DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring...

21

Transcript of DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring...

Page 1: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button
Page 2: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

DIGITAL MULTIMETER DESCRIPTION

1. Range Control Button

2. Data Hold Button

3. AC/DC Current or Selecting

Button

4. Socket for transistor test

5. Function switch/Power switch

6. V/Ω/F Input Jack

7. COM Input Jack

8. mA/Cx Input Jack

9. 10A Input Jack

1. Range control button

Range for AC/DC voltage, AC/DC current (µA and mA only), resistance and frequency

measuring can be selected manually or handled by autoranging. Push this button as following to

choose range control mode and desired ranges.

Page 3: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

2. Data hold button When this button is pushed, the display will show the last reading and “D-H” symbol will appear

until pushing it again.

Data holding will be cancelled automatically when the function switch is rotated.

3. AC/DC current or Selecting button Push this button to select AC or DC current measuring function when the function switch is set

at µA, mA, A positions.

Push this button to select measuring function when the function switch is set at

position.

4. Input jacks This device has four input jacks that are protected against limits overload. During use, connect

the black test lead to the COM jack and the red test lead as shown below:

Function Red lead connection Input limits

DCV/ACV V / Ω / F 1000V DC or 750V rms AC

kHz V / Ω / F 250V DC or rms AC

Ω/ V / Ω / F 250V DC or rms AC

µA / mA mA / Cx 300mA DC or rms AC

nF / µF mA / Cx 300mA fuse protected

A 10A 10A DC or rms AC

µA / mA ranges are protected by fuses.

Page 4: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

SPECIFICATIONS

1. General Display: LCD, 3260 counts max.

Max. Voltage

Between Terminals

and Herat Ground

1000V DC o 750V rms AC

Fuse Protection µA, mA: F 300 mA / 250V

Measurement

Method Dual slope integration A/D converter

Ranging Method Auto/Manual

Overrange Indication “OL” display

Polarity Indication “-“ display

Power supply: 9V battery, NEDA 1604 o 6F22

Operating: 0 to 40 ºC (32ºF to 104ºF) Temperature

Storage: -10ºC to 50ºC (10ºF to 122ºF) Operating

conditions: Humidity < 80%

Dimension: 91 x 189 x 31.5 mm

Weight: 310 gr.

2. DC Voltage Range Resolution Accuracy

326mV 0.1mV ± 0.5% of rdg ± 2 digits

3.26V 1mV ± 0.8% of rdg ± 2 digits

32.6V 10mV ± 0.8% of rdg ± 2 digits

326V 0.1V ± 0.8% of rdg ± 2 digits

1000V 1V ± 0.8% of rdg ± 2 digits

Input impedance: 10MΩ, more than 100MΩ at 326mV range.

Page 5: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

3. AC Voltage

Range Resolution Accuracy

3.26V 1mV ± 1.2% of rdg ± 3 digits

32.6V 10mV ± 0.8% of rdg ± 3 digits

326V 0.1V ± 1.2% of rdg ± 3 digits

1000V 1V ± 1.2% of rdg ± 3 digits

Input impedance: 10MΩ.

Frequency range: 40 to 400Hz, 40 to 200Hz for 3.26V range.

Response: average, calibrated in rms of sine wave.

4. DC Current Range Resolution Accuracy Burden Voltage

326µA 0.1µA ± 1.2% of rdg ± 3 digits 0.5mV / µA

3260µA 1µA ± 1.2% of rdg ± 3 digits 0.5mV / µA

32.6mA 10µA ± 1.2% of rdg ± 3 digits 8.0mV / mA

326mA 0.1mA ± 1.2% of rdg ± 3 digits 8.0mV / mA

10A 10mA ± 4.0% of rdg ± 3 digits 0.02V / A

Overload Protection: F 300mA fuse for µA and mA ranges.

