DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL Deutsch · PDF file • During...

Click here to load reader

  • date post

    28-Jul-2020
  • Category

    Documents

  • view

    1
  • download

    0

Embed Size (px)

Transcript of DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL Deutsch · PDF file • During...

  • DAIKIN ROOM AIR CONDITIONER

    INSTALLATION MANUAL R410A Split Series

    En gl

    is h

    D eu

    ts ch

    Fr an

    ça is

    N ed

    er la

    nd s

    Es pa

    ño l

    Ita lia

    no Eλ

    λη νι κά

    Po rt

    ug ue

    s Py

    cc ки й

    Тü rk

    çe

    Installation manual Installationsanleitung Manuel d’installation

    Installatiehandleiding Manual de instalación

    Manuale di installazione Εγχειρίδιο εγκατάστασης

    Manual de instalação Руководство по монтажу

    Montaj kılavuzları

    MODELS FVXG25K2V1B FVXG35K2V1B FVXG50K2V1B

    00_CV_3P276870-1.indd 100_CV_3P276870-1.indd 1 12/7/2010 2:54:36 PM12/7/2010 2:54:36 PM

  • U m

    ed a

    C en

    te r

    B ld

    g. , 2

    -4 -1

    2, N

    ak az

    ak i-N

    is hi

    , K

    ita -k

    u, O

    sa ka

    , 5 30

    -8 32

    3 Ja

    pa n

    D A

    IK IN

    IN D

    U S

    T R

    IE S

    , L T

    D .

    Lo w

    V ol

    ta ge

    2 00

    6/ 95

    /E C

    E le

    ct ro

    m ag

    ne tic

    C om

    pa tib

    ili ty

    2 00

    4/ 10

    8/ E

    C *

    3SB64417-15PFV X

    G 25

    K 2V

    1B , F

    V X

    G 35

    K 2V

    1B , F

    V X

    G 50

    K 2V

    1B

    S hi

    nr i S

    ad a

    M an

    ag er

    Q ua

    lit y

    C on

    tr ol

    D ep

    ar tm

    en t

    D A

    IK IN

    .T C

    F .0

    15 N

    9/ 01

    -2 01

    1

    K E

    M A

    Q u

    al it

    y B

    .V .

    74 73

    6- K

    R Q

    /E M

    C 97

    -4 95

    7

    ,

    ,

    3SB64417-15P.fm Page 1 Friday, February 4, 2011 2:52 PM

  • U m

    ed a

    C en

    te r

    B ld

    g. , 2

    -4 -1

    2, N

    ak az

    ak i-N

    is hi

    , K

    ita -k

    u, O

    sa ka

    , 5 30

    -8 32

    3 Ja

    pa n

    ,

    ,

    F V

    X G

    25 K

    2V 1B

    , F V

    X G

    35 K

    2V 1B

    , F V

    X G

    50 K

    2V 1B

    3SB64417-16L

    S hi

    nr i S

    ad a

    M an

    ag er

    Q ua

    lit y

    C on

    tr ol

    D ep

    ar tm

    en t

    3SB64417-16L.fm Page 1 Wednesday, February 16, 2011 10:51 AM

  • 3SB64417-16L.fm Page 2 Wednesday, February 16, 2011 10:51 AM

  • 1 English

    Safety Precautions The precautions described herein are classifi ed as WARNING and CAUTION. They both contain important informa-• tion regarding safety. Be sure to observe all precautions without fail. Meaning of WARNING and CAUTION notices•

    WARNING ....Failure to follow these instructions properly may result in personal injury or loss of life.

    CAUTION ..... Failure to observe these instructions properly may result in property damage or personal injury, which may be serious depending on the circumstances.

    The safety marks shown in this manual have the following meanings:•

    Be sure to follow the instructions. Be sure to establish an earth connection. Never attempt.

    After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate • the air conditioner and take care of it with the aid of the operation manual.

