IdeFix IF - ΔΟΜΕΣdomesindex.com/media/companies/catalogs/IdeFix.pdf · 1 IdeFix® drilling...

8
56 IdeFix ® IF is a special fastener for joining cross-grained wood in an almost unlimited number of applications in timber construction. The small edge and axial distances permit even heavy-load connections in narrow space. Up to now high-load joints of cross-grained wood have been considered as highly problematic. IdeFix ® IF can transmit extremely high tensile and shearing forces even in cross-grained wood. Its special shape combined with 45 degree screwing permits three-dimensional load uptake in perpendicular and angular connections. In addition, each IdeFix ® IF is equipped with an integrated anti-twist protection for wood joints. Once mounted, the IdeFix ® IF can be tightened at any time. The invisibly bolted IdeFix ® IF guarantees optimal structural wood protection and an elegant appearance. IdeFix ® IF Three-dimensional, hidden end grain Anchor IdeFix ® IF has been technically approved by the German Institute of Building Technology for your and our safety. To maintain such high quality standards, SIHGA ® products are routinely subjected to tests and external supervision. www.sihga.com

Transcript of IdeFix IF - ΔΟΜΕΣdomesindex.com/media/companies/catalogs/IdeFix.pdf · 1 IdeFix® drilling...

Page 1: IdeFix IF - ΔΟΜΕΣdomesindex.com/media/companies/catalogs/IdeFix.pdf · 1 IdeFix® drilling template IBS including end stop, stabilizers and stop rod, SIHGA® fastening screws,

56

IdeFix® IF is a special fastener for joining cross-grained wood in an almost unlimited number of applications in timber construction. The small edge and axial distances permit

even heavy-load connections in narrow space.

Up to now high-load joints of cross-grained wood have been consideredas highly problematic.

IdeFix® IF can transmit extremely high tensile and shearing

forces even in cross-grained wood. Its special shape combined with 45 degree screwing permits three-dimensional

load uptake in perpendicular and angular connections.

In addition, each IdeFix® IF is equipped with an integrated anti-twist protection for wood joints. Once mounted,

the IdeFix® IF can be tightened at any time.

The invisibly bolted IdeFix® IF guarantees optimal structural wood protection and an elegant appearance.

IdeFix® IF

Three-dimensional, hidden end grain Anchor

IdeFix® IF has been technically approved by the German Institute of Building Technology for your and our safety. To maintain such high quality standards, SIHGA® products are routinely subjected to tests and external supervision.

ww

w.s

ihga

.com

Page 2: IdeFix IF - ΔΟΜΕΣdomesindex.com/media/companies/catalogs/IdeFix.pdf · 1 IdeFix® drilling template IBS including end stop, stabilizers and stop rod, SIHGA® fastening screws,

57

IdeF

ix®

Contents of the SIHGA® system kit IdeFix® SI:

1 montagepack IdeFix® IF,

1 IdeFix® drilling jig IBL,

1 IdeFix® drill IB,

1 IdeFix® drilling template IBS includingend stop, stabilizers and stop rod,

SIHGA® fastening screws,hexagon key and the SIHGA® Systemstift® pencil.

The IdeFix® SI is the perfect equipment for professional and time-efficient assembly, as shown on the following pages.

The professional tool kit

IdeFix® system kit SI

Page 3: IdeFix IF - ΔΟΜΕΣdomesindex.com/media/companies/catalogs/IdeFix.pdf · 1 IdeFix® drilling template IBS including end stop, stabilizers and stop rod, SIHGA® fastening screws,

58w

ww

.sih

ga.c

om

Simple and easy application without milling – all you need is a small drill hole by hand or by a joinery

machine.(Ø 30 mm, Ø 40 mm oder Ø 50 mm)

Put the IdeFix® IF into the drill hole and fasten it with the enclosed SIHGA® system screws.

The component to be fastened is joined with a standard screw or a threaded rod together with a

washer DIN ISO 7094 – FINISHED!