5. AC Current Range Resolution Accuracy Burden Voltage

326µA 0.1µA ± 1.5% of rdg ± 5 digits 0.5mV / µA

3260µA 1µA ± 1.8% of rdg ± 5 digits 0.5mV / µA

32.6mA 10µA ± 1.8% of rdg ± 5 digits 8.0mV / mA

326mA 0.1mA ± 2.0% of rdg ± 5 digits 8.0mV / mA

10A 10mA ± 5.0% of rdg ± 7 digits 0.02V / A

Overload protection: F 300mA fuse for µA and mA ranges.

Frequency range: 40 to 400 Hz

Response: average, calibrated in rms of sine wave.

Page 6: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

6. Resistance Range Resolution Accuracy

326Ω 0.1Ω ± 1.0% of rdg ± 3 digits

3.26kΩ 1Ω ± 1.0% of rdg ± 1 digits

32.6 kΩ 10Ω ± 1.0% of rdg ± 1 digits

326 kΩ 100Ω ± 1.0% of rdg ± 1 digits

3.26MΩ 1kΩ ± 1.0% of rdg ± 1 digits

32.6MΩ 10kΩ ± 2.0% of rdg ± 2 digits

Maximun open circuit voltage: 1.3V

7. Capacitance Range Resolution Accuracy

326nF 0.1nF ± 5.0% of rdg ± 10 digits

32.6µF 10nF ± 5.0% of rdg ± 10 digits

8. Frequency Range Resolution Accuracy

32.6kHz 10Hz ± 1.5% of rdg ± 10 digits

150kHz 100Hz ± 3.0% of rdg ± 10 digits

Sensitivity: 500mV rms up to 50kHz, 1V rms for 50kHz to 150kHz.

BATTERY AND FUSE REPLACEMENT If the sign appears on the LCD display, it indicates that the battery should be replaced.

Remove screws on the back cover and open the case. Replace the exhausted battery with a

new one.

Fuse rarely need replacement, and when blows, it is almost always as a result of the operator’s

error. Open the case as mentioned above and take the PCB assembly out form the case.

Replace the blown fuse rating specified.

Warning: Before attempting to open the case, be sure that test leads have been disconnected

from measurement circuit to avoid electric shock hazard.

For protection against fire, replace fuses only with specified ratings: F1: F 300mA/250V.

Page 7: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

OPERATING INSTRUCTION 1. Measuring voltage

• Connect the black test lead to the COM jack and the red test lead to the V / Ω / F jack.

• Set the function switch at V V ~ range to be used and connect test leads across the

source or load under measurement.

• Read LCD display. The polarity of red connection will be indicated when making a DC

measurement.

2. Measuring current • Connect the black test lead to the COM jack and the red test lead to the mA/Cx jack for

a maximum of 300mA. For a maximum of 10A, move the red lead to the A jack.

• Set the function switch at µA, mA or A range to be used and push / ~ button to select

DCA or ACA measuring mode.

• Connect test leads in series with the load in which the current is to be measured.

• Read LCD display. The polarity of red lead connection will be indicated when making a

DC measurement.

3. Measuring resistance • Connect the black test lead to the COM jack and the red test lead to the V / Ω / F jack

(NOTE: The polarity of the red lead connection is positive “+”)

• Set the function switch at Ω range to be used and connect test leads across the

resistance under measurement. NOTE:

• For resistance above 3.26MΩ, the device may take a few seconds to stabilize reading.

This is normal for high resistance measuring. • When the input is not connected, i.e. al open circuit, the figure “OL” will be displayed for

the over-range condition • When checking in-circuit resistance, be sure the circuit under test has all power

removed and all capacitors are fully discharged.

Page 8: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

4. Measuring capacitance

• Connect the black test lead to the COM jack and the red test lead to the mA/Cx jack.

(NOTE: The polarity of the lead connection is positive “+”)

• Set the function switch al nF or µF position to be used. • Connect test leads across the capacitor under measurement and be sure that the

polarity of connection is observed. NOTE:

• When checking in-circuit capacitance, be sure that the circuit has all power removed

and all capacitor are fully discharged.

