  • Concept: Powerful recessed linear LED projector.Materials: Extruded 18 anodized aluminum body. Extra clear 10mm thick glass. Brushed stainless steel AISI316L border trim. Painted black die-cast aluminium end caps. Black polycarbonate driver housing.Optic: Internal optical unit composed of a primary cylindrical methacrylate lens, a high reflectance anodized aluminum reflector and an integrated holographic filter for Wall Wash, Grazing, and Flood effects. Spot version comes with individual lenses for more precise beam and higher intensity.Mounting: Anodized aluminum recessed mounting box. Driver: Integrated electronic drivers with available as non dimmable or 0-10V dimmable versions housed in Black polycarbonate driver box, two cables provided for 0-10V option.Installation: Cabled with SJ00W 18-3 cable and input/output watertight IP68 Quick Disconnect connectors. See page 2 for Inline connection configurations.Color Temperature: 2700K, 3000K, 3500K and 4000K availableCRI: 84

    Available Lengths: 24 / 36 / 48

    3.75

    3.62

    5

    3.00

    PRODUCT CODE TYPE DRIVER OPTICS LENGTH WATTAGE COLOR TEMP CABLE 2 LOUVER OPTION + INSTALLATION

    JE JEDI R Recessed 10 0-10V WW Wall Wash59 x 115

    24 24 HO High Output 271 2700K L Lead LV3 Integrated Louver Option

    Required

    ND Non-Dimming WG Wall Grazer15 x 76

    36 36 30 3000K C Center(See Pg 2)

    FL Flood32 x 85

    48 48 352 3500K E End

    SP Spot10 x 10

    40 4000K S Solo

    Lumen Maintenance (L70): 50,000hrsCalculation for LED fixtures are based on measurements that comply with with IES LM-80.Voltage: Universal Voltage 120-277V AC 50/60HzWeight: 17.2lbsIK: IK10IP: IP68**Load Rating: Resistant to static loads up to 20KN and vandalism up to IK10.Certifications: cULus listed Wet Location Listed E477426 H-20 Load rating tested, Tested in accordance with LM-79-08Warranty: 5 year limited warranty * Up to 1 METER DEPTH of water for up to a maximum of 30 MINUTES** Not suitable for submersible installations

    2 See Page 2 for inline cable configurations

    3 Integrated louver not available for spot optic

    1 2700K and 3500K not available with spot optic

    IP68IP67

    Wall Wash

    Wall Graze

    Spot

    Integrated Louver OptionIntegrated anti-glare louver option pre-installed inside the fixture. *Not available for Spot optics.

    Wall Wash Optic Shown

    Lumens: 24 (27W) 36 (38W) 48 (49W)3000K 4000K 3000K 4000K 3000K 4000K

    Wall Washer 59 x 115 = 2318Lm 2434Lm 3477Lm 3651Lm 4637Lm 4868LmWall Grazer 15 x 76 = 2565Lm 2694Lm 3849Lm 4041Lm 5133Lm 5389Lm

    Flood 32 x 85 2304Lm 2419Lm 3456Lm 3629Lm 4608Lm 4838LmSpot 10 x 10 = 1500Lm 1625Lm 2252Lm 2438Lm 3000Lm 3250Lm

    Refer to pages 4-7 for complete fixture data information.

    Targetti USA - A Targetti Group Company - 750-A W. 17th St. Costa Mesa, CA 92627 - Phone (714) 513-1991 - Email: [email protected] - www.Targetti.us - 12.19.17 - Page 1 of 7

    JEDI Powerful recessed linear LED projector

    Views

  • Cable Connection Options

    Fixture code: mL Lead Fixture

    Fixture code: mC Center Fixture

    Fixture code: mE End Fixture

    Fixture code: mS Solo Fixture

    10 ft power cord

    10 ft power cord

    2 Cables provided for 0-10V Dimmable versions

    * 2 cables provided for 0-10V dimmable versions

    INSTALLATION (REQUIRED)

    1E2749 24

    Ingrade Mounting box1E2750 36

    1E2751 48

    Targetti USA - A Targetti Group Company - 750-A W. 17th St. Costa Mesa, CA 92627 - Phone (714) 513-1991 - Email: [email protected] - www.Targetti.us - 12.19.17 - Page 2 of 7

    JEDI RECESSED

    CONNECTION CABLES

    JERNDLEAD-121 IP68 Additonal lead cable, direct burial fixture cable with IP68 female 3 socket connector.

