2
Specification Specification Specification Specifications Type Type Type Type Mesuring Range Mesuring Range Mesuring Range Mesuring Range μSv/h mSv/h 0 0.1 1 10 100 1 10 100 1000 10000 AE-133LW/Λ2 AE-133L/Λ2 AE-133/Λ2 AE-133V/Λ2 AE AE AE AE-133B 133B 133B 133B AE-133H AE-133BH Measuring Measuring Measuring Measuring Quantity Quantity Quantity Quantity and and and and Radiation Radiation Radiation Radiation Detected Detected Detected Detected H’(0.07) and H * (10) Beta ray( 147 Pm90 Sr90 Y) E max : 225keV to 2.28MeV X and γ ray at 60keV to 3MeV Output Output Output Output Output terminal: +10mV full scale Output impedance: 100Ω Unit Unit Unit Unit Switching Switching Switching Switching ×10 and ×1000 Power Supply Power Supply Power Supply Power Supply Battery: four 6F22(9V) and one NC706(24V) It is possible to use AC adapter (option). Range Range Range Range (×10) 3, 10, 30, 100 μSv/h (×1000) 3, 10, 30, 100 mSv/h Battery Life Battery Life Battery Life Battery Life 6F22:approximately 170 hours (continuous use) NC706: approximately 5 years. See the expiration date written on NC706. Measuring Measuring Measuring Measuring Range Range Range Range Minimum scale : 1μSv/h to 100mSv/h It is possible to read at 0.5μSv/h. Battery Check Battery Check Battery Check Battery Check Push the button and power supply can be checked except for applied voltage (NC706). Response Response Response Response Time Time Time Time (×10) within 10 seconds exclude 3μSv/h range (×1000) within 1 second Environmental Environmental Environmental Environmental Condition Condition Condition Condition 5to +45Relative humidity is less than 90%. Linearity Linearity Linearity Linearity H’(0.07) : 0.8 to 1.2 (0.5 to 1.8MeV/Eres) H * (10) : 0.88 to 1.12 (80kev to 3MeV) Dimension Dimension Dimension Dimension 177mm(D) × 134mm(W) × 151mm(H) Standard Standard Standard Standard Accessories Accessories Accessories Accessories Build Up Cap for H * (10) and inner filter made from acryl and thickness is 0.5mm. Weight Weight Weight Weight Body: approximately 1600g Batteries (6F22 and NC706): 200g Detector Detector Detector Detector Parallel plate type ionization chamber with thin film window Volume : approximately 60ml Dimension of aperture : φ99.6mm

Transcript of AE133B catalog E05 mSv unit R2 01 · Outside dOutside drawing of rawing of rawing of...

Page 1: AE133B catalog E05 mSv unit R2 01 · Outside dOutside drawing of rawing of rawing of AEAAEEAE----133 B133 B Energy and dEnergy and directionirectionirection characteristicscharacteristics

SpecificationSpecificationSpecificationSpecificationssss

TypeTypeTypeType

Mesuring RangeMesuring RangeMesuring RangeMesuring Range

µSv/h mSv/h

0 0.1 1 10 100 1 10 100 1000 10000

AE-133LW/Λ2

AE-133L/Λ2

AE-133/Λ2

AE-133V/Λ2

AEAEAEAE----133B133B133B133B

AE-133H

AE-133BH

Measuring Measuring Measuring Measuring Quantity Quantity Quantity Quantity and and and and RadiationRadiationRadiationRadiation DetectedDetectedDetectedDetected

H’(0.07) and H*(10) Beta ray(147Pm~90Sr-90Y) Emax : 225keV to 2.28MeV X and γ ray at 60keV to 3MeV

OutputOutputOutputOutput Output terminal: +10mV full scale Output impedance: 100Ω

Unit Unit Unit Unit SwitchingSwitchingSwitchingSwitching

×10 and ×1000 Power SupplyPower SupplyPower SupplyPower Supply Battery: four 6F22(9V) and

one NC706(24V) It is possible to use AC adapter (option).