This joint can be tightened at any time. It can also be removed, if necessary.

IdeFix® IF assembly

OPTIONAL:Easy drilling by hand with the

IdeFix® drilling jig IBL and the IdeFix® drill IB* - fast, safe and accurate.

(Ø 30 mm, Ø 40 mm oder Ø 50 mm)

*included in the IdeFix® system kit SI.

OPTIONAL:Easy multiple drilling by hand with the

IdeFix® drilling jig IBL and the IdeFix® drill IB*fast, safe and accurate.

(Ø 30 mm, Ø 40 mm oder Ø 50 mm)

*included in the IdeFix® system kit SI.

Page 4: IdeFix IF - ΔΟΜΕΣdomesindex.com/media/companies/catalogs/IdeFix.pdf · 1 IdeFix® drilling template IBS including end stop, stabilizers and stop rod, SIHGA® fastening screws,

59

IdeF

ix®

Horizontal joints, vertical joints, oblique joints, one-row multiple joints, multiple-row multiple joints ...

IdeFix® IF applications

IdeFix® IF multiple joint for cross-grained wood, single or multiple-row

The small edge and axial distances permit the transmission of very high combined loads (tensile and lateral forces).

Fastening of the wooden parts can be tightened at any time.

This fastening system can also be used for oblique joints.

Detail: IdeFix® IF for cross-grained wood with tenon jointHere a small hole must be drilled into the wooden part to be joined (minimalized weakening of the wood despite tenon joint!).

Full effectiveness of the anti-twist protection permits on-site assembly similar to a tenon. In addition, tensile force may be statically combined with lateral force.

This fastening system can also be used for oblique joints.

Detail: IdeFix® IF joint for cross-grained woodWhen the standard screw / threaded rod is screwed in, the integrated anti-twist protection is automatically pressed into the wooden part to be joined.

This fastening system can also be used for oblique joints.

Page 5: IdeFix IF - ΔΟΜΕΣdomesindex.com/media/companies/catalogs/IdeFix.pdf · 1 IdeFix® drilling template IBS including end stop, stabilizers and stop rod, SIHGA® fastening screws,

60

Size Dimensions Joint Joint /tensile force *Joint/ lateral force System screw Anti-twist protection

IdeFix® IF dc Thread Drill hole [mm] Drill hole [mm] GoFix® FK vc

Type [mm] AG A B A B [mm] [mm]

304 30 M12 27 0 20 7 5,0 x 40 3

306 30 M12 27 0 20 7 5,0 x 60 3

308 30 M12 27 0 20 7 5,0 x 80 3

*For multiple joints, the drill hole B is increased by the anti-twist protection vc.

Before construction, all calculations must be checked and cleared by the responsible planner.Data valid except for typographical and printing errors.

406 40 M16 35 0 25 10 6,0 x 60 5

408 40 M16 35 0 25 10 6,0 x 80 5

410 40 M16 35 0 25 10 6,0 x 100 5

509 50 M20 45 0 30 15 8,0 x 90 5

ww

w.s

ihga

.com

drill hole A

grain direction

dc

AG

AG

vc

drill hole B

grain direction

Page 6: IdeFix IF - ΔΟΜΕΣdomesindex.com/media/companies/catalogs/IdeFix.pdf · 1 IdeFix® drilling template IBS including end stop, stabilizers and stop rod, SIHGA® fastening screws,

61

IdeF

ix®

SIHGA® Dimensions Secondary comp./ pillar Characteristic values

montagepack IdeFix® IF Height Width Tensile force F1 Lateral force F2

Art. No. PU Type [mm] [mm] [kN] [kN]

28806 24 304 100 100 16,23 8,70

28866 24 306 120 120 24,61 8,70

28816 24 308 140 140 32,67 8,70

28826 12 406 120 120 26,73 13,50

28886 12 408 160 160 35,58 13,50

28836 12 410 180 180 44,18 13,50

28846 6 509 160 160 45,08 18,84Characteristic values for dimensioning according to EC 5 resp. Din 1052:2008Characteristic values for strength class C 24 (rk 350 kg/m³)

7,68 4,45

11,65 4,45

15,47 4,45

12,65 6,91

16,84 6,91

20,91 6,91

21,34 10,43

*Permissible values

Tensile force F1

Lateral force F2

[kN] [kN]

Before construction, all calculations must be checked and cleared by the responsible planner.Data valid except for typographical and printing errors.