• The range control mode in capacitance measurement is manual ranging and only two

ranges (326nF, 32.6µF) are provided.

• If the range control button is used in this function measuring, decimal points may be at

incorrect positions.

• At the nF range, when the capacitor to be measured is not connected to test leads, the

LCD may not read zero, but a few counts. These counts have to be subtracted from

measuring results.

5. Measuring frequency • Connect the black test lead to the COM jack and the red test lead to the V / Ω / F jack.

• Set the function switch at the kHz position and connect test leads across the source or

load under measurement.

NOTE:

• The input voltage should be between 200mV and 10V rms AC. If the voltage is more

than 10V rms, reading may be out of the accuracy range.

6. Continuity & Diode test • Connect the black test lead to the COM jack and the red test lead to the V / Ω / F jack

(NOTE: The polarity of the red lead connection is positive “+”)

• Set the function switch at position and push the button to select continuity

or diode test mode.

• In continuity testing, if continuity exists (i.e., resistance less than about 50 Ω), built-in

buzzer will sound.

• If diode test mode is selected, connect the red and black leads to the anode and

cathode of diode under test. The forward voltage drop of this diode in V will be

displayed.

Page 9: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

7. Transistor test • Set the function switch al hFE position.

• Identity whether the transistor is NPN or PNP type and locate emitter, base and

collector lead. Insert leads of the transistor to be tested into proper holes of the testing

sockets on the front panel.

• LCD display will show the approximate hFE value at the test condition of base current

10µA and Vce 3.2V.

PRELIMINARY • When using the multimeter, the user must observe all normal safety rules concerning:

o Protection against the dangers of electrical current. o Protection of the meter against misuse.

• Full compliance with safety standards can be guaranteed only if used with test leads

supplied. If necessary, they must be replaced with the same model or same electric ratings.

Measuring leads must be in good condition.

DURING USE • Never exceed the protection limit values indicated in specifications for each of

measurement.

• When the device is linked to a measurement circuit, do not touch unused terminals.

• When the value scale to be measured is unknown beforehand, set the range selector at

the highest position.

• Before rotating the range selector to change functions, disconnect test leads from the

circuit under test.

• When carrying out measurements on TV or switching power circuits, always remember that

there may be high amplitude voltages pulses at test points which can damage the meter.

• Never perform resistance measurements on live circuits.

• Never perform capacitance measurements unless the capacitor to be measured has been

discharged fully.

• Always be careful when working with voltages above 60V DC or 30V AC rms. Keep fingers

behind the probe barriers while measuring.

Page 10: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

MAINTENANCE Before opening the device, always disconnect test leads from all sources of electric current.

For continue protection against fire, replace fuse only with specified voltage and current ratings: F1:

F 300mA/250V.

If any faults or abnormalities are observed, the multimeter can not the be used any more and it has

to be checked out.

Never use the meter unless the back cover is in place and fastened fully.

To clean the meter, use a damp cloth and mild detergent only, do not use abrasives or solvents on

it.

Page 11: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

MULTÍMETRO DIGITAL

PARTES DEL MULTÍMETRO

1. Botón para el control del rango

2. Botón “Data Hold””

3. Indicador de señal

4. Botón de selección AC/DC

5. Interruptor de funciones

6. Entrada V/Ω/F

7. Entrada COM

8. Entrada mA/Cx

9. Entrada 10A

1. Botón de control de rango El rango para la medida del voltaje AC/DC, corriente AC/DC (solo µA y mA), resistencia y

frecuencia debe ser seleccionado manualmente. Pulsar el botón, eligiendo el rango deseado.

Page 12: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

2. Botón Data hold Cuando el botón está pulsado, la pantalla visualizará el último valor leído y el símbolo “D-H”

deberá aparecer hasta que lo pulses otra vez.

La función data hold se cancelará automáticamente cuando se rote el interruptor de funciones.

3. Botón de selección o corriente AC/DC Pulsar dicho botón para seleccionar corriente AC o DC cuando el interruptor está cambiado a

las posiciones µA, mA, A.

