MODELS
FTXS35K2V1BFTXS42K2V1BFTXS50K2V1B
DAIKIN ROOM AIR CONDITIONER
INSTALLATION MANUALR410A Split Series
Installation manualInstallationsanleitungManuel dinstallation
InstallatiehandleidingManual de instalación
Manuale dinstallazioneΕγχειρίδιο εγκατάστασης
Manual de instalaçãoРуководство по монтажу
Montaj kılavuzları
Manuel dinstallation
Manuale dinstallazione
00_CV_3P320971-1A.indd 1 11/1/2012 1:49:14 PM
Um
eda
Cen
ter
Bld
g., 2
-4-1
2, N
akaz
aki-N
ishi
,K
ita-k
u, O
saka
, 530
-832
3 Ja
pan
DA
IKIN
IND
US
TR
IES
, LT
D.
EN
6033
5-2-
40,
,
,
DA
IKIN
.TC
F.01
5 P
9/09
-201
2
DEKR
A Ce
rtific
atio
n B.
V. (N
B034
4)
7473
6-K
RQ
/EM
C97
-495
7
3SB65451-17F
Shi
nri S
ada
Man
ager
Qua
lity
Con
trol
Dep
artm
ent
FT
XS
35K
2V1B
, FT
XS
42K
2V1B
, FT
XS
50K
2V1B
Mac
hine
ry 2
006/
42/E
C *
*E
lect
rom
agne
tic C
ompa
tibili
ty 2
004/
108/
EC
*
Low
Vol
tage
200
6/95
/EC
3SB65451-17F.fm Page 1 Tuesday, October 16, 2012 5:25 PM
3SB65451-4.fm Page 2 Thursday, October 27, 2011 4:49 PM
1 ■English
Safety Precautions•TheprecautionsdescribedhereinareclassifiedasWARNINGandCAUTION.Theybothcontainimportantinforma-tionregardingsafety.Besuretoobserveallprecautionswithoutfail.
•MeaningofWARNINGandCAUTIONnotices
WARNING ........Failure to follow these instructions properly may result in personal injury or loss of life.
CAUTION .........Failure to observe these instructions properly may result in property damage or personal injury, which may be serious depending on the circumstances.
•Thesafetymarksshowninthismanualhavethefollowingmeanings:
Besuretofollowtheinstructions. Besuretoestablishanearthconnection. Neverattempt.
•Aftercompletinginstallation,conductatrialoperationtocheckforfaultsandexplaintothecustomerhowtooperatetheairconditionerandtakecareofitwiththeaidoftheoperationmanual.
WARNING•Askyourdealerorqualifiedpersonneltocarryoutinstallationwork.Donotattempttoinstalltheairconditioneryourself.Improperinstallationmayresultinwaterleakage,electricshocksorfire.
•Installtheairconditionerinaccordancewiththeinstructionsinthisinstallationmanual.Improperinstallationmayresultinwaterleakage,electricshocksorfire.
•Besuretouseonlythespecifiedaccessoriesandpartsforinstallationwork.Failuretousethespecifiedpartsmayresultintheunitfalling,waterleakage,electricshocksorfire.
•Installtheairconditioneronafoundationstrongenoughtowithstandtheweightoftheunit.Afoundationofinsufficientstrengthmayresultintheequipmentfallingandcausinginjury.
•Electricalworkmustbeperformedinaccordancewithrelevantlocalandnationalregulationsandwithinstructionsinthisinstallationmanual.Besuretouseadedicatedpowersupplycircuitonly.Insufficiencyofpowercircuitcapacityandimproperworkmanshipmayresultinelectricshocksorfire.
•Useacableofsuitablelength.Donotusetappedwiresoranextensionlead,asthismaycauseoverheating,electricshocksorfire.
•Makesurethatallwiringissecured,thespecifiedwiresareused,andthatthereisnostrainontheterminalconnectionsorwires.Improperconnectionsorsecuringofwiresmayresultinabnormalheatbuild-uporfire.
•Whenwiringthepowersupplyandconnectingthewiringbetweentheindoorandoutdoorunits,positionthewiressothatthecontrolboxlidcanbesecurelyfastened.Improperpositioningofthecontrolboxlidmayresultinelectricshocks,fireoroverheatingterminals.
•Ifrefrigerantgasleaksduringinstallation,ventilatetheareaimmediately.Toxicgasmaybeproducediftherefrigerantcomesintocontactwithfire.
