Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24...

28
Kaplan turbine

Transcript of Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24...

Page 1: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Kaplan turbine

Page 2: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade
Page 3: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Jebba, Nigeria

*Q = 376 m3/s*H = 27,6 m*P = 96 MW

D0 = 8,5 mDe = 7,1 mDi = 3,1 mB0 = 2,8 m

Page 4: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Machicura, CHILE

*Q = 144 m3/s*H = 36,7 m*P = 48 MW

D0 = 7,2 mDe = 4,2 mDi = 1,9 mB0 = 1,3 m

Page 5: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Outletdraft tube

Outletrunner

Inletrunner

Outletguide vane

Inletguide vane

Page 6: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Hyd

raul

ic e

ffic

ien c

y η h

Flow rate Q

Runner blade angleφ = constant

Hydraulic efficiency

Page 7: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade
Page 8: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Hill chart

Page 9: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

c1

v1

u1

c2 v2

u2

Hgcucu 2u21u1

h ⋅⋅−⋅

Page 10: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Pressure distribution and torque

LiftLift

DragDrag

Torque

Arm

LL

DD

c

Page 11: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

LChord4

α

FLift

FDragv

AVCF

AVCF

DD

LL

⋅⋅⋅⋅=

⋅⋅⋅⋅=

2

2

21

21

ρ

ρ

Page 12: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Blade profile data

L

D

CC

Angle of attack

Angle of attackAngle of attack

Average relative Average relative velocityvelocity

δv∞

Page 13: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Pressure distribution and torque

Pressure side

Suction side

Cord length, l0,24 · l

Single profile

Cascade

The pressure at the outlet is lower for a cascade than for a single profile. The cavitation performance will therefore be reduced in a cascade.

Page 14: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Radial distribution of the blade profile

CL =Lift coefficient for a cascade

CL1 =Lift coefficient for a single profile

The ratio t/l influences the lift coefficient in a cascade. The cord length for a blade will therefore increase when the radius becomes increase

Page 15: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Radial distribution of the blade profile

Page 16: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Flow in the axial plane

The figure shows blades with two different design of the blade in radial direction. This is because it will influence the secondary flow in the radial direction

Page 17: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Main dimension of a Kaplan turbine

Page 18: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

no Q⋅ω=Ω

1.5

Cml =0.12 + 0.18 0

Cm

l

2.00

0

0.5

(tilnærmet)

1.0

2.5 3.0

( )

m1

n

m1

22

n

c4Q

D

c4

dDQ

⋅Π

⋅=

⋅−⋅Π

=

Diameter of the runner

Ω

Ω

Page 19: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Height of the guide vanesand runner diameter

0.4

0.3300 400

ns

B /D0

d/D

d/D

, B

/D0

500 700600 800 900

0.5

0.6

0.7

45n

s HPnn ⋅=

Page 20: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Gap between hub and ring and the runner blades

Gap between the blade and hub

Gap between the blade and ring

Spalteåpning x =1000s/D

Virk

ning

sgra

d

00.80

0.85

0.90

1

s = x 10 d-3

2 3 4 5 6

Effic

ienc

y

Gap

Page 21: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Runaway speed

ϕ2

ϕ3

ϕ1

ϕ6

02

2.2

2.4

2.6

0.5 1.0 2.0 3.0σ

ϕ5

ϕ4

kavitasjonskoeffisient

Rus

ning

stal

l/nor

mal

turta

ll

Voit h

Cavitation coefficient

Run

away

spee

d

HH10 S−

The figure shows different runaway speed at different runner blade openings. The runaway speed is dependent of the cavitation as shown in the figure

Page 22: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Hill chart

Page 23: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Example

P = 16,8 MWH = 16 mQn = 120 m3/sn = 125 rpm

• Find the dimensions D, d and Bo

• Given data:

Page 24: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

93,178,674,0Qn

o =⋅=⋅ω=Ω

sm7,171682,92Hg2 =⋅⋅=⋅⋅

srad1,13

602125

602n

=Π⋅⋅

=Π⋅⋅

1m74,0s

m7,17s

rad1,13

Hg2−==

⋅⋅ω

2

3

nm78,6

sm7,17

sm120

Hg2QQ ==⋅⋅

=

Speed number:

Page 25: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Diameter, D:

467,018,012,01 =Ω⋅+= omc

mc

QD

m

n 3,4467,0

478,64

1

=⋅Π

⋅=

⋅Π

⋅=

Page 26: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Diameter, d:

59016

22826125 4545 =⋅=⋅=

mHp

rpmHPnnn

s

0.4

0.3300 400

ns

B /D0

d/D

d/D

, B

/D0

500 700600 800 900

0.5

0.6

0.7

m9,145,0Dd45,0Dd

=⋅=⇒=

Page 27: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Height, B:

0.4

0.3300 400

ns

B /D0

d/D

d/D

, B

/D0

500 700600 800 900

0.5

0.6

0.7

m76,141,0DB41,0DB

OO =⋅=⇒=

Page 28: Kaplan turbine - · PDF filePressure distribution and torque Pressure side Suction side 0,24 · l Cord length, l Single profile Cascade The pressure at the outlet is lower for a cascade

Number of vanes, z:

95,0tl=

5z =

Num

ber o

f bla

des

z