Pulsar dicho botón para seleccionar la función de medida cuando el interruptor esté

cambiado a la posición .

4. Entradas Este multímetro posee cuatro entradas que están protegidas contra la sobrecarga de los límites

establecidos. Durante su uso, conectar el cable negro a la entrada COM y el rojo según lo

visualizado a continuación:

Función Conexión del cable rojo Límites de entrada

DCV/ACV V / Ω / F 1000V DC o 750V rms AC

kHz V / Ω / F 250V DC o rms AC

Ω/ V / Ω / F 250V DC o rms AC

µA / mA mA / Cx 300mA DC o rms AC

nF / µF mA / Cx 300mA fusible protegido

A 10A 10A DC o rms AC

Los rangos µA/mA están protegidos por fusibles.

Page 13: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

ESPECIFICACIONES TÉCNICAS

1. Generales

Pantalla: 3260 puntos max. LCD

Max. Voltaje entre

terminales y

conexión a tierra

1000V DC o 750V rms AC

Protección eléctrica µA, mA: F 300 mA / 250V

Método de medida Convertidor A/D de integración dual

Métodos del rango Auto/Manual

Indicador estado por

encima del rango “OL” en pantalla

Indicador de

polaridad “-“ en pantalla

Batería: 9V (Neda 1604 o 6F22)

Operativa: 0- 40 ºC (32ºF-104ºF) Temperatura

Almacenaje: -10ºC-50ºC (10ºF-122ºF) Condiciones de

funcionamiento: Humedad: < 80%

Tamaño: 91 x 189 x 31.5 mm

Peso: 310 gr.

2. Voltaje DC

Rango Resolución Precisión

326mV 0.1mV ± 0.5% (rdg ± 2 dígitos)

3.26V 1mV ± 0.8% (rdg ± 2 dígitos)

32.6V 10mV ± 0.8% (rdg ± 2 dígitos)

326V 0.1V ± 0.8% (rdg ± 2 dígitos)

1000V 1V ± 0.8% (rdg ± 2 dígitos)

Impedancia de entrada: 10MΩ, mas de 100MΩ a 326mV de rango.

Page 14: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

3. Voltaje AC

Rango Resolución Precisión

3.26V 1mV ± 1.2% (rdg ± 3 dígitos)

32.6V 10mV ± 0.8% (rdg ± 3 dígitos)

326V 0.1V ± 1.2% (rdg ± 3 dígitos)

1000V 1V ± 1.2% (rdg ± 3 dígitos)

Impedancia de entrada: 10MΩ.

Rango de frecuencia: 40 de 400Hz, 40 de 200Hz a 3.26V de rango.

Respuesta: promedio, calibrado en rms

4. Corriente DC Rango Resolución Precisión Voltaje de carga

326µA 0.1µA ± 1.2% (rdg ± 3 digitos) 0.5mV / µA

3260µA 1µA ± 1.2% (rdg ± 3 digitos) 0.5mV / µA

32.6mA 10µA ± 1.2% (rdg ± 3 digitos) 8.0mV / mA

326mA 0.1mA ± 1.2% (rdg ± 3 digitos) 8.0mV / mA

10A 10mA ± 4.0% (rdg ± 3 digitos) 0.02V / A

Protección de sobrecarga: fusible F 300mA para los rangos µA y mA.

5. Corriente AC Rango Resolución Precisión Voltaje de carga

326µA 0.1µA ± 1.5% (rdg ± 5 digitos) 0.5mV / µA

3260µA 1µA ± 1.8% (rdg ± 5 dígitos) 0.5mV / µA

32.6mA 10µA ± 1.8% (rdg ± 5 dígitos) 8.0mV / mA

326mA 0.1mA ± 2.0% (rdg ± 5 dígitos) 8.0mV / mA

10A 10mA ± 5.0% (rdg ± 7 dígitos) 0.02V / A

Protección de sobrecarga: fusible F 300mA para los rangos µA y mA.