•Aftercompletinginstallation,checkforrefrigerantgasleakage.Toxicgasmaybeproducediftherefrigerantgasleaksintotheroomandcomesintocontactwithasourceoffire,suchasafanheater,stoveorcooker.
•Wheninstallingorrelocatingtheairconditioner,besuretobleedtherefrigerantcircuittoensureitisfreeofair,anduseonlythespecifiedrefrigerant(R410A).Thepresenceofairorotherforeignmatterintherefrigerantcircuitcausesabnormalpressurerise,whichmayresultinequipmentdamageandeveninjury.
•Duringinstallation,attachtherefrigerantpipingsecurelybeforerunningthecompressor.Iftherefrigerantpipesarenotattachedandthestopvalveisopenwhenthecompressorisrun,airwillbesuckedin,causingabnormalpressureintherefrigerationcycle,whichmayresultinequipmentdamageandeveninjury.
•Duringpump-down,stopthecompressorbeforeremovingtherefrigerantpiping.Ifthecompressorisstillrunningandthestopvalveisopenduringpump-down,airwillbesuckedinwhentherefrigerantpipingisremoved,causingabnormalpressureintherefrigerationcycle,whichmayresultinequipmentdamageandeveninjury.
•Besuretoearththeairconditioner.Donotearththeunittoautilitypipe,lightningconductorortelephoneearthlead.Imperfectearthingmayresultinelectricshocks.
•Besuretoinstallanearthleakagebreaker.Failuretoinstallanearthleakagebreakermayresultinelectricshocksorfire.
CAUTION•Donotinstalltheairconditioneratanyplacewherethereisadangerofflammablegasleakage.Intheeventofagasleakage,build-upofgasneartheairconditionermaycauseafiretobreakout.
•Whilefollowingtheinstructionsinthisinstallationmanual,installdrainpipingtoensureproperdrainageandinsulatepipingtopreventcondensation.Improperdrainpipingmayresultinindoorwaterleakageandpropertydamage.
•Tightentheflarenutaccordingtothespecifiedmethodsuchaswithatorquewrench.Iftheflarenutistootight,itmaycrackafterprolongeduse,causingrefrigerantleakage.
01_EN_3P320971-1A.indd 1 11/1/2012 4:44:15 PM
Eng
lish
■English 2
AccessoriesIndoor unit A – H ,
Mountingplate 1 Remotecontrollerholder 1 Operationmanual 1
Titaniumapatitephotocatalyticair-purifyingfilter
2 DrybatteryAAA.LR03
(alkaline)2 Installationmanual 1
Wirelessremotecontroller 1 Indoorunitfixingscrew
(M4×12L)2
Choosing an Installation Site•Beforechoosingtheinstallationsite,obtainuserapproval.
1. Indoor unit•Theindoorunitshouldbesitedinaplacewhere:1)therestrictionsoninstallationspecifiedintheindoorunitinstallationdrawingsaremet,2)bothairinletandairoutlethaveclearpathsmet,3)theunitisnotinthepathofdirectsunlight,4)theunitisawayfromthesourceofheatorsteam,5)thereisnosourceofmachineoilvapour(thismayshortenindoorunitlife),6)cool(warm)airiscirculatedthroughouttheroom,7)theunitisawayfromelectronicignitiontypefluorescentlamps(inverterorrapidstarttype)astheymayshortenthe
remotecontrollerrange,8)theunitisatleast1mawayfromanytelevisionorradioset(unitmaycauseinterferencewiththepictureorsound),9)nolaundryequipmentislocated.
2. Wireless remote controller•Turnonallthefluorescentlampsintheroom,ifany,andfindthesitewhereremotecontrollersignalsareproperlyreceivedbytheindoorunit(within7m).
A D G
B EH
CF
01_EN_3P320971-1A.indd 2 11/1/2012 4:44:15 PM
3 ■English
Preparation before Installation1. Removing and installing the front panel
•Removal method1)Placeyourfingersintheindentationsonthemainunit(oneeachonthe
leftandrightsides),andopenthefrontpaneluntilitstops.2)Continuetoopenthefrontpanelfurtherwhileslidingthepaneltothe
rightandpullingittowardyouinordertodisengagethefrontpanelshaftontheleftside.Todisengagethefrontpanelshaftontherightside,slidethepaneltotheleftwhilepullingittowardyou.
