Audio Notes ense dvanced - WolfSense · Audio Notes Example Screens ... The AdvancedSense meter...

2
Advanced Environmental Instrumentation Harnessing the Power of Mobile Computing Surveyed Documented Reported Live Display Live Graph Audio Notes Example Screens Site/Location Description TVOC 186 ppb Carbon Dioxide 593 ppm Carbon Monoxide 1.2 ppm Hydrogen Sulfide 0.49 ppm ΔP -0.3 Pa Barometric 1013.2 mbar Temp1 21.0 °C Temp2 22.3 °C ΔT 1.3 °C Menu Live: Plant\Front Office New Site New Loc Rename Del Outdoor Live: General Office 3 Available Memory: 4096MB or approx 396 minutes of recording at 11KHz Audio Note: General Office 3 Play Stop Record Logging: Carbon Monoxide ppm Options Full Screen Select 1.5 1 0.5 0 15min STEL 0.62: 8-hr TWA 0.06 Min 0.05 Max 1.1 ppm 4:49 4:59 5:09 5:19 5:29 5:39 Menu Live TVOC 737 µg/m3 Carbon Dioxide 563 ppm Carbon Monoxide 0.8 ppm Ozone 0.19 ppm Temperature 72.5 °F Relative Humidity 21.2 %RH File Log Probe View Live: Bldg 6\General Office Menu Snap Logging to Front Office Menu Live Log LBJ Office Bldg 2nd floor Conference Room Administration 1 Administration 2 Executive Office 1 Executive Office 2 FRANK’S OFFICE 1st floor Feature rich with productivity tools that make your environmental surveys more efficient, more detailed, more reliable: • Voice notes with optional audio to text transcription • Optional camera for photo/video notes • Text notes, field (Word template) notes, event notes and more in-situ • On-board educational info, application docs, sensor tips and more • Data transfer & reporting software for trend graphs, note management & much more Optional WiFi access via GrayWolfLive Highly intuitive and extremely Easy-To-Use GrayWolf is transforming the way that environmental measurements are taken. The AdvancedSense meter runs highly advanced, very user-friendly application software. Display, data-log and annotate (on-site) a broad range of parameters with a single, rugged, cutting edge instrument. Simultaneously connect 1 or 2 GrayWolf DirectSense ® probes (plus a particulate or HCHO meter) with up to 6 sensors per probe (even more probes with Y-adapters) Available sensors; auto-zeroing differential pressure, barometric pressure, VOCs (PID), CO 2 (NDIR), %RH, ºC / ºF, CO, O 3 , NH 3 , H 2 S, NO, NO 2 , SO 2 , Cl 2 , EtO, HCN, HF, HCl and other parameters 2 thermocouple sockets (standard) for air, liquid, surface temperature measurement (solo or differential) Backlit color touch screen with virtual keyboard (for text input such as descriptive data file names) Environmental Test Meter A dvanced S ense ® GRAYWOLF ® SENSING SOLUTIONS Ph. 1-203-402-0477 Fax: 1-203-402-0478 Email: [email protected] Website: www.GrayWolfSensing.com

Transcript of Audio Notes ense dvanced - WolfSense · Audio Notes Example Screens ... The AdvancedSense meter...

Page 1: Audio Notes ense dvanced - WolfSense · Audio Notes Example Screens ... The AdvancedSense meter runs highly advanced, very user-friendly ... Optional ACC-CAM-P1 for photo

Advanced Environmental InstrumentationHarnessing the Power of Mobile Computing

Surveyed Documented Reported

Live DisplayLive Graph

Audio Notes

ExampleScreens

Site/Location Description

TVOC 186ppbCarbonDioxide 593ppmCarbonMonoxide 1.2ppmHydrogenSulfide 0.49ppmΔP -0.3PaBarometric 1013.2mbarTemp1 21.0°CTemp2 22.3°CΔT 1.3°C

Menu Live:Plant\FrontOffice

NewSiteNewLocRenameDelOutdoor

Live:GeneralOffice3

AvailableMemory:4096MBorapprox396minutesofrecordingat11KHz

AudioNote:GeneralOffice3

PlayStopRecord

Logging:CarbonMonoxideppm

OptionsFullScreenSelect

1.5

1

0.5

0

15minSTEL0.62:8-hrTWA0.06Min0.05Max1.1ppm

4:49 4:595:09 5:19 5:29 5:39

MenuLive

TVOC 737µg/m3

CarbonDioxide 563ppm

CarbonMonoxide 0.8ppm

Ozone 0.19ppm

Temperature 72.5°F

RelativeHumidity 21.2%RH

FileLogProbeView

Live:Bldg6\GeneralOfficeMenuSnap

LoggingtoFrontOffice

MenuLiveLog

LBJOfficeBldg2ndfloor

ConferenceRoomAdministration1Administration2ExecutiveOffice1ExecutiveOffice2FRANK’SOFFICE

1stfloor

Feature rich with productivity tools that make your environmental surveys more efficient, more detailed, more reliable:• Voice notes with optional audio to text

transcription• Optional camera for photo/video notes• Text notes, field (Word template) notes,

event notes and more in-situ• On-board educational info, application docs,

sensor tips and more• Data transfer & reporting software for trend

graphs, note management & much more• Optional WiFi access via GrayWolfLive™

Highly intuitive and extremely Easy-To-Use

GrayWolf is transforming the way that environmental measurements are taken. The AdvancedSense meter runs highly advanced, very user-friendly

application software. Display, data-log and annotate (on-site) a broad range of parameters with a single, rugged, cutting edge instrument.