Rango de frecuencia: 40 a 400 Hz

Respuesta: promedio, calibrado en rms en ondas senoidales.

Page 15: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

6. Resistencia Rango Resolución Precisión

326Ω 0.1Ω ± 1.0% (rdg ± 3 dígitos)

3.26kΩ 1Ω ± 1.0% (rdg ± 1 dígitos)

32.6 kΩ 10Ω ± 1.0% (rdg ± 1 dígitos)

326 kΩ 100Ω ± 1.0% (rdg ± 1 dígitos)

3.26MΩ 1kΩ ± 1.0% (rdg ± 1 dígitos)

32.6MΩ 10kΩ ± 2.0% (rdg ± 2 dígitos)

Máximo voltaje del circuito abierto: 1.3V

7. Condensadores Rango Resolución Precisión

326nF 0.1nF ± 5.0% (rdg ± 10 dígitos)

32.6µF 10nF ± 5.0% (rdg ± 10 dígitos)

8. Frecuencia Rango Resolución Precisión

32.6kHz 10Hz ± 1.5% (rdg ± 10 dígitos)

150kHz 100Hz ± 3.0% (rdg ± 10 dígitos)

Sensibilidad: 500mV rms hasta 50kHz, 1V rms para 50kHz a 150kHz.

BATERÍA Y CAMBIO DE FUSIBLE Si el símbolo aparece en la pantalla LCD, esto indica que la batería deberá

reemplazarse. Quitar los tornillos de la tapa de la batería y abrirla. Reemplazar la batería por

otra nueva.

El fusible raramente necesita ser reemplazado y casi siempre suele ser un error del multimetro.

Abrir la tapa y coger el PCB. Reemplazar el fusible fundido según el rango especificado.

Atención: Antes de abrir la tapa, estar seguros de que el cable esté desconectado del circuito

de medida para evitar problemas eléctricos.

Para protecciones contra el fuego, reemplazar los fusibles solo con los rangos especificados:

F1: F 300mA/250V.

Page 16: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

INSTRUCCIONES DE USO 1. Medida del voltaje

• Conectar el cable negro a la entrada COM y el cable rojo a la entrada V / Ω / F.

• Seleccionar la función V V ~ y conectar el cable a través de la fuente o debajo de la

medida de carga.

• Leer en la pantalla LCD. La polaridad de la conexión roja debe estar indicada para

hacer mediciones DC.

2. Medida de corriente • Conectar el cable negro a la entrada COM y el cable rojo a la entrada mA/Cx para un

máximo de 300mA. Para un máximo de 10A, mover el cable rojo a la entrada A.

• Elegir la función de rango µA, mA o A y pulsar el botón / ~ para seleccionar el modo

de medida DCA o ACA.

• Conectar los cables en serie para medir la corriente.

• Leer en la pantalla LCD. La polaridad de la conexión roja debe estar indicada para

hacer mediciones DC.

3. Medida de resistencia • Conectar el cable negro a la entrada COM y el cable rojo a la entrada V / Ω / F (NOTA:

La polaridad de la conexión es positiva “+”)

• Elegir la función Ω y conectar los cables a la resistencia. NOTA:

• Para resistencia de 3.26MΩ, el multimetro debe tomarse unos pocos segundos para

estabilizar la lectura. Esto es normal para medida de altas resistencias. • Cuando la entrada no está conectada, p.e., abrir el circuito, la figura “OL” debe

visualizarse para condiciones de sobrecarga. • Cuando se chequea la resistencia de los circuitos, estar seguro de que el circuito está

desconectado, además de todos los condensadores están descargados.

Page 17: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

8. Medida de la capacidad de los condensadores

• Conectar el cable negro a la entrada COM y el rojo a la entrada mA/Cx. (NOTA: La

polaridad de la conexión es positiva “+”)

• Elegir la función de la posición nF o µF. • Conectar los cables alrededor del condensador y estar seguro de que la polaridad de la

conexión se visualiza. NOTA:

• Cuando se chequea la capacidad de los condensadores del circuito, estar seguros de

que todos los componentes del circuito están quitados y todos los condensadores

descargados.