RangeRangeRangeRange (×10) 3, 10, 30, 100 µSv/h (×1000) 3, 10, 30, 100 mSv/h

Battery LifeBattery LifeBattery LifeBattery Life

6F22:approximately 170 hours (continuous use)

NC706: approximately 5 years. See the expiration date written on NC706.

Measuring Measuring Measuring Measuring RangeRangeRangeRange

Minimum scale : 1µSv/h to 100mSv/h ※It is possible to read at 0.5µSv/h.

Battery CheckBattery CheckBattery CheckBattery Check Push the button and power supply can be checked except for applied voltage (NC706).

Response Response Response Response TimeTimeTimeTime

(×10) within 10 seconds exclude 3µSv/h range (×1000) within 1 second

Environmental Environmental Environmental Environmental ConditionConditionConditionCondition

-5℃ to +45℃ Relative humidity is less than 90%.

LinearityLinearityLinearityLinearity H’(0.07) : 0.8 to 1.2 (0.5 to 1.8MeV/Eres) H*(10) : 0.88 to 1.12 (80kev to 3MeV)

DimensionDimensionDimensionDimension 177mm(D) × 134mm(W) × 151mm(H)

Standard Standard Standard Standard AccessoriesAccessoriesAccessoriesAccessories

Build Up Cap for H*(10) and inner filter made from acryl and thickness is 0.5mm.

WeightWeightWeightWeight Body: approximately 1600g Batteries (6F22 and NC706): 200g

DetectorDetectorDetectorDetector Parallel plate type ionization chamber with thin film window Volume : approximately 60ml Dimension of aperture : φ99.6mm

Page 2: AE133B catalog E05 mSv unit R2 01 · Outside dOutside drawing of rawing of rawing of AEAAEEAE----133 B133 B Energy and dEnergy and directionirectionirection characteristicscharacteristics

Outside dOutside dOutside dOutside drawing of rawing of rawing of rawing of AEAEAEAE----133 B133 B133 B133 B

Energy and dEnergy and dEnergy and dEnergy and directionirectionirectionirection characteristicscharacteristicscharacteristicscharacteristics

*Connector for AC adapter (EXT POWER) is an option.

Due to our policy of continued development, specifications are subject to change without notice.

APPLIEDAPPLIEDAPPLIEDAPPLIED ENGINEERING INC.ENGINEERING INC.ENGINEERING INC.ENGINEERING INC. ■Exposure Meters For Environmental Radiation/For Radio Therapy ■Electronics Apparatus, System Machinery for Measurement of Micro Current URL:http://www.o-yo-giken.co.jp Address: 2-599, Shimokiyoto, Kiyose-shi, Tokyo, 204-0011, Japan Phone +81-42-492-2734, Fax +81-42-492-7006

45keV is reference. ●H・*(10,0) BUC (I)

○H・*(10,0) BUC (R)

◆H・

’(0.07,0) BUC (I)

◆H・

’(0.07,0) BUC (R)

(X and gamma ray)

Energy response (22℃,1013hPa)

maximum residual energy of beta raymaximum residual energy of beta raymaximum residual energy of beta raymaximum residual energy of beta ray

DirectionDirectionDirectionDirection characteristicscharacteristicscharacteristicscharacteristics

for beta ray (0.07,for beta ray (0.07,for beta ray (0.07,for beta ray (0.07,αααα)/(0.07,0))/(0.07,0))/(0.07,0))/(0.07,0)

RR RRelative value for angle of 0 degrees

elative value for angle of 0 degrees

elative value for angle of 0 degrees

elative value for angle of 0 degrees

incident angleincident angleincident angleincident angle incident angleincident angleincident angleincident angle

DirectionDirectionDirectionDirection characteristicscharacteristicscharacteristicscharacteristics

for beta ray (0.07,for beta ray (0.07,for beta ray (0.07,for beta ray (0.07,αααα)/(0.07,0))/(0.07,0))/(0.07,0))/(0.07,0)