Simultaneously connect 1 or 2 GrayWolf DirectSense® probes (plus a particulate or HCHO meter) with up to 6 sensors per probe (even more probes with Y-adapters)

Available sensors; auto-zeroing differential pressure, barometric pressure, VOCs (PID), CO2 (NDIR), %RH, ºC / ºF, CO, O3, NH3, H2S, NO, NO2, SO2, Cl2, EtO, HCN, HF, HCl and other parameters

2 thermocouple sockets (standard) for air, liquid, surface temperature measurement (solo or differential)

Backlit color touch screen with virtual keyboard (for text input such as descriptive data file names)

En

viro

nm

en

tal

Test

Me

ter

Adva

nced

Sens

Graywolf

®

SenSinG SolutionSPh. 1-203-402-0477fax: 1-203-402-0478

email:[email protected] website:www.GraywolfSensing.com

Page 2: Audio Notes ense dvanced - WolfSense · Audio Notes Example Screens ... The AdvancedSense meter runs highly advanced, very user-friendly ... Optional ACC-CAM-P1 for photo

E n v i r o n m e n t a l Te s t M e t e r

www.GraywolfSensing.com

email: [email protected]

Graywolf SenSinG SolutionS6 research Drive (worldwide Headquarters)Shelton, Ct 06484 uSaPh. (1)203-402-0477 800-218-7997 fax: (1)203-402-0478

oCtoBer 2014

AdvancedSense®

2m dual tubing is supplied with optional differential pressure sensor. GrayWolf offers a selection of pitot tubes for air velocity and K thermocouples for temperature measurement.

WiFi Card and Remote Access Software, Advanced Reporting Software,

Calibration kits and other accessories are available from GrayWolf.

View them online at accessories.graywolfsensing.com

WolfSense® PC data transfer and analysis software supplied as

standard

PCC-10A Hardshell Security case holds AdvancedSense, probes & accessories. Smaller/larger cases also available.

Measure Smart report efficiently

PCC-AS01 pouch with neck strap and belt loop for hands-free surveys

Front View

Right Side View

Optional ACC-CAM-P1 for photo and video capture tagged to data files.

Bottom View

Top View

Differential Pressure is auto-zeroing (every 2 minutes by default but zeroing frequency is user adjustable)

*The barometric pressure sensor, when installed, will compensate mass concentration readings (µg/m3) for pressure changes.

Graywolf SenSinG SolutionSannacotty industrial Park, unit 1Cannacotty, County limerick irelandPh. (353) 61358044fax: (353) 61358160

TVOC 1275 ppb

Carbon Dioxide 2143 ppm

Carbon Monoxide 0.0 ppm

Sulfur Dioxide 0.0 ppm

Temperature 0.0 °CRelative Humidity 53.2 %RH

ΔP 0.2 Pa

Barometric 996 mbar

Air Speed 0.6 m/s

File Log Probe View

Live: Fabrication FloorMenu

Optional Built-in Sensors:Differential Pressure (DP-702LH) Barometric Pressure (BP-101)*

Range ±10,000Pa, ±40 inH2O, ±1000 mmH2O, ±100 mbar, ±70 mmHg

600 to 825 mmHg, 800 to 1100mBar, 23.50 to 32.50 inHg, 0.80 to 1.10atm

Resolution 0.1 Pa, 0.001 inH2O, 0.01 mmH2O,0.001 mbar, 0.001 mmHg

0.1mmHg, 0.1mBar, 0.01 inHg, 0.01atm±0.1% rdg

Accuracy (auto-zeroing enabled)

±1% of rdg ±0.1Pa up to 250Pa, ±1%rdg ±4Pa >250Pa (±1% of rdg ±0.001

inH2O to 1.000 inH2O, ±1%rdg ±0.015 inH2O>1.000 inH2O)

SPECIFICATIONS:(for additional sensor/probe specifications refer to GrayWolf’s DirectSense®, pitot tube and thermocouple brochures)

General:Dimensions: 96.0mm (3.8in.) w. x 177mm (7.0in.) h. x 47.0mm (1.8in) d.Construction: Rugged polycarbonate plastic with rubberized side grips. IP64Weight: 700gr (1lb 8.5oz.) Add 50gr (1.5oz.) for auto-zeroing ∆P optionScreen Size: 785mm (3.5in.) QVGA 240 x 320 TFT color touch screen with backlightMemory: 4GB for data-logging (1 million+ readings) and notes (photo/video/audio);

plus 2GB for program, help videos, documents and auto data backupAudio: Integral electret microphone (on front) and 4 ohm speaker (on back)Mounting: ¼” - 20 thread (on back) for belt clip, etc. (& for included mini tripod/stand)Operating Range: -10ºC to 50ºC (-15ºF to 122ºF), 0 to 100 %RH non-condensingConnectors:2 x Lemo 8 pin for GrayWolf DirectSense probes (the AdvancedSense will support up to 4 x DirectSense probes with Y-adapters)1 x Lemo 7 pin for particulate, 3rd party meters or RH-AS2 %RH, ºC / ºF probe2 x sub-mini type K thermocouple temperature sockets. Range -80 to 1100ºC (-110 to 2010ºF)1 x Lemo 7 pin socket for formaldehyde meter, camera or optional USB key download cable1 x USB mini B socket. 1m USB B to USB A download cable supplied as standard1 x 9V power adapter socketOptional; 2 x 4mm posts for differential pressure tubingPower:Battery: 4250 mAh Lithium Ion rechargeableBattery Life: 32+ hours typical for new battery with backlight off (and probes self-powering)

The AdvancedSense can power DirectSense probes. Battery lifewill vary when powering probes or pressure sensors

Recharge time: 4 hours typical. LED displays charging/fully charged statusPower supply: 100/240VAC, 50-60Hz external charger. Specify local plugAll specifications are subject to change without further notice