Pinssar’s READER is a ruggedised real-time smart monitoring device to sample diesel particulates. P sa Technical Specification for RFTRE04 Measurement Technique Laser-light scattering photometry Concentration Range 0 to 2,500μg/m3 Self-Cleaning The optical cell is flushed with filtered air after each sample is taken. Measurement Frequency Pre-set at every 3.5 to 4 minutes with an interval between Zero Drift Negligible; uses an internally designed auto-zero system Remote Management Managing of Reader device can be done remotely via AAMS Server software Size Fraction ≤ 0.8μm Particulate Type Particulate Mass is calibrated to the response of a reference photometer gravimetrically calibrated to diesel particulate matter (<800nm). Dimensions With external filter 660mm(H) x 250 mm(D) x740mm (W) Without external filter 660mm(H)x 250mm(D)x 675mm(W) Mass 29.7 kg Flow Rate 2.2 litres per minute Operating Humidity Range 70 to 90% relative humidity (non-condensing) Operating Temperature Range -10°C to 60°C, 14°F to 140°F Enclosure Material Stainless Steel (316 grade) Amphenol: RJFTV21N panel mount Amphenol:RJFTV6MN cable mount plug IP Rating IP64 Internal Clock Sync to UTC (require internet access or SIM option) Sample Data Characteristics Timestamp: Year, Month, Day, Hour, Minutes and Seconds Package size: 52 bytes Supporting Data Includes physical location, unique identifier, IP address, serial number and sample value through the Dashboard Application. Internal Data Storage 2GB CF Card Diagnostics Reader device status reported via the AAMS Server Software Power Option Universal power supply 110-240VAC Battery: 6AH-14VDC LiFePO4 (internally mounted) Surge protect 110VAC to 240VAC Variant: 3kV isolation in accordance with EN60950 Circuit Break Push to reset: 3.15amp 250VAC Identification Labelling Serial number plate on right hand side panel Data Communication scenarios See scenario list on following page Data Communication Interface Options Serial: USB Ethernet: 10/100Base TX (Cat5 RJ45) Wireless: LTE/UMTS (HSPDA/HSPDA+), WiFi (IEEE 802.11b,g,n) Compliances EMC AS/NZS CISPR 22 Class A Safety AS/NZS 60950 EMC FCC part 15 EMC CA/CSA JULY 2016 Dashboard D.P.M. Reader Pinssar’s Dashboard is included with each Reader. It is an easy to use and confi gurable HMI. It records and displays samples from the Reader in terms of values as well as internal diagnostics. Functions include: CONSOLE : Tabulates samples for the current shift and previous shifts. READER STATUS : Indicates if power is on and or the communications are not active, or operating as intended as well as the status of the internal components. READER MAP : Records the location of each Reader. CHART : A real time visual display of samples. ADMINISTRATION : Provides installation and site confi guration details. PATENT INFORMATION PATENT INFORMATION - AU Pat App No. 2016902308 - AU Pat App No. 2016902308 samples taken.

Transcript of D.P.M. Reader Dashboard -...

Page 1: D.P.M. Reader Dashboard - Pinssarpinssar.com.au/wp-content/uploads/2016/07/Pinssar-spec-sheet-july... · Alstom Alspa TCP/IP Master via SRTP BACNet 802.3 Master Richards-Wilcox Intelligent

Pinssar’s READER is a ruggedised real-time smart monitoring device to sample diesel particulates.Psa

Technical Specification for RFTRE04 Measurement Technique Laser-light scattering photometry Concentration Range 0 to 2,500μg/m3 Self-Cleaning The optical cell is flushed with filtered air after each sample

is taken. Measurement Frequency Pre-set at every 3.5 to 4 minutes with an interval between

Zero Drift Negligible; uses an internally designed auto-zero system Remote Management Managing of Reader device can be done remotely via AAMS

Server software Size Fraction ≤ 0.8μm Particulate Type Particulate Mass is calibrated to the response of a reference

photometer gravimetrically calibrated to diesel particulate matter (<800nm).

Dimensions With external filter 660mm(H) x 250 mm(D) x740mm (W) Without external filter 660mm(H)x 250mm(D)x 675mm(W)

Mass 29.7 kg Flow Rate 2.2 litres per minute Operating Humidity Range 70 to 90% relative humidity (non-condensing) Operating Temperature Range -10°C to 60°C, 14°F to 140°F Enclosure Material Stainless Steel (316 grade)

Amphenol: RJFTV21N panel mount Amphenol:RJFTV6MN cable mount plug

IP Rating IP64 Internal Clock Sync to UTC (require internet access or SIM option) Sample Data Characteristics Timestamp: Year, Month, Day, Hour, Minutes and Seconds

Package size: 52 bytes Supporting Data Includes physical location, unique identifier, IP address, serial number and sample value through the Dashboard Application.

Internal Data Storage 2GB CF Card Diagnostics Reader device status reported via the AAMS Server Software Power Option Universal power supply 110-240VAC

Battery: 6AH-14VDC LiFePO4 (internally mounted) Surge protect 110VAC to 240VAC Variant: 3kV isolation in accordance with

EN60950 Circuit Break Push to reset: 3.15amp 250VAC Identification Labelling Serial number plate on right hand side panel Data Communication scenarios See scenario list on following page Data Communication Interface Options

Serial: USB Ethernet: 10/100Base TX (Cat5 RJ45) Wireless: LTE/UMTS (HSPDA/HSPDA+), WiFi (IEEE 802.11b,g,n)

Compliances EMC AS/NZS CISPR 22 Class A Safety AS/NZS 60950 EMC FCC part 15 EMC CA/CSA

JULY 2016

Dashboard

D.P.M.Reader

Pinssar’s Dashboard is included with each Reader. It is an easy to use and confi gurable HMI.It records and displays samples from the Reader in terms of values as well as internal diagnostics. Functions include:

• CONSOLE : Tabulates samples for the current shift and previous shifts.• READER STATUS : Indicates if power is on and or the communications are not active, or operating as intended as well as the status of the internal components.• READER MAP : Records the location of each Reader.• CHART : A real time visual display of samples.• ADMINISTRATION : Provides installation and site confi guration details.

