Ensayo de Bombeo y Trazadores El Prat Nov-2000fcihs.espintime.com/tema6/docs/6.10.pdf · Ensayo de...
-
Upload
truongkhuong -
Category
Documents
-
view
230 -
download
6
Transcript of Ensayo de Bombeo y Trazadores El Prat Nov-2000fcihs.espintime.com/tema6/docs/6.10.pdf · Ensayo de...
Ensayo de Bombeo y Trazadores El Prat Nov-2000
PH-28
PH-27
SM-09
PCV-03
PB-03
PCV-03
PH-28
SM-09PH-27
PB-03
32.28 m
3.93 m
10.83 m
13.3 m
PB-03
SITUACIÓN
?
HIDROGEOLOGÍA
Cálculos previos
TIEMPO ESTIMADO:
SI:φ = 0.2T = 300m/db = 15 mentonces k = 20 m/dQB = 5 l/s
r1 = distancia PH-27 = 3.93 m
r2 = distancia SM-09 = 13.3 m
t0 = (b·π·φ·r2) / Q
t01 = (15·π·0.2·(3.93)2) / (5·86.4) = 0.35 d
t02 = (15·π·0.2·(13.30)2) / (5·86.4) = 19.3 d
Ttotal = 3 a 4 t0
Ttotal1 ≈ 3 a 4 (0.35) ≈ 1.4 dTtotal2 ≈ 3 a 4 (19.3) ≈ 60 d
MASA ESTIMADA:
Cmax ≈ 100 a 1000 C*C1* ≈ 0.1 mg/l (g/m3)C2* ≈ 0.1 µg/l (mg/m3)
M ≈ 2·Q·t0·Cmax
C1max ≈ 10 - 100 g/m3
C2max ≈ 0.01 - 0.1 g/m3
M1 ≈ 2·(5·86.4)·(0.35)·10 ≈ 3024 gM2 ≈ 2·(5·86.4)·(13.30)·0.01 ≈ 115 g
PB-03
PH-27
VERTIDO ALCANTARILLA
CAUDALIMETRO POZO DE BOMBEO
POZO DE INYECCION
3.93 m
BIDON ≈≈ 100 L
EMBUDO
TRAZADO 1ER PIEZÓMETRO (PH-27)
PROCEDIMIENTO
TRAZADO 1ER PIEZÓMETRO
A) SE VIERTEN 5 kg DE LiBr EN EL BIDÓN.
B) SI VAMOS A MEDIR Br,- ESTO REPRESENTA M=4600 g Br-
C) SE VIERTE EL CONTENIDO DEL BIDÓN EN EL PIEZÓMETRO.
D) CON UN BUEN SISTEMA SE AGITA LA SOLUCIÓN DENTRO DEL SONDEO PARA HOMOGENEIZAR LA MEZCLA
E) SE AÑADE 1 o 2 BIDONES MÁS DE AGUA AL PIEZOMETRO PARA DESPLAZAR EL TRAZADOR AL ACUIFERO
SM-09
PH-27
PB-03
13.30 m
TRAZADO 2º PIEZÓMETRO (SM-09)
A) SE VIERTEN 25.5 g DE FLUORESCEINA EN EL BIDÓN.
M = 25.5 g Fluoresceina
B) SE VIERTE EL CONTENIDO DEL BIDÓN EN EL PIEZÓMETRO.
C) SE AGITA LA SOLUCIÓN DENTRO DEL SONDEO PARA HOMOGENEIZAR LA MEZCLA
D) SE AÑADE 1 o 2 BIDONES MÁS DE AGUA AL PIEZÓMETRO PARA DESPLAZAR EL TRAZADOR AL ACUÍFERO
SE AGITA BIEN !!
SE VIERTE EN EL PIEZÓMETRO....
....CON MUCHO CUIDADO !!
- SE AGITA BIEN DENTRO DEL PIEZÓMETRO
- SE AÑADE AGUA AL PIEZÓMETRO
SE MIDE CON LOS EQUIPOS DE CAMPO:
- ELECTRODO SELECTIVO DE Br-
- CE / Tª
- SE TOMAN LAS MUESTRAS (4 POR HORA, 125 ml)
Resultados iniciales
-100
-80
-60
-40
-20
0
20
40
60
80
100
22/11/00 11:00 23/11/00 11:00 24/11/00 11:00 25/11/00 11:00 26/11/00 11:00
2.00
2.05
2.10
2.15
2.20
2.25
2.30
Potencial (mV)
Conduct. (mS)
Caudal (m3/d)
050
100
150200250300350
400450500
22/11/00 11:00 23/11/00 11:00 24/11/00 11:00 25/11/00 11:00 26/11/00 11:00
?¿
Posibles problemas:
recirculacion agua
espesor (b) no constante
bombeo no constante
heterogeneidad
mal funcionamiento equipos
etc
Alcantarilla
Recirculación
b b’ b’’
Ar
en
as
f
in
as
!
!?
?
HETEROGENEIDAD
Br-EN CAMPO SE OBTIENEN CURVAS “RARAS”
SOLUCIÓN PATRÓN CON DIVERSAS CONCENTRACIONES DE Br-Y SE MIDE EL POTENCIAL Y SE CORRELACIONAN.
LOS RESULTADOS DE CAMPO ESTAN “MAL”
UNA PELÍCULA DE PARTICULAS FINAS ENSUCIA EL ELECTRODO DE MEDIDA.SE ARREGLA Y VUELVE A MEDIR BIEN. SE CALIBRA CON LOS PATRONES.
SE MIDE EL POTENCIAL DE NUEVO EN TODAS LAS MUESTRAS Y SE CORRELACIONA CON LA CONCENTRACIÓN.
SE OBTIENE, POR FIN,LA CURVA DE LLEGADA DEL Br-
FLUORESCEINA
PARA LA FLUORESCEINA SE HACEN DOS SESIONES:
1ª SESIÓN: IDENTIFICACIÓN Y LOCALIZACIÓN DEL PICO
2ª SESIÓN: CUANTIFICACIÓN DEL PICO
ppb (Fluoresceina)
0.0000
0.1000
0.2000
0.3000
0.4000
0.5000
0.6000
0.7000
0.8000
0 1000 2000 3000 4000 5000 6000
Serie1
Serie2
y = -31.393x + 80.928R2 = 0.9849
0
20
40
60
80
100
0 0.5 1 1.5
ml ini ml tot mol mol tot conc logc E mV0 20 0 0 0 #¡NUM! 82
0.5 20.5 2.17E-07 2.17E-07 1.260866 0.100669 750.75 21.25 3.26E-07 5.43E-07 3.040912 0.483004 67
1 22.25 4.34E-07 9.77E-07 5.227635 0.718305 601.24 23.49 5.39E-07 1.52E-06 7.6806 0.885395 541.5 24.99 6.52E-07 2.17E-06 10.32255 1.013787 491.75 26.74 7.6E-07 2.93E-06 13.0302 1.114951 44
2 28.74 8.69E-07 3.8E-06 15.7209 1.1964775 33.74 2.17E-06 5.97E-06 21.05205 1.32329410 43.74 4.34E-06 1.03E-05 28.05787 1.44805515 58.74 6.52E-06 1.68E-05 34.09404 1.532678
Br-
0
5
10
15
20
25
30
0 20 40 60 80 100 120 140 160 180
muestras
mg/
l Br
-
RESULTADOS
masa inyectada (g) 4600caudal medio (l/s) 4.7espesor aq (m) 15distancia inyec-bomb (m) 3.93
porosidad
t0 = (pi*b*m*r2)/Q
t0 (h) = 11.8 horas
m = (t0 * Q) / (pi * b * r2) = 0.274
coef. dispersión
sigma1(11.2%) horas = 8.5 0.138sigma2(58.8%) horas = 43 1.300
Vel (m/d) = 7.99
vel=Q/(2*pi*b*m*r) = 4.00D (m2/d) = (sigma^2 * Vel^2) / (2 * t0) = 8.39 m2/d
0.3127.45
dispersivitatalfa = D / Vel 2.10 m
0.086.869
[mg/l] Br
0
5
10
15
20
25
0 24 48 72 96
c/c0 (%)
0
10
20
30
40
50
60
70
80
0 24 48 72 96
σ1
σ2
t0
Resultados Analíticos
masa inyectada (g) 4600caudal medio (l/s) 4.7espesor aq (m) 15distancia inyec-bomb (m) 3.93
porosidad
t0 = (pi*b*m*r2)/Q
t0 (h) = 9.33 horas
m = (t0 * Q) / (pi * b * r2) = 0.217
coef. dispersión
sigma1( 7 %) horas = 7 0.097sigma2(37%) horas = 12.3 0.124
Vel (m/d) = 10.11
vel=Q/(2*pi*b*m*r) = 5.05D (m2/d) = (sigma^2 * Vel^2) / (2 * t0) = 0.40 m2/d
0.310.50
dispersivitatalfa = D / Vel 0.08 m
0.060.100
[mg/l] Br
0
5
10
15
20
25
0 24 48 72 96
c/c0 (%)
0
10
20
30
40
50
0 2 4 6 8 10 12 14 16 18 20 22 24
σ1
σ2
t0
*ajuste de las 24 h (1º tramo) del anterior
masa inyectada (g) 25.5caudal (l/s) 4.7espesor aq (m) 15distancia inyec-bomb (m) 13.3
porosidad
t0 = (pi*b*m*r2)/Q
t0 (h) = 82
m = (t0 * Q) / (pi * b * r2) 0.166
coef. Dispersión (D)
sigma1(16% = 0.25%) horas 64.58 0.726sigma2(84% = 1.35 %) horas 105 0.958