    JER10LEAD-121 IP68 Additonal lead cable, direct burial fixture cable with IP68 female 3 socket connector and sparate 0-10V dimmable connection cord.

    JERNDJUMP-022 IP68 Connector cord, 2ft direct burial cable for fixture to fixture non-dimmable connection with IP68 male 3 socket connector and IP68 female 3-pin connector.

    JER10JUMP-022 IP68 Connector cord, 2ft direct burial cable for fixture to fixture connection with IP68 male 3 socket connector and IP68 female 3-pin connector and sparate 0-10V dimmable connection cord.

    1 Additional lead cables are sold in 2 foot increments, from 12 foot (JERxxLEAD12) to 80 foot (JERxxLEAD80). 2 Connector cords sold in 2 foot increments, from 2 foot (JERxxJUMP02) to 20 foot (JERxxJUMP20).

  • Optics

    Wall Wash 59x115

    Spot 10x10

    Wall Graze 15x76

    30in-45in ideal spacing*60in max (shown)

    *20in max (shown)

    60in(shown)

    24in-36in ideal set back*48in max set back (shown)

    20in max set back (shown)

    12in max set back (shown)

    h 13

    fth

    13ft

    h 20

    ft

    Spacing Ratio 1:1.25

    Spacing Ratio 1:1

    Wall Washer Optic for a uniform effect with installation. It makes it possible to obtain a completely homogeneous effect on the wall, avoiding any bright stripes or separate beams that are typical of

    linear fixtures fitted with visible LED strips.

    Grazing Optic for a grazing, uniform light effect for installation near the desired wall to be illuminated.

    Spot Optic for more concentrated, precise lighting.

    Targetti USA - A Targetti Group Company - 750-A W. 17th St. Costa Mesa, CA 92627 - Phone (714) 513-1991 - Email: [email protected] - www.Targetti.us - 12.19.17 - Page 3 of 7

    JEDI RECESSED

  • Wall Wash 59x115 Polar Graph Cone of Light

    Fixture Power 27W (24) 39W (36) 51W (48) (Ft) Max Med

    Fixture Output 2177Lm 3265Lm 4354Lm ftcd ftcd

    Kelvin Temp 2700K 2700K 2700K 35.00 2 1

    Beam Spread Wall Wash Wall Wash Wall Wash 28.00 2 1

    IMax 770cd/klm 770cd/klm 770cd/klm 21.00 4 2

    Efficacy 81 Lm/W 84 Lm/W 85 Lm/W 14.00 10 5

    7.00 39 20

    Photometrics

    Wall Wash 59x115 Polar Graph Cone of Light

    Fixture Power 27W (24) 39W (36) 51W (48) (Ft) Max Med

    Fixture Output 2318Lm 3477Lm 4637Lm ftcd ftcd

    Kelvin Temp 3000K 3000K 3000K 35.00 2 1

    Beam Spread Wall Wash Wall Wash Wall Wash 28.00 3 1

    IMax 770cd/klm 770cd/klm 770cd/klm 21.00 5 2

    Efficacy 86 Lm/W 89 Lm/W 91 Lm/W 14.00 11 5

    7.00 42 22

    Wall Wash 59x115 Polar Graph Cone of Light

    Fixture Power 27W (24) 39W (36) 51W (48) (Ft) Max Med

    Fixture Output 2393Lm 3590Lm 4786Lm ftcd ftcd

    Kelvin Temp 3500K 3500K 3500K 35.00 2 1

    Beam Spread Wall Wash Wall Wash Wall Wash 28.00 3 1

    IMax 770cd/klm 770cd/klm 770cd/klm 21.00 5 2

    Efficacy 89 Lm/W 92 Lm/W 94 Lm/W 14.00 11 6

    7.00 43 22

    Wall Wash 59x115 Polar Graph Cone of Light

    Fixture Power 27W (24) 39W (36) 51W (48) (Ft) Max Med

    Fixture Output 2434Lm 3651Lm 4868Lm ftcd ftcd

    Kelvin Temp 4000K 4000K 4000K 35.00 2 1

    Beam Spread Wall Wash Wall Wash Wall Wash 28.00 3 1

    IMax 770cd/klm 770cd/klm 770cd/klm 21.00 5 3

    Efficacy 90 Lm/W 89 Lm/W 96 Lm/W 14.00 11 6

    7.00 44 23

    Targetti USA - A Targetti Group Company - 750-A W. 17th St. Costa Mesa, CA 92627 - Phone (714) 513-1991 - Email: [email protected] - www.Targetti.us - 12.19.17 - Page 4 of 7