• El modo de control de rango en medida de condensadores es manual y solo está

provisto de dos rangos (326nF, 32.6µF).

• Si el botón de control de rangos está siendo utilizado en esta función de medida, los

puntos decimales estarán en posición incorrecta.

• En el rango nF, cuando el condensador a medir no está conectado a los cables, la

pantalla no debe mostrar cero. Dicho dato tiene que ser restado de los resultados

medidos.

9. Medida de frecuencia • Conectar el cable negro a la entrada COM y el cable rojo a la entrada V / Ω / F.

• Elegir la function kHz y conectar los cables alrededor de la carga. NOTA:

• El voltaje de entrada debería estar entre 200mV y 10V rms AC. Si el voltaje está más

de 10V rms, la lectura estará fuera de sus límites.

10. Continuidad y test de diodo

• Conectar el cable negro a la entrada COM y el cable rojo a la entrada V / Ω / F (NOTA:

La polaridad de la conexión es positiva “+”) • Elegir la función y pulsar el botón para seleccionar la continuidad o el

modo test de diodo.

• Para comprobar la continuidad, si la continuidad existe (p.e., resistencia menor a 50 Ω),

el timbre deberá sonar.

• Si el modo de test de diodo está seleccionado, conectar el cable rojo y el negro al

cátodo y ánodo del diodo. El voltaje irá disminuyendo, y deberá visualizarse en

pantalla.

Page 18: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

11. Test de transistor • Elegir la función hFE.

• Aunque el transistor sea de tipo NPN o PNP, localizar el emisor, base y colector.

Insertar los cables del transistor para chequear los agujeros adecuados del frontal del

panel.

• La pantalla LCD deberá visualizar el valor aproximado en hFE de la corriente base

10µA y Vce 3.2V.

PRELIMINAR

• Cuando se usa el multímetro, el usuario tiene que seguir las siguientes normas de

seguridad: o Protección contra daños de corriente eléctrica. o Protección del multímetro contra usos incorrectos.

• Los estándares de seguridad deben estar garantizados solo si se usan los cables cagados.

Si es necesario, tienen que reemplazarse por otro del mismo modelo. Los cables deben

estar en buenas condiciones.

DURANTE EL USO • Nunca exceder los valores límites de protección indicados en las especificaciones para

cada medida.

• Cuando el multímetro está unido al circuito, no tocar los terminales.

• Cuando el valor de escala a medir es desconocido, posicionar el selector de rangos en la

posición más alta.

• Antes cambiar el selector de rangos, desconectar los cables del circuito.

• Recordar siempre que amplios voltajes de corriente pueden dañar el multímetro.

• Nunca medir resistencias en circuitos en tensión.

• Nunca realizar medidas de condensadores a menos que el condensador esté descargado.

• Trabajar siempre con cuidado cuando se trabaja con voltajes alrededor de 60V DC o 30V

AC rms. Colocar los dedos por debajo de la sonda protectora mientras se mide.

Page 19: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button

MANTENIMIENTO Antes de abrir el multímetro, siempre desconectar los cables de todas las cargas eléctricas.

Para continuar la protección contra el fuego, reemplazar el fusible solo con los rangos de corriente

y voltaje especificados: F1: F 300mA/250V.

Si se observa algún defecto o algo anormal, el multímetro puede que no se deba usar más, y por

ello hay que verificarlo.

Nunca usar el multímetro a menos que la tapa de la batería esté en su sitio y fijada correctamente.

Para limpiar el multímetro, usar una trapo húmedo y un jabón suave, no usar abrasivos o

disolventes sobre el.

Page 20: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button
Page 21: DIGITAL MULTIMETER - EGA Master - Herramienta … this button to select AC or DC current measuring function when the function switch is set at µA, mA, A positions. Push this button