•Installation methodAlignthetabsofthefrontpanelwiththegrooves,andpushallthewayin.Thencloseslowly.Pushthecentreofthelowersurfacepanelfirmlytoengagethetabs.
Front panel shaft
Groove
2. Removing and installing the front grille•Removal method1)Removethefrontpaneltoremovetheairfilter.2)Removethe3screwsfromthefrontgrille.3)Infrontofthe markofthefrontgrille,thereare3upperhooks.
Lightlypullthefrontgrilletowardyouwithonehand,andpushdownonthehookswiththefingersofyourotherhand.
Upper hook mark area(3 locations)
Pushdown.
Upper hook
When there is no work space because the unit is close to ceiling
CAUTION•Besuretowearprotectiongloves.
Placebothhandsunderthecentreofthefrontgrille,andwhilepushingup,pullittowardyou.•Installation method1)Installthefrontgrilleandfirmlyengagetheupperhooks(3locations).2)Install3screwsofthefrontgrille.3)Installtheairfilterandthenmountthefrontpanel.
1) Push up.
2) Pull toward you.
3. How to set the different addressesWhentwoindoorunitsareinstalledinoneroom,thetwowirelessremotecontrollerscanbesetfordifferentaddresses.1)Removethemetalplateelectricalwiringcover.
(RefertotheRemoval/attachment methods of metal plate electrical wiring covers.)
2)Cuttheaddressjumper(JA)ontheprintedcircuitboard.3)Cuttheaddressjumper(J4)intheremotecontroller.
•Becarefulnottocutjumper(J8).
ADDRESS
JA
ADDRESSJAEXIST 1CUT 2
Jumper
ADDRESSJ4EXISTCUT
12
(J8) (J4)
01_EN_3P320971-1A.indd 3 11/1/2012 4:44:17 PM
Eng
lish
■English 4
Indoor Unit Installation Drawings
Screws(M4 × 16L)
Service lid
Caulk pipe hole gap with putty.
Wrap the insulation pipe with the finishing tape from bottom to top.
Cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipe’s cut line.
Bottom frameFront grille
■ How to attach the indoor unitHook the claws of the bottom frame to the mounting plate.If the claws are difficult to hook, remove the front grille.
■ How to remove the indoor unitPush up the lower part of the front grille to release the claws. If they are difficult to release, remove the front grille.
■ Opening the service lidThe service lid is opening/closing type.
■ Opening method1) Remove the service lid screw.2) Pull out the service lid diagonally
down in the direction of the arrow.3) Pull down.
The mounting plate should be installed on a wall which can support the weight of the indoor unit.
30mm or more from ceiling
Front panel
50mm or more from walls (on both sides)
Air filters
A Mounting plate
A Mounting plate
Mounting plate fixing screw (field supply: M4 × 25L)
C Wireless remote controller
Fixing screw for remote controller holder (field supply: M3 × 20L)
D Remote controller holder
Air filter
Titanium apatite photocatalytic air-purifying filter
Filter frame
Tab
Titanium apatite photocatalytic air-purifying filter (2 pcs)
Before screwing the remote controller holder to the wall, make sure that control signals are properly received by indoor unit.
Claw
B
01_EN_3P320971-1A.indd 4 11/1/2012 4:44:18 PM
5 ■English
Indoor Unit Installation1. Installing the mounting plate
•Themountingplateshouldbeinstalledonawallwhichcansupporttheweightoftheindoorunit.1)Temporarilysecurethemountingplatetothewall,makesurethatthepaneliscompletelylevel,andmarktheboring
pointsonthewall.2)Securethemountingplatetothewallwithscrews.
Recommended mounting plate retention spots and dimensions
209 241 191.5
66 106176150
384
900
344
75.5
4825
0
4829
8
50
50
Use tape measure as shown.
unit: mm
Removed pipe port cover
Recommended mounting plate retention spots (5 spots in all)
Place a leveler on raised tab.
Drain hose positionKeep here the piece cut out from the unit for piping
Liquid pipe end Gas pipe end
A Mounting plate
* The removed pipe port cover can be kept in the mounting plate pocket.
Position the end of a tape measure at .
Through-the-wall hole ϕ65mm
2. Boring a wall hole and installing wall embedded pipe•Forwallscontainingmetalframeormetalboard,besuretouseawallembeddedpipeandwallcoverinthefeed-throughholetopreventpossibleheat,electricalshock,orfire.
