µelan max datasheet

4
www.conzerv.com ISO 14001:2004 Certified ISO 9001:2000 Certified μeLAN Max ® ® μeLAN Max an Innovative, Cost Effective Software to Monitor & Reduce your Electrical Energy Bills. A pre-packaged, plug & play system. 29 1 2 4 5 59 3 33 31 32 34 35 89 61 62 64 65 119 91 92 94 95 63 93 Data Logger 30 Data Logger 60 Data Logger 90 1 Data Logger 120 2 .... 24 1 2 .... 24 1 2 .... 24 1 2 .... 24 1 μeLAN Max Energy Management Networks ® Trends Setup Screen Database Alarm ueLAN Report Screen Converter RS 485 DATA CONVERTER CD 485i System log Screen ueLAN Main Screen History Reports Screen Dashboard Mimic (EM) ® μeLAN Max DATA REPEATER DATA REPEATER DATA REPEATER Repeater Repeater Repeater Have Free Trial of this Software for 5 EM 6400 for 60 Days

Transcript of µelan max datasheet

Page 1: µelan max datasheet

www.conzerv.com

ISO 14001:2004 Certified

ISO 9001:2000 Certified

μeLAN Max®

®μeLAN Max an Innovative, Cost Effective Software to Monitor & Reduce

your Electrical Energy Bills. A pre-packaged, plug & play system.

29

1

2

4

5

59

3 33

31

32

34

35

89

61

62

64

65

119

91

92

94

95

TM

cooLite

0%

TM

cooLite

0%

63

TM

cooLite

0%

93

TM

cooLite

0%

Data Logger

30Data Logger

60Data Logger

90

1

Data Logger

120

2....

2412....

241 2....

241 2....

241

μeLAN Max Energy Management Networks

®

Trends

Setup Screen

DatabaseAlarm

ueLANReport Screen

ConverterACTIVITY POWER SUPPLY

RS 485 DATA CONVERTER CD 485i

232 485 232 485OPTICALISOLATED

System log Screen

ueLAN Main Screen

History Reports ScreenDashboard

Mimic (EM)

ISO 14001:2004 Certified

ISO 9001:2000 Certified

® μeLAN Max

DATA REPEATER

232 485 232 485OPTICALISOLATED

ACTIVITY POWER SUPPLY

DATA REPEATER

232 485 232 485OPTICALISOLATED

ACTIVITY POWER SUPPLY

DATA REPEATER

232 485 232 485OPTICALISOLATED

ACTIVITY POWER SUPPLY

Repeater

Repeater

Repeater

Have Fr

ee Trial

of this

Softw

are

for 5

EM 6400

for 6

0 Day

s

Page 2: µelan max datasheet

Email [email protected] www.conzerv.com

®μeLAN Max is totally indigenous, State of the art SCADA

®Software Package that runs under Windows operating system and supports standard features of electrical energy

®management system. μeLAN Max communicates with one hundred twenty devices (any combination of EM 3000, EM 6400, EM 6438, EM 6600, CVM96, CVM144, Data logger and

TM ®cooLite ). μeLAN Max supports online monitoring of various parameters, power quality analysis, generating history information and periodic report.

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

Multi user login

Tabular view provided in HMI

Print and snapshot of HMI Screens

History log view in tabular form giving tag names & time stamp for comparison of data

Easy to install, plug and play

Report based on Crystal Reports

Reports like energy consumption, specific energy consumption, power interruption, demand, log reports, energy intensity, generator reports, energy balance reports & energy export reports, breaker status

Trial Mode option for 60 days

Graphical visualization of energy consumption, specific Energy consumption and energy intensity

Enable /Disable of nodes

MS SQL Server Express 2005 Support

Option to Store data in XML Format to generate customized reports

Load center groups to group load centers

ConPAD integration for remote meter programmingTM

Integration with Energy Billing System (eEBS )TM

Integration with cooLite with timer scheduler TM

(subjected to cooLite having EM 6620 Meter)

Product Registration

Energy - Demand Dash boards

*

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

Hourly Consumption Reports

Daily shift wise Consumption Report

Day to Day Consumption Report

Daily shift wise Demand Report

Daily shift wise Power Interruption Report

Daily shift wise Log Report

Data logger Report

Day to Day Demand Report

Day to Day Power Interruption Report

Daily shift wise Energy Export Report

Day to Day Energy Export Report

Daily shift wise Energy Balance Reports

Day to Day Energy Balance Reports

Daily shift wise Breaker status Report

Daily shift wise power quality /harmonics Report

All Report can be Auto generated & e-mailed to specifics email - Id’s

Reports

Benefits

+

+

+

+

+

+

+

+

+

+

Helps to monitor and reduce specific energy consumption

Reduces demand cost - Demand optimization

Load Management

History analyses for a set period - History log view

Helps to measure energy export

Helps to measure energy intensity in buildings

Helps to save lighting energy consumption

Helps in analysis of energy balance

Helps power Harmonics analysisTM

Helps in Lighting Energy Savings with cooLite

* Trial mode option without hardware key for one EM 3000,Five EM 6400, TM

one EM 6438, one EM 6600, one data logger and one cooLite models are available for 60 days