PATENT INFORMATIONPATENT INFORMATION - AU Pat App No. 2016902308 - AU Pat App No. 2016902308

samples taken.

Page 2: D.P.M. Reader Dashboard - Pinssarpinssar.com.au/wp-content/uploads/2016/07/Pinssar-spec-sheet-july... · Alstom Alspa TCP/IP Master via SRTP BACNet 802.3 Master Richards-Wilcox Intelligent

Serial Drivers

ABB COMLINK MasterAC Tech Simple ServoAdam 4000 Series ModulesAllen-Bradley DF1 MasterAllen-Bradley DH485Allen-Bradley Native Tag AddressingAllen-Bradley Ultra 3000Alpha Gear TernaryApplied Motion SCLAlstom GEM80 ESP J/K Master or SlaveAlstom GEM80 ESP Program Port Master

IMO PLC-CNETIndramat CLC MasterIntelligent Actuator XSELIntelligent Actuator, RobocylinderIrcon ModlineJohnson Controls Metasys N2 SlaveJulabo Circular HeadKEB DIN66019II Master or SlaveKeyence KV Series PLCKing KingBus ASCIIKlockner Moeller PS4-201

Installation Example A

Danfoss VLT SeriesDeviceNetDupline Mastergenerator via ModbusEaton ELC MasterElmo DrivesEmco FP-93Emerson Process, ROC, ROC EnhancedEmerson-Control Techniques QuantumEurotherm- BISYNCH ASCIIEZ Automation EZ MasterFatek PLCFesto FPC, IPC, FEC, Series ControllerFlowCom MasterGalil

MODBUS Universal MasterMotrona LECOM MasterMP Electronics GTI SeriesMTS DDA Master or SlaveMTS Modbus MasterOmron C Series PLCOmron Master via FINSOmron Series C PLC

Panasonic FP Series MEWTOCOL & DAT (BinaryParker Acroloop Motion ControllerParker Computmotor 6K MasterPason WITSPhoenix Contact nanLC

Installation Example C

Ethernet Drivers

ABB COMLINK MasterAC Tech Simple Servo UDPAcromag TCP/IP MasterAdenus TelnetAllen Bradley L5KAllen Bradley DF1 Master via PCCC/EIPAllen Bradley DF1 TCP/IP MasterAllen Bradley Native Tag AddressingAlstom GEM80 ESP TCP/IP MasterAlstom Alspa TCP/IP Master via SRTPBACNet 802.3 Master

Richards-Wilcox Intelligent Storage SystemsSchneider-PLC via ModbusSchneider-Telemechanique TSX47 MasterSchneider-Telemechanique UniTelwaySiemens S5 via AS511Siemens S7 via MPI AdaptorSiemens S7 via PPISiemens USS DrivesSiemens TI-500 SeriesSEW Movilink A or B MasterSMA Data Master

Installation Example B

Galil TCP/IPGE TCP/IP Master via SRTPHoneywell S9000

KEB DIN66019II TCP/IP MasterMaquire MLAN TCP/IPMicroscan- Vision Hawk CameraMitsubishi A/Q Series UDP or TCP/IP MasterMitsubishi Q Series TCP/IP MasterMitsubishi FX2 seriesMODBUS TCP/IP Master or SlaveMODBUS Encapsulated MODBUS MasterMODBUS Gateway

Yokogawa FA-M3 PLC MasterInstallation Example D

Ordering Information

Each Pinssar Reader containsEach Pinssar Reader containsMonitoring deviceChoice of communication interfaceAPI (Application Programming Interface) document

Customer Support and Maintenance ProgramIncluding:

- Technical support: telephone and email - 12 month warranty - Annual calibration

- Upgrade program

For a detailed quotation:

Call +61 7 3118 1733

Email [email protected]

Time Zone: Brisbane, Australia (UTC+10:00)

www.pinssar.com.au

ABN 35 167 711 622Contact DetailsCorporate House2404 Logan RoadEight Mile Plains Brisbane Queensland 4113Australia

LAN/WAN

LAN/WANLAN/WAN

JULY 2016

Pinssar “Dashboard” Software

Reader - Collects samples and pushes data to the AAMS Dashboard repository on the server.LAN/WAN - The Reader then communicates with the AAMS Dashboard on the server direct connect. (LAN/Wireless) via the web from any remote location. Many protocols are supported including ethernet - TCP/IP and MODBUS.AAMS Dashboard - SERVER - The dashboard has both server and end-user client applications.the server has a light footprint embedded - relational data base repository (SQlite).Other commercially available RDBMS are also supported.Client - Users access the system via web browser. A range of user interfaces are supported on computers/laptops (PC and Mac) tablets (Android and Apple) and all printer types.MODBUS/TCP - This is the primary protocol supported when the Reader is directly connected to a SCADA/DCS system or PLC.SCADA/DCS- Either the Reader or the AAMS Dashboard server application can interface with all major venfors

- Break fix