•Besuretocaulkthegapsaroundthepipeswithcaulkingmaterialtopreventwaterleakage.1)Boreafeed-throughholeof65mminthewallsoithasadownslopetowardtheoutside.2)Insertawallpipeintothehole.3)Insertawallcoverintowallpipe.4)Aftercompletingrefrigerantpiping,wiring,anddrainpiping,caulkpipe
holegapwithputty.
Inside Outside
Caulking
Wall embedded pipe (field supply)
Wall hole cover(field supply)
Wall embedded pipe (field supply)
ϕ65
3. Installing the indoor unit•Inthecaseofbendingorcuringrefrigerantpipes,keepthefollowingprecautionsinmind.Abnormalsoundmaybegeneratedifimproperworkisconducted.1)Donotstronglypresstherefrigerantpipesontothebottomframe.2)Donotstronglypresstherefrigerantpipesonthefrontgrille,either. 1)
2)
01_EN_3P320971-1A.indd 5 11/1/2012 4:44:19 PM
Eng
lish
■English 6
•Removethepipeportcoverasshownbelow.1)Cutoffthepipeportcoverfrominsidethefrontgrilleusingacopping
saw.Applythebladeofthecoppingsawtothenotch,andcutoffthepipeportcoveralongtheuneveninnersurface.
2)Aftercuttingoffthepipeportcover,performfiling.Removetheburrsalongthecutsectionusingahalfroundneedlefile.
CAUTION•Ifthepipeportcoveriscutoffusingnippers,thefrontgrillewillbedamaged.Pleasedonotusenippers.•Wearglovesduringthepipeportcoverremoval.
3-1. Right-side, right-back, or right-bottom piping1)Attachthedrainhosetotheundersideoftherefrigerantpipeswith
adhesivevinyltape.2)Wraptherefrigerantpipesanddrainhosetogetherwithinsulation
tape.Right-bottom piping
Right-back piping
Right-side piping
Bind refrigerant pipe and drain hose together with insulating tape.
Remove pipe port cover here for right-side piping.
Remove pipe port cover here for right-bottom piping.
3)Passthedrainhoseandrefrigerantpipesthroughthewallhole,thensettheindoorunitonthemountingplatehooksbyusingthemarkingsatthetopoftheindoorunitasaguide.
Mounting plateA
4)Openthefrontpanel,thenopentheservicelid.(Refertopreparationbeforeinstallation.)
5)Passtheinter-unitwirefromtheoutdoorunitthroughthefeed-throughwallholeandthenthroughthebackoftheindoorunit.Pullthemthroughthefrontside.Bendtheendsoftiewiresupwardforeasierworkinadvance.(Iftheinter-unitwireendsaretobestrippedfirst,bundlewireendswithadhesivetape.)
6)Pressthebottomframeoftheindoorunitwithbothhandstosetitonthemountingplatehooks.Makesurethewiresdonotcatchontheedgeoftheindoorunit.
Wire guide
When stripping the ends of inter-unit wire in advance, bind right ends of wires with insulating tape.
Hang indoor unit’s hook here.
Inter-unit wire
Mounting plateA
01_EN_3P320971-1A.indd 6 11/1/2012 4:44:20 PM
7 ■English
Indoor Unit Installation3-2. Left-side, left-back, or left-bottom piping
How to replace the drain plug and drain hose•Replacing onto the left side1)Removetheinsulationfixingscrewontheright
andremovethedrainhose.2)Removethedrainplugontheleftsideand
attachittotherightside.3)Insertthedrainhoseandtightenwithincluded
insulationfixingscrew.*(Forgettingtotightenthismaycausewaterleakages.)
Drain hose attachment position* The drain hose is on the back of the unit.
Front side of unit
Attachment on the right side (factory default)Attachment on the left side
Drain hose Drain hose
Insulation fixing screw
Insulation fixing screw
Right sideLeft side
1)Attachthedrainhosetotheundersideoftherefrigerantpipeswithadhesivevinyltape.
Remove pipe port cover here for left-bottom piping.
Remove pipe port cover here for left-side piping.
Left-bottom piping
Left-side piping
Left-back piping
2)Besuretoconnectthedrainhosetothedrainportinplaceofadrainplug.
How to set drain plug
No gap.Do not apply lubricating oil (refrigeration oil) when inserting.Application of causes deterioration and drain leakage of the plug.
Insert a hexagonal wrench (4mm).
3)Shapetherefrigerantpipesalongthepipepathmarkingonthemountingplate.