*ÖNORM B 4100(withdrawn)

F2

F1

F2

Secondary component/pillar

IF 30...Ø 30 mm

IF 40...Ø 40 mm

IF 50...Ø 50 mm

Page 7: IdeFix IF - ΔΟΜΕΣdomesindex.com/media/companies/catalogs/IdeFix.pdf · 1 IdeFix® drilling template IBS including end stop, stabilizers and stop rod, SIHGA® fastening screws,

62

SIHGA® IdeFix® Secondary comp. Number of Characteristic values

montagepack IF Width Height connectors Lateral force F2

Art. No. PU Type [mm] [mm] Units [kN]

28806 24 304 100 150 2 17,40

28826 12 406 120 180 2 27,00

28846 6 509 160 240 2 37,68

Characteristic values for dimensioning according to EC 5 resp. Din 1052:2008Characteristic values for strength class C 24 (rk 350 kg/m³)

8,90

13,82

20,86

*Permissible values

Lateral force F2

[kN]

28806 24 304 100 200 3 26,10

28826 12 406 120 240 3 40,50

28846 6 509 160 320 3 56,52

13,35

20,73

31,29

28806 24 304 100 250 4 34,80

28826 12 406 120 300 4 54,00

28846 6 509 160 400 4 75,36

17,80

27,64

41,72

28806 24 304 100 300 5 43,50

28826 12 406 120 360 5 67,50

28846 6 509 160 480 5 94,20

22,25

34,55

52,15

Edge and axial distance

IdeFix® IF

Type Rv Av

304 50 50

406 60 60

509 80 80

Before construction, all calculations must be checked and cleared by the responsible planner.Data valid except for typographical and printing errors.

F2

width

heig

ht

*ÖNORM B 4100(withdrawn)

ww

w.s

ihga

.com

Page 8: IdeFix IF - ΔΟΜΕΣdomesindex.com/media/companies/catalogs/IdeFix.pdf · 1 IdeFix® drilling template IBS including end stop, stabilizers and stop rod, SIHGA® fastening screws,

63

IdeF

ix®

SIHGA® IdeFix® Secondary comp. Number of Characteristic values

montagepack IF Width Height connectors Lateral force F2

Art. No. PU Type [mm] [mm] Units [kN]

28806 24 304 150 150 4 34,80

28826 12 406 180 180 4 54,00

28846 6 509 240 240 4 75,36

Characteristic values for dimensioning according to EC 5 resp. Din 1052:2008Characteristic values for strength class C 24 (rk 350 kg/m³)

17,80

27,64

41,72

*Permissible values

Lateral force F2

[kN]

28806 24 304 150 200 6 52,20

28826 12 406 180 240 6 81,00

28846 6 509 240 320 6 113,04

26,70

41,46

62,58

28806 24 304 150 250 8 69,60

28826 12 406 180 300 8 108,00

28846 6 509 240 400 8 150,72

35,60

55,28

83,44

28806 24 304 150 300 10 87,00

28826 12 406 180 360 10 135,00

28846 6 509 240 480 10 188,40

44,50

69,10

104,30

Edge and axial distance

IdeFix® IF

Type Rv Av

304 50 50

406 60 60

509 80 80

Before construction, all calculations must be checked and cleared by the responsible planner.Data valid except for typographical and printing errors.

F2

width

heig

ht

*ÖNORM B 4100(withdrawn)