    WARNING Ask your dealer or qualifi ed personnel to carry out installation work.• Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fi re. Install the air conditioner in accordance with the instructions in this installation manual.• Improper installation may result in water leakage, electric shocks or fi re. Be sure to use only the specifi ed accessories and parts for installation work.• Failure to use the specifi ed parts may result in the unit falling, water leakage, electric shocks or fi re. Install the air conditioner on a foundation strong enough to withstand the weight of the unit.• A foundation of insuffi cient strength may result in the equipment falling and causing injury. Electrical work must be performed in accordance with relevant local and national regulations and with instructions • in this installation manual. Be sure to use a dedicated power supply circuit only. Insuffi ciency of power circuit capacity and improper workmanship may result in electric shocks or fi re. Use a cable of suitable length.• Do not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fi re. Make sure that all wiring is secured, the specifi ed wires are used, and that there is no strain on the terminal con-• nections or wires. Improper connections or securing of wires may result in abnormal heat build-up or fi re. When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires • so that the control box lid can be securely fastened. Improper positioning of the control box lid may result in electric shocks, fi re or over heating terminals.

    • If refrigerant gas leaks during installation, ventilate the area immediately. Toxic gas may be produced if the refrigerant comes into contact with fi re.

    • After completing installation, check for refrigerant gas leakage. Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fi re, such as a fan heater, stove or cooker. When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air, • and use only the specifi ed refrigerant (R410A). The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and even injury. During installation, attach the refrigerant piping securely before running the compressor.• If the refrigerant pipes are not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal pres- sure in the refrigeration cycle, which may result in equipment damage and even injury. During pump-down, stop the compressor before removing the refrigerant piping.• If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed, causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury.

    • Be sure to earth the air conditioner. Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks. Be sure to install an earth leakage breaker.• Failure to install an earth leakage breaker may result in electric shocks or fi re.

    CAUTION • Do not install the air conditioner at any place where there is a danger of fl ammable gas leakage.

    In the event of a gas leakage, build-up of gas near the air conditioner may cause a fi re to break out. While following the instructions in this installation manual, install drain piping to ensure proper drainage and insu-• late piping to prevent condensation. Improper drain piping may result in indoor water leakage and property damage. Tighten the fl are nut according to the specifi ed method such as with a torque wrench.• If the fl are nut is too tight, it may crack after prolonged use, causing refrigerant leakage.

    01_EN_3P276870-1.indb 101_EN_3P276870-1.indb 1 2/23/2011 5:03:50 PM2/23/2011 5:03:50 PM

  • English 2

    En gl

    is hAccessories

    Indoor unit A – K

    A Mounting plate

    1

    E Wireless remote controller

    1

    J Operation manual

    1

    B Titanium apatite photocata- lytic air-purifying fi lter

    2

    F Remote controller holder

    1

    K Installation manual

    1

    C Drain hose

    1

    G Dry battery AAA. LR03 (alka- line)

    2

    D Insulation sheet (1)

    2

    H Insulation sheet (2)

    1

    Choosing an Installation Site Before choosing the installation site, obtain user approval.•

    Indoor unit1. The indoor unit should be sited in a place where:•

    the restrictions on installation specifi ed in the indoor unit installation drawings are met,1) both air inlet and air outlet have clear paths met,2) the unit is not in the path of direct sunlight,3) the unit is away from the source of heat or steam,4) there is no source of machine oil vapour (this may shorten indoor unit life),5) cool (warm) air is circulated throughout the room,6) the unit is away from electronic ignition type fl uorescent lamps (inverter or rapid start type) as they may shorten the 7) remote controller range, the unit is at least 1m away from any television or radio set (unit may cause interference with the picture or sound),8) no laundry equipment is located,9) there is a wall that can bear the weight of the indoor unit adequately.10)

    Wireless remote controller2. Turn on all the fl uorescent lamps in the room, if any, and fi nd the site where remote controller signals are properly • received by the indoor unit (within 7m).

    01_EN_3P276870-1.indb 201_EN_3P276870-1.indb 2 2/23/2011 5:03:51 PM2/23/2011 5: