Barrel EMC and SMD Status Tables

22
Barrel EMC and SMD Status Tables Oleksandr Grebenyuk, NIKHEF

description

Barrel EMC and SMD Status Tables. Oleksandr Grebenyuk, NIKHEF. Outline. Tower status determination criteria Result – set of tower status tables (2003 d-Au and p-p runs) SMD strip status determination criteria Result – set of SMD status tables (2003 d-Au run) - PowerPoint PPT Presentation

Transcript of Barrel EMC and SMD Status Tables

Page 1: Barrel EMC and SMD Status Tables

Barrel EMC and SMDStatus Tables

Oleksandr Grebenyuk, NIKHEF

Page 2: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 2

Outline

• Tower status determination criteria• Result – set of tower status tables

(2003 d-Au and p-p runs)• SMD strip status determination criteria• Result – set of SMD status tables

(2003 d-Au run)• Tower status for 2004 Au-Au 62GeV run• Tower status for 2004 p-p run• Summary

Page 3: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 3

• Pedestal shape (σ, position, height)• Number of signal hits / event above PED+6σ

Threshold for signal fraction calculation:

6σ above pedestal

Good tower ADC spectrum (5K d-Au events)

Pedestal peak+ Gaussian fit

BEMC Tower Status Criteria

ADC

Page 4: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 4

Pedestal shape

No pedestal

Pedestal is too broadσ > 3

BEMC Tower Status Criteria

d-Au

ADC

ADC

Page 5: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 5

Signal fraction

0.001 < signal fraction < 0.03 for d-Au

0.00015 < signal fraction < 0.01 for p-pExample:

No signal, pedestal only

BEMC Tower Status Criteria

d-Au

0.001

ADC

Page 6: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 6

BEMC Tower Status – 2003 d-AuLegend:

Cold

Off

Bad

Bad towers:240 (10%)

Page 7: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 7

BEMC Tower Status – 2003 p-pLegend:

Cold

Off

Bad

Bad towers:453 (19%)

Page 8: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 8

BSMD Strip Status Criteriafor 2003 d-Au (by Martijn Russcher)

• Pedestal shape (σ, position)• Signal fraction: above PED+20 or PED+4σ

Good strip ADC spectrum, 25K d-Au events

ADC

Page 9: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 9

BSMD Strip Status CriteriaPedestal shape

Pedestal is too broad σ > 5

Negative pedestalnot always a problem

No pedestalmany zeroes

ADC

ADC

ADC

Page 10: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 10

BSMD Strip Status CriteriaSignal fraction

Number of hits / event above PED+20 or PED+4σ if σ>5Fixed threshold used to make it flat in η while σ changes

0.0002 < signal fraction < 0.005

No signal, pedestal only

ADC

Page 11: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 11

BSMD-eta Strip Status – 2003 d-Au

Day

Strip ID

Colour-coded status, bad when >3White: data not analysed

Bad strips:1400 (16%)

Page 12: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 12

BSMD-phi Strip Status – 2003 d-Au

Day

Strip ID

Colour-coded status, bad when >3White: data not analysed

Bad strips:900 (10%)

Page 13: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 13

2004 Au-Au 62GeV RunTower Status

By Thorsten Kolleger:

- Similar set of quality checks

- 8.4% of bad towers

- BEMC was quite stable (within 0.1%)

Page 14: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 14

2004 p-p RunTower Status

By David Relyea:

- Similar set of quality checks

- Small fraction of data analysed

- 15-20% of bad towers

Page 15: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 15

Summary

• Tower status tables produced– 2003 d-Au and p-p– 2004 Au-Au 62GeV and p-p

• SMD status tables produced– 2003 d-Au

• 2003 d-Au tower and SMD status tables were checked in π0 analysis (both real data and MC simulation) and put into DB

Page 16: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 16

The End

Page 17: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 17

SMD

PSD

Δφ = 6˚

30 cm

23 cm

Module front view

Tower

Page 18: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 18

BEMC Tower Status – d-Au

Some cleanup:• No signal at a certain run good at that run• Signal fraction ~ threshold cold all the time• Bad > 20% of time bad all the time• No signal > 50% of time cold all the time

+ 120 bad towers from 2003 LED test(Stephen T., Alex St.)

Page 19: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 19

BEMC Tower Status Tables

• 2003 d-Au:– 48 tables / 84 days: exact detector status– 1 table for d-Au: ~0.5% acceptance uncertainty

• 2003 p-p:– 100 tables / 67 days: exact detector status– 1 table for p-p: ~1.5% acceptance uncertainty

Status table: array of status codes (one per tower) with timestampused in reconstruction, simulation and efficiency/acceptance calculations

Page 20: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 20

BSMD-eta

PED+20 vs. PED+4σ

η η

η

Page 21: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 21

BSMD-phi

PED+20 vs. PED+4σ

Page 22: Barrel EMC and SMD Status Tables

3-5 December 2004 STAR Analysis Meeting, BNL 22

π0 analysis with 2003 d-Au status tables

- Improvement in the π0 invariant mass spectrum

- MC simulation gives 76% detector acceptance

Inv. mass spectrum with default status tables With these tables

Legend:

HighTower1MinBias

HighTower2