4)Passdrainhoseandrefrigerantpipesthroughthewallhole,thensettheindoorunitonmountingplatehooks,usingthe markingsatthetopofindoorunitasaguide.
5)Pullintheinter-unitwire.6)Connecttheinter-unitpipes.
Drain hose
Caulk this hole with putty or caulking material. Bind with adhesive
vinyl tape.
A Mounting plate
Wrap insulating tape around the bent portion of refrigerant pipes. Overlap at least half the width of the tape with each turn.
7)Wraptherefrigerantpipesanddrainhosetogetherwithinsulationtapeasrightfigure,incaseofsettingthedrainhosethroughthebackoftheindoorunit.
8)Whileexercisingcaresothattheinter-unitwiredonotcatchindoorunit,pressthebottomedgeofindoorunitwithbothhandsuntilitisfirmlycaughtbythemountingplatehooks.Secureindoorunittothemountingplatewithindoorunitfixingscrews(M4×12L).
Refrigerantpipes
Drain hose
Bottom frame
F Indoor unit fixing screw (M4 × 12L) (2 locations)
Mountingplate
AInter-unit wire
3-3. Wall embedded pipingFollowtheinstructionsgivenunderleft-side,left-back,orleft-bottompiping.1)Insertthedrainhosetothisdepthsoitwon’tbepulledoutofthedrain
pipe.
Inner wall
Vinyl chloride drain pipe (VP-30)
Drain hose50mm or more
Insert drain hose to this depth so it won’t be pulled out of drain pipe.
Outer wall
01_EN_3P320971-1A.indd 7 11/1/2012 4:44:21 PM
Eng
lish
■English 8
4. Wiring1)Stripwireends(15mm).2)Matchwirecolourswithterminalnumbersonindoorandoutdoorunit’sterminalblocksandfirmlyscrewwirestothe
correspondingterminals.3)Connecttheearthwirestothecorrespondingterminals.4)Pullwirestomakesurethattheyaresecurelylatchedup,thenretainwireswithwireretainer.5)Shapethewiressothattheservicelidfitssecurely,thencloseservicelid.
Terminal block
Electrical component box
Wire retainer
1 2 3
Use the specified wire type.
Shape wires so that the service lid will fit securely.
Firmly secure wire retainer so that wires sustain no external stress.
123
1 2 3 L NInter-unit wire4-core 1.5mm² or moreH05RN
Firmly fix the wires with the terminal screws.
Outdoor unit
Indoor unit
Firmly fix the wires with the terminal screws.
WARNING•Donotusetappedwires,strandedwires,extensioncords,orstarburstconnections,astheymaycauseoverheating,electricalshock,orfire.
•Donotuselocallypurchasedelectricalpartsinsidetheproduct.(Donotbranchthepowerforthedrainpump,etc.,fromtheterminalblock.)Doingsomaycauseelectricshockorfire.
•Donotconnectthepowerwiretotheindoorunit.Doingsomaycauseelectricshockorfire.
5. When connecting to an HA system. (Wired remote controller, central remote controller etc.)1)Removethemetalplateelectrical
wiringcover.(RefertotheRemoval/attach-ment methods of metal plate electrical wiring covers.)
2)Snapofftheclaw.3)Attachtheconnectioncordtothe
S21connectorandpulltheharnessoutthroughthenotchedpartinthefigure.
4)Replacetheelectricalwiringcoverasitwas,andpulltheharnessaround,asshowninthefigure.
HA connector(S21)
HA connector(S21)
Lay the HA cord as shown in the figure.
Claw
01_EN_3P320971-1A.indd 8 11/1/2012 4:44:23 PM
9 ■English
Indoor Unit Installation•Removal methods of metal plate electrical wiring covers1)Removethefrontgrille.2)Removetheelectricalwiringbox.(1screw)3)Raisethe2upperpartsofthemetalplateelectricalwiringcover,pullthepartsfrontward,andremovethe3tabs.4)Slidethemetalplateelectricalwiringcoverupwardandremovethe2tabsonthelowerside.
3) Raise the 2 upper parts of the metal plate electrical wiring cover, pull the parts frontward, and remove the 3 tabs.
4) Slide the metal plate electrical wiring cover upward and remove the 2 tabs on the lower side.