Features

μeLAN Max Software Specification

®

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

No. of meters or devices : Any combination upto 120 (EM 3000,EM 6400,EM 6438

EM 6600, CVM96, CVM144, )

No. of Parameters per EM 3000 : 21TM

No. of Parameters per EM 6400 : 22 for DigitAN & 17 for PowerMax

No. of Parameters per EM 6438 : 15

No. of Parameters per EM 6600 : 19

No. of Parameters per CVM96 : 87

No. of Parameters per CVM144 : 132

No. of Parameters per : 24TM

No. of Parameters per cooLite : 22

No. of Mimic Pages (Value Display) : Based on the number of devices configured

No. of Trend Pages : Based on the number of EM 3000, EM 6400,EM 6438,EM 6600,

CVM96, CVM144 devices,

No. of Matrix Pages : 12

No. of pens per trend : 8 Preset. Maximum is 20

Archiving : Supported on Windows compatible internal or external HDD or

MO Drive. (Requires drivers from drive supplier)

Duration of storage of historical data in HDD : Storage until 90% of HDD is full, after which old data will be

purged.

Alarms : Arranged in 16 Groups. (Can be set by entering values of tag

triggering limits)

Licensing : Piracy protection through USB key

TMData logger and cooLite

Data logger

TMData logger and cooLite

Page 3: µelan max datasheet

Email [email protected] www.conzerv.com

Power InterruptionsReportsDaily

Data LoggerReportsDay to Day

Power InterruptionsReportsDay to Day

Data Logger ReportsDaily

Reports Formats

System Requirements

+

+

+

+

+

+

+

+

+

PC : Intel Core 2 Duo or higher

RAM : Minimum 1GB RAM up to 60 nodes

and 2 GB RAM for more than 60

nodes

Hard disk capacity : 1) Less than 30 nodes 80 GB

Minimum

2) Greater than 30 nodes 200 GB

Minimum

Minimum 5GB required before

installation

Monitor resolution : 1024 x 768 with minimum 256

colors or higher

Serial ports : COM1 to COM 4 ports, any one

only

USB port : Required for USB l icence

installation

CDROM drive : 48X or above

Hard Disk portion : C & D Drive

Ethernet Port : One

Hardware

+

+

+

®Operating system : Windows XP Professional with

®SP3/Windows Vista with SP1

Web Browser : IE 7 or any other browser

Office Suite : MS Office 2003 or higher.

Network Components

Option1 :Data converter, Data Repeater

(Moxa)& Data cable

Option2 :Ethernet Converter

Option3 :OFC Converter

Option4 :Wireless Devices & Ethernet

Option5 :Data logger & Pulse input

Option6 :GPRS/GSM based system

*

Conzerv Meters : 1 to 120 Devices / Remote Units

(EM3000, EM6400, EM6438, EM6600, CVM96, CVM144,

)

Data TM

logger and cooLite

Software

Devices (RTU)

b) Customer Name :..........................

Note : Total can be maximum of 120 nos.

Ordering Information

a) Specify

Models

Quantity

EM 3000 EM 6400 EM 6438 EM 6600

______ ______ ______ ______CVM 96 CVM 144 Data logger

TMcooLite

______ ______ ______ ______

* Repeaters ( Moxa) are required to support more than 30 devices

or supporting data cable lengths of more than 800 meters

DemandReportsDaily

Page 4: µelan max datasheet

®SEC\μ

eLAN

MaxN

\0809\V

2.3

Log ReportsDaily

Consumption ReportsDay to Day

Energy Consumption Report - Hourly

Energy ExportReport - Daily

DemandReports Day to Day

Consumption ReportsDaily

Energy Balance Report - Daily

Breaker StatusReport - Daily

Power QualityReport - Daily

Schneider Conzerv strives for continuous product innovation. Product specifications are therefore subject to change without notice.

Schneider Electric Conzerv India Pvt Ltd.

44P Electronic City East Phase Hosur Road, Bangalore 560 100 INDIA

+91 80 4118 9700, +91 80 4118 9729 [email protected]

Help Desk 1800 425 0555 (Toll Free All India from BSNL / MTNL lines) Or Call 080 2852 0604 (Standard Charges Apply)

P F E