Vel (m/d) = 3.89
vel=Q/(2*pi*b*m*r) = 1.95D (m2/d) = (sigma^2 * Vel^2) / (2 * t0) = 0.39 m2/d
0.290.51
dispersivitatalfa = D / Vel 0.20 m
0.150.26
lambda L = (ln(c2)-ln(c1))/(t1-t2) = 0.05686883
[ppb] Fluoresceina
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0 24 48 72 96 120 144 168 192
c/c0 (%)
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
0 24 48 72 96 120 144 168 192
σ1
σ2
t0
10 10
r (m) b (m) Q (l/s) BROMURO r (m) b (m) Q (l/s) FLUORESCEINA3.93 15 4.7 13.3 15 4.7Pe Cd C(g/m3) td t (horas) Pe Cd C(g/m3) td t (horas)40 0.7 10 1.1 10 100 0.31 0.1 1.2 100
Dispersivitat 0.098 m Dispersivitat 0.133 m
porositat 0.211 porositat 0.169
masa 2197.403 g masa 454.839 g
resultados segun curvas tipo (Carrera y Walters, 84) resultados segun curvas tipo (Carrera y Walters, 84)
1 . 0 0
1 0 . 0 0
1 0 0 . 0 0
0 . 1 0 1 . 0 0 1 0 . 0 0 1 0 0 . 0 0t
C
0 . 0 1
0 . 1 0
1 . 0 0
1 . 0 0 1 0 . 0 0 1 0 0 . 0 0 1 0 0 0 . 0 0
t
C
AJUSTE POR CURVAS TIPO (CARRERA Y WALTERS, 84)
160 180 200 220 240 260 280 300 320 340
160
180
200
220
240
260
280
300
320
340
240 242 244 246 248 250 252 254 256 258 260 262 264240
242
244
246
248
250
252
254
256
258
260
262
264
PH-28
SM-09PH-27
PB-03
MODELACIÓN
MEDIO HOMOGENEO E ISOTROPOFLUJO RADIAL (Q = 4.7 l/s)VALORES PREVIOS:
T=300 m2/dS= 0.2POROSIDAD = 0.2DISPERSIVIDAD (m) = 0.1 RETARDO = 1
-0.35-0.3
-0.25-0.2
-0.15-0.1
-0.050
0.05
0 1 2 3 4 5 6
tiempo
niv
ele
s
CALCULADOP-A MEDIDOP-A
-0.8
-0.6
-0.4
-0.2
0
0.2
0 1 2 3 4 5 6
tiempo
niv
ele
s
MEDIDOP-C CALCULADOP-C
-0.7-0.6-0.5-0.4-0.3-0.2-0.1
00.1
0 1 2 3 4 5 6
tiempo
niv
ele
s
CALCULADOP-B MEDIDOP-B
-1.4
-1.2
-1
-0.8
-0.6
-0.4
-0.2
0
0 1 2 3 4 5 6
tiempo
niv
ele
s
CALCULADOP-D MEDIDOP-D
-4-3.5
-3-2.5
-2-1.5
-1-0.5
00.5
0 1 2 3 4 5 6
tiempo
niv
ele
s
CALCULADOP-BOM MEDIDOP-BOM MODELACIÓNPARAMETROS DE FLUJO:T (m2/d) = 161S = 0.16
0
500
1000
1500
2000
2500
0 1 2 3 4 5 6
tiempo
con
cen
trac
ion
CALCULADOP-B MEDIDOP-B
0
1000
2000
3000
4000
5000
6000
7000
0 1 2 3 4 5 6
tiempo
con
cen
trac
ion
CALCULADOP-D MEDIDOP-D
0
5
10
15
20
25
30
0.00 1.00 2.00 3.00 4.00
tiempo
coce
ntr
acio
n
CALCULADOP-BOM MEDIDOP-BOM
012345678
2.00 2.50 3.00 3.50 4.00
tiempo
co
ce
ntr
ac
ion
CALCULADOP-BOM MEDIDOP-BOM
MODELACIÓN
modeloBr Fluoresceina Br Fluoresceina
T (m2/d) 161K (m/d) 10.7
S 0.16
porosidad 0.22 0.166 0.21 0.169 0.16Dispersividad long (m) 0.08 0.15 0.098 0.133 0.1
Dispersividad transv (m) 0.05retardo 1.25
analitico c. Tipo
Resumen de los resultados
CONCLUSIONES ENSAYOS DE TRAZADORES
•Diseño previo
•precauciones•tipo trazador•tiempo•masa•inyección•medidas
•valores obtenidos
•coherencia entre métodos
0
5
10
15
20
25
30
0.00 1.00 2.00 3.00 4.00
tiempo
coce
ntr
ac
ion
CALCULADOP-BOM MEDIDOP-BOM
INYECCIONBr
INYECCIONFluoresceina
Curva de llegada
Bombeo