m)246

1020

LEVEL I2449616263

LEVEL II2755697072

LEVEL III3163798184

LEVEL IV3570889095

Δt : 15μsD: Streaming distanceL-I : D = 20 mL-II : D = 30 mL-III : D = 45 mL-IV : D = 60 m

Lightning Rods

Lightning Rods, Accessories

LSP PDC 5.3LIGHTNING ROD

D

Coverage radius (m) LSP PDC 6.3 according to protection level and height (UNE 21.186:2011, NFC 17.102:2011 and NP 4426:2013)

ModelPDC 6.3

MaterialSST

H (mm)598

D (mm)16

M (mm)M20

A (mm)156

Weight (g)3800

h (m)246

1020

LEVEL I2958737374

LEVEL II3264808283

LEVEL III3672919395

LEVEL IV4080

100102106

Δt : 15μsD: Streaming distanceL-I : D = 20 mL-II : D = 30 mL-III : D = 45 mL-IV : D = 60 m

LSP PDC 6.3LIGHTNING ROD

Catalogue valid as of January 1, 2018www.LSP-international.com7

H

A

M

M

Lightning rod adaptor pieces

MaterialDescription

Height H1 (mm)Stainless steelFor PDC 3.1 PDC 3.3 PDC 4.3

68

Type

Diameter�ØD1 (mm)Diameter�ØD2 (mm)M (mm)

49 (1’1/2”)27M20

Height H2 (mm) 47

Stainless steel68

54 (1’1/2”)26M20

Weight (kg) 0.70 0.80

47

ØD1

Μ

ØD2

H1H2

Adaptor I Adaptor II

AdaptorUsed for connecting lightning rod with mast

For PDC 5.3 PDC 6.3

H

A

Page 8: Lightning Rods, Accessories...Lightning Rods Lightning Rods, Accessories 6 Catalogue valid as of January 1, 2018 Coverage radius (m) LSP PDC 3.1 according to protection level and height

Lightning rod adaptor pieces

Lightning Rods, Accessories

Catalogue valid as of January 1, 2018www.LSP-international.com8

Type Adaptor IV

AdaptorUsed for connecting lightning rod with mast

H1

W1

M2

H3

H2

W2

M1

ØDM3

MaterialHeight H1 (mm)

Type Adaptor V

Height H2 (mm)

Diameter�ØD (mm)M1 (mm)

Weight (kg)

M3 (mm)

Height H3 (mm)

M2 (mm)

Width W1 (mm)Width W2 (mm)

AdaptorUsed for connecting lightning rod with mast

H1H2

M2

ØD1

Μ1

ØD2

MaterialType

Diameter ØD (mm)M1 (mm)M2 (mm)

M4 (mm)M3 (mm)

Height H (mm)

ER1-2000-SS

Description Upper section, 2m

200038

ER2-2000-SS ER3-2000-SS

Material Stainless SteelMid section, 2mStainless Steel

Lower section, 2mStainless Steel

200038

200038

M27 × 35M38 × 40

M38 × 40M38 × 40

M38 × 40M38 × 40

_

Weight (kg)

_

__

__

2000

ØD

M1

M2

ØD

M3

M4

ER1-2000-SS

2000

ER2-2000-SSER3-2000-SS

Stainless Steel Stainless Steel Stainless Steel

Stainless Steel MastUsed for Support Lightning Rods

8 8.5 8.5

MaterialDescription

Stainless steelFor PDC 3.1 PDC 3.3 PDC 4.3 PDC 5.3 PDC 6.3

Type Adaptor III

Diameter ØD1 (mm)Diameter�ØD2 (mm)M1 (mm)

41 (1’1/2”)10M20

Weight (kg) 0.65M2 (mm) M11

Height H2 (mm) 45

AdaptorUsed for connecting lightning rod with mast

ØD2

Μ1

ØD1

M2H1

H2 Height H1 (mm) 71

MaterialHeight H1 (mm)

Cu/Zn80

Diameter�ØD1 (mm)Diameter�ØD2 (mm)M1 (mm)

41 (1’1/2”)12M20

Weight (kg) 0.75M2 (mm) M11

Height H2 (mm) 60

Description

Cu/Zn16158

21M20

0.50

M25

27

M10

331

Description

For PDC 3.1 PDC 3.3 PDC 4.3 PDC 5.3 PDC 6.3

For PDC 3.1 PDC 3.3 PDC 4.3 PDC 5.3 PDC 6.3

Page 9: Lightning Rods, Accessories...Lightning Rods Lightning Rods, Accessories 6 Catalogue valid as of January 1, 2018 Coverage radius (m) LSP PDC 3.1 according to protection level and height

Accessories

Lightning Rods, Accessories

MaterialLength L1 (mm)

Hot-Dip Galvanized Steel495

Type ALOF-1-GS

Diameter ØD (mm)Hole Size HS (mm)M (mm)

28-55 11M10

A (mm)Weight (kg)

1353.70

Width W (mm) 165

165Length L2 (mm)

Wall Mounting BracketUsed for cantilevered mounting of masts 28 to 55 mm diameter

L1

ØD

M

W

L2A

ΗS

H

ØD1

T2

ØD2

T1

HS

Material Stainless SteelType ER-BASE-SS

Diameter ØD1 (mm)Diameter ØD2 (mm)

200

Hole Size HS (mm) 18.5

53

Thickness T2 (mm)

Weight (kg)