Pull
Pull
Slide
Pull
Tab
Screw
2) Remove the electrical wiring box. (1 screw)
Tab
Slide
Slide
•Attachment methods of metal plate electrical wiring coversAttachthemetalplateelectricalwiringcoversasshownbelow.1)Leanthemetalplateelectricalwiringcoverasshowninthefigureandattachtab(1)onthelowersidetotheelectrical
wiringbox.2)Attachtab(2)onthelowersideofthemetalplateelectricalwiringcover.
Tab (2)
Tab (1)
Tab (1)
3)Pushintheupperpartofthemetalplateelectricalwiringcoverandattachthe3tabs.
Tab
01_EN_3P320971-1A.indd 9 11/1/2012 4:44:26 PM
Eng
lish
■English 10
6. Drain piping1)Connectthedrainhose,asdescribedright.
The drain hose should be inclined downward.
No trap is permitted.
Do not put the end of the hose in water.
2)Removetheairfiltersandpoursomewaterintothedrainpantocheckthewaterflowssmoothly.
3)Ifdrainhoseextensionorembeddeddrainpipingisrequired,useappropriatepartsthatmatchthehosefrontend.
[Figureofhosefrontend]
ϕ16
ϕ18
4)Whenextendingthedrainhose,useacommerciallyavailableextensionhosewithaninnerdiameterof16mm.Besuretothermallyinsulatetheindoorsectionoftheextensionhose.
Indoor unit drain hose
Extension drain hose
Heat insulation tube(field supply)
ϕ16
ϕ16
Drain hose supplied with the indoor unit
5)Whenconnectingarigidpolyvinylchloridepipe(nominaldiameter13mm)directlytothedrainhoseattachedtotheindoorunitaswithembed-dedpipingwork,useanycommerciallyavailabledrainsocket(nominaldiameter13mm)asajoint.
Commercially available drain socket (nominal diameter 13mm)
Commercially available rigid polyvinyl chloride pipe(nominal diameter 13mm)
Drain hose supplied with the indoor unit
ϕ18
Refrigerant Piping Work1. Flaring the pipe end
1)Cutthepipeendwithapipecutter.2)Removeburrswiththecutsurfacefacingdownward
sothatthechipsdonotenterthepipe.3)Puttheflarenutonthepipe.4)Flarethepipe.5)Checkthattheflaringisproperlymade.
Set exactly at the position shown below.
A
Flaring
Die A 0-0.5mm
Clutch-type
Flare tool for R410A
1.0-1.5mm
Clutch-type (Rigid-type)
1.5-2.0mm
Wing-nut type (Imperial-type)
Conventional flare tool
(Cut exactly at right angles.) Remove burrs.
CheckFlare’s inner surface must be flaw-free.
The pipe end must be evenly flared in a perfect circle.
Make sure that the flare nut is fitted.
WARNING•Donotusemineraloilonflaredpart.•Preventmineraloilfromgettingintothesystemasthiswouldreducethelifetimeoftheunits.•Neverusepipingwhichhasbeenusedforpreviousinstallations.Onlyusepartswhicharedeliveredwiththeunit.•DoneverinstalladriertothisR410Aunitinordertoguaranteeitslifetime.•Thedryingmaterialmaydissolveanddamagethesystem.•Incompleteflaringmaycauserefrigerantgasleakage.
01_EN_3P320971-1A.indd 10 11/1/2012 4:44:27 PM
11 ■English
Refrigerant Piping Work2. Refrigerant piping
CAUTION•Usetheflarenutfixedtothemainunit.(Topreventcrackingoftheflarenutbyageddeterioration.)•Topreventgasleakage,applyrefrigerationoilonlytotheinnersurfaceoftheflare.(UserefrigerationoilforR410A.)•Usetorquewrencheswhentighteningtheflarenutstopreventdamagetotheflarenutsandgasleakage.
Alignthecentresofbothflaresandtightentheflarenuts3or4turnsbyhand.Thentightenthemfullywiththetorquewrenches.
Do not apply refrigeration
oil to the outer surface.
Flare nut
Apply refrigeration oil to
the inner surface of the
flare.
Do not apply refrigeration oil to
the flare nut to avoid tightening
with excessive torque.
[Apply oil]
Torque wrench
Piping union
Flare nut
Spanner
[Tighten]
Flare nut tightening torqueGas side Liquid side
3/8 inch1/4 inch
35, 42 class
32.7-39.9N • m(330-407kgf • cm)
1/2 inch50 class
49.5-60.3N • m(505-615kgf • cm)
14.2-17.2N • m(144-175kgf • cm)
2-1. Caution on piping handling1)Protecttheopenendofthepipeagainstdustandmoisture.2)Allpipebendsshouldbeasgentleaspossible.Useapipebender
forbending.
