FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

21
FONT Meeting 1 Charge normalisation and IP LO power scan N. Blaskovic N. Blaskovic

Transcript of FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

Page 1: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

FONT Meeting 1

Charge normalisationand IP LO power scan

N. Blaskovic

N. Blaskovic

Page 2: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

Contents

• Jitter dependence on charge normalisation(using P3 ΣI, IP reference diode or neither)

• IPC I & Q dependence on LO power level

FONT Meeting 2N. Blaskovic

Page 3: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

Charge normalisation

• Calibration and jitter runs taken on 060314• Waist on IPC in Y• Multiple RF variable attenuator settings• Upstream and downstream boards set-up• Results presented:

– Charge normalised using P3 ΣI

– Charge normalised using IP reference diode– Not charge normalised

FONT Meeting 3N. Blaskovic

Page 4: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

FONT Meeting 4N. Blaskovic

Page 5: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

Charge normalisation

• Charge normalisation appears to worsen jitter, particularly if reference diode is used

FONT Meeting 5N. Blaskovic

Page 6: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

LO power scan

• Jitter runs taken on 140314• Waist on IPC in Y• RF variable attenuator set to 10 dB• LO level for IPC(Y) electronics changed by

0-11 dB variable attenuator• I & Q signals in LO power scan presented

FONT Meeting 6N. Blaskovic

Page 7: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

FONT Meeting 7N. Blaskovic

IPA

IPB

IPC

Ref splitter

electronics

electronics

electronics

attenuator

RFvariable

attenuator

diode

FONT5 board

(digitiser)

port 1port 2

port 1port 2

port 1port 2

IQ

IQ

IQ

IP BPM C-band signalReference C-band signalBase-band signal

6.4 GHz (y) / 5.7 GHz (x)

hybrid

hybrid

LO var. atten.

LO variable attenuator

Page 8: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

FONT Meeting 8N. Blaskovic

IPC(Y) I

IPC(Y) Q

Ref(Y)

Page 9: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

FONT Meeting 9N. Blaskovic

IPC(Y) I

IPC(Y) Q

Ref(Y)

Page 10: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

FONT Meeting 10N. Blaskovic

IPC(Y) I

IPC(Y) Q

Ref(Y)

Page 11: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

FONT Meeting 11N. Blaskovic

IPC(Y) I

IPC(Y) Q

Ref(Y)

Page 12: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

FONT Meeting 12N. Blaskovic

IPC(Y) I

IPC(Y) Q

Ref(Y)

Page 13: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

FONT Meeting 13N. Blaskovic

IPC(Y) I

IPC(Y) Q

Ref(Y)

Page 14: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

FONT Meeting 14N. Blaskovic

IPC(Y) I

IPC(Y) Q

Ref(Y)

Page 15: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

FONT Meeting 15N. Blaskovic

IPC(Y) I

IPC(Y) Q

Ref(Y)

Page 16: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

FONT Meeting 16N. Blaskovic

IPC(Y) I

IPC(Y) Q

Ref(Y)

Page 17: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

FONT Meeting 17N. Blaskovic

IPC(Y) I

IPC(Y) Q

Ref(Y)

Page 18: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

FONT Meeting 18N. Blaskovic

IPC(Y) I

IPC(Y) Q

Ref(Y)

Page 19: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

FONT Meeting 19N. Blaskovic

IPC(Y) I

IPC(Y) Q

Ref(Y)

Page 20: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

LO power scan

• Mixer output should be in region where it does not vary with input LO level; Siwon:

FONT Meeting 20N. Blaskovic

Linear IF output rangedue to LO input

Page 21: FONT Meeting1 Charge normalisation and IP LO power scan N. Blaskovic.

Next steps

• Priority:– Propagate P2 & P3 position to IP waist (MAD)– 0-11 dB variable attenuator path length test– AQF7FF position to IP y’ pitch relation (FS)

• Interesting, but perhaps secondary:– Phase advance along beamline (MAD)– along beamline including MQF1-5X

• Digitiser at IP if 2 boards not available for upstream feedback with monitoring at IP?

FONT Meeting 21N. Blaskovic