7.5

2.9

Thickness T1 (mm) 10

50Height H (mm)

Stainless Steel BaseplateHorizontal Surfaces Baseplate Support for Mast

Tie Mast ClampUse for clamp stranded conductor to ER mast

Type

Length L1 (mm)Length L2 (mm)Length L3 (mm)Length L4 (mm)Length L5 (mm)

Thickness T (mm)

6445223216

360.14

TMC-SS

Hole Size HS (mm)Weight (kg)

Width W1 (mm) 52Width W2 (mm) 36

Material Stainless Steel

T

L5

L3

L4�������� L1��������L2

W2W1

HS

Catalogue valid as of January 1, 2018www.LSP-international.com9

Page 10: Lightning Rods, Accessories...Lightning Rods Lightning Rods, Accessories 6 Catalogue valid as of January 1, 2018 Coverage radius (m) LSP PDC 3.1 according to protection level and height

Accessories

Cable TieUse for strapping down conductor to lower mast sections

MaterialDiameter ØD (mm)

Stainless Steel38-51

Type CABTIE-SS

0.7 0.02Weight (kg)

Width W (mm) 12Thickness T (mm)

Lightning Rods, Accessories

W

T

ØD

Catalogue valid as of January 1, 2018www.LSP-international.com10

Page 11: Lightning Rods, Accessories...Lightning Rods Lightning Rods, Accessories 6 Catalogue valid as of January 1, 2018 Coverage radius (m) LSP PDC 3.1 according to protection level and height

Guy Kits

Lightning Rods, Accessories

MaterialDiameter ØD (mm)

Type

Wire RopeStainless steel wire rope for 7m vertical guy heights

Weight (kg)Length L (mm)

Stainless steel5

1.007000

WIREROPE-D5ØD

Wire Rope Duplex ClipUsed for tie the wire rope

6TypeRope Ø (mm) Length (mm) L1

Width W1 (mm)

Width W3 (mm)

Bolt

60

Width W2 (mm) 2517

Thickness T (mm) 29.5

Length L2 (mm) 30

M6 × 220.06

DUPLEXCLIP-M6

Weight (kg)

L1

L2

W3

T

W1W2

Hang ClampUsed for fixing the wire rope on the ER mast.

Type

Rope Ø (mm) Length L1 (mm) Length L2 (mm) Length L3 (mm)

A (mm) M (mm)

Material646

Width W (mm) 26

2460

Diameter ØD (mm) 845°M8

HANGCLAMP-M8Stainless Steel

2 pcs Hang Clamp, 1 pcs Bolt0.07

SetWeight (kg)

24

ØD

W

A

L2L1

M8

46

L3

Catalogue valid as of January 1, 2018www.LSP-international.com11

Page 12: Lightning Rods, Accessories...Lightning Rods Lightning Rods, Accessories 6 Catalogue valid as of January 1, 2018 Coverage radius (m) LSP PDC 3.1 according to protection level and height

Guy Kits

Lightning Rods, Accessories

Eye Bolt Sleeve AnchorUsed for fixing the wire rope on the ground

6

Type

Rope Ø (mm) Length (mm) L1Length L2 (mm) Length L3 (mm) Diameter D1 (mm) ØDiameter D2 (mm) ØDiameter D3 (mm) ØT (mm)

356074352011.57.50.08

HANGCLAMP-M8

Weight (kg)

Stainless SteelMaterial

L3

L2

ØD

1

ØD

2

L1

T

ØD3

Weight (kg)

TurnbuckleUsed for tensing the wire rope

Stainless steel, hot-dipped galvanizedTypeMaterial

Length (mm) L1 Length L2 (mm) Length L3 (mm) A (mm) Shape

142924612Hook and Eye0.07

TURNBUCLE-M6

Weight (kg)

10Diameter ØD (mm)

L1

L2

L3

ØD

A

Catalogue valid as of January 1, 2018www.LSP-international.com12

Page 13: Lightning Rods, Accessories...Lightning Rods Lightning Rods, Accessories 6 Catalogue valid as of January 1, 2018 Coverage radius (m) LSP PDC 3.1 according to protection level and height

Operation current kA (8/20μs) > 2Five digits showing

Type LSC

Water proofingBody MaterialLength L1 (mm)

Stainless Steel, bakelite150135

40Stainless Steel

72

IP 50Display window

Length L2 (mm)

Hoop MaterialDiameter Ø (mm)

Height H (mm)

M (mm)Thickness T (mm)Weight (kg)

Width W (mm)

0.85

Ø 38 or Ø 90 51.9

Mechanical Lightning Strike CounterThe lightning strike counter is designed to keep a record of all direct lightning strikes on the external lightning protection system. The digital display (5 digits) allows a direct and comfortable reading of the number of recorded impacts. Fixed directly on the mast using 1 mounting hoop located on the side face to record number of lightning strikes.

Lightning Strike Counter

Lightning Rods, Accessories

Catalogue valid as of January 1, 2018www.LSP-international.com

0.80

InstallationThe lightning strike counter is fixed directly on the mast using 1 mounting flanges located on the back face. No interruption of the down conductor is necessary, thus allowing an excellent electrical continuity of the installation down from the rod to earthing the system. The counter records the lightning current by induction at the time of passage in the down conductor.

W

H

L1L2Ø

D

0 0 0 0 0LIGHTNING STRIKE COUNTER

Type: LSC

T

M

MANUFACTURED BYLIGHTNING AND SURGE PROTECTION LTD

13