Wall
If no flare cap is available, cover the flare mouth with tape to keep dirt or water out.
Be sure to place a cap.
Rain
2-2. Selection of copper and heat insulation materials•Whenusingcommercialcopperpipesandfittings,observethefollowing:1)Insulationmaterial:Polyethylenefoam
Heattransferrate:0.041to0.052W/mK(0.035to0.045kcal/mh°C)Refrigerantgaspipe’ssurfacetemperaturereaches110°Cmax.Chooseheatinsulationmaterialsthatwillwithstandthistemperature.
2)Besuretoinsulateboththegasandliquidpipingandtoprovideinsulationdimensionsasbelow.
Gas pipeLiquid pipe
Gas pipe insulation
Liquid pipe insulation
Finishing tape Drain hose
Inter-unit wire
Gasside LiquidsideGaspipethermal
insulationLiquidpipethermal
insulation35,42class 50class
O.D.6.4mm I.D.12-15mm I.D.8-10mmO.D.9.5mm O.D.12.7mm
Minimumbendradius Thickness10mmMin.30mmormore
Thickness0.8mm(C1220T-O)
3)Useseparatethermalinsulationpipesforgasandliquidrefrigerantpipes.
01_EN_3P320971-1A.indd 11 11/1/2012 4:44:28 PM
Eng
lish
■English 12
Trial Operation and Testing1. Trial operation and testing
1-1 Measurethesupplyvoltageandmakesurethatitfallsinthespecifiedrange.
1-2 Trialoperationshouldbecarriedoutineithercoolingorheatingmode.
•Incoolingmode,selectthelowestprogrammabletemperature;inheatingmode,selectthehighestprogrammabletemperature.1)Trialoperationmaybedisabledineithermodedependingontheroomtemperature.
Usetheremotecontrollerfortrialoperationasdescribedbelow.2)Aftertrialoperationiscomplete,setthetemperaturetoanormallevel(26°Cto28°Cincoolingmode,20°Cto24°Cin
heatingmode).3)Forprotection,thesystemdisablesrestartoperationfor3minutesafteritisturnedoff.
1-3 Carryoutthetestoperationinaccordancewiththeoperationmanualtoensurethatallfunctionsandparts,suchaslouvermovement,areworkingproperly.•Theairconditionerrequiresasmallamountofpowerinitsstandbymode.Ifthesystemisnottobeusedforsometimeafterinstallation,shutoffthecircuitbreakertoeliminateunnecessarypowerconsumption.
•Ifthecircuitbreakertripstoshutoffthepowertotheairconditioner,thesystemwillrestoretheoriginaloperationmodewhenthecircuitbreakerisopenedagain.
Trial operation from remote controller1) Press“ON/OFF”buttontoturnonthesystem.2) Press“TEMP”button(2locations)and“MODE”buttonatthesametime.3) Press“TEMP”buttonandselect“T”.4) Press“MODE”button.5) Trialoperationterminatesinapprox.30minutesandswitchesintonormalmode.Toquitatrialoperation,press
“ON/OFF”button.
2. Test items
TestitemsSymptom
(diagnosticdisplayonRC)Check
Indoorandoutdoorunitsareinstalledproperlyonsolidbases. Fall,vibration,noise
Norefrigerantgasleaks. Incompletecooling/heatingfunction
Refrigerantgasandliquidpipesandindoordrainhoseextensionarethermallyinsulated.
Waterleakage
Draininglineisproperlyinstalled. Waterleakage
Systemisproperlyearthed. Electricalleakage
Thespecifiedwiresareusedforinter-unitwiring. Inoperativeorburndamage
Indoororoutdoorunit’sairinletorairoutlethasclearpathofair. Incompletecooling/heatingfunction
Stopvalvesareopened. Incompletecooling/heatingfunction
Indoorunitproperlyreceivesremotecontrolcommands. Inoperative
willappearwhentheMODEbuttonispressed.* Noheating
* If the is not displayed, make sure not to cut the switching jumper (J8) for cooling operation when cutting the address jumper. If it has been cut, replace the remote controller.
Jumper (J8)
01_EN_3P320971-1A.indd 12 11/1/2012 4:44:28 PM