    JEDI RECESSED

  • Wall Grazer 15x76 Polar Graph Cone of Light

    Fixture Power 27W (24) 39W (36) 51W (48) (Ft) Max Med

    Fixture Output 2409Lm 3614Lm 4820Lm ftcd ftcd

    Kelvin Temp 2700K 2700K 2700K 35.00 4 2

    Beam Spread Wall Grazer Wall Grazer Wall Grazer 28.00 6 3

    IMax 1600cd/klm 1600cd/klm 1600cd/klm 21.00 11 5

    Efficacy 89 Lm/W 93 Lm/W 95 Lm/W 14.00 24 12

    7.00 95 48

    Wall Grazer 15x76 Polar Graph Cone of Light

    Fixture Power 27W (24) 39W (36) 51W (48) (Ft) Max Med

    Fixture Output 2565Lm 3849Lm 5133Lm ftcd ftcd

    Kelvin Temp 3000K 3000K 3000K 35.00 4 2

    Beam Spread Wall Grazer Wall Grazer Wall Grazer 28.00 6 3

    IMax 1601cd/klm 1601cd/klm 1601cd/klm 21.00 11 6

    Efficacy 95 Lm/W 94 Lm/W 101 Lm/W 14.00 25 12

    7.00 101 50

    Wall Grazer 15x76 Polar Graph Cone of Light

    Fixture Power 27W (24) 39W (36) 51W (48) (Ft) Max Med

    Fixture Output 2549Lm 3973Lm 5297Lm ftcd ftcd

    Kelvin Temp 3500K 3500K 3500K 35.00 4 2

    Beam Spread Wall Grazer Wall Grazer Wall Grazer 28.00 6 3

    IMax 1601cd/klm 1601cd/klm 1601cd/klm 21.00 12 6

    Efficacy 94 Lm/W 102 Lm/W 104 Lm/W 14.00 26 13

    7.00 104 52

    Wall Grazer 15x76 Polar Graph Cone of Light

    Fixture Power 27W (24) 39W (36) 51W (48) (Ft) Max Med

    Fixture Output 2694Lm 4041Lm 5389Lm ftcd ftcd

    Kelvin Temp 4000K 4000K 4000K 35.00 4 2

    Beam Spread Wall Grazer Wall Grazer Wall Grazer 28.00 7 3

    IMax 1601cd/klm 1601cd/klm 1601cd/klm 21.00 12 6

    Efficacy 95 Lm/W 104 Lm/W 106 Lm/W 14.00 26 13

    7.00 106 53

    Photometrics

    Targetti USA - A Targetti Group Company - 750-A W. 17th St. Costa Mesa, CA 92627 - Phone (714) 513-1991 - Email: [email protected] - www.Targetti.us - 12.19.17 - Page 5 of 7

    JEDI RECESSED

  • Flood 32x85 Polar Graph Cone of Light

    Fixture Power 27W (24) 38W (36) 49W (48) (Ft) Max Med

    Fixture Output 2163Lm 3245Lm 4327Lm ftcd ftcd

    Kelvin Temp 2700K 2700K 2700K 35.00 2 1

    Beam Spread FL 32x85 FL 32x85 FL 32x85 28.00 3 1

    IMax 699cd/klm 699cd/klm 699cd/klm 21.00 5 2

    Efficacy 80 Lm/W 85 Lm/W 88 Lm/W 14.00 10 5

    7.00 41 20

    Flood 32x85 Polar Graph Cone of Light

    Fixture Power 27W (24) 38W (36) 49W (48) (Ft) Max Med

    Fixture Output 2304Lm 3456Lm 4608Lm ftcd ftcd

    Kelvin Temp 3000K 3000K 3000K 35.00 2 1

    Beam Spread FL 32x85 FL 32x85 FL 32x85 28.00 3 1

    IMax 699cd/klm 699cd/klm 699cd/klm 21.00 5 2

    Efficacy 85 Lm/W 91 Lm/W 94 Lm/W 14.00 11 5